• Title/Summary/Keyword: Waste Removal

Search Result 1,016, Processing Time 0.024 seconds

The Removal Characteristics of Cs$^{+}$ and Co$^{++}$ from Aqueous Wastes by Ultrafiltration in Combination with Chemical Treatment Techniques(II) (화학처리와 한외여과막의 결합공정에 의한 Cs 및 Co의 제거특성 (II))

  • 이근우;정경환;김길청;김준형
    • Journal of Energy Engineering
    • /
    • v.5 no.1
    • /
    • pp.56-64
    • /
    • 1996
  • The objective of this investigation is to establish the rejection characteristics of caesium and cobalt from radioactive liquid waste by chemical/ultrafiltration process. An extensive experimental investigation was conducted with inactive caesium and cobalt ions, utilizing ultrafiltration stirred cell. Caesium and cobalt could be effectively removed from waste solution using copper ferrocyanide and polyarcylic acid(PAA). The rejection dependence of the caesium was found to be a function of caesiun to potassium copper ferrocyanide feed molar ratio. The binding behavior of caesium on K$_2$Cu$_3$(Fe(CN)$\sub$6/)$_2$, particles was explained in terms of a Langmuir adsorption isotherm. When Cs/K$_2$Cu$_3$(Fe(CN)$\sub$6/)$_2$molar ratio was 1.5, the removal of caesium was the most efficient. The rejection efficiency of cobalt is dependent upon various parameters such as pH, cobalt concentration and PAA concentration. The rejection behavior of cobalt was explained in term of a equilibrium model taking into account the reaction between the ligand group, the proton and the cobalt ion. At the conditions of PAA/Co ratio of 2 and pH of 5.6, the removal of cobalt was over 90%. Also, the effect of chemical addition sequence for the simultaneously removal of caesiun and cobalt was discussed.

  • PDF

Ion Adsorption Characteristics of IRN-150 Mixed Resin and Removal Behavior of $^{14}C$ Radionuclide from Spent Resin by Stripping Solutions (IRN-150 혼상수지의 이온 흡착특성 및 폐수지로부터 탈착용액을 이용한 $^{14}C$ 핵종의 제거 특성)

  • Yang, Ho-Yeon;Won, Jang-Sik;Choi, Young-Ku;Park, Geun-Il;Kim, In-Tae;Kim, Kwang-Wook;Song, Kee-Chan;Park, Hwan-Seo
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.4 no.4
    • /
    • pp.373-384
    • /
    • 2006
  • Spent ion-exchanged resin generated from various purification systems in CANDU reactor was contaminated with high activity of $^{14}C$ radionuclide. This paper describes the results of fundamental study to develop the applicable technology for the treatment of this spent resin. Based on the adsorption capacity of inactive $HCO_3$ ion and other anions on IRN-150 mixed resin, the removal characteristics of $HCO_3$ ion adsorbed on to IRN-150 by various stripping solutions were evaluated. Maximum adsorption amount of the $HCO_3$ ion onto IRN-150 raw resin was about 11 mg-C/g-resin which agrees with the theoretical adsorption amount of this resin. Adsorption affinity of various anions such as $CS,\;CO,\;Na\;NH_4$ was analyzed in single and multi-component systems. From the results of removal characteristics of the $HCO_3$ ion adsorbed on IRN-150 by various stripping solutions, $NH_4H_2PO_4$ stripping solution is more effective than $NaNO_3,\;Na_3PO_3$ solutions for the complete removal of $^{14}C$ radionuclide from the IRN-150 spent resin.

  • PDF

Removal of Microcystis aeruginosa using polyethylenimine-coated alginate/waste biomass composite biosorbent (양이온성 고분자(polyethylenimine)가 코팅된 알지네이트/폐바이오매스 복합 흡착소재를 사용한 유해 미세조류 Microcystis aeruginosa의 제거)

