• 제목/요약/키워드: Water Meters

검색결과 331건 처리시간 0.032초

20~50mm 수도계량기 미감지율 조사분석 (Investigation on Under-registration of 20 mm to 50 mm Water Meters)

  • 안재찬;하성호;박태준;김석정;구자용
    • 상하수도학회지
    • /
    • 제19권5호
    • /
    • pp.582-594
    • /
    • 2005
  • The under-registration of water meters of 20mm to 50mm in diameter, installed in Seoul city, was estimated by random sample method. The sample sites and sampled meters were selected for the measurements of flow rates and accuracy tests, respectively. The measurement of flow rates was conducted for 20mm to 50mm meters for about 20 days per site using flow meters and data loggers. The under-registration of 20mm, 25mm, 32mm, 40mm, and 50mm meters was observed as 3.96%, 1.10%, 2.47%, 4.04%, and 1.04%, respectively. The under-registration might be increased more or less as malfunction and failure of the sampled meters was not considered. In this study the under-registration of 20mm, 25mm, 32mm, 40mm, and 50mm meters was accurately estimated on the basis of the investigation data. The estimation of under-registration of water meters, one of the basic figures in water industry, contributed to accurate calculation of leakage, water supply and consumption, and strategic planning to reduce the unaccounted-for water.

가정용 13mm 수도계량기 미감지율 조사연구 (A Study on Under-registration of 13mm Water Meters)

  • 안재찬;하성호;정판식;최정섭;구자용
    • 상하수도학회지
    • /
    • 제19권4호
    • /
    • pp.506-514
    • /
    • 2005
  • Unaccounted-for water subtracting water sold from produced water includes leakage, under-registration, unauthorized use, etc. To improve accounted-for water ratio, firstly, it should be attempted to accurately identify where unaccounted-for water is, and then it must to be reduced. Under-registration of meter is caused by allowable tolerance of meter, improper size of meter installed, gradient installation, etc. Under-registered water of meters has ever been the second large amount of unaccounted-for water next to leakage, but still is not estimated exactly. In this study, the estimated value as under-registered water was obtained by using the selected-area modeling program. As a result, the under-registered water ratio of 13mm meters was approximately 1.23%. Those of meters according to ages 1, 3, and, 5 years old were 1.46% 2.77% and, 2.26%, respectively but that of 7 years old meters showed over-registration of 1.59%.

저유수량의 소실률 조사연구 (A Study on Sediment Deposite in Reservoir)

  • 엄태영
    • 한국농공학회지
    • /
    • 제10권1호
    • /
    • pp.1413-1419
    • /
    • 1968
  • Yochon reservoir was consturcted with an original storage capacity of 202.7 chung-meters. This reservoir receives the water from watershed area of 933.0 chungbo and has irrigated area of 478.0 chungbo. In 1967 a detailed capacity survey of this reservoir was carried out by a new depth-recorder under the scheme of reservoir sedimentation of Agricultural Engineering Research Center. Significant findings are 1. The capacity of the reservoir for the water storage has been reduced by 8.9%(18.066 chung-meters out of the 202.7 chung-meters) since its construction, a period of just 39.0 years. 2. The sediment accumulation in the reservoir represents an average annual soil loss of 0.496mm depth(0.463 chung-meters) of soil from the watershed area of 933.0 chungbo. Eventually the capacity of the reservoir for the water storage will be reducing by about 25%(50.7 chung-meters out of the 202.7 chung-meters)in one hundred years since its construction. We have to set up controlling projects for those reservoir protections from the sediment, soil loss, and other failures. The depth recorder is very useful, convenient, and accurate machine for surveys of reservoir capacity and other river surveys.

  • PDF

상수도 원격 검침 데이터 송수신 위한 Client/Server 소켓 프로그램 개발 (Development of a Client/Server Socket Program using Remote Measurement of Digital Water Meters)

  • ;박용만;권종원;김희식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.153-155
    • /
    • 2006
  • An automatic remote water measurement system was developed. This system sends automatic remote measured and collected water meters data automatically from the transmitter with CDMA modem through SK-Telecom network The water meter data are received through LAH TCP/IP and displayed as test file on IE(Internet Explorer) window. The existing water meters of mechanical type have so many problems to measure data. The person must visit the location of each water meters and write down the data records manually. In this system the RF module has attached each water meter Client/Server programs are developed by network socket programming.

  • PDF

국외 상수도 원격검침시스템의 개발 동향 및 현장 적용 사례 고찰 (Recent Developments and Field Application of Foreign Waterworks Automatic Meter Reading)

