• Title/Summary/Keyword: Wearing-off

Search Result 108, Processing Time 0.033 seconds

A Questionnaire Study to Investigate the Symptoms and Solutions of Wearing-off in Parkinson's Disease Patients (파킨슨병 환자의 개인별 Wearing-off 증상 및 해결책 현황 조사를 위한 설문 연구)

  • Miso S. Park;Sang Soo Park;Horyong Yoo;Jaeson Pyeon;Wang Jung Hur;Shin Young Park
    • Journal of TMJ Balancing Medicine
    • /
    • v.13 no.sup
    • /
    • pp.1-8
    • /
    • 2023
  • Objectives: Parkinson's disease (PD) is currently the most rapidly increasing degenerative brain disease due to population aging and westernization of lifestyle. Levodopa is the most commonly used drug to manage PD symptoms. However, levodopa has a problem in that the wearing-off phenomenon occurs as the duration and dose of administration increase. In order to investigate the wearing-off phenomenon in PD patients and devise countermeasures, we conducted a questionnaire survey in Korea. Methods: For the study, a questionnaire with a total of seven items was prepared. Part IV of the MDS-UPDRS (Movement Disorder Society-Sponsored Revision of the Unified Parkinson's Disease Rating Scale) and the WOQ-9 (9-symptom Wearing-off Questionnaire) were used as references. Results: Of the 48 patients who completed the questionnaire, all 47 patients who completed the questionnaire experienced the wearing-off phenomenon. Only one of the patients diagnosed with PD a year ago did not experience the wearing-off phenomenon. Patients frequently mentioned a lack of sleep and stress as aggravating factors for wearing-off. They also stated that in order to resolve the off-state, they walked, massaged, warmed up the body, stretched and exercised. Conclusions: Because wearing-off is such a common occurrence, it is thought necessary to develop wearing-off prevention and resolution measures that PD patients can use in their daily lives.

  • PDF

Analysis of REBA, RULA, OWAS of Wearing and Taking off Skinscuba Equipment for Prevention of Musculoskeletal Injuries (스킨스쿠버 장비 착용 및 벗는 자세의 근골격계 상해 예방을 위한 REBA, RULA, OWAS 분석)

  • Son, Sung-Min;Kim, Yong-Jae
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.23 no.1
    • /
    • pp.67-74
    • /
    • 2011
  • The study was constructed an analysis of postures of a expert diver's wearing and taking off with skinscuba equipment using ergonomics tools(REBA, RULA, OWAS) for prevention of Musculoskeletal injuries. This survey is consisted of 4 postures in terms of wearing and taking off : Crouching(alone), Standing(alone), Helping of assistance, Using of stanchion. Their rate of injuries is getting higher due to instability postures, exposed dangers and excessive physical actions. So this study provides basic and educational information for prevention of that. The result is as follows : The result of crouching postures of wearing alone was REBA 9(Ac Level 3), RULA 7(Ac Level 4), OWAS AC 2, and crouching postures of taking off alone was REBA 12(Ac Level 4), RULA 7(Ac Level 4), OWAS AC 4. The result of standing postures of wearing alone was REBA 8(Ac Level 3), RULA 7(Ac Level 4), OWAS AC 3, and standing postures of taking off alone was REBA 8(Ac Level 3), RULA 7(Ac Level 4), OWAS AC 3. The result of helping of assistance postures of wearing was REBA 4(Ac Level 2), RULA 3(Ac Level 2), OWAS AC 2, and standing postures of taking off alone was REBA 4(Ac Level 2), RULA 4(Ac Level 2), OWAS AC 1. The result of using of stanchion postures of wearing was REBA 3(Ac Level 1), RULA 3(Ac Level 2), OWAS AC 1, and standing postures of taking off alone was REBA 3(Ac Level 1), RULA 3(Ac Level 2), OWAS AC 1. Especially both postures of wearing and taking off alone showed high results in the analysis of postures using ergonomics tools(REBA, RULA, OWAS).

