• Title/Summary/Keyword: Wear Out

Search Result 1,117, Processing Time 0.026 seconds

Sliding wear mechanism of the high-nitrogen austenitic 18Cr-18Mn02Mo-0.9N steel (고질소 Fe-18Cr-18Mn-2Mo-0.9N강의 미끄럼 마멸 기구)

  • Kim S. D.;Kim S. J.;Kim Y. S.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2005.10a
    • /
    • pp.105-108
    • /
    • 2005
  • Sliding wear mechanism of a high nitrogen austenitic 18Cr-18Mn-2Mo-0.9N steel has been investigated. Dry sliding wear tests of the steel were carried out at various loads of 1N-10N under a constant sliding speed condition of 0.15m/s against AISI 52100 bearing steel balls. Solution $(1050^{\circ}C)$ and isothermal aging $(900^{\circ}C)$ heat treatments were performed on the steel and the effect of the heat treatments on the wear were investigated. Wear rates of the solution-treated steel specimen remained low until 5N, and then increased abruptly at loads above 5N. The rates of isothermally aged specimens were low and increased gradually with the applied load. Worn surfaces, their cross sections, and wear debris of the steel specimens were examined with a scanning electron microscopy. Phases of the heat-treated specimen and the wear debris were identified using XRD. Phases transformed underneath the sliding track during the wear were investigated and analyzed using TEM. Effects of the phase transformation during the wear and $Cr_2N$ precipitates formed during the isothermal aging on the wear of the austenitic steel were discussed.

  • PDF

Wear resistance of indirect composite resins used for provisional restorations supported by implants

  • Tsujimoto, Akimasa;Jurado, Carlos;Villalobos-Tinoco, Jose;Barkmeier, Wayne;Fischer, Nicholas;Takamizawa, Toshiki;Latta, Mark;Miyazaki, Masashi
    • The Journal of Advanced Prosthodontics
    • /
    • v.11 no.4
    • /
    • pp.232-238
    • /
    • 2019
  • PURPOSE. The aim of this study was to investigate simulated localized and generalized wear of indirect composite resins used for implant supported provisional restorations. MATERIALS AND METHODS. The study investigated ten indirect composite resins. Two kinds of wear were simulated by 400,000 cycles in a Leinfelder-Suzuki (Alabama) machine. Localized wear was simulated with a stainless-steel ball bearing antagonist and generalized with a flat-ended stainless-steel cylinder antagonist. The tests were carried out in water slurry of polymethyl methacrylate beads. Wear was measured using a Proscan 2100 noncontact profilometer in conjunction with Proscan and AnSur 3D software. RESULTS. Both localized and generalized wear were significantly different (P<.05) among the indirect composite resins. SR Nexco and Gradia Plus showed significantly less wear than the other indirect composite resins. The rank order of wear was same in both types of wear simulation. CONCLUSION. Indirect composite resins are recommended when a provisional implant-supported restoration is required to function in place over a long period. Although only some indirect composite resins showed similar wear resistance to CAD/CAM composite resins, the wear resistance of all the indirect composite resins was higher than that of bis-acryl base provisional and polymethyl methacrylate resins.

Effects of Alloying Elements on the High Pressure Wear Characteristics of Ductile Cast Iron I-Cu, Mn (구상흑연주철의 고압하 마멸특성에 미치는 합금원소의 영향 I-Cu, Mn)

  • Bang, Woong-Ho;Kang, Choon-Sik;Park, Jae-Hyun;Kweon, Young-Gak
    • Journal of Korea Foundry Society
    • /
    • v.20 no.4
    • /
    • pp.230-239
    • /
    • 2000
  • High pressure wear characteristics of DCI(Ductile Cast Iron) were investigated through unlubricated pin-on-disc wear test. Wear test were carried out at speed of 23m/min, under pressure of 3MPa and 3.3 MPa. Cu and/or Mn were added to examine the effect of alloying elements on the high pressure wear characteristics of DCI. To investigate the relationship between wear characteristics and mechanical properties of DCI, Brinell hardness and V-notched Charpy impact energy were tested. Wear surface of each specimen was observed by SEM to determine the wear mechanism of DCI under high pressure wear condition. In the mild wear region, wear characteristics of alloyed DCI specimens were very similar to that of unalloyed DCI. But mild-severe wear transition was occurred at different wear distance and wear rate of DCI specimens were changed by alloying elements. In severe wear condition, wear rate of DCI was dramatically increased by the addition of Mn. Although the addition of Cu 0.46wt% did not decrease the wear rate of DCI in the severe wear region, but it delayed the mild-severe wear transition. Under high pressure wear condition, wear rate and mild-severe wear transition were not concerned with hardness of DCI specimens, but they were deeply associated with impact energy changed by alloying elements.

