• Title/Summary/Keyword: Water sampling

Search Result 1,260, Processing Time 0.028 seconds

The Effects of Sample Disturbance on Undrained Properties of Yangsan Clay (양산점토의 비배수 특성에 대한 시료교란의 효과)

  • 김길수;임형덕;이우진
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.03b
    • /
    • pp.639-646
    • /
    • 2000
  • It is important to estimate the mechanical properties of clay since it is directly related to the design and the construction of geotechnical structures. Site exploration, which is composed of boring, sampling, in-situ, or laboratory tests, is preformed to estimate the mechanical properties. However, mechanical properties of clay measured from laboratory test may be different from in-situ properties due to disturbances occurred during sampling, transportation, storage, and trimming. In this study, the degree of disturbance according to sampling method was estimated with the test results of CK/sub o/U triaxial compression test on Yangsan clay. The soil samples were obtained by three types of sampling method, j.e., 76mm-tube sampler, 76mm-piston sampler, and block sampler. In order to evaluate the quality of samples, volumetric strain, undrained shear strength, secant Young's modulus, and pore pressure coefficient at peak measured from each sample were compared with one another. From the test results, it was observed that mechanical properties of the block and piston samples were more reliable than those of tube samples. But it was observed that the water content of piston was similar to that of tube samples at given depths while the water content of block samples was 14.3∼15.8% smaller than that of piston and tube samples. In addition to the evaluation of the quality of samples, relationship between c/sub u// σ/sub vc/'and OCR was established from the results of the CK/sub o/U triaxial compression tests, which were carried out using SHANSEP method. And also undrained shear strength was analyzed using the in-situ test data such as Cone Penetration Test(CPT), Dilatometer Test(DMT), and Field Vane Test(FVT) and was compared with that evaluated from CK/sub o/U triaxial compression test.

  • PDF

Water Quality Characteristics in Keum River Watershed (금강 수계의 수질 특성)

  • An, Kwang-Guk;Yang, Woo-Mi
    • Korean Journal of Ecology and Environment
    • /
    • v.40 no.1
    • /
    • pp.110-120
    • /
    • 2007
  • The objective of this study was to analyze temporal trends of water chemistry and spatial heterogeneity for 13 sampling sites of the Keum River watershed using water quality dataset (obtained from the Ministry of Environment, Korea) during $2001{\sim}2005$. The water quality, based on eight physical and chemical parameters, varied largely depending on the years, seasons, and sampling sites. Seasonal and annual means of conductivity, used as a key indicator for a ionic dilution declined during the monsoon season, and nutrients (TN and TP), based on overall mean of all sites, showed marked declines during the monsoon, compared to those of the premonsoon. In the mean time, BOD and COD had no significant relations with a precipitation, in spite of some differences in the sampling sites. In contrast, major input of SS occurred during the period of summer monsoon. and the variation of TN was similar to that of TP. Spatial trend analyses of all parameters, except for DO and temperature, showed that Site 9 acted as a point source, and thus, water quality at the locations of $S9{\sim}S13$ declined abruptedly over 2 fold, compared to locations of $S1{\sim}S8$. Based on the overall dataset, efficient water quality management in the point source tributary streams is required for better water quality of the main Keum River.

Sampling and Analysis of Soil Pore Water for Predicting the Diffusion and Behavior of Soil Pollutant Using Soil Lysimeter (토양라이시미터를 이용한 토양오염확산.거동 예측을 위한 토양공극수 채취와 분석)

  • Ko, Il-Won;Lee, Se-Yong;Kim, Kyoung-Woong;Lee, Jin-Soo
    • Economic and Environmental Geology
    • /
    • v.40 no.5
    • /
    • pp.551-561
    • /
    • 2007
  • This case study is about the sampling and interpretation of soil pore water in order to understand and to predict the diffusion and behavior of soil pollution. For the measurement of polycyclic aromatic hydrocarbons(PAHs) in two representative hydrocarbon-contaminated sites, the extraction system of the soil pore water was set up with respect to soil depths and the behavior of contaminants was interpreted. The soil solution extraction system consisted of peristaltic pump, and extraction and sampling compartment, and can measure simultaneously the soil water pressure. The concentration of PAHs with respect to extraction pressure and time decreased due to dilution through soil pore water. Particularly, the concentration of PAHs was more reduced under the unsaturated oxic condition than saturated anoxic condition. Therefore, the soil solution extraction with respect to soil water pressure can interpret the extent of equilibrium between porewater and soil surface.

