• Title/Summary/Keyword: Water current energy

Search Result 682, Processing Time 0.026 seconds

Numerical Simulation of Normal Logging Measurements in the Proximity of Earth Surface (지표 부근에서의 노멀전기검층 수치 모델링)

  • Nam, Myung-Jin;Hwang, Se-Ho
    • Economic and Environmental Geology
    • /
    • v.43 no.3
    • /
    • pp.259-267
    • /
    • 2010
  • Resistivity logging instruments were designed to measure electrical resistivity of formation, which can be directly interpreted to provide water-saturation profile. Short and long normal logging measurements are made under groundwater level. In some investigation sites, groundwater level reaches to a depth of a few meters. It has come to attention that the proximity of groundwater level might distort short and long normal logging readings, when the measurements are made near groundwater level, owing to the proximity of an insulating air. This study investigates the effects of the proximity of groundwater level (and also the proximity of earth surface) on the normal by simulating normal logging measurements near groundwater level. In the simulation, we consider all the details of real logging situation, i.e., the presence of wellbore, the tool mandrel with current and potential electrodes, and currentreturn and reference-potential electrodes. We also model the air to include the earth’'s surface in the simulation rather than the customary choice of imposing a boundary condition. To obtain apparent resistivity, we compute the voltage, i.e., potential difference between monitoring and reference electrodes. For the simulation, we use a twodimensional, goal-oriented and high-order self-adaptive hp finite element refinement strategy (h denotes the element size and p the polynomial order of approximation within each element) to obtain accurate simulation results. Numerical results indicate that distortion on the normal logging is greater when the reference potential electrode is closer to the borehole and distortions on long normal logging are larger than those on short normal logging.

Characteristics of DOC Release from Sediment in Eutrophic Lake (부영양호 퇴적층으로부터 용존유기물의 용출특성)

  • Park, Je-Chul
    • Korean Journal of Ecology and Environment
    • /
    • v.36 no.3 s.104
    • /
    • pp.304-310
    • /
    • 2003
  • This study was conducted to estimate the internal dissolved organic carbon (DOC) loading from sediment in eutrophic shallow Lake Kasumigaura. Contents of water and organic carbon were about 80% and 6.3% with depth in the sediment, respectively. The highest DOC concentration in porewater (104 mg C/l) was observed in September suggesting that the porewater could play an important role as an internal loading of DOC. Results of DOC release experiments showed that the labile-DOC (L-DOC) release was not detected in the oxic condition, while refractory-DOC(R-DOC) release was detected. The L-DOC and R-DOC release rates in the anoxic codition ranged from 14.5${\sim}$ 48.6, 14.4 ${\sim}$27.3 mgC $m^{-2}$ $d^{-2}$, respectively. The current study showed that L-DOC released in the oxic condition was rapidly utilized by aerobic bacteria, in contrast, L-DOC and R-DOC released in anoxic codition were slowly utilized by anaerobic bacteria. These results suggested that L-DOC and R-DOC were closely related to sediment release and most of the R-DOC released could be an important source of DOC in eutrophic lakes during summer. Therefore, R-DOC pool should be added as one of the important energy source for microbial-based aquatic food webs in eutrophic lakes.

Pink Pigmented Facultative Methylotrophic Bacteria(PPFMs): Introduction to Current Concepts (분홍색 색소를 형성하는 methylotrophic acteria(PPFMs): 최근 경향소개)

