• Title/Summary/Keyword: Waterproofing Method

Search Result 206, Processing Time 0.023 seconds

The Automatic equipments Non-Exposure waterproofing method of reduced construction hours integrated with the improved URE-Sheet and UREPALT adhesives (우레팔트 접착제를 사용한 개량형 우레시트 일체식 공기단축형 기계화 시공 비노출 방수공법)

  • Min, Sung-Woo;Oh, Chang-Won;Yang, Jae-Bong
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2009.05c
    • /
    • pp.135-141
    • /
    • 2009
  • This technology is able to construct with hardening UREPALT adhesives and TPO URE-Sheet simultaneously using automatic equipments. the benefit of this construction method is that The layer of waterproofing is uniform and defect of construction would be reduced because of no construction joints between UREPALT adhesives and TPO URE-Sheet. Furthermore, this new method could accomplish shortening of construction period, quality control and saving of labor costs. Also the non-exposure waterproofing method would be protected from fire and safe for workers without using a torch.

  • PDF

A Study on Technology for Leakage Prevention of Concrete Construction by Flexible Type Waterproofing with Adhesive and Swelling Properties (점착.팽창성 유연형 도막방수재를 이용한 콘크리트 구조물의 누수방지 기술에 관한 연구)

  • 최성민;김종복;장혁수;오상근
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.04a
    • /
    • pp.768-773
    • /
    • 1999
  • This study of concrete movement confronting a scope inspects the problems about the waterproofing method and leakage/repairment at present and research the mechanism with the variety of applying examples introducing adhesion and inflation using the flexible type of waterproofing and repairement and the subsititution method developed with polymer resign composite. The polymer resign transmited into adhesion or inflation materials under wet environment absorbs adjoining moisture, wraps impurities of concrete surface, get the waterproofing layer and concrete surface adhere toughly, reorganize the impaired waterproofing layer and get over the detachment of it from concrete surface.

  • PDF

An Experimental Study on the Roofing Waterproofing Method Combined Soft and Hard Rapid Hardening Membrane (연질 및 경질 초속경도막방수재를 복합화한 옥상노출방수공법에 관한 실험적 연구(균열 대응성))

  • Choi, Eun-Gyu;Seo, Hyun-Jae;Lee, Jung-Hun;Lee, Sun-Gyu;Song, Je-Young;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.11a
    • /
    • pp.177-178
    • /
    • 2018
  • In the case of conventional ultra-fast hardness membrane waterproofing material (polyurea, etc.), damage such as breakage or tearing occurred frequently at the time of cracking of the surface after waterproofing. In this study, it is suggested that a waterproof layer can not cope with the occurrence of cracks at the same time by applying the soft type waterproofing material of soft type at the lower part of the construction method (securing of elongation) To minimize the possibility of water resistance.

  • PDF

A Study of proposal for Waterproofing technology proper to the underground Concrete Structure (국내 지하구조물에 적용 가능한 방수 기술 제안 연구)

  • Seon, Yun-Suk;Kim, Jin-Sung;Park, Jin-Sang;Kwon, Shi-Won;Oh, Sang-Keun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.409-412
    • /
    • 2006
  • The goal of waterproofing materials and construction method used for underground structure can be attained only when construction is done perfectly free of laitance, moisture and foreign substances on concrete surface. However, construction engineers agree that it is difficult to perfectly carry out such work in practice and realization of perfect waterproofing for underground structures is impossible in reality. Therefore, this study is to examine and explore waterproofing materials and construction method completely meeting environmental impacts that underground structures receive and thereby suggest waterproofing technology applicable to underground structures, in order to prevent problems caused by leakage for underground structures.

  • PDF

A Research for Weight Decision of Waterproofing Methods Selection Evaluation Item using the AHP (AHP기법을 이용한 방수공법 선정 평가항목의 가중치 결정에 관한 연구)

  • Choi, Sung-Min;Lim, Jong-Kwon;Oh, Sang-Keun;Seo, Chee-Ho
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2008.11a
    • /
    • pp.205-211
    • /
    • 2008
  • Recently, selects method of waterproofing where is suitable with method and material physical properties, construction technique, Productive technique and specifications and maintenance techniques evaluation for the same evaluation method is coming to be presented. Respects the application which select system is substantial objectively reflects a weight to evaluation item the research for is necessary. This research the evaluation which in order is effective and the decision-making to be possible about technically countermeasures for a quality security from waterproofing materials, method selection processes, clearly responsible dividing of construction and maintenance techniques. A sets weight of evaluation item for right select system, it stratify the causes which affect in priority based on AHP.

