• Title/Summary/Keyword: WaveOne Motor

Search Result 60, Processing Time 0.037 seconds

Vibration characteristics of endodontic motors with different motion: reciprocation and conventional rotation (왕복운동 및 회전운동 근관성형용 전동모터 간의 진동 양상 비교)

  • Jeon, Yeong-Ju;Kim, Jin-Woo;Cho, Kyung-Mo;Park, Se-Hee;Chang, Hoon-Sang
    • The Journal of the Korean dental association
    • /
    • v.52 no.12
    • /
    • pp.734-743
    • /
    • 2014
  • Objectives: By introduced reciprocation motion file in dentistry, dentists benefit simple canal shaping procedure and time-saving. But, reciprocation motion generates uncomfortable vibration to doctors and patients. Because there was no study about this consideration, this study compared vibration pattern and power generated from reciprocation motion motor and conventional rotary motor. Materials & Methods: One conventional rotary motor; X-Smart (Dentsply Maillefer, Ballaigues, Switzerland); and two reciprocating motors; WaveOne Motor (Dentsply Maillefer, Ballaigues, Switzerland) and X-SMART PLUS (Dentsply Maillefer, Ballaigues, Switzerland); were used in this study. Triaxial $ICP^{(R)}$ Accelerometer (Model 356A12, PCB piezotronics, New York, USA) was attached on motor's handpiece head, and was measured tri-axial vibratory acceleration with NI Sound and Vibration Assistant 2009 software (National Instruments, Texas, USA). Mean vibratory acceleration and maximum vibratory acceleration was measured on fixed position and handed position. The results of vibratory acceleration were statistically analyzed using ANOVA and multiple comparisons are made using Turkey's test at p<0.05 level. Results: Reciprocating motors showed higher mean vibratory acceleration and maximum vibratory acceleration than conventional rotary motor (p<0.05). Between reciprocating motors, X-SMART PLUS had lower mean vibratory acceleration and maximum vibratory acceleration than WaveOne Motor (p<0.05). Conclusion: Reciprocating motors generate more vibration than conventional rotary motor. Further study about effect of vibration to dentist and patient is needed. And it seems to be necessary to make a standard about vibration level in endodontic motors.

Stability Evaluation of One-Dimensional Flow in Solid Rocket Motors Based on Computational Fluid Dynamics

  • Kato, Takashi;Hanzawa, Masahisa;Morita, Takakazu;Shimada, Tbru
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2004.03a
    • /
    • pp.565-572
    • /
    • 2004
  • Numerical stability analysis of one-dimensional axial flow in solid rocket motors is performed based on the Euler equation coupled with an unsteady combustion equation of solid propellant. In order to check the numerical scheme, behavior of a standing wave in a closed tube is examined. A standing wave in solid rocket motor decays or grows depending on the total effect of propellant combustion, nozzle flow, and so on. The stability boundary of the fundamental mode standing wave is determined by changing one of the combustion parameters. In addition growth rates of the wave are calculated numerically in relatively low Mach number flow region for the motors with different port and nozzle throat diameters. The results obtained here agree well with the approximate solution. The same scheme is applied to a motor with shorter length and L*-instability is observed.

  • PDF

Research for Step Motor using Piezoelectric Torsional Actuator (압전회전작동기를 이용한 스텝모터에 관한 연구)

  • Kim, Jun-Hyuk;Chung, Dal-Do;Kim, Jae-Hwan
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.279-282
    • /
    • 2004
  • In this paper, A new type of piezoelectric step motor using piezoelectric torsional actuator and a pair of one-way clutch bearing is designed, manufactured and tested. The torsional actuator consists of 16-polygonal tube that can produce angular displacement using shear mode of piezoceramic. One-way clutch bearing convert oscillation of torsional actuator into continuous rotation. After performance testing of torsional actuator, the optimum condition for driving motor is investigated in terms of wave shape, excitation frequency and electrical field. The performance of the motor is experimentally evaluated. As a result, square wave has larger rotation speed than sin wave, and the maximum rotation speed of 57 rpm is measured at 3850 Hz and 100V/mm.

