• Title/Summary/Keyword: Water Resistivity

Search Result 385, Processing Time 0.03 seconds

Geophysical Surveys for Mapping of the AMD Contaminant Channels at an Abandoned Mine (폐광산의 AMD 오염영역탐지를 위한 지구물리탐사)

  • 김지수;최상훈;한수형
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2000.11a
    • /
    • pp.258-261
    • /
    • 2000
  • Geophysical surveys (electrical resistivity, self-potential, and magnetic methods) and streamwater sample analysis have been carried out at a site of tailings of waste deposits in an abandoned mine, Jangpoong, which is situated in Kowesan-Gun, Chungbuk-Do. The research was aimed at investigating the suitability of the various geophysical methods for detection of AMD (acid mine drainage) paths, and ultimately mapping of preferred AMD flow channels by incorporating the water sample analysis. Electrical resistivity section from the dipole-dipole line represents the low-resistivity zone trending northwest toward the stream nearby. The positions of the resistivity anomalies for AMD channels are well correlated to the ones from the various geophysical surveys. In addition they correspond to the sites of the higher peaks for the pH, EC, heavy metal content for the water sample data.

  • PDF

Application of Electrical Resistivity Measurement to an Evaluation of Saline Soil in Cropping Field (염류집적 농경지에서 전기비저항 탐사기법의 활용성)

  • Yoon, Sung-Won;Park, Sam-Gyu;Chun, Hyen-Jung;Han, Keung-Hwa;Kang, Seong-Soo;Kim, Myung-Suk;Kim, Yoo-Hak
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.44 no.6
    • /
    • pp.1035-1041
    • /
    • 2011
  • Salinity of soil under the plastic film houses in Korea is known as a significant factor to lower the crop production and to hamper the sustainable agricultural land management. In this study we propose a field monitoring technique to examine the methods applied to minimize the adverse effect of salts in soil based on the relationship between soil electrical characteristics and soil properties. Field experiments for 4 different treatments (water only, fertilizer only, DTPA only, and DTPA and fertilizer together) were conducted on soils at the plastic film house built for cultivating a cucumber plant located at Chunan-si, Chungchungnam-do in Korea. The electrical resistivity was measured by both a dipole-dipole and wenner multi-electrodes array method. After the electrical resistivity measurement we also measured the soil water content, temperature, and electrical conductivity on surface soil. The resulted image of the interpreted resistivity by the inversion technique presented a unique spatial distribution depending on the treatment, implying the effect of the different chemical components. It was also highly suspected that resistivity response changed with the nutrients level, suggesting that our proposed technique could be the effective tool for the monitoring soil water as well as nutrient during the cropping period. Especially, subsoils under DTPA treatment at 40 to 60 cm depth typically presented lower soil water accumulation comparing to subsoils under non-DTPA treatment. It is considered that DTPA resulted in increase of a root water uptake. However, our demonstrated results were mainly based on qualitative comparison. Further experiments need to be conducted to monitor temporal changes of electrical resistivity using time lapse analysis, providing that a plant root activity difference based on changes of soil water and nutrients level in time.

Geoelectrical laboratory and field studies of groundwater occurrence in a landslide area: a case study from Japan (전기비저항탐사에 의한 산사태 지역의 지하수조사)

  • Park Sam-Gyu;Asano Shiho;Matsuura Sumio;Okamoto Takashi;Kim Jung-Ho
    • Geophysics and Geophysical Exploration
    • /
    • v.8 no.1
    • /
    • pp.86-91
    • /
    • 2005
  • We present the results of electrical resistivity surveys carried out to estimate the seasonal variation of the water table level in a large-scale landslide area of Tertiary geology in Japan. One long profile, trending NE-SW, was established perpendicular to the main regional geology of the region. Three boreholes are located very close to the profile. The profile was surveyed twice, once before snowfall and once after snow had melted. The relationship between resistivity and water saturation of pyroclastic materials was clarified through laboratory tests. We did this in order to estimate the water content of the pyroclastic layer from the observed resistivity distribution in the landslide area. The resistivity of the saturated pyroclastic deposit calculated using an empirical formula was found to be $570{\Omega}.m$. Based on this computed resistivity, the groundwater level was deduced by assuming that the pyroclastic deposits were fully saturated beneath the water table. We show that the estimated water table before snowfall is lower than that inferred after snow has melted, by about 1.1 to 4.7 m. This suggests that the water table in the upper part of the pyroclastic layer in the landslide area fluctuates greatly, compared to the lower part. This seasonal groundwater fluctuation is possibly caused by the infiltration of water into the subsurface after snowmelt.

