• Title/Summary/Keyword: 불감률

Search Result 8, Processing Time 0.026 seconds

A Study on Characteristics of Under Registration Rate for Water Meters to Increase the Accounted Water Rate (유수율 향상을 위한 수도미터의 불감률 특성 연구)

  • Lee, Dong-Keun;Park, Jong-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.8
    • /
    • pp.791-797
    • /
    • 2010
  • The reliability of a water meter for measuring the water flow-rate and subsequent analysis of the measured water depends on the accuracy of measurement. The under registration of a water meter causes many problems for operators, such as loss in revenue and a decrease in the rate of measured water. The purpose of this study is to support and development core technology, such as efficient operations management and adoption of the best mechanism for providing different services by experimentally. In this study, experiments were conducted using water meters with different diameters, manufacturers, years of usage and the specific uses. On the basis of the results, the water meter confirmed that the error of minimum flow rate which will use long becomes larger more in the direction of minus.

Analysis of Microclimate and Conservation Environment of the Stone Buddha and Shrine in Unjusa Temple, Hwasun, Korea (화순 운주사 석조불감의 보존환경 및 미기상 분석)

  • Park, Sung-Mi;Lee, Chan-Hee;Lee, Myeong-Seong;Kim, Sa-Dug
    • Economic and Environmental Geology
    • /
    • v.42 no.1
    • /
    • pp.73-84
    • /
    • 2009
  • The stone Buddha and Shrine of Unjusa temple (Korean Treasure No. 797) at Hwasun formed in Koryo Dynasty is unique style which faces each other the back parts of south and north within the stone Shrine. The stone Buddha and Shrine is highly evaluated in historical, artistic and academic respects. But, the stone properties have been exposed in the open system various aspects of degradations weathered for a long time without specific protective facilities. To inquire into relative deterioration and environmental factor, air temperature and relative humidity of the stone Buddha and Shrine were monitored for a year of the indoor and outdoor, respectively. As a result, the temperature shows increase and decrease according to the seasons in the tendency to clear. While the relative humidity is high to keep all four seasons. Highly relative humidity environment induces dew condensation on the interior of stone Buddha and Shrine. The dew condensation is recorded at the spring, summer and winter season. The summer season is double the total of spring and winter season. In the case of summer, dew condensation is long time continued due to high temperature and relative humidity that is kept by more than nearly 100%. There is progress towards chemical weathering throughout dissolve rock properties and alteration on the rock surface. In the case of winter, dew condensation is not kept for a long time as summer. In the winter, which showing a below zero may add physical weathering throughout moisture that happen by dew condensation to repeat freezing and thawing. Therefore, the reduction plan of the relative humidity effect on dew condensation should be prepared.

A Study on Under-registration of 13mm Water Meters (가정용 13mm 수도계량기 미감지율 조사연구)

  • Ahn, Jae-Chan;Ha, Sung-Ho;Jeong, Pan-Sig;Choi, Jeong-Sub;Koo, Ja-Yong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.4
    • /
    • pp.506-514
    • /
    • 2005
  • Unaccounted-for water subtracting water sold from produced water includes leakage, under-registration, unauthorized use, etc. To improve accounted-for water ratio, firstly, it should be attempted to accurately identify where unaccounted-for water is, and then it must to be reduced. Under-registration of meter is caused by allowable tolerance of meter, improper size of meter installed, gradient installation, etc. Under-registered water of meters has ever been the second large amount of unaccounted-for water next to leakage, but still is not estimated exactly. In this study, the estimated value as under-registered water was obtained by using the selected-area modeling program. As a result, the under-registered water ratio of 13mm meters was approximately 1.23%. Those of meters according to ages 1, 3, and, 5 years old were 1.46% 2.77% and, 2.26%, respectively but that of 7 years old meters showed over-registration of 1.59%.

