• Title/Summary/Keyword: Water Leakage Method

Search Result 266, Processing Time 0.022 seconds

Back Tracing Calculation Method for the Leakage Detection in Water Distribution System (상수관망에서 누수탐지를 위한 역추적계산법)

  • Kwon, Hyuk Jae
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.5
    • /
    • pp.611-619
    • /
    • 2013
  • In this study, Back Tracing Calculation Method was developed to determine the leakage location and leakage amount. Previously developed determination method of monitoring location and newly developed Back Tracing Calculation Method were applied to the sample pipe network and real size pilot plant. After leakage was assumed in the pilot plant, leakage location and leakage amount could be traced by Back Tracing Calculation Method. From the results, it was found that Back Tracing Calculation Method can be applied for the leakage detection in water distribution system. Furthermore, this method can be applied for the pressure management or leakage detection as a pressure control method in water distribution system.

Estimation method of natural rate of rise of leakage in water distribution system (배급수관망에서의 누수복원량 산정방법)

  • Jin, Saemmul;Kim, Kyoungpil;Koo, Jayong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.33 no.4
    • /
    • pp.299-309
    • /
    • 2019
  • Waterworks facilities inevitably experience some amount of leakage even if there is a lot of investment or state-of-the-art technology that is applied such as DMA(District Metered Area) system construction, leakage detection, repair, pipe rehabilitation, etc. The primary reason is the leakage is naturally restored over time. In the UK, this restoration characteristic is defined as NRR(Natural rate of rise of leakage) and used to decision making for prioritizing active leakage control of DMAs. However, this restoration characteristic is well recognized, but researches on NRR in the water distribution system are insufficient in Korea. In this study, the estimation method of NRR was developed suitable for applicating in Korea considering of SCADA data, water infrastructure, and water usage patterns by modification of the UK's NRR method. The proposed method was applied to 9 DMAs and verified it's applicability by comparing with the other water loss performance indicators. It is expected that the proposed method can be used to support decision making for sustainable NRW(Nor-revenue water) management in the water distribution system.

A Study in the Water Leakage Prevention around the Windows with the Stone Materials in the Apartment House (공동주택 외부 석재마감에 따른 창호주위 누수방지에 관한 연구)

  • Yun, Hong-Jung;Cho, Tae-Jea
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2006.11a
    • /
    • pp.117-121
    • /
    • 2006
  • This study intends to suggest the effective methods for water leakage prevention around the windows in stone works to up-grade the outdoor public space that has been taken much portion of apartment housing trends. The subjects of the study was selected among the domestic subcontractors of stone works. There are four methods for water leakage prevention around the windows; Firstly, the painting water-proof method after the masonry. Secondly, the urethane water-proof method after galvanizing panels on the gap. Thirdly, the separation method between stone and substructure and the last one is water-proof method that they put some water-proof screen between stone and substructure with the EPDM sheets. According to the analysis of the water-proof effects, constructability and planning, we could approach to conclusion that the most influent items to the water-leakage are the filling material's deformation, the state of oxygenation and deterioration of work skill. Among the water-proof methods in construction the EPDM sheet is most excellent water-proof method to meet the technical conditions. However, we have to apply it to stone works as a water-proof method for the decrease of the leakage defects after standardizing the materials, test and construction skill because there are many work skills according the subcontractors.

  • PDF

A Study on Setting Methods of Economic Level of Leakage in Water Pipe Networks (상수도 관망에서의 경제적인 누수관리목표 산정 방안 연구)

  • Hwang, Jinsoo;Choi, Taeho;Lee, Doojin;Koo, Jayong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.3
    • /
    • pp.237-248
    • /
    • 2017
  • The estimation method of economical leakage management target utilized upon planning business for improvement of revenue water ratio in South Korea is presented and applicability of methods developed in this study is assessed through application on site. With a consideration of revenue water ratio in application target area, estimation method of long-term economical leakage management target is applied. Three leakage reduction methods such as replacement of residual aged pipe, leakage investigation and restoration and water pressure management are applied with a consideration of characteristics of site. Due to difficulty of obtaining data, analysis of cost/benefit by leakage reduction methods is performed by applying method of leakages estimation equation among statistical methods. As a result of application, revenue water ratio corresponding to long-term economical leakage management target is 91.6 %.

Search Method for Optimal Valve Setting and Location to Reduce Leakage in Water Distribution Networks (배수관망시스템 누수저감을 위한 최적 밸브제어 및 위치탐색 모델 개발)

  • Choi, Jong Sub;Kala, Vairavamoorthy;Ahn, Hyo Won
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.1
    • /
    • pp.149-157
    • /
    • 2008
  • The reduction of leakage is a major issue of the South Korea water industry. The inclusion of pressure dependent leakage terms in network analysis allows the application of optimization techniques to identify the most effective means of reducing water leakage in distribution networks. This paper proposes a method to find optimal setting and location of control valve for reducing leakage efficiently. The proposed search method differs from previous methods for addressing optimal valve location problem and improves the GA simulation time with guaranteeing for getting the global optimal solution. The strength of this method has been demonstrated by means of case studies. This allows the procedure of optimization to be more robust and computational efficient.