Electrical Resistivity Response Due to the Variation of Embankment Shape and Reservoir Level (제체형태와 수위에 따른 전기비저항 반응 연구)

  • Oh, Seok-Hoon
    • Geophysics and Geophysical Exploration
    • /
    • v.11 no.3
    • /
    • pp.214-220
    • /
    • 2008
  • The distortion effect of electrical response for two-dimensional (2-D) DC resistivity method was verified in terms of 2-D inversion result of synthetic data obtained by three-dimensional (3-D) modeling, which is frequently applied to assess the safety of center core-type fill dam structure. The distortion effect is due to 2-D interpretation for 3-D structure. By the modeling analysis, we found that the water level is correctly described in the resistivity section around the middle part rather than each end side of the embankment due to the 3-D terrain effect, when the material of the embankment is assumed as horizontally uniform. And when we set the slope of outer rock fill part as uniform. the sharper the slope of the center core is, the more similar the resistivity section reflects. On the other hand, when the slope of the rock fill is steep, the resistivity section shows the water level at lower position than the real one, and the 3-D distortion effect at the end side of the embankment was enhanced.

Application Techniques of 2D-Resistivity Structure for Estimation of Inferred Fracture Zone in Weathered Slope (풍화사면에서의 추정파쇄대 평가를 위한 2차원 전기비저항 구조도 적용 기법)

  • Kim, Jae-Hong;Park, Chal-Sook;Lee, Hyun-Jae;Jeong, Gyo-Cheol
    • The Journal of Engineering Geology
    • /
    • v.19 no.3
    • /
    • pp.323-330
    • /
    • 2009
  • Electrical resistivity survey is applied for estimation of inferred fault and fractured zone in civil engineering and environment field. While 15 m diameter and 3 lines tunnels are excavated. It is recognized that core stone and fractured zone is existed in the weathered slope of the entrance to a tunnel. To make confirmation geological characteristics, dipole-dipole electric resistivity survey was carried out in weathered slope of the entrance to a tunnel. Core stone distribution and fracture zone characteristics are estimated by reverse analysis and 2D-resistivity structure using FDM.

Groundwater Investigation in Northwestern Part of Saudi Arabia (Saudi Arabia 북서부의 지하수조사)

  • 한정상;정수웅
    • Water for future
    • /
    • v.8 no.2
    • /
    • pp.30-40
    • /
    • 1975
  • Hydrogeological survey and geophysical prospecting have been carried out in Saudi Arabia for the purpose of finding groundwater in the soil and rock at the request of General trading company in Jeddah, Saudi Arabia. The surveyed area is located on $38^{\circ}-39^{\circ}$ 30' in longitude and $26^{\circ}-26^{\circ}$ 30' in latitude. The topography of this area is dominated by northwest southeast mountain range composed mostly of precambrian rocks and basalt of tertiary period. Geology is mainly composed of greenstone, granite, andesite, diorite rhyolite of pre-cambrian era and sandstone of cambrian period which are underlained by basalt and andesite of tertiary period and alluvium of quaternary unconformably. The instruments used in this investigation are TR-18B2 radioactivity unit which isjapanese patented and A.C. Terrameter, a resistivity meter manufactured by ABEM of Stockholm, Sweden. Radioactivity method has been conducted along the Alula-Khaybar road, totally 164Km by the car-borne. As a result of the above survey 16 places have been selected and these anomalies show 1.2N-1.6N compared to background of each area in intensity with width of 10-50m. Resistivity vertical profiling which made use of Schlumberger configuration method has been made over selected areas by radioactivity method to provide hydrogeological information for a water resources survey. The result of resistivity shows that good aquifers are located in the western part of surveyed area where sedimentary rock is distributed. The strata showing 10-50, ${\Omega}-m$ in resistivity are thought to be waterbearing layer. The variations in aquifer resistivity found, are thought to be due to verying clay content, which could be related to aquifer yield. It has proved impossible to detect small salinity variation in the buried aquifer by geophysics. As a result of resistivity prospecting 10 places are recommended to be drilled at the anomalies as shown attached map. yields from the proposed holes have been estimated approximately from $20m^3$ to $200m^3$ per day. Prior to drilling for groundwater, test boring using ${\c}4"$ should be drilled in order to obtain more reliable hydrogeological information for the construction of perfect wells.ells.

