• Title/Summary/Keyword: Volume Calibration

Search Result 252, Processing Time 0.027 seconds

Development of a Water Quality Model for Streams in an Upland Agricultural Watershed (농촌 유역 상단부의 소하천에서 수질예측모형의 개발)

  • Choe, Hye-Suk;O, Gwang-Jung;Kim, Sang-Hyeon
    • Journal of Korea Water Resources Association
    • /
    • v.33 no.1
    • /
    • pp.73-85
    • /
    • 2000
  • A water quality model was developed for small stream at a upland agricultural watershed. A control volume method was employed to digest the severe variability of stream shape, water quality and discharge at small streams. We estimated optimum reaction coefficients and model structure using a random number generation technique. The index of agreement and coefficient of efficiency were introduced for the model calibration criterion. As the result, the reliability of model parameter estimation could be improved. The applicability of model was tested by a set of sampling results at Yongduckchun in Kimhae. The variability of water quality reaction coefficient was explored through the observed data and using the developed model. model.

  • PDF

Preliminary Study on the Elemental Quantification of in Ambient Liquid Samples of Microliter Volume Using the In-air Micro-PIXE Technique

  • Ma, Chang-Jin;Lim, Cheol-Soo;Sakai, Takuro
    • Asian Journal of Atmospheric Environment
    • /
    • v.11 no.1
    • /
    • pp.54-60
    • /
    • 2017
  • Quantifying the trace elements in infinitesimal ambient liquid samples (e.g., single raindrop, cloud/fog water, and the soluble fraction extracted from the particles collected for a short time) is an important task for understanding formation processes, heating/cooling rates, and their health hazards. The purpose of this study is to employ an in-air micro PIXE system for quantitative analysis of the trace elements in a thimbleful of reference liquid sample. The bag type liquid sample holder originally designed with $10{\mu}m$ thick $Mylar^{(R)}$ film retained the original shape without any film perforation and apparent peaks of film blank by the end of the analysis. As one of tasks to be solved, the homogeneity of the elemental distribution in liquid reference species was verified by the X-ray line profiles for several references. It was possible to resolve the significant peaks for whole target elements corresponding to the channel number of micro-PIXE spectrum. The calibration curves for the six target elements (Si, S, Cl, Fe, Ni, and Zn) in standard solutions were successfully plotted by concentration (ppm) and ROI of interest net counts/dose (nC).

Quantitative Analysis of Twelve Marker Compounds in Palmijihwang-hwan using Ultra-Performance Liquid Chromatography Coupled with Electrospray Ionization Tandem Mass Spectrometry

  • Seo, Chang-Seob;Shin, Hyeun-Kyoo
    • Natural Product Sciences
    • /
    • v.20 no.3
    • /
    • pp.182-190
    • /
    • 2014
  • An ultra-performance liquid chromatography (UPLC) coupled with electrospray ionization (ESI) tandem mass spectrometry (MS) method was established for quantitative analysis of twelve components, allantoin (1), morroniside (2), 5-hydroxymethyl-2-furfural (5-HMF) (3), loganin (4), coumarin (5), cinnamic acid (6), mesaconitine (7), cinnamaldehyde (8), hypaconitine (9), aconitine (10), alisol B (11), and alisol B acetate (12) in a Palmijihwang-hwan decoction. The twelve constituents were separated on a UPLC BEH C18 column ($2.1{\times}100mm$, $1.7{\mu}m$) at a column temperature of $40^{\circ}C$ by gradient elution with 0.1% (v/v) formic acid in water and acetonitrile as the mobile phase. The flow rate was 0.3 mL/min and the injection volume was $2.0{\mu}L$. Calibration curves of all compounds were acquired with values of the correlation coefficient ${\geq}0.99$ within the test ranges. The limits of detection and quantification for all analytes were 0.01 - 4.53 ng/mL and 0.03 - 13.60 ng/mL, respectively. The concentrations of the compounds 1 - 9 and 12 were 72.83, 4389.00, 4859.00, 3155.17, 223.67, 33.50, 1.97, 518.00, 2.25, and $25.00{\mu}g/g$, respectively. However, compounds 10 and 11 were not detected.