  • Kim, Hoseon;Byun, Jongwoong;Choi, In Tae;Park, Yun Hwan;Kim, Sok;Choi, Yoon-E
    • Korean Journal of Environmental Biology
    • /
    • v.37 no.4
    • /
    • pp.741-748
    • /
    • 2019
  • As the occurrence of harmful algal blooms (HABs) have become severe in precious water resources, the development of efficient harmful algae treatment methods is considering as an important environmental issue for sustainable conservation of water resources. To treat HABs in water resources, various conventional physical and chemical methods have been utilized and showed treatment efficiency, However, these methods can lead to discharging of cyanotoxins into the water bodies by chemical or physical algal cell lysis or destruction. Thus, to overcome this limitation, the development of safe HABs treatment methods is required. In the present study, adsorption technology was investigated for the removal of harmful algal species, Microcystis aeruginosa from aqueous phases. Industrial waste biomass, Corynebacterium glutamicum biomass was valorized as biosorbent (PEI-modified alginate/biomass composite fiber; PEI-AlgBF) for M. aeruginosa through immobilization with alginate matrix and cationic polymer (polyethylenimine; PEI) coating. The functional groups characteristic of PEI-Alg was determined using FT-IR analysis. By adsorption process used PEI-AlgBF, 52 and 67% of M. aeruginosa could be removed under the initial density of M. aeruginosa 200×104 cells mL-1 and 50×104 cells mL-1, respectively. As the increasing surface area of PEI-AlgBF, the removal efficiency was increased. In addition, we could find that adsorptive removal of M. aeruginosa has occurred without any M. aeruginosa cell lysis and destruction.

Removal of $NH_3$ Gas by a Biofilter Packed with Bio-Carrier Composed of Waste Polyurethane and Wormcast (폐 폴리우레탄과 분변토 미생물담체가 충전된 Biofilter에서의 $NH_3$ 가스의 제거)

  • Lim, Joung-Soo;Lee, Eun-Young
    • Clean Technology
    • /
    • v.13 no.2
    • /
    • pp.122-126
    • /
    • 2007
  • When ammonia ($NH_3$) gas was supplied to a biofilter packed with bio-carrier made of waste polyurthane and worm cast. No odor gases were detected at the outlet of the biofilter when $NH_3$ gas was supplied to the biofilter at the space velocity(SV) of $50\;h^{-1}$ until the inlet $NH_3$ concentration increased to $4\;{\sim}\;454\;ppmv$. The gradual inlet $NH_3$ concentration was set and the removal efficiency of $NH_3$ gas was measured at each condition, while the SV of $NH_3$ increased step by step from 100 to $400\;h^{-1}$. The maximum possible inlet $NH_3$ loading was $11.38\;g-NH_3{\cdot}m^{-3}{\cdot}h^{-1}$ and $34.42\;g-NH_3{\cdot}m^{-3}{\cdot}h^{-1}$ while maintaining the removal efficiency of 100% when the SV was $50\;h^{-1}$ and $100 \;h^{-1}$, respectively. The maximum $NH_3$ loading was $71.28 \;g-NH_3{\cdot}m^{-3}{\cdot}h^{-1}$ with the $NH_3$ removal efficiency of 99.85% at SV $300\;h^{-1}$.

  • PDF

Studies on the Nutrient removal potential of selected aquatic plants in the pig waste water. (축산폐수(畜産廢水)의 오염물질제거(汚染物質除去)를 위(爲)한 수초선발이용연구(水草選拔利用硏究))

  • Kim, Bok-Young;Kim, Kyu-Sik;Park, Young-Dae
    • Korean Journal of Environmental Agriculture
    • /
    • v.7 no.2
    • /
    • pp.111-116
    • /
    • 1988
  • The aquatic plants were cultivated in pots containing pig waste water, adjusted to three levels of $NH_4-N$ concentration 50, 100 and 200ppm. The aquatic plants were Eichhornia crassipes solms-laub, Monochoria korsakowii Regel et maack, Zizania caduciflora, Typha orientalis, Acorus asiaticus, Cyperus exaltaus, Colocasia antiquorum var. Yield, content and amount of nitrogen and phosphorus absorped by plants, and growth status were investigated. The results obtained are as follows. 1. The content and removal amount of nitrogen and phosphrus by plants were the highest in Eichhornia crassipes solms-laub. 2. Yield of dry matter in plants in 100ppm $NH_4-N$ was in the order of Eichhornia crassipes solms-laub>Zizania caduciflora>Typha orientalis>Monochoria korsakowii Regel et maack>Acorus asiaticus. 3. The removal amount of nitrogen by plants in the 100ppm $NH_4-N$ was in the order of Eichhornia crassipes solms-laub>Zizania caduciflora>Monochoria korsakowii Regel et maack>Typha orientalis>Acorus asiaticus>Colocasia antiquorum var>Cyperus exaltatus. Removal amount of phosphorus was in the order of Eichhornia cras sipes solms-laub>Monochoria korsakowii Regel et maack>Zizania caducilora>Typha orientalis>Acorus asiaticus> Cyperus exaltatus>Colocasia antiquorum var. 4. Concentration causing growth damage was 200ppm of $NH_4-N$ in Eichhornia crassipes solms-laub, Zizania caduciflora and Typha orientalis and 100ppm in Monochoria korsakowii Regel et maack and Acorus asiaticus. 5. Nitrogen content was the highest in leaf and phosphorus content was the highest in float of the water hyacinth. 6. The number of panicles of the water hyacinth increased by 752 pieces and dry matters were about 5,000kg/l0a during one year.

