• Title/Summary/Keyword: Window-effect

Search Result 741, Processing Time 0.029 seconds

Speech Intelligibility Analysis on the Vibration Sound of the Glass Window of a Conference Room (회의실 유리창 진동음의 음성 명료도 분석)

  • Kim, Hee-Dong;Kim, Yoon-Ho;Kim, Seock-Hyun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.4 s.121
    • /
    • pp.363-369
    • /
    • 2007
  • The purpose of the study is to obtain acoustical information to prevent eavesdropping of the glass window. Speech intelligibility was investigated on the vibration sound detected from the glass window of a conference room. Objective test using speech transmission index(STI) was performed to estimate quantitatively the speech intelligibility. STI was determined based on tile modulation transfer function(MTF) of the room-glass window system. Using Maximum Length Sequency(MLS) signal as a sound source, impulse responses of the glass window and MTF were determined by signals from accelerometers and laser doppler vibrometer. Finally, speech intelligibility of the interior sound and window vibration were compared under different sound pressure levels and amplifier gains to confirm the effect of measurement condition on the speech intelligibility.

The Change of Heating and Cooling Load according to the Thermal Insulation Performance of Window for an Apartment House (창호의 단열성능에 따른 공동주택 냉난방 부하량 변화)

  • Song, Su-Bin;Kim, Young-Tag;Yoon, Seong-Hwan
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.853-856
    • /
    • 2008
  • Windows have an great effect on annual building load because windows are the weakest parts of building envelope thermally. To reduce the consumption of building energy, the thermal performance of window has to be improved in first place. Therefore this research aims to make a quantitative analysis of the heating and cooling load according to the window thermal performance using the heat load simulation program. As a result of the simulation, annual heat load is down 38% according to the decrease of U-value of window, 1.00 W/$m^2K$. and annual heat load is up 10% according to the decrease of shading coefficient, 0.20. The annual load of the window with Low-E glass is 15% lower than the window with pair glass.

  • PDF

The Effect of Design Originality in Fashion Window Display on the Attitudes Toward Fashion Brands and the Purchasing Intention (패션 윈도우 디스플레이의 디자인 독창성이 브랜드 태도와 구매의도에 미치는 영향)

  • Choi, Eun Young
    • Journal of the Korean Society of Costume
    • /
    • v.63 no.1
    • /
    • pp.120-134
    • /
    • 2013
  • This study was intended to investigate the designs that are displayed on fashion windows, specifically the originality of its designs, from here on noted as "design originality", and the effects it has on the attitudes of consumers toward fashion brands and their purchasing intentions depending on their level of clothing involvement. For the purpose of this study, 10 pictures of creative fashion window display designs from Fifth Avenue in New York were selected and they were shown to 200 college students in Busan in order to collect data for the analysis. The results are as follows: 1) Factor analysis identified four factors that impacted how consumers judged design originality, uniqueness, humor, favorable impression and advanced design. 2) The four factors of design originality in fashion window display significantly affected consumer's evaluation on usefulness of information provided by the window display, attitudes toward fashion brands and purchase intention. 3) The respondents were separated into two groups depending on their level of clothing involvement. Consumers with high level of clothing involvement showed that they were influenced more by the design originality when making purchase decisions. Especially, the uniqueness factor and advanced design factor had more effect on brand attitudes and purchase intention in high level of clothing involvement group. The results revealed that creative fashion window display design are important marketing strategic tools that affect attitudes of consumers toward brands and their purchasing intentions.

Luminance Performance of a Room with Light Guide and Blind Systems by Mockup Experiments (혼합형 채광조절장치가 실내공간의 휘도분포에 미치는 영향에 관한 Mockup 실험평가)

