• Title/Summary/Keyword: WRIST

Search Result 1,162, Processing Time 0.025 seconds

Wheelchair-based New Millennium Health Gymnastics: Muscle Activity and Upper Limbs Coordination by Elbow Exercise Velocity (휠체어 새천년 건강체조의 팔꿈치 운동속도에 따른 상지협응과 근활성도 변화)

  • Lee, Kang-Jin;Kim, Tack-Hoon
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.9 no.2
    • /
    • pp.161-170
    • /
    • 2014
  • PURPOSE: This study concerns the wheelchair-based rehabilitation of elderly people, investigating muscle activity and coordination of upper limbs during wheelchair-based new millennium health gymnastics with varying elbow exercise velocity. METHODS: Twelve elderly people participated in new millennium gymnastics twice per week during 12-weeks. The group was separated into 0.4, 1.0, and 1.6 Hz groups (controlled by the metronome speed). Range of motion was measured by electrogoniometer, electromyography signals used root mean square values. The data application was normalized using reference voluntary contraction (%RVC). Upper limb (wrist and elbow joint) data gathered while standing up after the "falling on hips" was investigated in terms of coordination of angle-angle plots. One-way ANOVA, paired t-test and Scheffe's post hoc comparisons, were used for statistical analyses. RESULTS: There were results taken before and after the experiments. The results demonstrated a significant improvement in the triceps brachii and flexor carpi radialis of the 0.4 Hz group (p<.05). There was significant difference in the triceps brachi of the 1 Hz group. No significant differences were found in all muscles of the 1.6 Hz group. Muscle co-activation indexes of the 0.4 Hz group were larger than the others. The 0.4 Hz graph was turning point synchronized clockwise. The 1 Hz graph was out of phase with the negative slope. The 1.6 Hz graph was turning point synchronized counterclockwise, and uncontrolled factor phase was offset on angle-angle plots. CONCLUSION: It is found that improvement of muscle activity and upper limbs coordination of elderly people using wheelchair-based new millennium gymnastics is optimal with elbow exercise velocity with a frequency of 0.4 Hz.

Properties of Pulse Waveforms by Posture Changes : Standing, Sitting, Supine Posture (측정 자세의 변화에 따른 맥의 변화 특성 : 선 자세, 앉은 자세, 누운 자세)

  • Kown, Sun-Min;Kang, Hee-Jung;Lee, Sang-Hun;Yim, Yun-Kyoung;Lee, Yong-Heum
    • Korean Journal of Acupuncture
    • /
    • v.26 no.4
    • /
    • pp.13-22
    • /
    • 2009
  • Objectives : Informations on pulse diagnosis in literature are based on diagnosing pulse waveforms on supine posture. However, today's pulse waveforms are measured on various postures for the convenience of patients or doctors. For objective measurement, the effect of posture on the pulse waveforms should be considered. The objective of this study was to find posture-related changes in the radial pulse waveforms. Methods : We used an instrument, DMP-3000(DAEYOMEDI Co., Ansan, Korea), measuring radial pulse waveforms noninvasively by tonometric method. 25 male subjects participated in the trial. Before measuring radial pulse waveforms subjects had rest for 5 min. The pulse waveforms were measured on the left wrist. Each subject underwent this course on the supine, sitting, and standing posture. We analyzed pulse waveforms with Height-parameters, Time-parameters, Energy, and Elastic rate. Results : Height-parameters(h1~h5) on the supine posture were bigger than those on the sitting and standing posture. In case of Time-parameters, the parameters making up systolic time decrease in order of on standing, sitting, and supine position. However, systolic time and diastolic time didn't have any changes. Energy of pulse was the biggest on supine posture and Elastic rate on standing posture. Conclusions : In this study we found that posture changes affect radial pulse waveforms. For quantification of the changes, more trials should be done. After analyzing much data we might apply parameters of pulse waveforms changed by posture. Also, we might diagnose special disease with properties of pulse waveforms by posture.

  • PDF

The Free Vascularized Groin Flap for the Reconstruction of Extremity (사지재건을 위한 서혜부 유리피부편 이식술)

