A Study on Under-registration of 13mm Water Meters

가정용 13mm 수도계량기 미감지율 조사연구

  • 안재찬 (서울특별시 상수도연구소) ;
  • 하성호 (서울특별시 상수도연구소) ;
  • 정판식 (서울특별시 상수도연구소) ;
  • 최정섭 (서울특별시 상수도연구소) ;
  • 구자용 (서울시립대학교 환경공학과)
  • Received : 2005.07.01
  • Accepted : 2005.08.09
  • Published : 2005.08.15

Abstract

Unaccounted-for water subtracting water sold from produced water includes leakage, under-registration, unauthorized use, etc. To improve accounted-for water ratio, firstly, it should be attempted to accurately identify where unaccounted-for water is, and then it must to be reduced. Under-registration of meter is caused by allowable tolerance of meter, improper size of meter installed, gradient installation, etc. Under-registered water of meters has ever been the second large amount of unaccounted-for water next to leakage, but still is not estimated exactly. In this study, the estimated value as under-registered water was obtained by using the selected-area modeling program. As a result, the under-registered water ratio of 13mm meters was approximately 1.23%. Those of meters according to ages 1, 3, and, 5 years old were 1.46% 2.77% and, 2.26%, respectively but that of 7 years old meters showed over-registration of 1.59%.

Keywords

References

  1. 내무부 (1987) 상수도누수방지사업종합보고서
  2. 서울특별시 상수도사업본부 (2004) 상수도통계연보
  3. 안재찬 (1996) 누수공에서의 누수량 산정 실험, 서울특별시 상수도연구소 1996년 수도연구집
  4. 안재찬 (1996) 수도계량기 정밀도에 관하여, 수자원환경 제 88호(1996.4). pp.32-35
  5. 안재찬 (1997) 가정용 13mm 수도계량기의 성능에 관한 연 구, 서울특별시 상수도연구소 1996년 수도연구집
  6. 안재찬 (1998) 상수도 배급수 분야의 R&D(일본 동경도, 오사카시를 중심으로). 서울특별시 시정연구논총 새 서울터전 5(2). pp.74-81
  7. 안재찬, 하성호, 정판식, 최정섭, 이규성 (2000) 유수율 제고를 위한 수도계량기 성능평가 연구' 새천년 서울 상수도기술세미나, 대한환경공학회 서울특별시 상수도연구소2000. 9. 1
  8. 안재찬, 박태준, 김석정, 이규성 (2002) 수도계량기 미감지율 조사연구, 한국상하수도협회 상수도연구검사기관 협의회 2002. 11. 13
  9. 환경부 (1999) '98 상수도통계
  10. 현인환 (2003 ) 서울시 관망관리의 현황과 과제, 서울특별시 수질평가위원회 2003 심포지움, 서울특별시 수돗물수질평가위원회2003. 11. 25
  11. 현인환 등 (2003) 2003년 누수보고서, 환경부
  12. 日本水路協會 (1977) 漏水防止對策指針
  13. 漏水防止に關lする調査険討會(1996) 漏水防止に關する調査報告書, 日本水道技術硏究 センタ一
  14. 小村康彦, (1988) 水道管路の硏究開設の方向, 日本水道技術硏究 センタ一
  15. Ahn, J. C, Choi, J. S., Lee, C. S., Koo, J. Y (2002) Underregistration of water meters in Seoul City, 日本水道協會第53回全國水道硏究發表會. 2002. 5. 29-31. pp. 694-695
  16. Ahn, J. C, Lee, S. W., Lee, C. S., Koo, J. Y. (2005) Predicting water pipe breaks using neural network, In Proceedings of Conference on Efficient use and Management of urban water, Santiago Chile, 15-17 March 2005, IWA Publishing, pp.472-481
  17. AWWA LDWA committee (1996) Committee report: Water Accountability, J. AWWA, 88(7), pp. J 08-111
  18. AWWA (1990) Water Audits and Leak Detection (M36)
  19. California Section Committee Report (1966) Determination of Economic Period for Water Meter Replacement, J. AWWA, 58(6), pp. 642-650 https://doi.org/10.1002/j.1551-8833.1966.tb01625.x
  20. Miguel, C. D., Nontesinos, M. P., Ayuso, J. L., Galisteo, M. (1999) A Comprehensive study of water consumption in the city of Cordoba Spain, Aqua, 48(2) pp. 64-72
  21. Tao, P. (1982) Statistical sampling techniques for controlling the accuracy of small meters, J. AWWA, 74(6), pp. 296-304 https://doi.org/10.1002/j.1551-8833.1982.tb04925.x