• 제목/요약/키워드: Water and wastewater treatment facilities

검색결과 181건 처리시간 0.03초

우수유출 모형을 이용한 합류식하수관로시스템의 월류량, 월류빈도 산정 기준 결정 연구 (Criteria for calculation of CSO volume and frequency using rainfall-runoff model)

  • 이건영;나용운;류재나;오재일
    • 상하수도학회지
    • /
    • 제27권3호
    • /
    • pp.313-324
    • /
    • 2013
  • It is widely known that untreated Combined Sewer Overflows (CSOs) that directly discharged from receiving water have a negative impact. Recent concerns on the CSO problem have produced several large scale constructions of treatment facilities, but the facilities are normally designed under empirical design criteria. In this study, several criteria for defining CSOs (e.g. determination of effective rainfall, sampling time, minimum duration of data used for rainfall-runoff simulation and so on) were investigated. Then this study suggested a standard methodology for the CSO calculation and support formalized standard on the design criteria for CSO facilities. Criteria decided for an effective rainfall was over 0.5 mm of total rainfall depth and at least 4 hours should be exist between two different events. An Antecedent dry weather period prior to storm event to satisfy the effective rainfall criteria was over 3 days. Sampling time for the rainfall-runoff model simulation was suggested as 1 hour. A duration of long-term simulation CSO overflow and frequency calculation should be at least recent 10 year data. A Management plan for the CSOs should be established under a phase-in of the plan. That should reflect site-specific conditions of different catchments, and formalized criteria for defining CSOs should be used to examine the management plans.

고전압 임펄스 기술을 활용한 슬러지 가용화 (Solubilization of wasted sludge using high voltage impulse technique)

  • 조승연;장인성
    • 상하수도학회지
    • /
    • 제31권3호
    • /
    • pp.257-262
    • /
    • 2017
  • Several disposal processes for waste sludge from wastewater treatment plants such as landfill, ocean dump, incineration, reuse as fuels or fertilizers are practiced. However, ocean dumping is prohibited by international treat. New constructions of landfill sites or incineration facilities are limited by NIMBY and reuse processes are still suffering from low energy yield. Therefore, development of alternative processes for sludge disposal are currently needed. In this study, alternative technique for sludge solubilization using HVI (high voltage impulse) was suggested and verified experimentally. Sludge solubilization was carried out for 90 minutes using HVI discharge with peak voltage of 16 kV and pulse duration for 40 microsecond. About 3~9 % of MLSS and MLVSS concentration were reduced, but the soluble COD, TN, TP of the sludge increased to 372 %, 56 % and 102 % respectively. It indicates that the flocs and/or cells of the sludge were damaged by HVI. These resulted in flocs-disintegration and cells-lysis, which means the internal matters were bursted out of the flocs as well as the cells. Thus, electrical conductivity in bulk solution was increased. All of the results verified that the HVI could be used as an alternative technique for sludge solubilization processes.

산업폐수의 수처리를 위한 초전도 자기분리 장치 제작 (Superconducting Magnetic Separator for Purification of Industrial Wastewater)

  • 하동우;권준모;고락길;백승규;손명환;이유진;김태형
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.44-44
    • /
    • 2010
  • Conventional water treatment facilities like precipitation process need large-scale equipment and wide space to purify the wastewater of paper factory. In case of massive waste water, high gradient magnetic separation (HGMS) parts are more effective to purify it rapidly and to occupy relatively small space, since large voids at filter with HGMS are adopted. Cryo-cooled Nb-Ti superconducting magnet with room temperature bore in diameter of 100 mm and 600 mm in height was used for magnetic separator. Magnetic filters were designed by the analysis of magnetic field distribution at superconducting magnets.

  • PDF

첨단 전자산업 폐수처리시설의 Water Digital Twin(I): e-ASM 모델 개발과 Digital Simulation 구현 (Water Digital Twin for High-tech Electronics Industrial Wastewater Treatment System (I): e-ASM Development and Digital Simulation Implementation)

  • 심예림;이나희;정찬혁;허성구;김상윤;남기전;유창규
    • 청정기술
    • /
    • 제28권1호
    • /
    • pp.63-78
    • /
    • 2022
  • 첨단 전자산업 폐수 처리시설에서 발생되는 유기 폐수는 고농도의 유기물질 및 20가지 이상의 유독 난분해성 물질을 포함하고 있으며, 이를 효율적으로 처리하는 것은 첨단 전자산업의 당면 과제이다. 따라서, 첨단 전자산업 유기폐수 처리시설을 CPS (Cyber physical system)상 Water digital twin으로 구축하여 COD (Chemical Oxygen Demand), TN (Total Nitrogen), TP (Total Phosphorous) 및 TMAH (Tetramethylammonium hydroxide) 등 유기 오염물질의 제거 효율 평가가 가능한 전자산업 폐수 특화 모델 개발이 필요하다. 본 연구에서는 첨단전자산업 유기폐수 제거 메커니즘에 대한 분해 미생물의 성장과 사멸의 이론적인 반응속도식에 기반한 첨단 전자산업 폐수 특화 활성슬러지 모델(Electronics industrial wastewater activated sludge model, e-ASM)을 개발하였다. 개발한 e-ASM은 전자산업 폐수처리공정에서 발생하는 유기물 산화, 질산화, 및 탈질화 과정뿐만 아니라 TMAH 등 난분해성 유기물질의 분해과정 중 발생하는 질산화미생물의 저해(Inhibition) 작용 등 복잡한 생물학적 분해 메커니즘이 모사 가능하다. 이를 활용하여 실제 전자산업 유기폐수 처리시설을 Water Digital Twin으로 구현하여 CPS (Cyber physical system) 상에서 전자산업 폐수처리장에 폐수 유입 성상에 따라 공정 모델링, 유출수 예측, 공법 선정, 설계 효율 평가 등 다양한 목적으로 활용될 수 있다.