  • PDF

Species Diversity of Chironomid Midge and Evaluation on Removal Capacity of Organic Matter Using a Dominant Species, Chironomus nipponensis in Agroecosystem (농업생태계 깔따구 유충의 다양성 및 우점종 닙폰깔따구를 이용한 유기물 분해능 평가)

  • Sim, Ha-Sik;Park, Byoung-Do;Lee, Young-Bo;Choi, Young-Chol;Kim, Jong-Gil;Park, Hae-Chul
    • Korean Journal of Environmental Biology
    • /
    • v.27 no.1
    • /
    • pp.31-39
    • /
    • 2009
  • To recognize the species composition and community of chironomid midge in agroecosystem and evaluate removal capacity of organic matter using the dominant species among them. Chironomid midge and invertebrate cohabitants were quantitatively collected at 78 representative stations of five habitat types (in arable land during 2004$\sim$2006) A, paddy fields of the large scale arable land; B, paddy fields of the environmental friendly arable land; C, influent of domestic waste water; D, influent of waste water by livestock; E, the irrigation ditch of paddy area. The total sixteen species of chironomid midges at arable land were presented. And also chironomid midges were recognized by five habitat types: eleven species in D, eight in A, seven in E, six in B, and two in C. We confirmed dominant species in each habitat types as followings: Chironomus nipponensis in A, C, and D; Cricotopus sylvestris in E; Tanytarsus seosanensis in B. Water quality and community index were high in E, but low in A, B, C, and D. Comparing with non-treatment, removal activities of organic matter in bottom by C. nipponensis were increased 18% in 90 individuals treatment.

Removal of Cobalt Ion by adsorbing Colloidal Flotation (흡착 교질 포말부선법에 의한 Cobalt Ion의 제거)

  • 정인하;이정원
    • Resources Recycling
    • /
    • v.7 no.3
    • /
    • pp.3-10
    • /
    • 1998
  • Simulated waste liquid containing 50 ppm cobalt ion was treated by adsorbing colloidal flotation using Fe(III) or Al(IlI) as flocclant and a sodium lamyl sulfate as a collector. Parameters such as pH, surfactant concentration, Fe(III) or Al(III) concentration, gas flow rate, etc., W앙e considered. The flotation with Fe(III) showed 99.8% removal efficiency of cohalt on the conditions of initial cobalt ion concentration 50 ppm, pH 9.5, gas flow rate 70 ml/min, and flotation time 30 min. When the waste solution, was treated with 35% $H_2O_2$ prior to adsorbing colloidal flotation, the optimal pH for removing cobalt shifted m to weak alkaline range and flotation could be applied in wider range of pH as compared to non-use of $H_2O_2$. Additional use of 20 ppm Al(III) after precipitation of 50 ppm Co(II) with 50 ppm Fe(III) made the optimal pH range for preferable flotation w wider. Foreign ions such as, $NO_3^-$, $SO_4^{2-}$, $Na^+$, $Ca^{2+}$ were adopted and their effects were observed. Of which sulfate ion was f found to be detrimental to removal of cob퍼t ion by flotation. Coprecipitation of Co ion with Fe(III) and Al(III) resulted in b better removal efficiency of cobalt IOn 피 the presence of sulfate ion.

