• Title/Summary/Keyword: Water storage

Search Result 3,787, Processing Time 0.034 seconds

Improvement of Microbiological Quality of Ganjang-gejang by Acetic Acid Washing and Addition of Chitosan (초산 세척과 키토산 첨가에 의한 간장게장의 미생물학적 품질 향상)

  • Lee, Seok-Gyu;Lee, Bo-Ram;Yuk, Hyun-Gyun
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.3
    • /
    • pp.296-302
    • /
    • 2019
  • Ganjang-gejang (soy sauce-marinated crab) is a ready-to-eat (RTE) seafood and is also one of the most popular traditional dishes in Korea. It is generally prepared by washing raw blue crabs and then preserving them in soy sauce. Since this process does not involve cooking or any treatment with heat, it is difficult to control the microbiological quality of the final product. Thus, the objectives of this study were to compare the efficacies of various sanitizers in eliminating microorganisms on raw blue crab during the washing step and to evaluate the effectiveness of chitosan on the inhibition of microbial growth in the ganjang-gejang during storage. The raw blue crabs were submerged in chlorinated water (50 mg/L), peracetic acid (40 mg/L), acetic acid (5%) and lactic acid (5%) for 10 min at $25^{\circ}C$, respectively. The blue crabs treated with 5% acetic acid were marinated with soy sauce containing 0.5 and 1% of soluble chitosan, followed by storing them at 4 and $12^{\circ}C$ for up to 30 days. Results show that 5% acetic acid reduced the microbial populations on the blue crabs by 1.5 log CFU/g, which was significantly higher than those of other treatments. Based on these results, 5% acetic acid was selected for the washing step. The microbial populations of all ganjang-gejang samples significantly increased to about 8.0 CFU/g at $12^{\circ}C$ for 7 days. At $4^{\circ}C$, the microbial populations of the products containing 1% chitosan increased by about 2.9 CFU/g for 20 days, which were significantly lower than those (4.2-4.5 log CFU/g) of the products without and with 0.5% chitosan. Thus, these results suggest that 5% acetic acid washing of raw blue crabs and the addition of 1% chitosan in ganjang-gejang could improve the microbiological quality of the final products under refrigerated condition.

Effects of Dietary Supplementation of Enzyme complex on Growth Performance, Carcass Characteristics and Meat storability in Broiler Chickens (사료 내 복합효소제의 첨가가 육계 생산성 및 도체특성 및 저장성에 미치는 영향)

  • Kim, Ki-Hyun;Jeong, Jin-Young;Song, Il-Hwan;Lee, Sung-Dae;Ji, Sang-Yun;Lee, Yoo-Kyong;Nam, Ki-Taeg
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.12
    • /
    • pp.740-748
    • /
    • 2018
  • This study was conducted to investigate the effects of dietary supplementation of enzyme complex (metalloprotease and xylanase) on growth performance, carcass characteristics and meat storability of broiler chickens. The experiment utilized a 2 (basal and low spec diets) ${\times}$ 3 (0, 0.5 or 1 g/kg of enzyme supplementation) factorial arrangement. A total of 360 male Ross broilers were randomly assigned into the following six groups: BD-T0 (basal diet + enzyme complex 0 g/kg), BD-T1 (basal diet + enzyme complex 0.5 g/kg), BD-T2 (basal diet + enzyme complex 1 g/kg), LD-T0 (low spec diet + enzyme complex 0 g/kg), LD-T1 (low spec diet + enzyme complex 0.5 g/kg), LD-T2 (low spec diet + enzyme complex 1 g/kg). Feed and water were provided ad libitum for 42 days, during which time feed intake and body weight were measured at one-week intervals. After the feeding trial, chickens were slaughtered by exsanguination and samples were collected. Feed intake was lower in the enzyme supplemented groups than the non-supplemented groups (p<0.05), as were body weight and gain (p<0.05). Thus, the feed conversion ratio improved in the enzyme supplemented groups relative to the non-supplemented groups (p<0.05). The carcass rate and production index were also significantly improved by supplementation with enzyme complex (p<0.05). Finally, the thiobarbituric acid reactive substances (TBARS) values were lower in the enzyme supplementation groups after 6 storage days (p<0.05). In conclusion, dietary supplementation with enzyme complex including metalloprotease and xylanase improved growth performance, carcass characteristics, and storability of broiler chicken meat.