Treating Idiopathic Parkinson's Disease with Bonoesikpungjigyeong-tang: A Case Study on "Delayed On" and "Wearing Off" Phenomena after Long-term Levodopa Intake (레보도파 약효 지연 현상 및 약효 감소 현상으로 인한 자세불안정 및 전신탈력감을 호소하는 특발성 파킨슨병 환자에 대한 보뇌식풍지경탕 치험 1례)

  • Siyun Sung;Dabin Lee;Seongeun Huh;Sunghee Hong;Ye-chae Hwang;Gyeongmuk Kim;Han-Gyul Lee;Sang-Kwan Moon;Woo-Sang Jung;Seungwon Kwon
    • The Journal of Internal Korean Medicine
    • /
    • v.45 no.2
    • /
    • pp.219-233
    • /
    • 2024
  • A 69-year-old female diagnosed with idiopathic Parkinson's disease and treated with anti-Parkinsonian medications, including levodopa, for 7 years presented with complaints of wearing-off phenomenon and delayed onset of medication efficacy, resulting in postural instability and feeling of severe exhaustion. The patient underwent a 50-day course of treatment with Bonoesikpungjigyeong-tang formula. The effects of the treatment were evaluated by recording the average time to onset of medication efficacy, the average time to medication wearing-off, and discomfort due to wearing-off phenomenon. Postural instability was assessed using the Numeric Rating Scale (NRS). The patient's overall quality of life was assessed using the EQ-5D-3L. After 50 days of treatment, the average time to onset of medication efficacy decreased, and the average time to medication wearing-off increased. Discomfort due to wearing-off phenomenon and postural instability decreased. This case suggests that Bonoesikpungjigyeong-tang might be an alternative for improving discomfort caused by long-term levodopa intake.

The Influence of Rearfoot Motion Control through Marathon Shoes On and Off (마라톤화 착용 시 후족제어에 미치는 영향)

  • Kim, Young-Jae;Jang, Sung-Il
    • Korean Journal of Applied Biomechanics
    • /
    • v.15 no.2
    • /
    • pp.69-81
    • /
    • 2005
  • In this study using two-dimensional system of the analysis of image, when normal males in their twenties who have normal foot and step with heel first are walking and running, they who are wearing running shoes or barefoot are testing and comparing the exchange factors of heel control. There are following results of this test by verifying them with T-Test. 1) When they are running, there are two big different gap which is $6.05^{\circ}$ between barefoot and wearing the running shoes. The former is $174.79^{\circ}{\pm}6.31$ and the latter is $180.84^{\circ}{\pm}4.69$. But it is not statistically significant. The angle of first step with heel is $100.42^{\circ}{\pm}3.95$ with barefoot and $93.97^{\circ}{\pm}094$ with wearing the running shoes. In this case, it is statistically significant(p<.01) 2) When they are running, the angle of the Achilles' tendon has different gap which is $5.24^{\circ}$ between barefoot and wearing the running shoes. The former is $179.70^{\circ}{\pm}4.23$ and the latter is $184.94^{\circ}{\pm}4.09$. It is not statistically significant. The angle of minimal step with heel is $96.30^{\circ}{\pm}3.07$ with barefoot and $90.84^{\circ}{\pm}0.44$ with wearing the running shoes. In this case, it is statistically significant(p<.01). 3) In the angle of the Achilles' tendon and the angle of first step with heel, when they are walking, the angle of the Achilles' tendon has different gap which is $1.81^{\circ}$ between barefoot and wearing the running shoes. The former is $6.39^{\circ}{\pm}0.83$ and the latter is $8.20^{\circ}{\pm}1.85$. It is not statistically significant. The angle of first step with heel is $2.32^{\circ}{\pm}0.51$ with barefoot and $3.22^{\circ}{\pm}1.44$ with wearing the running shoes. It is not statistically significant. 4) In the angle of the take-off of Achilles' tendon, when they are walking, the angle of the take-off of Achilles' tendon has different gap which is $3.88^{\circ}$ between barefoot and wearing the running shoes. The former is $177.62^{\circ}{\pm}8.78$ and the latter is $173.74^{\circ}{\pm}16.31$. It is statistically significant(p<.05). Therefore, they are running, the angle of the take-off of Achilles' tendon is $178.37^{\circ}{\pm}19.28$ with barefoot and $171.26^{\circ}{\pm}12.18$ with wearing the running shoes. It is statistically significant(p<.05).