  • PDF

EFFECT OF T6 HEAT TREATMENT ON THE SCRATCH WEAR BEHAVIOR OF EXTRUDED Al-12WT.%Si ALLOY

  • YEON-JI KANG;JONG-HO KIM;JONG-IL HWANG;KEE-AHN LEE
    • Archives of Metallurgy and Materials
    • /
    • v.64 no.2
    • /
    • pp.617-622
    • /
    • 2019
  • This study investigated the effect of T6 heat treatment on the microstructure and scratch wear behavior of hypoeutectic Al-12wt.%Si alloy manufactured by extrusion. Microstructural observation identified spherical eutectic Si phases before and after the heat treatment of alloys (F, T6). Phase analysis confirmed Al matrix and Si phase as well as Al2Cu and Al3Ni, Mg2Si in both alloys. In particular, Al2Cu was finer and more evenly distributed in T6 alloy. This resulted in Vickers hardness of T6 alloy that was 2.3 times greater compared to F alloy. The scratch wear test was conducted using constant load scratch test (CLST) mode and multi-pass scratch test (MPST) mode. The scratch coefficient and worn out volume obtained by such were used to evaluate wear properties before and after heat treatment. In the case of T6 alloy, its scratch coefficient was lower than F alloy in all load ranges. After 15 repeated tests to measure worn out volume, F alloy and T6 alloy measured 1.2×10-1 mm3 and 7.8×10-2 mm3, respectively. In other words, the wear resistance of T6 alloy were confirmed to be better than those of F alloy. In addition, this study attempted to identify the microstructural factors that contribute to the better scratch wear resistance of T6 alloy and wear mechanism from surface and cross-section observations after the wear tests.

Clothing Condition of Elderly Men Focusing on Somatotype Variation and Satisfaction with Ready-to-Wear (노년 남성의 의복착용 실태조사 -체형 변화와 기성복 만족도를 중심으로-)

  • 김희영
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.22 no.2
    • /
    • pp.193-202
    • /
    • 1998
  • The purpose of this study was to understand clothing condition of elderly men focusing on somatotype variation and satisfaction with ready-to-wear and to provide basic data in designing ready-to-wrar for the elderly men. The questionnaire method was used and one-to-one interviews were held for the elderly residents in Seoul, Deajon, Jonju, and Yeosu areas. The total of 275 questionnaires (from 148 elderly men in the 60's, 99 in the 70's and 28 in the 80's) were collected and used for statistics. SAS package was used for the statistics and the statistics were based on frequency, X2-test, ANOVA, Duncan's multifle range test. The results of the study were as follows; 1) Height (p< .05), weight (p< .001) and Rohrer index (p< .05) decreased significantly with ageing 2) The somatotypes of 75.6% were changed and the 70's 8t the 80's showed significantly (p< .05) higher changing rate compared to the 60's and more changes took place significantly (p< .001) with ageing. 3) The most preferred out wear was suit & tie and next was jumper or shirt. 4) For the mode of getting suit, the highest number 55.3%) purchased ready-to-wear, next (32.0%) was tailored and the least (12.7%) neither purchased nor tailored. The percentage of buying ready-to-wear significantly (p< .01) decreased with ageing. The main reason for getting tailor-made was not well fitting of ready-to-wear (20.7% out of 32.0%). And for the mode of getting suit, there was significant differance with income (p< .001) and pocket money (p< .01). 5) The most important factors in suit and shirt werefirst, size (fitness) and second, comfort in movement. 6) For the wearing feeling of suit, 55.3% showed discomfort. There was significant difference according to the age (p< .05) and pocket money (p< .05). The Discomfort increased with ageing and less pocket money. 7) 62.4% answered it uneasy to Pick out well fitting If comfortable suit. This showed their dissatisfaction with ready-to-wear. 8) As for the items of not well fitting, 64.4% answered in jacket, 60.8% in trousers, 46.0% in shirt. The above result shows that elderly men's somatotype changes as they age, suit is found uncomfortable and it's not easy for elders to pick out comfortable ready-to-wear. So, they seem to have a certain dissatisfaction in ready to wear. Therefore, there is a need for reorganization of size and developing pattern design according to measurement of elderly men.