  • Munusamy, Madhaiyan;Sa, Tongmin;Kim, Jai-Joung
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.37 no.4
    • /
    • pp.266-287
    • /
    • 2004
  • The non infecting, plant associated bacteria have attracted increased attention for stimulating plant growth and as environmental friendly plant protecting agents. Pink-pigmented facultatively methylotrophic bacteria (PPFMs), classified as Methylobacterium spp., are persistent colonizers of plant leaf surfaces. As the leaves of most or all plants harbor PPFMs that utilize leaf methanol as their sole source of carbon and energy, which is a specific attribute of the genus Methylobacterium. Although they are not well known, these bacteria are co-evolved, interacting partners in plant metabolism. This claim is supported, for example, by the following observations: (1) PPFMs are seed-transmitted, (2) PPFMs are frequently found in putatively axenic cell cultures, (3) Low numbers of seed-borne PPFMs correlate with low germinability, (4) Plants with reduced numbers of PPFM show elevated shoot/root ratios, (5) Foliar application of PPFMs to soybean during pod fill enhances seed set and yield, (6) Liverwort tissue in culture requires PPFM-produced vitamin B12 for growth, (7) treated plants to suppress or decrease disease incidence of sheath blight caused by Rhizoctonia solani in rice, and (8) the PPFM inoculation induced number of stomata, chlorophyll concentration and malic acid content, they led to increased photosynthetic activity. Methylobacterium spp. are bacterial symbionts of plants, shown previously to participate in plant metabolism by consuming plant waste products and producing metabolites useful to the plant. There are reports that inform about the beneficial interactions between this group of bacteria and plants. Screening of such kind of bacteria having immense plant growth promoting activities like nitrogen fixation, phytohormone production, alleviating water stress to the plants can be successfully isolated and characterized and integration of such kind of organism in crop production will lead to increased productivity.

Analysis of the Status of Mine and Methods of Mine Geospatial Information Construction Technology for Systematic Mine Management (체계적인 광산관리를 위한 광산현황 및 광산공간정보 구축 기술 분석)

  • Park, Joon-Kyu;Lee, Keun-Wang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.9
    • /
    • pp.355-361
    • /
    • 2018
  • Mining is important as a national key industry that supplies energy and raw materials that are the basis for industrial development. On the other hand, mine development is necessarily accompanied by mineralization, for example, ground subsidence, heavy metal pollution, and water pollution. The mine hazard has a large range of damage, and it takes much time and cost to recover. In addition, there is a need for systematic mining management in order to prevent damages from occurring continuously. In this study, the present status of domestic mining industry and geospatial information construction technology for mining management were investigated. 95% of the mines surveyed were nonmetallic, and limestone mines accounted for 67%, and the constructed mine spatial information is not constructed with 3D geospatial information due to 2D current status, section, and geological map. Considering the results of the survey and analysis of 3D laser scanner and characteristics of Korean mine, handheld scanner is considered to be the most suitable method for constructing mine geospatial information. In addition, the data acquired through the 3D laser scanner can effectively visualize the object, and it can contribute to the systematic management of mining because it can be used for various purposes such as generation of drawings and calculation of volume.

Position-Dependent Cathode Degradation of Large Scale Membrane Electrode Assembly for Direct Methanol Fuel Cell (직접 메탄올 연료전지용 대면적 막-전극 접합체 공기극의 위치별 열화 현상)

  • Kim, Soo-Kil;Lee, Eun-Sook;Kim, Yi-Young;Kim, Jang-Mi;Joh, Han-Ik;Ha, Heung-Yong
    • Journal of the Korean Electrochemical Society
    • /
    • v.12 no.2
    • /
    • pp.148-154
    • /
    • 2009
  • With respect to the durability of large scale ($150cm^2$) membrane electrode assembly (MEA) of direct methanol fuel cell (DMFC), degradation phenomena at cathode is monitored and analyzed according to the position on the cathode surface. After constant current mode operation of large scale MEA for 500 hr, the MEA is divided into three parts along the cathode channel; (close to) inlet, middle, and (close to) outlet. The performance of each MEA is tested and it is revealed that the MEA from the cathode outlet of large MEA shows the worst performance. This is due to the catalyst degradation and GDL delamination caused by flooding at cathode outlet of large MEA during the 500 hr operation. Particularly on the catalyst degradation, the loss of electrochemically active surface area (ECSA) of catalyst gets worse along the cathode channel from inlet to outlet, of which the reason is believed to be loss of catalysts by dissolution and migration rather than their agglomeration. The extent of loss in the performance and catalyst degradation has strong relation to the cathode flooding and it is required to develop proper water management techniques and separator channel design to control the flooding.