  • Shin, Hwa Young;Ahn, Hyun Tae;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.7 no.1
    • /
    • pp.65-72
    • /
    • 2007
  • As ecological design elements, daylighting can be applied to provide adequate illumination on visual tasks to create an attractive visual environment and to save electrical energy. Daylighting control systems reject direct sunlight and penetrate it onto the ceiling or to deep into the room. This study aims to evaluate the luminance environment of sloped light guide with automated venetian blind systems according to sun angle changes. For evaluation, a mock-up model was used and the south facing side-window mounted between the clerestory window and the view window. To assess luminance performance, 3 view points of luminance were monitored. As results, the conventional and lightshelves show ideal luminance ratio between workplane and surroundings(3:1) and workplane and darkness area(2:1) due to total ratio of surroundings and darkness area has lower ratio than workplane. Compared to the lightshelves window, conventional window shows unrelieved effect in between the workplane and brightness area(1:5). It means that there has low deviation according to the required standards. Also, compared to the ratio between the brightness area and darkness area(2~6:1) conventional window with high deviation(10~20:1) provide discomfort glare due to the excessively strong contrast, while lightshelves window shows a required luminance ratio that provide a three-dimensional effect to occupants. Therefore, luminance distribution indicate that application of a lightshelves and blinds not only has a significantly positive effect but also offers higher luminance quality in a daylit room

An Experimental Study on the Effect of Hanji Windows on Indoor Air Temperature and Humidity Control (한지창호의 실내 온.습도 조절효과에 관한 실험적 연구)

  • Jang Gil-Soo;Park Sa-Keun;Song Min-Jeong;Shin Hoon
    • Journal of the Korean housing association
    • /
    • v.17 no.2
    • /
    • pp.125-134
    • /
    • 2006
  • The tightness of windows have devoted to the improvement of thermal insulation and energy saving in buildings. But it is known that this tightness causes some side effects such as low ventilation, low capacity to humidity and temperature control and these are not profitable for inhabitants. To act on these side effects, Korean traditional windows which are composed of Han-Ji(Koreand traditional paper) and Chang-Sal(Korean traditional wooden frame) have been studied to get a reasonable solutions for these problems. In this study, to compare the thermal and humidity control performance of current window(12 mm pair) and Korean traditional windows, frames which are made of existing window and Korean traditional windows are adapted to scale model house and then humidity and temperature of in and out of scale model house are measured and analysed. The results of this study are followings ; 1) When Korean traditional window charges 20cm(1/8 of total window area) from total window area, Han-Ji window has higher thermal insulation than that of existing window in daytime. There is the most big thermal difference when double faced with double-ply Han-Ji window is placed to mock-up house. In night-time, the temperature difference is very small so this means that Korean traditional window is good to cover direct sunlight in daytime and reduce the temperature of balcony. One faced with one-ply han-Ji window has the best humidity penetration performance among three type of Korean traditional windows. 2) When Korean window area enlarged to 40cm(1/4 of total window area), the function of 40cm width Han-Ji window is higher than that of 20cm's. This means that enlargement of Han-Ji window cover direct sunlight more and is more efficient in humidity penetration.

A Study on the Application Effect of DSSC BIPV Window System in Office Building Considering Cooling.Heating.Lighting Energy (냉.난방 및 조명에너지를 통합 고려한 DSSC BIPV창호의 사무소건물 적용 효과 연구)

  • Sim, Se-Ra;Yoon, Jong-Ho;Shin, U-Cheul
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.3
    • /
    • pp.67-72
    • /
    • 2011
  • The aim of this study is to evaluate how much would the building energy consumption be saved by applying DSSC BIPV window which is possible to control the transmittance and express the color in the office building. For this, physical characteristics such as transmittance and reflectance, U-factor of DSSC areanalyzed and an annual energy consumption that is connected to dimming control is calculated when DSSC BIPV window is applied by alternate clear window system. As a result, It is possible to reduce the anannual energy consumption as much as4.1% by just change the clear double window system to DSSC BIPV double window system because the major factor to reduce energy consumption in the office that has much cooling load than other building is SHGC. When the thermal insulation properties of DSSC BIPV window with low-e coating and making triple window are improved, energy saving ratio is about 9%. Plus, energy saving ratio of 25~28% in lighting energy consumption is possible when the dimming control system with DSSC BIPV window is adopt.