Establishment of A WebGIS-based Information System for Continuous Observation during Ocean Research Vessel Operation (WebGIS 기반 해양 연구선 상시관측 정보 체계 구축)

  • HAN, Hyeon-Gyeong;LEE, Cholyoung;KIM, Tae-Hoon;HAN, Jae-Rim;CHOI, Hyun-Woo
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.24 no.1
    • /
    • pp.40-53
    • /
    • 2021
  • Research vessels(R/Vs) used for ocean research move to the planned research area and perform ocean observations suitable for the research purpose. The five research vessels of the Korea Institute of Ocean Science & Technology(KIOST) are equipped with global positioning system(GPS), water depth, weather, sea surface layer temperature and salinity measurement equipment that can be observed at all times during cruise. An information platform is required to systematically manage and utilize the data produced through such continuous observation equipment. Therefore, the data flow was defined through a series of business analysis ranging from the research vessel operation plan to observation during the operation of the research vessel, data collection, data processing, data storage, display and service. After creating a functional design for each stage of the business process, KIOST Underway Meteorological & Oceanographic Information System(KUMOS), a Web-Geographic information system (Web-GIS) based information platform, was built. Since the data produced during the cruise of the R/Vs have characteristics of temporal and spatial variability, a quality management system was developed that considered these variabilities. For the systematic management and service of data, the KUMOS integrated Database(DB) was established, and functions such as R/V tracking, data display, search and provision were implemented. The dataset provided by KUMOS consists of cruise report, raw data, Quality Control(QC) flagged data, filtered data, cruise track line data, and data report for each cruise of the R/V. The business processing procedure and system of KUMOS for each function developed through this study are expected to serve as a benchmark for domestic ocean-related institutions and universities that have research vessels capable of continuous observations during cruise.

Spectral Induced Polarization Characteristics of Rocks in Gwanin Vanadiferous Titanomagnetite (VTM) Deposit (관인 함바나듐 티탄철광상 암석의 광대역 유도분극 특성)

  • Shin, Seungwook
    • Geophysics and Geophysical Exploration
    • /
    • v.24 no.4
    • /
    • pp.194-201
    • /
    • 2021
  • Induced polarization (IP) effect is known to be caused by electrochemical phenomena at interface between minerals and pore water. Spectral induced polarization (SIP) method is an electrical survey to localize subsurface IP anomalies while injecting alternating currents of multiple frequencies into the ground. This method was effectively applied to mineral exploration of various ore deposits. Titanomagnetite ores were being produced by a mining company located in Gonamsan area, Gwanin-myeon, Pocheon-si, Gyeonggi-do, South Korea. Because the ores contain more than 0.4 w% vanadium, the ore deposit is called as Gwanin vanadiferous titanomagnetite (VTM) deposit. The vanadium is the most important of materials in production of vanadium redox flow batteries, which can be appropriately used for large-scale energy storage system. Systematic mineral exploration was conducted to identify presence of hidden VTM orebodies and estimate their potential resources. In geophysical exploration, laboratory geophysical measurement of rock samples is helpful to generate reliable property models from field survey data. Therefore, we performed laboratory SIP data of the rocks from the Gwanin VTM deposit to understand SIP characteristics between ores and host rocks and then demonstrate the applicability of this method for the mineral exploration. Both phase and resistivity spectra of the ores sampled from underground outcrop and drilling cores were different of those of the host rocks consisting of monzodiorite and quartz monzodiorite. Because the phase and resistivity at frequencies below 100 Hz are mainly dependent on the SIP characteristics of the rocks, we calculated mean values of the ores and the host rocks. The average phase values at 0.1 Hz were ores: -369 mrad and host rocks: -39 mrad. The average resistivity values at 0.1 Hz were ores: 16 Ωm and host rocks: 2,623 Ωm. Because the SIP characteristics of the ores were different of those of the host rocks, we considered that the SIP survey is effective for the mineral exploration in vanadiferous titanomagnetite deposits and the SIP characteristics are useful for interpreting field survey data.