하수처리시설 방류수 내 잔류 향정신성 의약품의 독성평가를 위한 zebrafish의 행동성 변화 연구 (A Study on the Behavior Change of Zebrafish For Toxicity Evaluation of Residual Psychoactive Medication in Wastewater Treatment Plant Effluent)

  • 윤효직;김민재;김종락;김성표
    • 한국물환경학회지
    • /
    • 제35권6호
    • /
    • pp.574-579
    • /
    • 2019
  • As interest in health issues increases, it is imperative to ensure good water quality from wastewater treatment plant effluent to preserve environmental health. In particular, currently there is a lack of water ecosystem risk assessment on pharmaceutical substances remaining in effluent. In this study, antidepressant escitalopram (ESC), antiepileptic carbamazepine (CBZ) and lead, which impact the behavior of aquatic organisms, were used to test their impact on the potential behavior of zebrafish. Zebrafish have been widely used in toxicological assessment studies due to the ease of handlinggenerically and genetically. It was possible to observe changes in the growth of organisms through monitoring the embryos' cognitive and behavior assessment. In this study, the embryo lethal dose test showed that the lethal concentration of ESC and CBZ was at 10 ppb, which is below the water quality criterion (100 ppb), increased by 32.5 % and 40 %, respectively. In the cognitive test, it was found that the cognitive ability function decreased by 22 % and 17% for ESC(500 ppb) and CBZ(1,000 ppb) respectively relative to control. Based on these results, it is necessary to initiate efforts to remove these trace pollutants from sewage treatment facilities to protect the health of aquatic organisms.

하수역학 구축을 위한 시료 전처리 기술과 신속검출기술 (Pretreatment and Rapid Detection Methods for Wastewater-Based Epidemiology)

  • 이재엽;이복진;제스민아터;안창혁;김일호
    • 한국물환경학회지
    • /
    • 제39권1호
    • /
    • pp.102-110
    • /
    • 2023
  • Wastewater Based Epidemiology (WBE) provides useful information not only on the use of illegal drugs in the community, but also on the presence of hygiene and health products and infectious pathogens in sewage facilities. As a consequence of the SARS-CoV-19 virus epidemic in 2019, monitoring the status of the infection is of utmost importance. SARS-CoV-19 was also detected in sewage, and the number and trend of infections in the community suggest that the application of the WBE system would be useful and appropriate. This study introduces a pre-treatment concentration method including viruses in sewage samples. A total of seven methods which were subdivided into methods for adsorption-extraction, ultra-filtration, PEG precipitation, and ultra-centrifugation, and the results for analyzing the recovery rates were included. Meanwhile, it is necessary to pay attention to rapid detection technologies which analyze infectious pathogens at the site of sewage facilities. These can include ELISA, FTIR, SERS, and biosensor based on the detection principle, and the characteristics, advantages, and disadvantages of each were summarized herein. If rapid detection technologies and accurate quantitative analyses are further developed, the use of sewage mechanics in response to pandemic viruses is expected to expand further.

생활폐기물 소각시설의 운영 실태 분석을 통한 에너지회수 효율 개선방안 검토 (A Study on Improvement Measures of Energy Recovery Efficiency through Analysis of Operational Status of Municipal Solid Waste Incineration Facilities)

  • 박상진;배재근
    • 한국폐기물자원순환학회지
    • /
    • 제35권8호
    • /
    • pp.762-769
    • /
    • 2018
  • This study was carried out to examine the improvement plan by analyzing the characteristics of imported wastes, operation rate, and benefits of energy recovery for incineration facilities with a treatment capacity greater than 50 ton/day. The incineration facility capacity increased by 3,280 tons over 15 years, and the actual incineration rate increased to 2,783 ton/day. The operation rate dropped to 76% in 2010 and then rose again to 81% in 2016. The actual calorific value compared to the design calorific value increased by 33.8% from 94.6% in 2002 to 128.4% in 2016. The recovery efficiency decreased by 29% over 16 years from 110.7% to 81.7% in 2002. Recovery and sales of thermal energy from the incinerator (capacity 200 ton/day) dominated the operation cost, and operating income was generated by energy sales (such as power generation and steam). The treatment capacity increased by 11% to 18% after the recalculation of the incineration capacity and has remained consistently above 90% in most facilities to date. In order to solve the problem of high calorific value waste, wastewater, leachate, and clean water should be mixed and incinerated, and heat recovery should be performed through a water-cooled grate and water cooling wall installation. Twenty-five of the 38 incineration facilities (about 70%) are due for a major repair. After the main repair of the facility, the operation rate is expected to increase and the operating cost is expected to decline due to energy recovery. Inspection and repair should be carried out in a timely manner to increase incineration and heat energy recovery efficiencies.