  • PDF

A Study on Changes of Physical Properties of Rooftop Exposed Waterproofing PVC Sheet based on Longterm Outdoor Exposure Testing with Bearings (North, South) (옥상 노출방수용 PVC 방수시트의 방위별(남, 북) 장기옥외폭로에 따른 물성 변화 연구)

  • An, Ki-Won;Moon, You-Seok;Kim, Chun-Hag;Song, Je-Young;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.11a
    • /
    • pp.147-148
    • /
    • 2015
  • Exposed type waterproofing PVC sheets installed on structure rooftops are subject to changes in physical properties after longterm exposure to sunlight. Particularly when consideration the rotational movement of sunlight over the day through the course of the sun rising from the east and setting in the west, in the case of flat roofs the amount of UV ray the the surface of the PVC waterproofing sheet receives may be even throughout, but in cases of slanted rooftops the sunlight exposure may be uneven across the surface. In this regard, this study examines the effect uneven sunlight exposure on the exposed type waterproofing PVC sheets installed on slanted rooftops.

  • PDF

Compound waterproofing method of green roof using copper barrier sheet and recycled tire melting liquid waterproofing material that reinforced treatments are valve and glass fiber mesh. (알루미늄 판막과 유리섬유를 합지한 구리방근시트와 폐타이어 용융액상 도막방수재를 이용한 옥상녹화 복합방수공법)

  • Kim, Young chan;Cho, Il Kyu;choi, sung min;Oh, Sang Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2008.11a
    • /
    • pp.173-178
    • /
    • 2008
  • This is green roof bottom system which composed by aluminum valve and glass fiber together as major reinforcement, so the cooper sheet can have root proof, and using recycled tire gel-type membrane waterproofing system which dost not contains VOCs. The copper sheet reduce the plants' root growing, so it helpes to maintain the waterproofing layer and stability of root proofing. Gel type membrane waterproofing system can do waterproofing, stress dispersion, and reducing leakage expansion. So those two materials can help each other to make green roof bottom layer would have the stability and durability.

  • PDF

A Study on Performance Test Method of Polyurea Waterproofing System Applied to the Concrete Water Tank (콘크리트 수조에 적용되는 폴리우레아 방수방식 공법의 내구성 향상을 위한 시험 평가 방법에 관한 연구)

  • DO, Kwang-Ku;Song, Je-Young;Kim, Byoungil;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.06a
    • /
    • pp.12-13
    • /
    • 2020
  • Construction projects and buildings are becoming taller and larger, and the size of water tanks of production facilities and high-rise buildings is also gradually increasing. Most large water tanks apply a waterproofing layer to the water tank type concrete structure. The application of polyurea coating materials, which are excellent in water resistance, chemical resistance, physical performance, rapid hardening, and workability is gradually increasing as waterproofing and anticorrosion layer for water tank. As a result, defects such as water leakage and damage to the waterproofing layer are continuously occurring, causing production disruption, setback to users. Therefore, it is required to review suitability through performance verification of the waterproofing and anticorrosion system.

  • PDF

Anti-Seismic Evaluation of Waterproofing Materials for Positive-Side wall and pile wall of Underground Concrete Structures (합벽구간 및 지하구조물 외벽에 사용되는 방수재료 내진 성능실험방법)

  • Oh, Kyu-hwan;Kim, Soo-Yeon;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.210-211
    • /
    • 2021
  • This study introduces and demonstrates the application of an experimental regime for anti-seismic performance evaluation of waterproofing materials to used for concrete pile walls. Concrete pile walls are subject to high degree of seismic load, and the occurring stress can affect the waterproofing integrity of the structure, but there is currently no existing methodology or standard for evaluating this property of waterproofing materials. To propose and conduct this evaluation, a new testing apparatus was designed and manufactured intended to be able to test an installed waterproofing material's seismic resistance performance.

  • PDF

A Study on Waterproofing and Anticorrosive Performance Evaluation of Polyurea Resin Waterproofing Membrane Coating of Velocity per Second Hardening (초속경화(初速硬化) 폴리우레아수지 도막방수재(途膜防水材)의 방수(防水)·방식(防蝕) 성능평가(性能評價)에 관한 연구(硏究))

  • Cho, Chan-Haeng;Kang, Hyo-Jin;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2003.11a
    • /
    • pp.91-95
    • /
    • 2003
  • There is a problem to be solved for improvement of durability and safety supervision. When you do the waterproofing and anticorrosive work of main concrete from the design stage, the material and method of construction need to be correctly applied to appropriate circumstance conditions. Epoxy have mostly been used for concrete water tank structure. Lately, lots of subjects on adaption of polyurea resin waterproofing and anticorrosive are under discussion. Then, we attempt to approach by evaluating and comparing every capabilities with another waterproofs in this study. Performance evaluation items include the adherence performance, the imprint of seal performance, temperature dependence performance, promotion weatherizing ability, inner chemical performance, drinking water eruptive performance. Through the experiment analysis, we found that the polyurea resin waterproofing membrane is dominantly superior to other waterproofs. According to this study, we suggest the polyurea resin waterproofing membrane as a new waterproofing material for concrete structure.

  • PDF