A Study on the Evacuation Characteristics Junction Indication Method of Disaster Information Map (재해정보지도의 교차경로 표시방법에 따른 피난특성에 관한 연구)

  • Sun, Ji-Eun;Hong, Won-Hwa
    • Fire Science and Engineering
    • /
    • v.32 no.5
    • /
    • pp.46-51
    • /
    • 2018
  • The purpose of this study was to assess the evacuation route in a disaster information map to evacuate people to a shelter quickly and precisely during a disaster situation. For this purpose, this study examined the current status of domestic and international disaster information maps and related laws and conducted experiments to derive effective types of intersecting routes. The problems of the disaster information map were obtained through the first preliminary experiment and a survey. Based on these problems, experiments for each type were conducted to provide effective indication information for a disaster information map. To investigate the gait characteristics according to the number of crossing paths, the reduction rate in the crossing path was derived for each type by comparing the previous speed and passing speed. This will enable suggestions to judge the route quickly and accurately when determining the intersecting route in the search for an evacuation route. In conclusion, the experiment of this paper aims to make rapid and accurate evacuations using the disaster information map in response to disasters, and provide guidelines to citizens to contribute to a reduction of casualties.

Treatment of Liquid Waste Containing Highly Concentrated Ethylenediaminetetraaceticacid by Using Underwater Electrical Discharge (수중 전기방전을 이용한 에틸렌디아민테트라아세트산 폐액의 처리)

  • Jo, Jin-Oh;Mok, Young-Sun;Kang, Duk-Won
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.5
    • /
    • pp.564-570
    • /
    • 2007
  • This study investigated the treatment of liquid waste containing highly concentrated iron(III)-ethylenediaminetetraaceticacid (Fe(III)-EDTA) of 70,000 mg/L by an underwater electrical discharge process using low voltage and high current. When AC voltage is applied to the discharging electrode with the other electrode grounded, the temperature of the liquid waste around the discharging electrode rapidly increases, and at the same time, hydrogen and oxygen gases are formed at the electrode as a result of electrochemical reactions. Ultimately, gases formed by vaporization of water and electrochemical reactions cover the electrode. Since the liquid waste is electrically conductive, it elongates the ground electrode up to the border of the gas layer, where electrical discharge occurs. Without hydrogen peroxide, electrical discharge was able to remove about 50% of Fe(III)-EDTA. As the concentration of hydrogen peroxide added increased, the removal efficiency of Fe(III)-EDTA increased. When the molar ratio of hydrogen peroxide to the initial Fe(III)-EDTA was higher than 24.7, more than 80 g of Fe(III)-EDTA was removed with an energy of 1 kWh. A comparison between tungsten and steel electrodes showed that electrode material did not affect the Fe(III)-EDTA removal. In the present underwater electrical discharge process, the removal of Fe(III)-EDTA was completed within 30 min at molar ratios of hydrogen peroxide to the initial Fe(III)-EDTA higher than 24.7.

Degradation of Sulfonamide Antibiotic Substances by Ozonation: An Experimental and Computational Approach (설폰아미드계 항생물질의 오존산화분해에 대한 계산화학적 해석 및 실험적 검증)

  • Won, Jung Sik;Lim, Dong Hee;Seo, Gyu Tae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.6
    • /
    • pp.442-450
    • /
    • 2014
  • Concern has grown over a presence of micropollutants in natural water since sulfonamide antibiotic substances such as sulfamethazine, sulfamethoxazole, sulfathiazole have been frequently detected in Nakdong River, Korea. The current work investigates the degradation of the three sulfonamide substances by using quantum chemistry calculations of density functional theory (DFT) and experimental measurement techniques of Fourier transform infrared spectroscopy (FT-IR) and ultraviolet-visible spectrophotometer (UV-VIS). DFT calculations demonstrate that the lowest energy gap between the highest occupied molecular orbital (HOMO) and the lowest unoccupied molecular orbitals (LUMO) lies in sulfanilamide functional group of sulfonamide, implying that the sulfanilamide functional group would be the most active site for ozone oxidation. Also, UV-VIS spectra and FT-IR analysis reveal that 260 nm band originated from sulfanilamide group was absent after ozone oxidation, indicating that a functional group of amine (N-H) was removed from sulfanilamide. Both theoretical and experimental observations agree well with each other, demonstrating the DFT calculation tool can be an alternative tool for the prediction of chemical reactions in purification treatment processes.