Leakage experiments and applications of leakage detection algorithm in the pilot plant of water distribution system (상수관망 파일럿플랜트에서의 누수실험 및 누수탐지 알고리즘의 적용)

  • Kwon, Hyuk Jae
    • Journal of Korea Water Resources Association
    • /
    • v.50 no.9
    • /
    • pp.609-616
    • /
    • 2017
  • In this study, algorithm for the selecting the optimum monitoring location and leakage detection algorithm based on back tracing calculation method were developed and verified by the experiments in pilot plant of water distribution system. First of all, optimum monitoring locations were selected and pressure changes were measured due to artificial leakage by pressure gauges in pilot plant. Simulations of leakage detection was performed for the verification of back tracing calculation method as a leakage detection method. From the results, it was found that leakage locations and leakage amount were exactly estimated. Various leakage amount from $0.0005m^3/s$ to $0.0018m^3/s$ were reproduced and leakage location was detected by back tracing calculation method. It was verified that back tracing calculation method as a leakage detection method is effective.

Leakage Control and Application Using the Pressure Reducing Valve (압력제어밸브를 통한 누수량의 추정과 활용)

  • Kim, Shin-Geol;Kim, Youn-Hwan;Kim, Kyoung-Pil;Koo, Ja-Yong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.2
    • /
    • pp.197-206
    • /
    • 2006
  • The leakage in the water distribution system means both the loss of money and water resource. To minimize the leakage, we introduced the pressure control method using the pressure reducing valve and pump schedule. For the pressure control, the total leakage is needed to divide into each node. In this study, EPANET 2.0 was used to simulate the water networks in two selected blocks after the total leakage was distributed with each node by four ways. The leakage was allocated into each node as water measured by meter, water pressure, water faucets and Lpcd and simulated by EPANET 2.0. Regardless of the leakage distribution ways, there was no significant difference between the measured water and the estimated water pressure. Thus, the leakage distribution way using water pressures estimated by simulation could be recommended. The scenarios controlling the pressure reducing valve and pump were made in two blocks(A and B). $86,713m^3/year$ leakage in the A block and $11,442m^3/year$ in the B block could be reduced as controlling the pressure reducing valve and pump schedule. It was shown that the fifty million won a year can be saved in the A block and 6.8 million won in the B block.

A Study on Long-Term Seepage Behaviour of Fill Dam by the Monitoring Data Analysis (계측자료 분석에 의한 필댐의 장기 침투거동 연구)

  • Chung, Kyujung;Lee, Song
    • Journal of the Korean GEO-environmental Society
    • /
    • v.11 no.9
    • /
    • pp.15-25
    • /
    • 2010
  • The main objective of this study was to offer informations about long-term seepage behavioral characteristics and to find a leakage safety management method for Juam Dam and Imha Dam, a central cored rockfill dams in Korea by the evaluating the automatically monitored leakage data. In the water leakage monitoring of fill dam, the generation of abnormal water leakage is difficult to directly detect due to the effect of outside factors such as the component of rainfall inherent in the observation value. Therefore, conventionally estimation methods of water leakage quantity were applied by multiple regression analysis considering reservoir water level, rainfall, etc.. However, the estimated error of rainfall component is relatively big in these method. This paper identifies the seepage characteristic of each dams which is not directly affected by rainfall through the hydrograph separation analysis and 3 dimensional analytical method, and thinks a leakage management method. It was noticed that two dams had site specific seepage behaviour features and were in stable state with the decreasing leakage quantity. It was also found that hydrograph separation method might be applicable to leakage safety management method.

Analysis of Slot Leakage Reactance of Submersible Motor with Closed Slots during Starting Transient Operation

  • Bao, Xiaohua;Di, Chong;Fang, Yong
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.1
    • /
    • pp.135-142
    • /
    • 2016
  • Generally, closed slots are adopted to reduce the water friction loss in both the stator and the rotor of water filling submersible motor due to the special environment of operation. One of the obvious differences between the traditional induction motors and water filling submersible motors is that the submersible motors only need relatively smaller starting torque. This paper aims to analyze the slot leakage reactance of water filling submersible motor during starting transient operation. An improved analytical method which considered the magnetic saturation of the slot bridge and the skin effect of rotor bars is proposed. The slot permeance factor which has a direct impact on the slot leakage reactance is calculated. Then finite element models with different stator slot types are constructed and search coils are introduced to measure the slot flux linkage. Moreover, the starting performances of the models with two typical stator slots are compared and the flux leakage characteristics are obtained. Finally, the results obtained by finite element method are very close to the results obtained by analytical method.

Transient Analysis and Experiment Considering Unsteady Friction and Leakage in a Pipeline System (단일관망에서 누수효과를 고려한 천이류 분석 및 실험)

  • Lee, Mi-hyun;Song, Yong-sok;Kim, Sang-hyun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.2
    • /
    • pp.207-214
    • /
    • 2006
  • The current paper focuses the analysis of leakage detection in water pipeline systems by means of the transient method. In order to obtain essential data for evaluation the existing methodology, an extensive experimental process has been carried out in a single pipeline system, Several experimental tests were performed with and without a leakage in the system. Using the unsteady friction and improved unsteady friction factors gives reasonable match between the computed and measured results on the condition of the flow situations presented in the paper. The transient method attempts to estimate the leakage in water pipelines using observed pressure data collected during transient events on the system.