Effect of the size of the bony access window and the collagen barrier over the window in sinus floor elevation: a preclinical investigation in a rabbit sinus model

  • Sim, Jeong-Eun;Kim, Sangyup;Hong, Ji-Youn;Shin, Seung-Il;Chung, Jong-Hyuk;Lim, Hyun-Chang
    • Journal of Periodontal and Implant Science
    • /
    • v.52 no.4
    • /
    • pp.325-337
    • /
    • 2022
  • Purpose: The aim of this study was to investigate the effect of (1) the size of the bony access window and (2) collagen membrane coverage over the window in sinus floor elevation in a rabbit sinus model. Methods: Small bony access windows (SW; ø 2.8 mm) were made in 6 rabbits and large windows (LW; ø 6 mm) in 6 other rabbits. Both sinuses in each rabbit were allocated to groups with or without coverage of a collagen membrane (CM) on the window, resulting in 4 groups: SW, LW, SW+CM, and LW+CM. After 4 weeks of healing, micro-computed tomographic, histologic, and histomorphometric analyses were performed. Results: Bony healing in the window area was incomplete in all groups, but most bone graft particles were well confined in the augmented cavity. Histologically, the pattern of new bone formation was similar in all groups. Histomorphometrically, the percentage of newly formed bone was greater in the groups with CM than in the groups without CM, and in the groups with SW than in the groups with LW (12.92%±6.40% in the SW+CM group, 4.21%±7.73% in the SW group, 10.45%±4.81% in the LW+CM group, 11.77%±3.83% in the LW group). The above differences were not statistically significant (P>0.05). Conclusions: The combination of a small bony access window and the use of a collagen membrane over the window favored new bone formation compared to other groups, but this result should be further investigated due to the limitations of the present animal model.

ebXML Collabration Model of Single Window for Marine Transport

  • Lee, Young-Chan;Ahn, Kyeong-Rim
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.3
    • /
    • pp.301-309
    • /
    • 2007
  • Netherlands had suggested a uniform system to standardize and simplify EDI systems relating to the Arrival/Departure, stay, and clearance of ships, persons, and cargoes for the Facilitation of International Maritime Transport to the International Maritime Organization(IMO). Republic of Korea proposed the Framework of XML-based Single Window System for the simplified clearance of ships to the 32nd session of Facilitation Committee of the IMO. Accordingly the authors studied that the XML Infrastructure for Single Window efficiently supports the Single Window service and the business collaboration between business entities of logistics. The proposed XML Infrastructure designs to support the various document format translation and to easily manage. Therefore business entity using the proposed system has the effect of downing the resource and costs on using Single Window.

Performance Estimation of a Window Shaker (유리창 도청방지 장치의 성능평가)

  • Kim, Seock-Hyun;Kim, Hee-Dong;Heo, Wook
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.649-654
    • /
    • 2007
  • Eavesdropping prevention performance is evaluated on a commercial window shaker, which is used to prevent a glass window from eavesdropping. Speech transmission index (STI) is introduced in order to estimate quantitatively the speech intelligibility of the sound detected on the glass window. Objective test by IEC standard using modulation transfer function (MTF) is performed to determine STI. Using Maximum Length Sequency (MLS) signal as a sound source, MTF is measured by accelerometers and laser doppler vibrometer. STI under different level of disturbing wave are compared to confirm the disturbing effect on the speech intelligibility.

  • PDF

Post-Annealing Effect of GZO/ZnO/CdS Window Layers for CIGS Solar Cells

  • Park, Jun-Tae;Hwang, Jung-Hwan;Jeong, Su-Chang;Choe, Yun-Su;Choe, Hyeon-Gwang;Jeon, Min-Hyeon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.309-309
    • /
    • 2013
  • 기존의 CIGS 태양전지는 window 층(GZO/ZnO/CdS)에서의 투과 및 반사 손실을 줄이기 위하여 MgF2를 이용한 AR (Anti Reflection) 층을 적용하여 cell을 제작하고 있다. 현재 단위공정을 줄이고 시간적 경제적 비용을 절감하기위해 무반사 코팅층 없이 표면의 구조를 변화 시키거나 CIGS 태양전지의 window 층만으로 cell 구조에 적용하는 연구가 많이 진행되고 있다. 본 연구는 AR층과 window층 역할을 동시에 만족하는 일체화된 window층 두께를 설계하고 성장한 후, window층의 열처리 전후의 구조적, 광학적 및 전기적 특성을 비교 평가하였다. Macleod simulation을 이용하여 window 층을 설계한 후, RF magnetron sputtering법을 이용하여 상온성장 시킨 후 N2 분위기에서 후열처리 조건에 따른 박막의 구조적, 전기적 및 광학적 특성을 변화를 X-ray diffractometer, Field emission-scanning electron microscope, Atomic force microscopy, 4 point probe, Hall 측정, 투과도 및 반사도등으로 비교 평가하였다.

  • PDF