  • PDF

Frequency-Dependent Resistivity and Relative Dielectric Constant of Soil on Water Content (수분함유량에 따른 토양의 저항률 및 비유전율의 주파수의존성)

  • Choi, Jong-Hyuk;Cha, Eung-Suk;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.1
    • /
    • pp.98-104
    • /
    • 2010
  • In order to evaluate the performance of a grounding system against lightning or fault currents including high frequency components, the grounding impedance should be considered rather than the steady state ground resistance. To evaluate the ground impedance, the frequency dependence of resistivity and relative dielectric constant of the soil have to be analyzed. This paper deals with the frequency dependence of the resistivity and relative dielectric constant of three types of soil on water content. As a result, the resistivity of soil is getting lower with increasing of water content. It is nearly independent of the frequency in the range less than 1[MHz], and is decreased over the frequency range above 1[MHz]. On the other hand, the relative dielectric constant is rapidly decreased with the frequency in the range less than 1[MHz], but it is nearly independent on the frequency over the range of 1[MHz]. It was found from the experiments that the frequency-dependant resistivity and relative dielectric constant of soil should be considered when designing the grounding systems for protection from lightning or switching surges.

Mortar Characterization using Electrical Resistivity Method (모르타르의 전기비저항 특성)

  • Farooq, Muhammad;Park, Sam-Gyu;Song, Young-Soo;Kim, Jung-Ho
    • Geophysics and Geophysical Exploration
    • /
    • v.12 no.2
    • /
    • pp.215-220
    • /
    • 2009
  • Cement based mortars are widely used to improve the soft ground of a dam site, highway construction, and karst voids. The mechanical properties of the mortar are well documented in literature, however very limited work is done on their physical properties such as electrical resistivity which is considered as one of the most important physical property known while improving the soft grounds. In this paper, electrical resistivity of the Portland cement mortars is examined by employing the Wenner technique. Cylindrical specimens with various water/cement ratios (w/c) ranges from 0.35, 0.45, 0.50 and 0.65 were cast and tested. The test results showed that the electrical resistivity of the mortar increases with increasing curing time and decreases with increasing water content and w/c. A reasonable, good relation was found between electrical resistivity and compressive strength of mortar.

IP Characteristics of Sand and Silt for Investigating the Alluvium Aquifer (충적대수층 조사를 위한 모래와 점토의 유도분극 특성 고찰)

  • Choi, Sang-Hyuk;Kim, Hyoung-Soo;Kim, Ji-Soo
    • The Journal of Engineering Geology
    • /
    • v.18 no.4
    • /
    • pp.423-431
    • /
    • 2008
  • In general, water-saturated silt or clay alluvium is characterized with relatively low-resistivity. Thus we often encountered the problem that such a low-resistivity layer is misguided to be good aquifer of high-permeability and low-resistivity in the development of groundwater. This research was conducted with an emphasis on the identification of saturated silt or clay layer from the aquifer by performing the laboratory experiment of IP and resistivity methods on the various materials consisting of alluvium aquifer. Silt or clay layer is found to be characterized with the higher chargeability zone, compared to the sand layer. Regarding the mixture of sand and clay, the higher clay volume, the lower resistivity and the higher chargeability. Subsequently chargeability decreases.

Validation of a new magnetometric survey for mapping 3D subsurface leakage paths

  • Park, DongSoon;Jessop, Mike L.
    • Geosciences Journal
    • /
    • v.22 no.6
    • /
    • pp.891-902
    • /
    • 2018
  • Techniques for more reliable detection of 3D subsurface flow paths are highly important for most water-related geotechnical projects. In this case study, a magnetometric resistivity method with a new approach and state-of-the-art technology ("Willowstick survey") was applied to the testbed dam (YD dam) site, and its applicability was validated by geotechnical investigation techniques including borehole drilling and sampling, Lugeon test, flow direction and velocity test, and seismic tomography. In addition to the magnetometric survey, a 3D electrical resistivity survey was performed independently and the results were compared and discussed. The electrical resistivity survey was effective in detecting groundwater levels, but it was limited in mapping leakage paths. On the other hand, the Willowstick magnetometric survey effectively detected geologic weaknesses (e.g., fault fracture) and potential leakage paths of the dam site foundation rocks. The results of this research are expected to be effective for water infrastructures where leakage is an important issue.