• 제목/요약/키워드: Waterproofing Performance

검색결과 224건 처리시간 0.019초

초속경화(初速硬化) 폴리우레아수지 도막방수재(途膜防水材)의 방수(防水)·방식(防蝕) 성능평가(性能評價)에 관한 연구(硏究) (A Study on Waterproofing and Anticorrosive Performance Evaluation of Polyurea Resin Waterproofing Membrane Coating of Velocity per Second Hardening)

  • 조찬행;강효진;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2003년도 학술.기술논문 발표회
    • /
    • pp.91-95
    • /
    • 2003
  • There is a problem to be solved for improvement of durability and safety supervision. When you do the waterproofing and anticorrosive work of main concrete from the design stage, the material and method of construction need to be correctly applied to appropriate circumstance conditions. Epoxy have mostly been used for concrete water tank structure. Lately, lots of subjects on adaption of polyurea resin waterproofing and anticorrosive are under discussion. Then, we attempt to approach by evaluating and comparing every capabilities with another waterproofs in this study. Performance evaluation items include the adherence performance, the imprint of seal performance, temperature dependence performance, promotion weatherizing ability, inner chemical performance, drinking water eruptive performance. Through the experiment analysis, we found that the polyurea resin waterproofing membrane is dominantly superior to other waterproofs. According to this study, we suggest the polyurea resin waterproofing membrane as a new waterproofing material for concrete structure.

  • PDF

초속경화 폴리우레아수지 도막방수재의 방수.방식 성능평가에 관한 연구 (A Study on Waterproofing and Anticorrosive Performance Evaluation of Polyurea Resin Waterproofing Membrane Coating of Velocity per Second Hardening)

  • 조찬행;강효진;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2003년도 학술.기술논문발표회
    • /
    • pp.91-95
    • /
    • 2003
  • There is a problem to be solved for improvement of durability and safety supervision. When you do the waterproofing and anticorrosive work of main concrete from the design stage, the material and method of construction need to be correctly applied to appropriate circumstance conditions. Epoxy have mostly been used for concrete water tank structure. Lately, lots of subjects on adaption of polyurea resin waterproofing and anticorrosive are under discussion. Then, we attempt to approach by evaluating and comparing every capabilities with another waterproofs in this study. Performance evaluation items include the adherence performance. the imprint of seal performance, temperature dependence performance. promotion westernizing ability, inner chemical performance. drinking water eruptive performance. Through the experiment analysis, we found that the polyurea resin waterproofing membrane is dominantly superior to other waterproofs. According to this study, we suggest the polyurea resin waterproofing membrane as a new waterproofing material for concrete structure.

  • PDF

멤브레인 방수층 성능 및 평가방법에 관한 기초적 연구 (A Basic Study on Evaluation Method and Performance of Membrane Waterproofing Layer)

  • 오미현;권시원;강효진;정희원;최인성;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2003년도 학술.기술논문 발표회
    • /
    • pp.17-21
    • /
    • 2003
  • This study is mainly acceptive for physical material performance than waterproofing layer performance on the external condition after construction. The reason are legalized only for material performance quality standard even though it is existed waterproofing materials for membrane. In actuality, waterproofing layer are greatly occurred in performance a decreased developing essential element that are human footprints as a result physical perimeter environment after construction and on the construction. As the result, this present paper purpose for evaluation and performance of the membrane waterproofing layer on the construction.

  • PDF

멤브레인 방수층 성능 및 평가방법에 관한 기초적 연구 (A Basic Study on Evaluation Method and Performance of Membrane Waterproofing Layer)

  • 오미현;권시원;강효진;정희원;최인성;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2003년도 학술.기술논문발표회
    • /
    • pp.17-21
    • /
    • 2003
  • This study is mainly acceptive for physical material performance than waterproofing layer performance on the external condition after construction. The reason are legalized only for material performance duality standard even though it is existed waterproofing materials for membrane. In actuality, waterproofing layer are greatly occurred in performance a decreased developing essential element that are human footprints as a result physical perimeter environment after construction and on the construction. As the result, this present paper purpose for evaluation and performance of the membrane waterproofing layer on the construction.

  • PDF

뿜칠형 초속경화 폴리우레아수지 도막방수재의 성능평가에 관한 연구 (A Study on Waterproofing Performance Evaluation of Polyurea Resin Waterproofing Membrane Coating of Velocity per Second Hardening)

  • 오상근;김수련;이성일
    • 한국건축시공학회지
    • /
    • 제2권1호
    • /
    • pp.131-138
    • /
    • 2002
  • There is a problem to be solved for improvement of durability and safety supervision. When you do the waterproofing work of main concrete from the design stage, the material and method of construction need to be correctly applied to appropriate circumstance conditions. Epoxy have mostly been used for concrete water tank structure. Lately, lots of subjects on adaption of polyurea resin waterproofing and anticorrosive are under discussion. Then, we attempt to approach by evaluating and comparing every capabilities with another waterproofs in this study. Performance evaluation items include the adherence performance, the imprint of seal performance, temperature dependence performance, promotion weatherizing ability, Inner chemical performance. drinking water eruptive performance. Through the experiment analysis, we found that the polyurea resin waterproofing membrane is dominantly superior to other waterproofs. According to this study, we suggest the polyurea resin waterproofing membrane as a new waterproofing material for concrete structure.