  • Hahn, Soo-Bong;Park, Young-Hee;Kang, Ho-Jung
    • Archives of Reconstructive Microsurgery
    • /
    • v.7 no.1
    • /
    • pp.1-9
    • /
    • 1998
  • From January 1985 to February 1997, 96 patients had undergone the free vascularized groin flap on the upper and lower extremities with microsurgical technique at the department of orthopaedic surgery, Yonsei University College of Medicine. The results were as follows: 1. Average age at the time of operation was 24.9 years. and there were 71 men and 25 women and mean follow up was 62.4 months. 2. The lesion site was 82 cases on the lower extremity: foot(40), leg(20), ankle(13), and 14 cases on the upper extremity: forearm(6), elbow(3), hand(3), wrist(2). 3. The anatomical classification of the superficial circumflex iliac artery was as follows: 1) 39.8% of common origin with superficial inferior epigastric artery, 2) 30.1% of isolated origin and absent superficial inferior epigastric artery, 3) 13.3% of separate origin, 4) 16.9% of origin from the deep femoral artery. 4. There was no statistical significance on arterial anastomosis between end to end and end to side, and on venous anastomosis(end to end) between one vein and two veins. 5. The success rate was average 84.4% in 81 of 96 cases. 6. In the 15 failed cases, the additional procedures were performed: 5 cases of free vascularized scapular flap, 6 cases of full thickness skin graft, 2 cases of cross leg flap, 1 case of latissimus dorsi flap, 1 case of split thickness skin graft. In conclusion, the free vascularized groin flap can be considered as the treatment of choice for the reconstruction of the extensive soft tissue injury on the extremities, and show the higher success rate with the experienced surgeon.

  • PDF

The Degree of Musculoskeletal Discomfort of Officers (사무직근로자의 신체부위별 근골격계 증상과 관련요인)

  • Sim, Mi-Jung;Son, In-A;Hong, Sung-Gi
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.9
    • /
    • pp.249-258
    • /
    • 2009
  • The purpose of this study is to identify the factors influencing the musculoskeletal discomfort and the physical region related symptoms. The outcome of the study uses KOSHA Code H-30-2003 which defines possible symptoms into different categories. Symptom I, ll showing the highest occurrence rate in shoulder and neck regions and most of Symptom III, IV come from back region. Analysis of the factors influencing the musculoskeletal discomfort vary in different parts of the body. In the neck region, the discomfort related to rest and the computer keyboard. Gender affects the magnitude of pain in the shoulder region. Wrist pain is related to the chairs being used and back discomfort is influenced by shoulder exercise and the degree of rest taken. Physical fatigue due to work affects all the regions mentioned above. Conclusively, office workers are prone to the musculoskeletal discomfort due to their work environment. To alleviate this problem, the workers need to be educated with proper long-term musculoskeletal related health programs and exercise program containing various stretching methods. In addition, the effort to improve the variables in this study would help to reduce the rate of musculoskeletal discomfort.

Intra-Body Communication System for Bio Sensors (생체센서를 위한 인체통신시스템)

  • Jung, Jae-Wook;Kang, Jung-Mo;Kim, Myung-Sik;Oh, Woo-Jin
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.9
    • /
    • pp.1749-1754
    • /
    • 2007
  • In this paper, we propose a new Intra-body communication system for bio-sensor which is one of applications in PAN(Personal Area Network) using body channel. The communication systems for bio-sensor network usually transmits a lot of data acquired in sensor to the receiver in wrist or waist. So we deign the intra-body modem with high data rate, low power, and small size which are achieved by baseband communication techniques. It is noted that the baseband transmission does not requires any analog IF and RF frontends, and can be operated in lower frequency than bandpass transmission. The proposed modem operates at 10MHz band according to the characteristics of intra-body channel, and shows the capability of 5Mbps data rate at distance of 20cm, with $BER=10^{-5}$. In addition, we implement the modem within $2{\times}2cm$ area.

A Study of Simple Sleep Apnea Predictive Device Using SpO2 and Acceleration Sensor

  • Woo, Seong-In;Lee, Merry;Yeom, Hojun
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.11 no.4
    • /
    • pp.71-75
    • /
    • 2019
  • Sleep apnea is a disease that causes various complications, and the polysomnography is expensive and difficult to measure. The purpose of this study is to develop an unrestricted wearable monitoring system so that patients can be examined in a familiar environment. We used a method to detect sleep apnea events and to determine sleep satisfaction by non-constrained method using SpO2 measurement sensor and 3-axis acceleration sensor. Heart rate and SpO2 were measured at the finger using max30100. After acquiring the SpO2 data of the user in real time, the apnea measurement algorithm was used to transmit the number of apnea events of the user to the mobile phone using Bluetooth (HC-06) on the wrist. Using the three-axis acceleration sensor (mpu6050) attached to the upper body, the number of times of tossing and turning during sleep was measured. Based on this data, this algorithm evaluates the patient's tossing and turning during sleep and transmits the data to the mobile phone via Bluetooth. The power source used 9 volts battery to operate Arduino UNO and sensors for portability and stability, and the data received from each sensor can be used to check the various degree between sleep apnea and sleep tossing and turning on the mobile phone. Through thisstudy, we have developed a wearable sleep apnea measurement system that can be easily used at home for the problem of low sleep efficiency of sleep apnea patients.