Investigation on Under-registration of 20 mm to 50 mm Water Meters (20~50mm 수도계량기 미감지율 조사분석)

  • Ahn, Jae-Chan;Ha, Sung-Ho;Park, Tae-Jun;Kim, Sug-Jung;Koo, Ja-Yong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.5
    • /
    • pp.582-594
    • /
    • 2005
  • The under-registration of water meters of 20mm to 50mm in diameter, installed in Seoul city, was estimated by random sample method. The sample sites and sampled meters were selected for the measurements of flow rates and accuracy tests, respectively. The measurement of flow rates was conducted for 20mm to 50mm meters for about 20 days per site using flow meters and data loggers. The under-registration of 20mm, 25mm, 32mm, 40mm, and 50mm meters was observed as 3.96%, 1.10%, 2.47%, 4.04%, and 1.04%, respectively. The under-registration might be increased more or less as malfunction and failure of the sampled meters was not considered. In this study the under-registration of 20mm, 25mm, 32mm, 40mm, and 50mm meters was accurately estimated on the basis of the investigation data. The estimation of under-registration of water meters, one of the basic figures in water industry, contributed to accurate calculation of leakage, water supply and consumption, and strategic planning to reduce the unaccounted-for water.

Dual-Mode Reference-less Clock Data Recovery Algorithm (이중 모드의 기준 클록을 사용하지 않는 클록 데이터 복원 회로 알고리즘)

  • Kwon, Ki-Won;Jin, Ja-Hoon;Chun, Jung-Hoon
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.5
    • /
    • pp.77-86
    • /
    • 2016
  • This paper describes a dual-mode reference-less CDR(Clock Data Recovery) operating at full / half-rate and its operation algorithm. Proposed reference-less CDR consists of a frequency detector, a phase detector, a charge pump, a loop filter, a voltage controlled oscillator, and a digital block. The frequency and phase detectors operate at both full / half-rate for dual-mode operation and especially the frequency detector is capable of detecting the difference between data rate and clock frequency in the dead zone of general frequency detectors. Dual-mode reference-less CDR with the proposed algorithm can recover the data and clock within 1.2-1.3 us and operates reliably at both full-rate (2.7 Gb/s) and half-rate (5.4 Gb/s) with 0.5-UI input jitter.

Effects of Non-ionic Surfactant Tween 80 on the in vitro Gas Production, Dry Matter Digestibility, Enzyme Activity and Microbial Growth Rate by Rumen Mixed Microorganisms (비이온성 계면활성제 Tween 80의 첨가가 반추위 혼합 미생물에 의한 in vitro 가스발생량, 건물소화율, 효소활력 및 미생물 성장율에 미치는 영향)

  • Lee, Shin-Ja;Kim, Wan-Young;Moon, Yea-Hwang;Kim, Hyeon-Shup;Kim, Kyoung-Hoon;Ha, Jong-Kyu;Lee, Sung-Sil
    • Journal of Life Science
    • /
    • v.17 no.12
    • /
    • pp.1660-1668
    • /
    • 2007
  • The non-ionic surfactant (NIS) Tween 80 was evaluated for its ability to influence invitro cumulative gas production, dry matter digestibility, cellulolytic enzyme activities, anaerobic microbial growth rates, and adhesion to substrates by mixed rumen microorganisms on rice straw, alfalfa hay, cellulose filter paper and tall fescue hay. The addition of NIS Tween 80 at a level of 0.05% increased significantly (P<0.05) in vitro DM digestibility, cumulative gas production, microbial growth rate and cellulolytic enzyme activity from all of substrates used in this study. In vitro cumulative gas production from the NIS-treated substrates; rice straw, alfalfa hay, filter paper and tall fescue hay was significantly (P<0.05) improved by 274.8, 235.2, 231.1 and 719.5% compared with the control, when substrates were incubated for 48 hr in vitro. The addition of 0.05% NIS Tween 80 to cultures growing on alfalfa hay resulted in a significant increase in CMCase (38.1%), xylanase (121.4%), Avicelase (not changed) and amylase (38.2%) activities after 36 h incubation. These results indicated that the addition of 0.05% Tween 80 could greatly stimulate the release of some kinds of cellulolytic enzymes without decreasing cell growth rate in contrast to trends reported with aerobic microorganism. Our SEM observation showed that NIS Tween. 80 did not influence the microbial adhesion to substrates used in the study. Present data clearly show that improved gas production, DM digestibility and cellulolytic enzyme activity by Tween 80 is not due to increased bacterial adhesion on the substrates.