Trade-off Analysis Between National Ecosystem Services Due to Long-term Land Cover Changes (장기간 토지피복 변화에 따른 국내 생태계서비스 간 상쇄효과(Trade-off) 분석)

  • Yoon-Sun Park;Young-Keun Song
    • Korean Journal of Environment and Ecology
    • /
    • v.38 no.2
    • /
    • pp.204-216
    • /
    • 2024
  • Understanding the trade-off effect in ecosystem services and measuring the interrelationships between services are crucial for managing limited environmental resources. Accordingly, in this study, we identified the dominant trends and increases and decreases in ecosystem services derived from changes in land cover over about 30 years and tracked changes in the relationships between ecosystem services that occurred over time. Through it, we determined the relationship between land cover changes and ecosystem service changes, as well as the distinct characteristics of service changes in different areas. The research primarily utilized the InVEST model, an ecosystem service assessment model. After standardizing the evaluation results between 0 and 1, it went through principal component analysis, a dimensionality reduction technique, to observe the time-series changes and understand the relationships between the services. According to the research results, the area of urbanized regions dramatically increased between 1989 and 2019, while forests showed a significant increase between 2009 and 2019. Between 1989 and 2019, the national ecosystem service supply witnessed a 13.9% decrease in water supply, a 10.5% decrease in nitrogen retention, a 2.6% increase in phosphorus retention, a 0.9% decrease in carbon storage, a 1.2% increase in air purification, and a 3.4% decrease in habitat quality. Over the past 30 years, South Korea experienced an increase in urbanized areas, a decrease in agricultural land, and an increase in forests, resulting in a trade-off effect between phosphorus retention and habitat quality. This study concluded that South Korea's environment management policies contribute to improving ecosystem quality, which has declined due to urbanization, and maximizing ecosystem services. These findings can help policymakers establish and implement forestry policies focusing on sustainable environmental conservation and ecosystem service provision.

AHP Analysis Research to Improve the Busan Port Ship Supplies Industry (부산항 선용품산업의 개선을 위한 AHP 분석 연구)

  • Ei Mon Khaing;Cho, Ye-hee;Ha, Myoung-shin
    • Journal of Korea Port Economic Association
    • /
    • v.40 no.2
    • /
    • pp.21-38
    • /
    • 2024
  • The current situation of ports and related industries is transitioning from quantitative growth in increased cargo volume and expansion of port facilities to qualitative growth in the role of ports through the creation of high value-added. Ports are now recognized as playing an important role in economic growth and development by generating high value-added, not just by increasing the amount of cargo and expanding port facilities. This study evaluated the importance of factors affecting the improvement of the Busan Port's marine equipment industry by using the Analytic Hierarchy Process(AHP) to derive the priority of improvement measures by factor and evaluate the importance of factors affecting the marine equipment industry. The factors that should be considered when selecting improvement measures for the marine equipment industry were selected as four factors: strengthening price competitiveness, increasing government and local government interest, strengthening promotion, and establishing a global network. The main sub-factors were composed of eight detailed evaluation factors by selecting two factors for each layer. The analysis was designed by dividing the factor hierarchy for selecting improvement measures for the marine equipment industry into three levels and creating survey questions for pairwise comparison. The priority of the analysis results using AHP showed that the factor with the highest priority was strengthening price competitiveness, followed by increasing government and local government interest, establishing a global network, and strengthening promotion. According to the analysis results for the second-level sub-factors, among the factors for strengthening price competitiveness, low distribution costs and storage costs were considered most important, followed by avoiding excessive competition among marine equipment companies. Among the factors for increasing government and local government interest, improving customs procedures and tariff refund procedures were considered most important, followed by strengthening incentives from the government and Busan City. Among the factors for establishing a global network, promoting large-scale marine equipment companies was considered most important, followed by actively participating in international marine equipment-related associations. Among the factors for strengthening promotion, active use of the Internet was considered most important, followed by holding domestic and international exhibitions. Based on this study, we hope to help activate Busan Port's market by enhancing its competitiveness through revitalizing its marine equipment industry, generating water traffic, and creating new value-added.