Reliable Measurement and Analysis System for Ubiquitous Healthcare (고신뢰 유비쿼터스 헬스케어 데이터 측정 및 분석 시스템)

  • Jung, Sang-Joong;Seo, Yong-Su;Kim, Jong-Jin;Chung, Wan-Young
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.05a
    • /
    • pp.293-297
    • /
    • 2009
  • This paper describes a real-time reliable measurement and analysis system for ubiquitous healthcare based on IEEE802.15.4 standard. In order to obtain and monitor physiological body signals continuously, wearable pulse oximeter is designed in wrist that could used to measure oxygen saturation of a patient unobtrusively. The measured data was transferred to a central PC or server by using wireless sensor nodes via a wireless sensor network for storage and analysis purposes. LabVIEW server program was designed to monitor and process the measured photoplethysmogram(PPG) to accelerated plethysmogram(APG) by appling second order derivatives in server PC. These experimental results demonstrate that APG can precisely describe the features of an individual's PPG and be used as estimation of vascular elasticity for blood circulation.

  • PDF

Study on the wetsuit manufacturing status in Korea and future research task (국내 습식 잠수복 생산 업체의 생산실태 조사 및 향후 연구과제)

  • Shin, Hyun-Suk;Choi, Inyoung
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.23 no.3
    • /
    • pp.99-108
    • /
    • 2021
  • The present study examines the overall manufacturing status of local wetsuit makers, problems in the manufacturing process, and future research tasks. The study revealed that most manufacturers use neoprene fabric of varying thickness, depending on the body part. Normally, 3 mm-thick fabric is utilized for high-activity body parts and 5 mm-thick fabric is used for high-activity areas requiring thermal insulation. In terms of the manufacturing method, the tools and manufacturing processes used by companies were found to be similar. However, because of the nature of wetsuits requiring a more complicated manufacturing method than that of general clothing, there were some differences in the manufacturing method processes from company to company, such as bonding and ease treatments. According to wetsuit manufacturers, they make incisions in consideration of the body's curvature and the overall shape and design of the wetsuit when developing patterns. For example, most answered that they preform the wrist and ankle parts, where the body's curvature is obvious. On the question regarding the "difficult manufacturing process", the most frequent response was the "bonding" process. Most manufacturers were found to focus on designs that can improve mobility and clothing fit, and commonly experienced low-order quantity as an operational difficulty. As for the question on the wetsuit-related technology needed in the future, the "development of various designs" was the most frequent answer, followed by the "development of lightweight and diverse materials".

A Scheme of Identity Authentication and Anomaly Detection using ECG and Beacon-based Blockchain (ECG와 비콘 기반의 블록체인을 이용한 신원 인증 및 이상징후 탐지 기법)

  • Kim, Kyung-Hee;Lee, Keun-Ho
    • Journal of Internet of Things and Convergence
    • /
    • v.7 no.3
    • /
    • pp.69-74
    • /
    • 2021
  • With the recent development of biometric authentication technology, the user authentication techniques using biometric authentication are increasing. Various problems arised in certification techniques that use various existing methods such as ID/PW. Therefore, recently, a method of improving security by introducing biometric authentication as secondary authentication has been used. In this thesis, proposal of the user authentication system that can detect user identification and anomalies using ECGs that are extremely difficult to falsify through the electrical biometric signals from the heart among various biometric authentication devices is studied. The system detects user anomalies by comparing ECG data received from a wrist-mounted wearable device-type ECG measurement tool with identification and ECG data stored in blockchain form on the database and identifying the user's location through a beacon system.

The Effects of Shoulder Mulligan Taping and Repeated Measurements on Wrist Flexor Muscle Activity and Grip Strength in Forward Head Posture (전방머리자세 대상자에게 어깨관절 멀리건테이핑 적용이 손목굽힘근의 근활성도와 파악력에 미치는 영향)

  • Oh, Kang-o;Park, Su-hyung;Kim, Dong-woo;Baek, Yong-hyeon;Choi, Su-hong
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.24 no.2
    • /
    • pp.1-7
    • /
    • 2018
  • Background: This study was carried out to investigate the effect of mulligan taping group and repeated measurement group on muscle activity and grip strength of adult with forward head posture. Methods: Thirty adults with forward head posture were randomly assigned to each of 15 mulligan taping and repeat measurement groups. The mulligan taping group measured the pre-test and post-test muscle activity and the grip strength three times and compared the mean values. The repeat group was repeatedly measured and measured before and after the experiment, The collected data were analyzed using SPSS statistical program. Results: There was no significant difference between mulligan taping group and repeated measurement group in changes of muscle activity. There was a significant difference between mulligan taping group and repeated measurement group in changes of grip strength. Conclusions: Mulligan taping was applied to an adult with forward head posture, there was no significant change in muscle activity of flexor carpi radialis and palmaris longus, but it seems to improve hand function by re-aligned of nearby muscles by maintaining scapular stability.