Acknowledgement
본 논문은 2021년 국토교통부 국토교통기술촉진연구사업의 연구비지원(21CTAP-C152047-03)에 의해 수행된 연구임을 밝히며 이에 감사를 드립니다.
In this study, in the coating-sheet composite waterproofing method, a specimen was formed to prevent the transmission of the no-node tensile stress occurring under the junction between sheets by forming an insulating structure when the junction was formed, and to compare the effect of preventing breakage with the existing common junction. For this, tensile performance evaluation was conducted. As a result of the evaluation, it was confirmed that it exhibited higher tensile strength compared to the existing joint and at the same time exhibited a large width of displacement characteristics, and thus, had an effect of preventing breakage.
본 논문은 2021년 국토교통부 국토교통기술촉진연구사업의 연구비지원(21CTAP-C152047-03)에 의해 수행된 연구임을 밝히며 이에 감사를 드립니다.