The Sleeve Knitting Method of the Seamless Knit One-Piece Dress - Focused on the Bind-off Length at the Axilla - (무봉제 니트 원피스 드레스의 소매 편성 방법 - 겨드랑 부위의 바인드 오프 처리 분량을 중심으로 -)

  • Lee, Mi-Sook;Kim, Myoung-Ok;Suh, Mi-A
    • The Research Journal of the Costume Culture
    • /
    • v.17 no.6
    • /
    • pp.1059-1067
    • /
    • 2009
  • The knitting method of the sleeves for improving movement adaptability were studied in this paper. The purpose of this study is proposing a knitting method that is suitable for the bodies of women in their 20's and can enhance wearing satisfaction. To see the effect of the bind-off length at the axilla, a movement adaptability test was undertaken for 4 samples that have bind-off at bodices. In addition to that, the analysis of their sliding distance with respect to the human motions were executed. The results of this study were listed below. Its result was that the samples with small bind-off lengths represent better wearing satisfaction than the samples which have large bind-off lengths. The comparison of the sliding distances at the hem, waist and sleeves with respect to the tester's motions also shows that the sample having small bind-off makes better result than the sample with large bind-off. It was observed that the optimal length of bind-off was 2cm for the improvement of the sleeve functionality.

  • PDF

A Survey on the Wearing Conditions for the Improvement of Wearing Comfort of Brassiere (브래지어의 착용감 개선을 위한 착용실태 조사)

  • Lim, Ji-Young
    • Fashion & Textile Research Journal
    • /
    • v.6 no.4
    • /
    • pp.455-460
    • /
    • 2004
  • This study was performed to analyze the wearing practice and the purchasing characteristics of brassieres in order to offer basic data to produce superior brassiere and to improve the wearing comfort. The questionnaire were 146 Korean college female students. For data analysis, descriptive analysis, crosstabs, factor analysis and one-way ANOVA were used. The results were as follows, first, most subjects didn't know the sizing system of brassiere and their own breast size. So the degree of satisfaction of wearing brassiere was low than subjects who knew their own breast size. And they replied that the most unsatisfaction factor was brassiere size. Second, when subjects decided to purchase a brassiere they considered size, design, color, cost, fabric and brand and so on. Among them size and design were considered the most important. Third, the subjects who wear brassiere all day long, they considered wearing comfort and cost rather than design and collar. Therefore, the markets with brassieres would be able to segmented based on consumers' characteristics. Firth, the subjects were dissatisified at size, the taking off wire and shape modification after washing. And they requested the development of various size, fabric and cost improvement and fittness of brassieres. These results imply that to improve the wearing comfort of brassiere, it is so important to produce and develop various types of size first of all. And consumers should know size system of brassiere and their own breast size.

Investigation of Girdle Wearing of Female College Students (여대생(女大生)의 거들 착용실태(着用實態) 분석(分析))

  • Park, Eun-Joo;Han, Eun-Gyeong
    • Journal of Fashion Business
    • /
    • v.5 no.3
    • /
    • pp.49-61
    • /
    • 2001
  • In this study, girdle wearing was surveyed on the female college students in Seoul and Seoul satellite cities. Data were collected by convenient sampling method, and sample size was 252 subjects in 18 to 29 years. Questionnaire was composed of 5 parts: experience of girdle wearing, the preference of girdle type, degree of dissatisfaction/discomfort in wearing girdle, wear sensation evaluation of girdle fabrics, including demographic and anthropometric data. The results of surveys are as follows: Experience of girdle wearing (season of wearing girdle, main intention of wearing girdle, frequency of wearing, body part to want to be shaped by girdle) was examined. Especially body parts to be shaped by girdle were in order of abdomen > hip > thigh > waist-hip sideline. Therefore, it would be considered that female college students want to care about the shape of abdomen or hip. The long leg panty type was most preferred among the girdle types. The reason of preference of long leg panty type was cost > easiness of putting on-and-off > shaping many body parts at once. For dissatisfaction/discomfort in wearing the commercial girdles, it showed in order of poor ventilation at sweating > static electricity with outer garment > difficult breathing due to pressure > deformation after laundering.

