A Study on the Waterproofing for Wet Structure Use of Room Temperature Vulcanization(RTV) Synthetic Rubber Sheet (상온가황형 합성고무시트를 이용한 습윤구조물 방수에 관한 연구)

  • 박동협;김영근;신주재;이대우
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 한국콘크리트학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.545-548
    • /
    • 2003
  • The purpose of this study is measures vulcanization properties of matter by time of room temperature vulcanization synthetic rubber sheet and the evaluation adhesive properties tested by concrete surface moisture. Also, Its estimated reaction mechanism and adhesion performance between protection mortar and waterproofing layer. The results showed that vulcanization progressed in room temperature and adhesion intensity increased regardless of moisture condition.

  • PDF

A Study on Quality Control of Waterproof Agent and Admixture of Cement for Concrete Surface Treatment (콘크리트 표면처리용 시멘트 액체방수제의 품질관리에 관한 연구)

  • 최은수;곽규성;배기선;오상근;안상덕
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 한국콘크리트학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.181-188
    • /
    • 2000
  • This study deals with the method of test for waterproof agent and admixture of cement, and especially, the effect in bond strength between waterproofing layer and mortar of concrete substrate in building construction. The purpose of this study is that it makes the estimation value of bond strength of concrete wall and anticorrosive when coated waterproof agent and admixture of cement as waterproofing materials for durability performance estimation depend on concrete watertighness.

  • PDF

Hydrostatic Pressure Resistance Performance Testing of Cement Mixed Siliceous Powder Waterproofing Coationgs (규산질계 분말형 도포방수재의 내투수성 성능평가 연구)

  • Park, So-Young;Kwon, Si-Won;Kim, Soo-Yeon;Kim, Byong-il;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 한국건축시공학회 2018년도 추계 학술논문 발표대회
    • /
    • pp.31-32
    • /
    • 2018
  • Lately, cement mixed siliceous powder waterproofing coating has been used as a waterproofing material in the wet environment condition of an underground concrete structure. Underground is exposed to environmental influences such as pressure of ground water, pressure of soil. However, the quality standard for pressure (water pressure, earth pressure) is not specified in the specification of the cement mixed siliceous powder waterproofing coating. Therefore, in this study, the permeability test was carried out based on the assumption that the durability should be verified in consideration of the environmental aspects of the material in actual field. As a result of the test, the permeability was generated from the inorganic single type material, but it was caused by the sealing failure and the test error, and the permeability was not generated in most of the materials. The results of this study will be analyzed by reviewing the physical properties of the material, and the research direction will be resumed.

  • PDF

A Study on a Performance evaluation for Quality Liguid Siliceous of Waterproof agent (액상형 규산질계 침투성 방수재의 성능평가에 관한 연구)

  • Kang, Hyo-Jin;Kwon, Shi-Won;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 한국건축시공학회 2003년도 학술.기술논문 발표회
    • /
    • pp.63-67
    • /
    • 2003
  • There are many factors that generate the early deterioration of the concrete structure. As the one of the representative factors, we can think an invasion of the water, air and so on. The water and air invade in inside void along the capillarity and they become the cause that the durability like corrosion of layer department due to freezing and thawing, inside steel frame corrosion, and so on blacks. Therefore with covering permeability covering waterproofing material of fluid condition in outer wall, intercepting the deterioration factor due to the infiltration of water from outside and for salt damage of concrete layer department, freezing damage and neutralization, it needs, to improve durability of structure. This study separately examined physical and chemical specific of quality liguid siliceous of waterproofing material. Therefore as this applys the construction site, it improves the durability of concrete structure. Further this presents the application plan from the construction market against the new material.

  • PDF

Research on Materials Characteristics of high adhesive Self Adhesion Waterproofing Material using by the Eco-friendly Resource Recycling and Resource Waste (친환경 자원재활용 재료와 폐자원을 이용한 고점착 자착식 방수시트재의 재료적 특성에 관한 실험적 연구)

  • Heo, Neung-Hoe;Choi, Eun-Gyu;Kim, Su Ryon;Kim, Jin-Sung;Lee, Jong-Yong;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 한국건축시공학회 2012년도 춘계 학술논문 발표대회
    • /
    • pp.291-293
    • /
    • 2012
  • Recently, environmental pollution and global warming and greenhouse gases are increasing, because Efforts to improve are continued throughout the world. As part of the resource recycling industry has become an important research area. In the field of waterproofing industry, focus on the resource recycling is growing, due to serious resource depletion and sharp price. Therefore, in this research on the resource recycling such as reclaimed rubber and rubber waste is enable and these eco-friendly materials are applied high adhesive flexible non-exposed type self adhesion compound waterproofing material was measured eco-friendly performance and field application was evaluated.