  • PDF

Changes in EEG According to Attention and Concentration Training Programs with Performed Difference Tasks (주의·집중훈련 프로그램의 두 가지 과제수행에 따른 뇌파 변화)

  • Chae, Jung-Byung
    • PNF and Movement
    • /
    • v.12 no.2
    • /
    • pp.97-106
    • /
    • 2014
  • Purpose: The purpose of this study was to investigate changes in EEG through attention. Concentration training and performing tasks are important factors in the improvement of motor learning ability. Methods: In the experiment, 22 healthy people were divided into two groups: the trail making test (TMT) group and the computerized neurocognitive function test (CNT) group. A one-way Neuro Harmony M test to see whether there was a significant difference among the groups. Results: The TMT group showed a significant increase in ${\alpha}$ wave, ${\alpha}$ wave sequence, and ${\beta}$ wave sequence; however, there were no significant differences in SMR wave, SMR wave sequence, and ${\beta}$ wave. The CNT group showed increases in ${\alpha}$ wave, ${\alpha}$ wave sequence, SMR wave, SMR wave sequence, and ${\beta}$ wave sequence; however, there was no significant difference in ${\beta}$ wave. In EEGs before and after two performance tasks were changed, there were significant differences in ${\beta}$ wave, SMR wave, SMR wave sequence; however, there were no significant differences in ${\alpha}$ wave sequence, ${\beta}$ wave, and ${\beta}$ wave sequence. Conclusion: Attention training and concentration training offer feedback and repetition for constant stimulus and response. Moreover, attention training and concentration training can contribute to new studies and motivation by developing fast sensory and motor skills through acceptable visual and auditory stimulation.

An Experimental Study on Elastic Wave Propagation in a Symmetrically Filament-Wound Composite Motor Case (대칭 적층 복합재 연소관의 탄성파 전파에 관한 실험적 연구)

  • Song, Sung-Jin;Choe, Ji-Ung
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.18 no.3
    • /
    • pp.191-204
    • /
    • 1998
  • One of the key issues in acoustic emission (AE) during hydroproof test of filament-wound composite rocket motor cases is the determination of the optimal component of elastic wave to be monitored. To solve this problem, broadband ultrasonic wave was generated into a symmetrically filament-wound composite motor case, and was received at 105 different locations after the propagation through the composite case with different distances and directions. By analysis of the received signals, characteristics of elastic wave propagation such as frequency components, the maximum propagating distance, and velocity surface were investigated. This analysis was performed for two different conditions of the motor case; air-filled and hydraulically pressurized. Based on these information, the effect of hydraulic pressure on the wave propagation characteristics was investigated and furthermore, the optimal component of elastic wave for AE during hydroproof test of the motor case was successfully determined.

  • PDF

Design and Analysis of a L shape two touch point ultrasonic rotary motor (L형 2타점 회전모터의 설계와 해석)

  • Kim, Sung-Hyun;Park, Tae-Gone
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.85-88
    • /
    • 2004
  • The piezoelectric ceramic is attached between 'L' type guide and 'L' type stator, This motor has rotary motion which is operated by longitudinal and bending mode. The basic structure of the two kinds of type motor that called one stator motor, two stator motor is same but we suggested a few parameters for considering their stator design and characteristics. As a result, the two stator type motor is much more useful than one stator type motor for hi-direction rotation.

  • PDF

Design and Analysis of a L shape two touch point ultrasonic rotary motor (L형 2타점 회전모터의 설계와 해석)

  • Kim, Sung-Hyun;Kim, Hang-Sik;Park, Tae-Gone
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1649-1651
    • /
    • 2004
  • The piezoelectric ceramic is attached between 'L' type guide and 'L' type stator. This motor has rotary motion which is operated by the travelling wave. The basic structure of the two kinds of type motor that called one stator motor, two stator motor is same but we suggested a few parameters for considering their stator design and characteristics. As a result, the two stator type motor is much more useful than one stator type motor for bi-direction rotation.