  • 주진철;안호상;안창혁;고경록;오현제
    • 대한환경공학회지
    • /
    • 제34권12호
    • /
    • pp.863-870
    • /
    • 2012
  • 본 연구에서는 디지털 수도계량기(smart water meter) 연계형 상수도 원격검침시스템(automatic meter reading)의 국외 시장동향 및 원격검침시스템의 각 구성 요소기술의 개발현황과 현장적용 사례 등을 조사 분석하였다. 국외의 디지털 수도계량기 제조업체는 주로 미국 또는 유럽업체들로서 최근에는 북미뿐만 아니라 아시아 및 유럽에서도 원격검침시스템 사업을 확장하고 있다. 대부분의 디지털 수도계량기 제조업체는 원격검침용 디지털 수도 계량기에서 측정된 데이터를 활용하여 실시간 소비량 검침 및 비용 고지, 절수, 누수탐지, 수질 모니터링, 유량제어 등의 기능이 부가된 통합관리시스템(integrated water management system)과 연계하여 운영하고 있다. 데이터 전송방식은 디지털 수도계량기, 센서를 통해 검출된 데이터를 근거리 통신망(neighborhood area network)을 통해 수집기(data concentration unit)로 전송 후 광역 통신망(wide area network)을 통해 검침서버로 전송하였으며, 데이터 전송방식은 도시 규모, 계량기의 밀도, 전력공급 여부 및 통신망의 설치 여부 등을 종합적으로 고려하여 결정되었다. 일반적인 검침방식은 (1) 고정망(fixed network)을 통한 중앙 검침, (2) 차량(drive by)을 이용한 검침, (3) 사람(walk by)에 의한 검침, 그리고 (4) 비행식(fly by) 검침방식 등이 적용되었다. 전 세계적으로 디지털 수도계량기 연계형 원격검침시스템이 확산되어 용수 및 에너지를 절감하고 수도 요금을 절약하여 온실가스의 배출을 최소화하고 있는 것으로 판단된다.

Open-channel discharges evaluation by the application of smart sensors

  • Khatatbeh, Arwa;Kim, Young-Oh
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2022년도 학술발표회
    • /
    • pp.138-138
    • /
    • 2022
  • Understanding a stream's or river's discharge is essential for a variety of hydrological and geomorphological applications at various sizes. However, depending on the stream environment and flow conditions, it is crucial to use the appropriate techniques and instruments. This will ensure that discharge estimations are as reliable as possible. This study presents developed smart system for continuous measurement of open channel discharge and evaluate streamflow measurement over various techniques. This includes developed smart flow meter as flow point measurements, smart water level sensor (installed on Hydraulic Structure ? Weir) and current meters. Advantages and disadvantages of each equipment are presented to ensure that the most appropriate method can be selected. we found that smart water level sensor is more prominent once used during flood event as compared to smart flow meter and current meters, while current meters seems to show better accuracy once applied for open channel.

  • PDF

Characteristics of Stability and Intensity of Vertical Transfer in the Western Channel of the Korea Strait

  • Chung, Jong Yul
    • 한국해양학회지
    • /
    • 제10권2호
    • /
    • pp.57-66
    • /
    • 1975
  • Structure of thermocline, characteristics of stability and intensity of vertical transfer have been studied with hourly oceanographic data in each layers on Line 207 from 1968 to 1969. It is found that a typical thermocline is formed at depths of 10 to 50 meters in summer and early autumn and its core is located near depths of 25 meters. The maximum diffusion coefficient of vertical turbulent is found to be 140$\textrm{cm}^2$/sec at the surface layer(i.e., 0-10 meters), while the minimum is 5$\textrm{cm}^2$/sec at depths of 25 meters, consistent with characteristics of stability and structure of thermocline layers. Our computed diffusion coefficient and stability indicate that the mixing hardly takes place below depths of 80 meters during summer and early autumn, but for the rest of the season mixing could move up to the depth of 50 meters. It appears that the Western Channel of the Korea Strait consist of three different water masses during summer and autumn, and for the rest of the season, two kinds are present.

  • PDF

사대강유역의 지하수 (Ground water in the four major basins in Korea)

  • 최승일
    • 물과 미래
    • /
    • 제12권1호
    • /
    • pp.21-27
    • /
    • 1979
  • Ground water stored in the alluvium and the rocks provides the vase flow of the streams and can be withdraw from wells and infiltration galleries. And it is also recharge naturallyby precipitation. The amount of ground water in the four major basins it is estimated to be about 137,000 million cubiv meters(Table1), while nationwide ground water storage to be about 232,000 million cubic meters. The estimation of storage volume has been made on the basis of assumed thickness of the saturated zone of the different rocks and assumed porosities of those rocks. The values of the porosity of alluvium and saprolite were assumed to be 25% and 40% respectivvely which are based on tests made of similar materials in Georgia, U.S. The volume of water in storage is believed to be a conservative estimate. Detailed geologic and hydrologic investigation should be made where and when water resources are needed.

  • PDF

Model Test of a TLP Type of Floating Offshore Wind Turbine, Part II

  • Dam, Pham Thanh;Seo, Byoung-Cheon;Kim, Jae-Hun;Shin, Jae-Wan;Shin, Hyunkyoung
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 추계학술대회 초록집
    • /
    • pp.38.2-38.2
    • /
    • 2011
  • A large number of offshore wind turbines with fixed foundations have been installed in water depths up to 30 meters supporting 3-5MW wind turbines. Some floating platform concepts of offshore wind turbines were designed to be suitable for deployment in water depths greater than 60 meters. However the optimal design of this system in water depth 50 meters remains unknown. In this paper, a 5-MW wind turbine located on a TLP type platform was suggested for installation in this water depth. It is moored by a taut mooring line. For controlling the wind turbine always be operated at the upwind direction, one yaw controlling was attached at the tower. To study motion characteristics of this platform, a model was built with a 1/128 scale ratio. The model test was carried out in various conditions, including waves, winds and rotating rotor effect in the Ocean Engineering Wide Tank of the University Of Ulsan (UOU). The characteristic motions of the TLP platform were captured and the effective RAOs were obtained.

  • PDF