지하 콘크리트 구조물의 거동에 대한 방수층의 대응성 평가에 관한 실험적 연구 (Performance Test Method on the Influence Waterproofing as Behavior of Concrete Structure)

  • 노종수;권시원;곽규성;권기주;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2004년도 학술대회지
    • /
    • pp.77-81
    • /
    • 2004
  • The massive structures are not free to move with vibration, differential settlement, thermal stresses because, construction and expansion joint, crack etc., can be large enough to cause leakage as deformation of waterproofing. It has been depended on the test method of tensile/tear strength which is waterproofing performance as behavior of concrete structure crack. However, not to practically confirm the creep applied to concrete surface, even waterproofing membrane have more performance than definite strength and elasticity. Therefore, in this study will focus on the test method to consider a resistance performance about loose adhesion and deformation of waterproofing and behavior of concrete structure as construction/expansion joint, crack. Performance test method on the influence as behavior of concrete structure crack is to choose waterproofing materials and construction method which possible to confront with behavior of 50mm crack in the atmosphere and low temperature. Examine the deformation of waterproofing membrane and loose adhesion which can occur to structure in general job site, suggest standard testing method to analyze correlation waterproofing membrane and structure with 5-types of materials used in this study, such as Adhesion membrane and sheet complex, sheet and urethane complex, self-adhesive sheet, spray poly-urea, spray membrane of rubberized Asphalt.

  • PDF

누수보수용 주입형 실링재의 시공 기준에 관한 실험적 연구 (An Experimental study on the Construction Standard for Sealer of Injection Type for Leakage Maintenance)

  • 임민찬;조일규;선윤숙;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2005년도 추계 학술논문 발표대회
    • /
    • pp.51-54
    • /
    • 2005
  • The concrete structure hasn't perfect waterproofing performance but if it doesn't have a joint part that could isolate a permeability. Concrete structure(communication tunnel and underground structure) has an expansion joint and construction joint. There are a lot of joint type after construction or expansion, shrinkage, vibration, over load, performance of decline etc.. they offer a water of way by variety change. In this reason, It carries in effect a waterproofing work for the concrete structure of waterproofing. but the structure has a behavior that cause a problem by waterproofing layer of damage, heaving phenomenon, temperature of shrinkage. In this study, we will estimate a field of application for Sealer of injection type for leakage maintenance of construction standard on the waterproofing performance.

  • PDF

바닥판 조건에 따른 교면방수 시스템의 인장접착 특성 (Tensile Adhesive Characteristics of Waterproofing System for Concrete Bridge Decks)

  • 이병덕;박성기;심재원;정해문;김광우
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.373-378
    • /
    • 2002
  • The waterproofing system's performance is known to show a determining by complex interaction of material factors, design details, and the qualify of construction, and the waterproofing integrity of waterproofing membranes is determined by the bond to the deck and the amount of damage to the waterproofing membrane. In this research, the basic properties of waterproofing membranes on market and the tensile adhesive characteristics of waterproofing systems of concrete bridge deck have also been investigated in the view of the damages frequently reported from job site. As a results of tensile adhesive strength of waterproofing system, tensile strength is decrease with surface moisture contents except for inorganic-elastomeric liquid waterproofing membrane, and increase with strength of deck slab. Also tensile adhesive strength is generally increase in case of moisture curing of specimen because of pore structure and surface leveling. The after asphalt concrete paving tends to increase more than before those. The results of the liquid waterproofing membranes are upside-down, and the more concrete has strength, the more strength of tensile adhesive increase. The ambient temperature and the rolling temperature of asphalt concrete when application of the waterproofing membrane has considerable influence on the performance of waterproofing system.

  • PDF

건축물 옥상방수층의 누수보수를 위한 방수층재형성 주입기술에 관한 연구 (Study on the injecting technology of waterproofing layer for water leakage repair of roof)

  • 배기선;조일규;장혁수;곽규성
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2002년도 학술.기술논문발표회
    • /
    • pp.23-27
    • /
    • 2002
  • Waterproofing is one of the important factor to improve performance of building elements. But existing repair system for waterproofing have many problems like a damage of waterproof layer due to movement of concrete substrate, blistering effect and moisture condition. So waterproofing layer can not play an important part to improve waterproofing function and performance of building. Therefore, new waterproofing system to solve these problems of existing waterproofing system is developed. In this paper, new waterproofing system in water-leakage repair for remodeling is introduced

  • PDF

계열별 교면 방수시스템의 품질관리 지침(안) 고찰 (Quality Control Recommendation with Waterproofing Membrane Type of Waterproofing System for Concrete Bridge Decks)

  • 이병덕;박성기;심재원;정해문;김광우
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.367-372
    • /
    • 2002
  • The waterproofing systems of concrete bridge deck are installed under the complex circumstances, such as traffic loading, weather, and the condition of the deck concrete. For assuring the effectiveness of waterproofing system, the materials and the construction method and timing ought to be suitably selected with the procedures of waterproofing and the system has to ensure the economical performances. First of all, we discussed whether the quality and performance criteria for highway bridge deck are resonable or not through the investigation of domestic and foreign criteria. The basic properties of waterproofing membranes on market and the performance of waterproofing systems of concrete bridge deck have also been investigated in the view of the damages frequently reported from job site. In this way, the causes and measures of damages, the guidelines of design, construction, quality control, and maintenance, the test methods and criteria of membranes and waterproofing system, are proposed.

  • PDF