생활폐기물 소각시 요구되는 요소수의 대체물질로 음식물 폐수 속의 암모니아 적용에 관한 연구 (A Study on Investigate the Suitability of ${NH_4}^+$ Applications of Food Waste Water Instead of Urea in the Incineration of Municipal Solid Waste)

  • 고성규;조용균;이영신
    • 유기물자원화
    • /
    • 제20권4호
    • /
    • pp.97-105
    • /
    • 2012
  • 본 연구는 음식물류 폐기물의 처리과정에서 발생하는 음식물류 폐수를 생활폐기물 소각시설에서 생활폐기물과 음식물류폐수를 혼합하여 소각처리 방법과 소각시 음식물류 폐수를 이용한 질소산화물 제거 및 배출가스의 영향등을 조사하였다. 해양투기용으로 발생된 음식물류폐기물 폐수는 성상이 94-96%의 함수율을 갖고 있다. 음식물류폐기물 폐수를 주입하였을 때 소각로 출구 온도는 $897^{\circ}C$이였으며, 평상시는 $925^{\circ}C$로 약 $28^{\circ}C$도 떨어졌다. 음식물류폐기물 폐수를 각각 $200{\ell}/hr$, $300{\ell}/hr$ 투입시 질소산화물의 평균배출농도는 각각 50ppm, 46ppm 이었다. 연관식 폐열보일러는 음식물류 폐수의 투입량이 많을수록 튜브 막힘 현상이 있었으며, 막힘 튜브는 압축공기를 이용한 튜브 청소로 원상태를 유지 할 수 있어 연속적 소각에는 방해가 되지 않았다. 유기성 폐기물인 음식물류 폐수의 자원화 처리방법과 더불어 기존 소각시설을 이용한 소각처리가 육상처리의 한 방법으로 자리매김 할 수 있으며, 소각시 배출가스의 질소산화물이 제거됨으로써 질소산화물 제거용 암모니아, 요소수 등 화학약품비용 절감하는 효과도 있는 것으로 나타났다.

유입원수 조류제거를 위한 high rate DAF 최적화 연구 (High Rate Dissolved Air Flotation (DAF) for the Removal of Algae Species)

  • 정우식;안주석;송근원;오현제
    • 상하수도학회지
    • /
    • 제31권5호
    • /
    • pp.415-419
    • /
    • 2017
  • In recent years there have been large increases in the hydraulic loading rates used to design dissolved air flotation (DAF) facilities for drinking water applications. High rate DAF processes are now available at loading rates of 20 to $40m^3/m^2{\cdot}h$. This research evaluated dissolved air flotation as a separation method for algae and organic compounds from water treatment plants. During the service period of 2016. 5. to 2017. 6., DAF pilot plants ($500m^3/day$) process has shown a constantly sound performance for the treatment of raw water, yielding a significantly low level of turbidity (DAF treated water, 0.21~1.56 NTU). As a result of analyzing the algae cell counts in the influent source, it was expressed at 100-120 cells/mL. In DAF treated water, the removal efficient of alge cell counts was found to be upto 90%. The stable turbidity and algae removal were confirmed by operating the high rate DAF process under the condition of the surface loading rate of $30m^3/m^2{\cdot}hr$.

효율적 빗물관리를 위한 하수도 요금체계 개편 방안 (The improvement of sewerage fee imposition system for efficient rainwater management)

  • 박규홍;강병준;박주양;박완규;김성태
    • 상하수도학회지
    • /
    • 제28권5호
    • /
    • pp.517-527
    • /
    • 2014
  • As sewer flooding frequents due to localized and concentrated stormwater and increased non-permeable surface area after urbanization, building cities with sound water recycle and accordingly efficient management of rainwater is demanded. To do this, the existing sewage (including rainwater) fee imposition system should be philosophically evaluated. This study presents problematic issues of the existing domestic sewage fee imposition system considering the principle of sharing costs on the service of sewage and rainwater collection and treatment. Four methods to improve the existing sewage fee imposition system are suggested: 1) imposing stormwater fee according to Polluter Pays Principle, 2) clarification of the share of public sector, 3) reducing or exempting the sewerage fee for inhabitants reducing urban runoff by constructing their own rainwater management facilities, 4) imposing charge for discharging rainwater to sewers due to new development action. Short, mid, or long term planning for rainwater management is recommended considering the situation of each municipality.