Characteristics of Water Quality in Hyeongsan River Watershed (형산강 수계의 수질 특성)

  • Kim, Yu-Pyo;An, Kwang-Guk
    • Korean Journal of Ecology and Environment
    • /
    • v.43 no.1
    • /
    • pp.150-160
    • /
    • 2010
  • The objective of this study was to analyze long-term temporal trends of water chemistry and spatial heterogeneity for 7 sampling sites of the Hyeongsan River watershed using water quality dataset during 1999 to 2008 (obtained from the Ministry of Environment, Korea). The water quality, based on eight physical and chemical parameters, varied largely depending on the years, seasons and sampling sites. Seasonal and annual means of conductivity, used as a key indicator for a ionic dilution declined during the monsoon season and TN, based on overall mean of all sites, showed marked declines during the monsoon, compared to those of the premonsoon. In the mean time, BOD and COD had no significant relations with a precipitation, in spite of some differences in the sampling sites. In contrast, major input of SS occurred during the period of summer monsoon season. Spatial trend analyses of all parameters, except for DO and temperatures, showed that gyeongju city acted as a point source, and thus, water quality at the location of Site 4 declined abruptly, compared to locations of Site 1~2. Based on overall dataset, efficient water quality management in the point source tributary streams is required for better water quality of the main Hyeongsan River.

The Statistical Model for Predicting Flood Frequency

  • Noh, Jae-Sik;Lee, Kil-Choon
    • Korean Journal of Hydrosciences
    • /
    • v.4
    • /
    • pp.51-63
    • /
    • 1993
  • This study is to verify the applicability of statistical models in predicting flood frequency at the stage gaging stations of which the flow is under natural condition in the Han River basin. The results of the study show that the statistical flood frequency models were proven to be fairly reasonable to apply in practice, and also were compared with sampling variance to calibrate the statistical efficiency of the estimators of the T year floods Q(T) by two different flood frequency models. As a result, it was showed that for return periods greater than about T = 10 years the annual exceedance series estimators of Q(T) has smaller sampling variance than the annual maximum series estimators. It was showed that for the range of return periods the partial duration series estimators of !(T) has smaller sampling variance than the annual maximum series estimate only if the POT model contains at least 2N(N : record length) items or more in order to estimate Q(T) more efficiently than the ANNMAX model.

  • PDF

A Background Subtraction Algorithm for Fence Monitoring Surveillance Systems (담장 감시 시스템을 위한 배경 제거 알고리즘)

  • Lee, Bok Ju;Chu, Yeon Ho;Choi, Young Kyu
    • Journal of the Semiconductor & Display Technology
    • /
    • v.14 no.3
    • /
    • pp.37-43
    • /
    • 2015
  • In this paper, a new background subtraction algorithm for video based fence monitoring surveillance systems is proposed. We adopt the sampling based background subtraction technique and focus on the two main issues: handling highly dynamic environment and handling the flickering nature of pulse based IR (infrared) lamp. Natural scenes from fence monitoring system are usually composed of several dynamic entities such as swaying trees, moving water, waves and rain. To deal with such dynamic backgrounds, we utilize the confidence factor for each background value of the input image. For the flickering IR lamp, the original sampling based technique is extended to handle double background models. Experimental results revealed that our method works well in real fence monitoring surveillance systems.

Comparative Study on the Sampling Methods of Benthic Macroinvertebrates in the Fine Sediments of Freshwater (담수의 세립질 퇴적물 내 저서성 대형무척추동물 채집방법 비교 연구)

  • Kim, PilJae;Kim, Ah Reum;Kwon, Yongju;Min, Jeong Ki;Huh, In Ae;Kong, Dongsoo
    • Journal of Korean Society on Water Environment
    • /
    • v.34 no.1
    • /
    • pp.84-95
    • /
    • 2018
  • The community structure of benthic macroinvertebrates in the fine sediments of freshwater was analyzed according to various sampling tools and methods. The sediment core with the inner diameter of 7.5 cm was more effective in cost and labor in comparison to that of ${\Phi}5cm$ or ${\Phi}10cm$. The number of species increased with the increase in sample size (replicates). When it was collected five times with the ${\Phi}7.5cm$ sediment core, Shannon-Weaver's diversity and McNaughton's dominance of the sample reached about the 80 % level of the community estimates. Most species appeared in the sediment layer of 0-4 cm, and there were no newly recruited species below the depth of 4 cm. Individual abundance of benthic macroinvertebrates decreased exponentially along with the increase in sediment depth. Compared with the individual abundance of the 0-15 cm sediment layer, the abundance was 60 % in the 0-2 cm layer, 25 % in the 2-4 cm layer, 10 % in the 4-6 cm layer and 95 % in the 0-6 cm layer. Compared with organisms collected with the sieve of 0.2 mm pore, the number of species and the individual abundance sifted through the sieve with pore of 1 mm were 36 % and 88 %, and those with pore of 0.5 mm were 5 % and 55 %, respectively.