  • PDF

Research for Stepping Motor Using Piezoelectric Torsional Actuator (압전회전작동기를 이용한 스텝모터에 관한 연구)

  • Kim Jun Hyuk;Kim Jaehwan;Chung Dal Do
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.4 s.97
    • /
    • pp.499-505
    • /
    • 2005
  • In this paper, a new type of pi+ezoelectric stepping motor is designed, manufactured and tested. This motor is composed of piezoelectric torsional actuator and a pair of one-way clutch bearings. The torsional actuator consists of 16-polygonal tube of piezoceramic that can produce an angular displacement associated with shear mode. One-way clutch bearing converts oscillation of torsional actuator into a continuous stepping rotation. The proposed stepping motor does not require any conversion mechanism for stepping motion like any other motors. In the design process, the shear resonance mode of piezoelectric actuator is analyzed by using a commercial finite element analysis program, and the performance of the fabricated torsional actuator is measured. $0.124^{\circ}$ of maximum angular displacement is measured in square wave excitation on the actuator only. The stepping motor is manufactured by assembling a pair of one-way clutch bearings and the torsional actuator. The maximum rotation speed of 72rpm and the blocking torque of 3.136 mNm are measured at 3540 Hz and 100V/mm. Once the proposed piezoelectric stepping motor is miniaturized, it can be used for many compact and precise moving applications.

Stepping motor controlling apparatus

  • Le, Ngoc Quy;Jeon, Jae-Wook
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1858-1862
    • /
    • 2005
  • Stepping motor normally operates without feedback and may loss the synchronization. This problem can be prevented by using positional feedback. This paper introduces one method for closed loop control of stepping motor and a method for combining full-step control and micro-step control. This combination controlling apparatus can perform position control with high accuracy in a high speed, so that it will not suffer from vibration (or hunting) problem when stopping motor. Controlling apparatus contains a position counter block for detecting rotor position of stepping motor, a driving block for supplying current to windings of stepping motor, a control block for comparing output signal of position counter block with command position (desired position) and outputting current command signal based on deviation between current position and command position of rotor. To output current command signal, the control block refers to a sine wave data table. This table contains value of duty cycle of Pulse Width Modulation signal. As the second object of this paper, the process of building this data table is also presented.

  • PDF

The Effect of Glide Path on Canal Centering Ability in Reciprocating File System (Reciprocating 파일 시스템에서 Glide Path가 근관만곡도 유지에 미치는 영향)

  • Zang, Ki-Choul;Kim, Jin-Woo;Cho, Kyung-Mo;Park, Se-Hee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.3
    • /
    • pp.245-252
    • /
    • 2012
  • The purpose of this study was to evaluate the influence of glide path on canal centering ratio after instrumentation with different single file systems; WaveOne and Reciproc. Reciproc R25 (VDW), WaveOne Primary (Dentsply Maillefer) and PathFile #13, 16, 19 (Dentsply Maillefer) were used in this study. In no glide path groups, Reciproc files and WaveOne files used for canal preparation without glide path. In glide path groups, the PathFile were used before canal preparation. Methylene blue dye was introduced into the canal to obtain a clear pre-instrumentation image. Pre-instrumentation images and post-instrumentation images were scanned using Epson Perfection V700 Photo scanner (Epson, Nagano, Japan). Transparencies of post-instrumentation images were changed and superimposed on pre-instrumentation images using Adobe Photoshop CS 3 (Adobe Systems Incorporated, San Jose, CA, USA). The centering ratio was calculated for each instrumented canal using the following formula: CR=|X1-X2|/Y. It was statistically analyzed using two-way ANOVA at 95% confidential level. The centering ratio in glide path groups were significant less than it in no glide path groups at 3, 4, 5 and 6 mm level. Except 1 and 6 mm level, WaveOne groups had significant less centering ration than Reciproc groups. At 6 mm level, there was no significant difference between WaveOne and Reciproc. In the limitation of this study, creation of a previous glide path before reciprocating motion instrumentation in curved canal appears to be appropriate and WaveOne system can be used for preparation of curved canal without severe aberrations.