Consideration on Shielding Effect Based on Apron Wearing During Low-dose I-131 Administration (저용량 I-131 투여시 Apron 착용여부에 따른 차폐효과에 대한 고찰)

  • Kim, Ilsu;Kim, Hosin;Ryu, Hyeonggi;Kang, Yeongjik;Park, Suyoung;Kim, Seungchan;Lee, Guiwon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.32-36
    • /
    • 2016
  • Purpose In nuclear medicine examination, $^{131}I$ is widely used in nuclear medicine examination such as diagnosis, treatment, and others of thyroid cancer and other diseases. $^{131}I$ conducts examination and treatment through emission of ${\gamma}$ ray and ${\beta}^-$ ray. Since $^{131}I$ (364 keV) contains more energy compared to $^{99m}Tc$ (140 keV) although it displays high integrated rate and enables quick discharge through kidney, the objective of this study lies in comparing the difference in exposure dose of $^{131}I$ before and after wearing apron when handling $^{131}I$ with focus on 3 elements of external exposure protection that are distance, time, and shield in order to reduce the exposure to technicians in comparison with $^{99m}Tc$ during the handling and administration process. When wearing apron (in general, Pb 0.5 mm), $^{99m}Tc$ presents shield of over 90% but shielding effect of $^{131}I$ is relatively low as it is of high energy and there may be even more exposure due to influence of scattered ray (secondary) and bremsstrahlung in case of high dose. However, there is no special report or guideline for low dose (74 MBq) high energy thus quantitative analysis on exposure dose of technicians will be conducted based on apron wearing during the handling of $^{131}I$. Materials and Methods With patients who visited Department of Nuclear Medicine of our hospital for low dose $^{131}I$ administration for thyroid cancer and diagnosis for 7 months from Jun 2014 to Dec 2014 as its subject, total 6 pieces of TLD was attached to interior and exterior of apron placed on thyroid, chest, and testicle from preparation to administration. Then, radiation exposure dose from $^{131}I$ examination to administration was measured. Total procedure time was set as within 5 min per person including 3 min of explanation, 1 min of distribution, and 1 min of administration. In regards to TLD location selection, chest at which exposure dose is generally measured and thyroid and testicle with high sensitivity were selected. For preparation, 74 MBq of $^{131}I$ shall be distributed with the use of $2m{\ell}$ syringe and then it shall be distributed after making it into dose of $2m{\ell}$ though dilution with normal saline. When distributing $^{131}I$ and administering it to the patient, $100m{\ell}$ of water shall be put into a cup, distributed $^{131}I$ shall be diluted, and then oral administration to patients shall be conducted with the distance of 1m from the patient. The process of withdrawing $2m{\ell}$ syringe and cup used for oral administration was conducted while wearing apron and TLD. Apron and TLD were stored at storage room without influence of radiation exposure and the exposure dose was measured with request to Seoul Radiology Services. Results With the result of monthly accumulated exposure dose of TLD worn inside and outside of apron placed on thyroid, chest, and testicle during low dose $^{131}I$ examination during the research period divided by number of people, statistics processing was conducted with Wilcoxon Signed Rank Test using SPSS Version. 12.0K. As a result, it was revealed that there was no significant difference since all of thyroid (p = 0.345), chest (p = 0.686), and testicle (p = 0.715) were presented to be p > 0.05. Also, when converting the change in total exposure dose during research period into percentage, it was revealed to be -23.5%, -8.3%, and 19.0% for thyroid, chest, and testicle respectively. Conclusion As a result of conducting Wilcoxon Signed Rank Test, it was revealed that there is no statistically significant difference (p > 0.05). Also, in case of calculating shielding rate with accumulate exposure dose during 7 months, it was revealed that there is irregular change in exposure dose for inside and outside of apron. Although the degree of change seems to be high when it is expressed in percentage, it cannot be considered a big change since the unit of accumulated exposure dose is in decimal points. Therefore, regardless of wearing apron during high energy low dose $^{131}I$ administration, placing certain distance and terminating the administration as soon as possible would be of great assistance in reducing the exposure dose. Although this study restricted $^{131}I$ administration time to be within 5 min per person and distance for oral administration to be 1m, there was a shortcoming to acquire accurate result as there was insufficient number of N for statistics and it could be processed only through non-parametric method. Also, exposure dose per person during lose dose $^{131}I$ administration was measured with accumulated exposure dose using TLD rather than through direct-reading exposure dose thus more accurate result could be acquired when measurement is conducted using electronic dosimeter and pocket dosimeter.

  • PDF