Characteristics of Water and Environmental Qualities of Seho Watershed in Suwon City (수원시 서호천의 수질현황 및 환경질 특성)

  • Chi, Hong-Jin;Lee, Sang-Eun;Choi, Young-Keun;Lee, Jae-Dong
    • Journal of Environmental Science International
    • /
    • v.22 no.6
    • /
    • pp.733-744
    • /
    • 2013
  • This study was to investigate characteristics of Seoho watershed in Suwon city. $BOD_5$ and SS were selected due to the one of the important factors of the water qualities. Monitoring was conducted monthly for four years during the non-rainfall time. Also, we have been monitored $BOD_5$, $COD_{Mn}$, SS, TN and TP with two times sampling after the rainfalls. The highest concentrations of $BOD_5$ and SS were observed in downstream compare with upstream and midstream during the non-rainfall time. No change was observed in $BOD_5$ and $COD_{Mn}$ during the non-rainfall time and after the rainfalls. The monitoring result indicated that the concentration of SS was the highest in downstream after the rainfalls. We have collected the samples two times after the rainfalls. The rainfall intensity in first sampling was two times higher than second sampling. TN and TP concentrations were increased with increasing the rainfall intensity at all stream. The ESB (Ecological Score of Benthic macroinverterbrate community) index was used to evaluate the statement of stream. ESB results were identified that the upstream is protected waters and the down and midstream is reformed waters. EBS analysis results indicated that the Seoho watershed was ${\beta}$-mesosaprobic at all stream.

Criteria for calculation of CSO volume and frequency using rainfall-runoff model (우수유출 모형을 이용한 합류식하수관로시스템의 월류량, 월류빈도 산정 기준 결정 연구)

  • Lee, Gunyoung;Na, Yongun;Ryu, Jaena;Oh, Jeill
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.3
    • /
    • pp.313-324
    • /
    • 2013
  • It is widely known that untreated Combined Sewer Overflows (CSOs) that directly discharged from receiving water have a negative impact. Recent concerns on the CSO problem have produced several large scale constructions of treatment facilities, but the facilities are normally designed under empirical design criteria. In this study, several criteria for defining CSOs (e.g. determination of effective rainfall, sampling time, minimum duration of data used for rainfall-runoff simulation and so on) were investigated. Then this study suggested a standard methodology for the CSO calculation and support formalized standard on the design criteria for CSO facilities. Criteria decided for an effective rainfall was over 0.5 mm of total rainfall depth and at least 4 hours should be exist between two different events. An Antecedent dry weather period prior to storm event to satisfy the effective rainfall criteria was over 3 days. Sampling time for the rainfall-runoff model simulation was suggested as 1 hour. A duration of long-term simulation CSO overflow and frequency calculation should be at least recent 10 year data. A Management plan for the CSOs should be established under a phase-in of the plan. That should reflect site-specific conditions of different catchments, and formalized criteria for defining CSOs should be used to examine the management plans.

Characteristics of Pollutant Loading from Paddy Field Area with Groundwater Irrigation (지하수 관개지역 논에서의 배출부하 특성)

  • 윤춘경;김병희;전지홍;황하선
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.44 no.5
    • /
    • pp.116-126
    • /
    • 2002
  • Discharge pattern and water quality were investigated in the drainage water from about 10 ha of groundwater-irrigated paddy field in the growing season of 2001. Total discharge quantity was about 1,117.2 mm in which about 75% was caused by management drainage due to cultural practice of paddy rice farming and the rest by rainfall runoff where total rainfall was about 515 mm. Dry-day sampling data showed wide variations in constituent concentrations with average of 26.14 mg/L, 0.37 mg/L, 3.54 mg/L at the inlet, and 43.60 mg/L, 0.34 mg/L, 3.58 mg/L at the outlet for CO $D_{cr}$ , T-P, and T-N, respectively. Wet-day sampling data demonstrated that generally CO $D_{cr}$ followed the discharge pattern and T-P was in opposite to the discharge pattern, but T-N did not show apparent pattern to the discharge. Discharge and load are in strong relationship. And based on regression equation, pollutant loads from groundwater irrigation area are estimated to be 288.34, 1.17, and 5.45 kg/ha for CO $D_{cr}$ , T-P, and T-N, respectively, which was relatively lower than the literature value from surface water irrigation area which implies that groundwater irrigation area might use less irrigation water and result in less drainage water, Therefore, total pollutant load from paddies irrigation with groundwater could be significantly lower than that with surface water. This study shows that agricultural drainage water management needs a good care of drainage outlet as well as rainfall runoff. This study was based on limited monitoring data of one year, and further monitoring and successive analysis are recommended for more generalized conclusion.