Investigation on Supporting Policies and Problems of Shale Gas Development in China (중국 셰일가스 개발 문제점과 지원정책 분석)

  • Lee, Chaeyoung;Yoon, Junil;Lee, Hong;Lee, Youngsoo;Shin, Changhoon
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.2
    • /
    • pp.54-65
    • /
    • 2015
  • China holding the world largest shale resources, has been trying to develop their domestic shale gas fields mainly with its NOCs. Chinese shale industry looks likely to have high potential to grow in the future, considering the eager support of Chinese government and the rapid development of relevant technologies by NOCs. However, there are opposite opinions as well that Chinese shale gas could not play a positive short-term results because of the complexity of structural geology, inadequacy of water resources and related infrastructure. Recently, Korean companies began to be interseted in Chinese shale gas industry, because of the special relationships with Korean industries in terms of geographic proximity and better opportunities due to the early phase of shale gas business in China. In this study, it was tried to help those companies looking out of future Chinese shale gas industry that surveying current status and problems of Chinese shale gas industry and relevant industries and investigating some trials and policies driven by China government. As a result, the various and long-term problems in Chinese shale development were reviewed and the active supports and polices of Chinese government, NOC's trials for establishments of their independent technologies and the cooperation with foreign companies or M&As were also investigated.

Effect of Period of Immersion on Corrosion Potential, Anodic Polarization, and Impedance Characteristics of Reinforced Steel in Mortar (W/C: 0.6) (모르타르(W/C:0.6)의 철근의 부식전위와 양극분극 및 임피던스 특성에 미치는 재령 년수)

  • Jeong, Jae-Hyun;Moon, Kyung-Man;Lee, Sung-Yul;Lee, Myeong-Hoon;Baek, Tae-Sil
    • Journal of Ocean Engineering and Technology
    • /
    • v.30 no.4
    • /
    • pp.327-333
    • /
    • 2016
  • Reinforced concrete structures have found wide usage in land and maritime applications. However, the corrosion of reinforced concrete has been recognized as a serious problem from economic and safety standpoints. In previous studies, the corrosion behavior of the inner steel bar embedded in mortar (W/C: 0.4, 0.5) was investigated using electrochemical methods. In this study, multiple mortar test specimens (W/C: 0.6) with six different cover thicknesses were prepared and immersed in flowing seawater for five years. Subsequently, equations related to the cover thickness, period of immersion, and corrosion characteristics of the embedded steel bar were evaluated using electrochemical methods. Prior to immersion, the corrosion potentials indicated an increase with increasing cover thickness, and after five years, all corrosion potentials demonstrated a trend in the positive direction irrespective of the cover thickness. However, the relationships between the corrosion potential and cover thickness were not in complete agreement. Furthermore, after five years, all of the corrosion potentials indicated values that were nobler compared to those obtained prior to immersion, and their corrosion current densities also decreased compared to their values obtained prior to immersion. It was considered that the embedded steel bar was easily corroded because of the aggression of water, dissolved oxygen, and chloride ions; a higher W/C ratio also assisted the corrosion process. The corrosive products deposited on the surface of the steel bar for five years cast a resistance polarizing effect shifting the corrosion potential in the nobler direction. Consequently, it was considered that the W/C ratio of 0.6 showed nearly same results as those of W/C of 0.4 and 0.5. Therefore, the corrosion potential as well as various parameters such as the cover thickness, period of immersion, and W/C ratio must be considered at once for a more accurate evaluation of the corrosion property of reinforced steel exposed to marine environment for a long period.