  • PDF

A Study on a Performance evaluation for Quality Liguid Siliceous of waterproof agent (액상형 규산질계 침투성 방수재의 성능평가에 관한 연구)

  • 강효진;권시원;오상근
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 한국건축시공학회 2003년도 학술.기술논문발표회
    • /
    • pp.63-67
    • /
    • 2003
  • There are many factors that generate the early deterioration of the concrete structure. As the one of the representative factors, we can think an invasion of the water, air and so on. The water and air invade in inside void along the capillarity and they become the cause that the durability like corrosion of layer department due to freezing and thawing, inside steel frame corrosion, and so on blacks. Therefore with covering permeability covering waterproofing material of fluid condition in outer wall, intercepting the deterioration factor due to the infiltration of water from outside and for salt damage of concrete layer department, freezing damage and neutralization, it needs to improve durability of structure. This study separately examined physical and chemical specific of quality liquid siliceous of waterproofing material. Therefore as this applys the construction site, it improves the durability of concrete structure. Further this presents the application plan from the construction market against the new material.

  • PDF

Improvement of Watertightness Evaluation Method in Waterproof Membrane (복합계 멤브레인 방수층의 수밀성 시험 평가방법 개선방안 연구)

  • Kim, Meong-Ji;Seon, Yun-Suk;Kim, Soo-Yeon;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 한국건축시공학회 2018년도 추계 학술논문 발표대회
    • /
    • pp.50-51
    • /
    • 2018
  • Although the introduction of new materials and new construction methods and overseas materials has become more active due to the diversification of the construction market, the quality standards of waterproofing methods in Korea are insufficient. In particular, the quality control standard is applied to the KS F 2622:08 (Membrane Waterproofing layer performance test method), which is the existing standard, to prepare standards for quality control of waterproof materials, which is increased in Korea.

  • PDF

A Study on Absorption Amount of Water-Repellency Processed Non-Woven Fabric in PVC Composite Waterproofing Sheet of A Multi-Layer Structure (다층막 구조형 PVC 복합방수시트 내 발수 처리된 부직포의 흡수량에 관한 연구)

  • An, Ki-Won;Heo, Neung-Hoe;Oh, Je-Gon;Go, Gun-Woong;Go, Jang-Ryeol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 한국건축시공학회 2014년도 추계 학술논문 발표대회
    • /
    • pp.163-164
    • /
    • 2014
  • This study is conducted for prevent spread of penetration water and water leakage through non-woven fabric between PVC sheet and PVC sheet in the PVC composite waterproofing sheet of a multi-layer structure. For this, carry out absorption amount test to confirm spread resistance performance after manufacturing PVC composite waterproofing sheet of a multi-layer structure using water-repellency processed non-woven fabric. As a result of test, weight of water-repellency processed non-woven fabric increased to 1.178g, Compared with beginning and there are not penetration water.

  • PDF

Adhesion Performance Change of Positive-side Installed Rubber Asphalt Waterproof Sheet Integrated with Water-Soluble Film in Accordance to Wetness Condition (수용성 필름이 일체화된 역타설 고무 아스팔트 방수시트의 콘크리트 타설시 가수 여부에 따른 부착성능 변화 연구)

  • An, Ki-Won;Kang, Hyo-Jin;Kim, Chun-Hag;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 한국건축시공학회 2019년도 추계 학술논문 발표대회
    • /
    • pp.229-230
    • /
    • 2019
  • Integrated water-soluble film is dissolved in the rubber asphalt waterproof sheet to secure adhesive strength on freshly cast concrete on the adhesion side of waterproofing layer on the floor slab. In addition, in order to determine whether the water in the concrete slurry can dissolve the water-soluble film sufficiently, the adhesive strength of the waterproofing sheet was compared between difference wetness condition at the upper part of the concrete specimen before the concrete casting.

  • PDF

Analysis of the effect of preventing breakage by formation of the joint insulation structure in the coating-sheet composite waterproofing method (도막-시트 복합방수공법에서의 접합부 절연구조 형성을 통한 파단방지 효과 분석)

  • Choi, Sung-Min;Oh, Sang-Keun;Park, Jin-Sang;Kim, Dong-Bum;Park, Wan-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 한국건축시공학회 2021년도 봄 학술논문 발표대회
    • /
    • pp.4-5
    • /
    • 2021
  • In this study, in the coating-sheet composite waterproofing method, a specimen was formed to prevent the transmission of the no-node tensile stress occurring under the junction between sheets by forming an insulating structure when the junction was formed, and to compare the effect of preventing breakage with the existing common junction. For this, tensile performance evaluation was conducted. As a result of the evaluation, it was confirmed that it exhibited higher tensile strength compared to the existing joint and at the same time exhibited a large width of displacement characteristics, and thus, had an effect of preventing breakage.