  • PDF

Wear Assessment for Non-asbestos Friction Material against Cast Iron Drum (비석면 마찰재의 주철제 드럼에 대한 마멸 평가)

  • 한성호;이성만;신두식;김석삼
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1996.04a
    • /
    • pp.117-121
    • /
    • 1996
  • Friction and wear test for non-asbestos material against cast iron drum were carried out to investigate the friction and wear characteristics of brake system. Its friction coefficient and wear volume were measured and compared with those of asbestos friction material. The experiment. was perforated tinder room temperature and various sliding conditions. After each experiment, the sin-faces of friction materials were observed by SEM.

  • PDF

The measurement of the amount of wear by using least squares approximation with Fourier series (푸리에 급수와 초소 자승법을 이용한 마멸량 측정)

  • 전종하;구영필;조용주
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1998.10a
    • /
    • pp.300-305
    • /
    • 1998
  • A method of calculating wear amount which is based on digitally measured surface profile was suggested. The original profile of worn out profile was estimated from its adjacent surface profile by using least squares curve fitting with Fourier series. The approximated curve was well fitted to original surface profile. With this approach, more accurate calculation of the wear amount will be possible.

  • PDF

Resistance to Abrasive Wear of Materials Used as Metallic Matrices in Diamond Impregnated Tools

  • Konstanty, Janusz;Kim, Tai-Woung;Kim, Sang-Beom
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09b
    • /
    • pp.1132-1133
    • /
    • 2006
  • Metal-bonded diamond impregnated tools are being increasingly used in the processing of stone and ceramics, road repair, petroleum exploration, etc. Although the main tool wear mechanisms have been identified, the scientific background is inadequate and fundamental research has to be carried out to better understand the tool field behaviour. This work addresses the complex issues of modelling abrasive wear of the metallic matrix under laboratory conditions. The generated data indicates that the matrix wear resistance can be assessed in a simple manner; whereas tests carried out on diamond impregnated specimens may aid prediction of the tool life in abrasive applications.

  • PDF

Tribological Behavior of Boundary Lubricated Sliding Surfaces Using Three Different Spacing of Surface Profiles

  • Oh, Se-Doo;Lee, Young-Ze
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.11
    • /
    • pp.1428-1434
    • /
    • 2002
  • The ball-on-disk type sliding tests with boundary lubricated steels were carried out to verify the effect of initial spacing in surface profiles on wear and scuffing. Three kinds of surface spacing, which are closely related with initial surface micro-cracks on sliding surfaces, were produced on AISI 1045 steel surfaces using different grinding and polishing processes. Frictional forces and time to scuffing were measured, and the shape and amount of wear particles were analyzed to compare the with original surface profiles. From the tests, it was confirmed that the size of wear particles are related closely to the original spacing of the surface profile. The time to failure and amount of wear were sensitive to the surface spacing. The wider surface spacing shows much longer sliding life and smaller amount of wear than the others. Time to scuffing was increased with increasing surface pro(lie spacing. The size of wear particles increased while the wear and wear rate K were decreased with an increase in surface spacing. After the sliding tests, surface cracks of inner parts of the wear track formed due to scuffing were observed and compared among the specimens having the different surface spacing.

The Friction and Wear of Boundary Lubricated Sliding Surfaces Using Three Different Surface Profile Spacing (경계윤활에서 표면의 스페이싱에 따른 마찰 및 마멸 특성)

  • 오세두;이영제
    • Tribology and Lubricants
    • /
    • v.17 no.5
    • /
    • pp.399-405
    • /
    • 2001
  • In this paper the ball-on-disk type sliding tests with boundary lubricated steels were carried out to verify the relation between surface profiles and wear as well as scuffing. Three kinds of surface roughness and asperity radius were produced on AISI 1045 steels using the different processes of grinding and polishing. Frictional forces and time to scuffing were measured. Also, the shape and amount of wear particles were analyzed to compare with original profiles. From the tests, it was confirmed that the size of wear particles are very related to original surface profile. The time to failures and wear amounts were sensitive to the surface spacing. The large surface spacing shows much longer sliding life and smaller wear amount than the others. Time to scuffing was increased with increasing surface profile spacing. The sire of wear particles was increased and the amount was decreased with increasing surface profile spacing. Wear volume and wear rate K were decreased with increasing surface profile spacing. And after sliding tests, surface cracks of inner parts of the wear track occurred scuffing were observed and compared the differences about each specimen having the different surface profile spacing.