  • PDF

Status quo Analysis on the Wearing Practice of Household Rubber Gloves for Quality Improvement (가정용 고무장갑의 품질개선을 위한 사용실태 분석)

  • 전은경;유화숙;임지영
    • Journal of the Korean Home Economics Association
    • /
    • v.40 no.4
    • /
    • pp.45-57
    • /
    • 2002
  • This study was conducted to analyze the wearing practice and the purchasing characteristics of household rubber gloves in order to obtain the product demands for quality improvement. The effects of wearing time per day and demographic characteristics on those were evaluated. A questionnaire was developed and administered to 494 housewives. Statistical tests such as descriptive analysis, crosstabs, factor analysis, one-way ANOVA, were used to analyze the data. The results indicated that housewives were largely divided into two groups according to the wearing time per day. One group wore gloves more than 3 hours a day, while the other wore less than 3 hours. We found that there were significant differences in the wearing practice and the purchasing characteristics between these two groups. It showed that the quality improvement of household rubber gloves should be achieved in a point of view of the comfort feeling and easiness in wearing and taking off. The housewives showed positive attitude toward pliability and necessity, while negative altitude toward dryness, comfort and mobility in wearing. The household rubber gloves were identified as the necessities which is so familiar and common that only a few of demographic characteristics have effect on.

Can prosthetic limbs made too quickly cause kidney damage?: a pilot study

  • Petrofsky, Jerrold S.;Browne, Mary;Jamshidi, Mahyar;Libo-on, Anthony;Lee, Haneul
    • Physical Therapy Rehabilitation Science
    • /
    • v.3 no.2
    • /
    • pp.119-124
    • /
    • 2014
  • Objective: The use of chemicals for building prosthetic sockets present the possibility of being hazardous and unsafe due to off-gassing. The purpose of the present study was to investigate if freshly made materials used in prosthetic sockets causes off-gassing that would penetrate the skin and cause damage to the kidneys or blood. Design: Cross-sectional study. Methods: In this research, the off-gassing effects during the initial curing process of styrene monomer, vinyl ester resin, epoxy methacrylate resin, benzene-1, 3-dimethaneamine, trimethylhexanedlamine, and paratertiarybutylphenol were analyzed. Acid detection strips were placed inside newly fabricated mock-prosthetic sockets and left overnight in a closed environment to find out if acid was present in the invisible fumes. The plastic was worn by 9 subjects and urinalysis was made after 48 hours to test for any kidney or blood toxicity of the resins. Results: After wearing the plastic cuff for 48 hours, the ratio of protein to creatinine in the urine was raised to an abnormal level in five out of nine subjects. Four out of the nine subjects showed normal protein to creatinine ratios after wearing the device. The results showed that damage to the kidney occurred from wearing the resins after curing in half of the subjects. Conclusions: It is very important to conduct patient intakes which includes the assessment of renal function. Off-gassing in vented chambers may be needed to protect both prosthetists and patients.

Evaluation of Plantarflexion Torque of the Ankle-Foot Orthosis Using the Artificial Pneumatic Muscle (인공공압근육 엑츄에이터를 이용한 족관절 보조기의 족저굴곡 토크 평가)

  • Kim, Kyung;Kwon, Tae-Kyu;Kang, Seung-Rok;Piao, Yong-Jun;Jeong, Gu-Young
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.6
    • /
    • pp.82-89
    • /
    • 2010
  • Ankle-foot orthosis with an artificial pneumatic muscle which is intended for the assistance of plantarfelxion torque was developed. In this study, power pattern of the device in the various pneumatics and the effectiveness of the system were investigated. The pneumatic power was provided by ankle-foot orthosis controlled by user‘s physiological signal, that is, muscular stiffness in soleus muscle. This pneumatic power can assist plantarflexion torque of ankle joint. The subjects performed maximal voluntary isokinetic plantarflexion motion on a biodexdynamometer in different pneumatics, and they completed three conditions: 1) without wearing the orthosis, 2) wearing the orthosis with artificial muscles turned off, 3) wearing the orthosis activated under muscular stiffness control. Through these experiments, we confirmed the effectiveness of the orthosis and muscular stiffness control using the analyzing isokinetic plantarflexion torque. The experimental results showed that isokinetic torques of plantarflexion motion of the ankle joints gradually increased in incremental pneumatic. The effectiveness of the orthosis was -7.26% and the effectiveness of the muscular stiffness control was 17.83% in normalized isokinetic plantarflexion torque. Subjects generated the less isokinetic torques of the ankle joints in wearing the orthosis with artificial muscles turned off, but isokinetic torques were appropriately reinforced in condition of wearing the orthosis activated under muscular stiffness control(17.83%) compared to wearing the orthosis(-7.26%). Therefore, we respect that developed powered orthosis is applied in the elderly that has weak muscular power as the rehabilitation equipment.