  • PDF

Removal of Cobalt Ions by Precipitate Foam Flotation (침전 포말부선법에 의한 Cobalt Ion의 제거)

  • 정인하;이정원
    • Resources Recycling
    • /
    • v.7 no.3
    • /
    • pp.11-16
    • /
    • 1998
  • Simulated waste liquid containing 50 ppm cobalt ion was t$\xi$sted by precipitate flotation using a sodium lauryl sulfate as a c collector. The effects of initial cobalt ion concentration, pH, surfactant concentration, flotation time, gas flow rate and foreign i ions on removal efficiency of cobalt ion were studied. Pretreatment of the waste liquid with 35% $H_2O_2$, prior to precipitate f flotation made shin of optimal flotation pH from the strong alkalinity to weak alkaline range and made a favorable flotation of c cobalt ion in wide range of pH. For the result of this experiment, 99.8% removal efficiency was obtained on the conditions of initial coball ion concentration 50 ppm, pH 9.5 gas flow rate 70 mllmin, flotation time 30 min. The simulate ion was fanned t to be the most harmful ion against removal of cobalt by precipitate flotation of the species which were tested The presence of 0.1 M of $SO_4^{2-}$ ion decreased remo,때 $\xi$폐iciency of cobalt to 90% while the cobalt were almost entirely removed in the a absence of sulfate ion.

  • PDF

Evaluation of Hydration Characteristics and NOx-removal Performances of Cement Paste Containing Refined TiO2 Obtained from Waste Sludge (폐수 슬러지에서 정제된 TiO2를 혼입한 시멘트 페이스트의 수화특성 및 질소산화물 제거 성능 평가)

  • Yoon, Hyunno;Seo, Joonho;Kim, Seonhyeok;Bae, Jinho;Kil, Taegeon;Lee, Haeng-Ki
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.41 no.4
    • /
    • pp.357-364
    • /
    • 2021
  • The present study investigated the hydration properties and NOx-removal performances of the cement pastes containing three different types of TiO2. Two commercially available TiO2 (P-25 and NP-400) and refined TiO2 (GST) obtained from waste sludge were incorporated to cement paste at levels of 0, 5, 10, and 20 wt%. Isothermal calorimetry test results indicated that the TiO2 incorporation induced a notable influence on the reaction kinetics of cement paste, showing the highest cumulative heat release in the samples containing P-25, followed by NP-400 and GST. Quantitative X-ray diffractometry as calculated by the Rietveld method identified that the incorporated TiO2 promoted the formation of C-S-H, ultimately leading to the enhancement in the 28 day-compressive strength of cement pastes. As revealed by SEM/EDS analysis, the content of distributed Ti elements on the surface of the samples was in the order of P-25, GST, and NP-400. Regardless, the NOx-removal performance was the highest in the sample containing P-25, followed by NP-400 and GST.

Content characteristics of persistent organic pollutants waste from paint, iron making and steel making process (국내 도료 및 제철·제강산업 발생 폐기물 중 잔류성 유기오염물질류의 함량 특성 -PCDD/DFs, PAHs, PCBs-)

  • Kim, Dong-Un;Kim, Woo-Il;Kang, Young-Yeul;Lee, Dong-Jin;Jeong, Seong-Kyeong;Cho, Yoon-A;Yeon, Jin-Mo;Shin, Sun-Kyoung;Oh, Gil-Jong
    • Analytical Science and Technology
    • /
    • v.24 no.5
    • /
    • pp.395-400
    • /
    • 2011
  • This study has been carried out in order to effectively manage three groups of unregulated hazardous organic substances (PCDD/DFs, PAHs, PCBs) in South Korea. The investigated substances have been analyzed according to the test methods for hazardous substances in specified wastes provided by the National Institute of Environmental Research, Korea. Total contents of the organic compounds have been determined for hazardous wastes from three major industrial categories (paint, iron removal, steelmaking), such as waste organic solvent, waste paint or dust. By investigating the waste samples for 7 PAHs using GC/MSD, Naphthalene has been detected (N.D~1631.33 mg/kg). The highest Naphthalene concentration, which exceeded the korean marine dumping waste standard, was found in waste organic solvents and waste paints. Although a content analysis of 7 PCB isomers has been conducted, none of these compounds was detected. The analysis of PCDD/DFs has revealed that all samples meet the criterion for low POP content defined in the technical guidelines developed under the Basel Convention. The PCDD/DFs content in dust samples deriving from 10 manufacturing processes (billet, bloom) was determined to be in the range of N.D~5.66 ng I-TEQ/g waste.