A Study on the Improvement of Fire Evacuation Scenario Using Delphi Technique -Focus on The Mobile Application and psychology- (델파이 기법을 활용한 화재피난 시나리오 개선 연구- 모바일 어플리케이션과 재실자 심리를 중심으로 -)

  • Lee, Sang ki;Kim, Sung Hyun
    • Journal of Service Research and Studies
    • /
    • v.12 no.2
    • /
    • pp.23-37
    • /
    • 2022
  • Based on the service scenario proposed by the existing Kim Tae-wan (2018) who can safely evacuate inmates with the help of a mobile application linked to a fire detection system in the event of a fire, the final purpose of this study is to develop the scenario by incorporating more realistic scenarios with mobile stimuli that can help them escape or act through the Delph In addition, to make the scenarios produced more realistic considering the structure and copper lines of a typical building, expert scenario verification and Delphi technique were applied to exclude unnecessary or impractical aspects of the existing scenarios. The results of the second Delphi survey showed that the primary psychology that could be seen at the time of the fire alarm were doubts, safety concerns and alarm, and the results of the second Delphi survey were analyzed, and the satisfaction of the content adequacy (CVR), convergence, and consensus was derived. Finally, this was applied to create a scenario in which a mobile application was assisted to evacuate the fire response phase. This study will allow the use of methods to increase the evacuation rate of those who are in the event of a fire.

The Characteristics and Fates of Pulmonary Tuberculosis Patients Seen at Medical Department of A Medium Sized General Hospital (부산에 한 중형 종합 병원 내과에서의 폐결핵 환자의 양상과 귀결)

  • Kim, Young-Hyo;Park, Ki-Chan;Bae, Seong;Lee, Sang-Hun;Chun, Myung-Ho;Lee, Sang-Ki;Jun, Kwang-Su;Lee, Chan-Se
    • Tuberculosis and Respiratory Diseases
    • /
    • v.39 no.5
    • /
    • pp.417-424
    • /
    • 1992
  • Background: There were many reports about the clinical aspect and outcomes of pulmonary tuberculosis in health center but few in a medium sized general hospital. The purposes of this study were to find any characteristic differencies in the patients and the general outcomes of the treatments and also to give some suggestive points for the insurance policy making. Methods: We made a retrograde analysis of the medical records of 1981 patients (male 992 female 1,059) who attended our clinics of the 4th internal department, Daedong general hospital during two years from January 1989 to December 1990. Result: 1) Of 1981 patients, 96 were diagnosed as pulmonary tuberculosis taking relatively large proportion in the prevalence. The ratio of prevalence between male and female was 7.81% to 2.27%. The 61.46% were the first diagnosis & initial treatment cases and the remaining 38.54% were the retreatment cases with no statistical significance between sex. 2) The most prevalent age group was between 21~40 years old and the prevalence rate was 45.45% of male and 76.76% of female. The lowest age group in male patient was above 61 showed 3.03%, and there was no female patients above age 60 years old. This phenomena could be thought as the negligence for the treatment of pulmonary tuberculosis in the old age groups rather than true tuberculosis prevalence and it could be proved by the higher rates towards old age groups in the national tuberculosis prevalence survey. 3) There were 57.07% of the minimal case, 48.96% of the moderate, 18.75% of the far advanced. The sputum examination showed 37.07% were culture positive, 46.88% were the negative, and 15.63% of the patients had no stutum examination. Moreover, uncoperatives among the far advanced cases were notable showing 22.22% of the stutum examination, where 16.13% in the minimal cases. The stutum positive rate among the initial treatment cases were 41.07% and 55.00% for the retreatment cases. The sputum no examination rates were 17.86% and 12.50% respectively. 4) The classfication of the mode of disease onset showed 68.75% with gradual onset, 9.38% hemoptic, 3.13% acute pneumonic and 18.75% was found through the radiologic examination in various occasions. 5) The percentages of patients who continued their treatment for more than 8 month were 35.71% (for initial treatment), 25.00% (for retrement), 16.13% (for the minimal), 27.78% (for the far advanced). 6) The group of patients who were treated more than 8 months showed the negative conversion rate of 80% on sputum and marked improvement on chest x-ray in 56.67%. However, in far advanced or retreatment cases, the rate of negative conversion on sputum and the rate of improvement on chest x-ray were low being 60% and 20% for the former and 60% and 10% for the latter, each respectively. Conclusion: It would be strongly emphasized that the improvement of National medical insurance system and social welfare system in Korea must be definite to improve overall treatment and control of tuberculosis diseases as well as physician's devotious National tuberculosis control policy.

  • PDF