Settling Velocity of Phytoplankton in the Nakdong-River (낙동강 수계의 식물플랑크톤 침강속도)

  • Jung, Yukyong;Kim, Bomchul;Shin, Myoungsun;Park, Ju-Hyun
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.6
    • /
    • pp.807-813
    • /
    • 2007
  • Settling velocity is one of major parameters determining algal biomass in water quality modeling. In this study, the settling velocity of phytoplankton was measured in reservoir and stream sites of the Nakdong River, Korea. Settling velocities of various phytoplankton species were determined by measuring algal cell biomass settled in a sedimentation cylinder. Mean settling velocities were $0.22m\;day^{-1}$ in reservoir sites and $0.33m\;day^{-1}$ in stream sites, which were relatively higher compared with other default values suggested by water quality models (e.g. $0.1m\;day^{-1}$ in CE-QUAL-W2). The lower settling velocity in reservoirs than in stream implies the adaptation of phytoplakton to low turbulence in lentic environments. Cyanobacteria showed lower settling velocity ($0.2m\;day^{-1}$) than diatoms ($0.3m\;day^{-1}$), and this phenomenon may have resulted from buoyancy mechanisms of cyanobacteria. Cell volume did not show a significant correlation with settling velocity in this study, implying that conformation factors of colonies or other factors had large effects on settling velocity of algal cells as well as cell size. The result of this study may suggest proper coefficients of settling velocity of phytoplankton in the calibration of water quality model.

Uncertainty in Determination of Menthol from Mentholated Cigarette (담배 중 멘톨 분석에 대한 불확도 측정)

  • 장기철;이운철;백순옥;한상빈
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.22 no.1
    • /
    • pp.91-98
    • /
    • 2000
  • This study was carried out to evaluate the uncertainty in the analysis of menthol content from the mentholated cigarette. Menthol in the sample cigarette was extracted with methanol containing an anethole as an internal standard, and then analyzed by gas chromatography. As the sources of uncertainty associated with the analysis of menthol, were the following points tested, such as the weighing of sample, the preparation of extracting solution, the pipetting of extracting solution into the sample, the preparation of standard solution, the precision of GC injections for standard & sample solution, the GC response factor of standard solution, the reproducibility of menthol analysis, and the determination of water content in tobacco, etc. For calculating the uncertainties, type A of uncertainty was evaluated by the statistical analysis of a series of observation, and type B by the information based on supplier's catalogue and/or certificated of calibration. Sources of uncertainty were subsequently included and mathematically combined with the uncertainty arising from the assessment of accuracy to provide the overall uncertainty. It was shown that the main source of uncertainty came from the errors in the reproducibility of menthol and water determination, the purity of menthol reference material in the preparation of standard solution, and the precision of GC injections for sample solution. The errors in sample weighing and volume measurement contributed relatively little to the overall uncertainty. The expanded uncertainty in the mentholated cigarettes, Korean and American brand, at 0.95 level of statistical confidence was $\pm$0.06 and $\pm$0.07 mg/g for a menthol content of 1.89 and 2.32 mg/g, respectively.

  • PDF

Applicability Examination of the RUSLE Sediment Yield Prediction Equation in Korea (해외토사유출량 산정공식의 국내적용성 검토(II);MUSLE를 중심으로)

  • Son, Gwang-Ik
    • Journal of Korea Water Resources Association
    • /
    • v.34 no.3
    • /
    • pp.209-216
    • /
    • 2001
  • Universal Soil Loss Equation(USLE) was developed for the estimation of the annual average soil loss from farm land. But, USLE has been applied in estimation of the sediment yield due to the construction activities in Korea without any calibration for last couple of years. Therefore, applicability and the limitation of the MUSLE(modified USLE), which was developed for the estimation of the sediment yield due to single rainfall event, is examined by application of MUSLE into several construction sites and comparing the estimated sediment yields with the actual ones. It is found that MUSLE could be applied in Korea as long as the concentration time, runoff volume and the peak flow rate are estimated with appropriate methods. Comparisons between the applicability of RUSLE and MUSLE are also carried out.

  • PDF

Surface-Enhanced Raman Scattering Spectroscopic Identification of Genotoxic Nucleobase Adducts (표면강화 라만분광학을 이용한 nucleobase 유도체 분석)

  • Kim, Jae-Ho
    • Analytical Science and Technology
    • /
    • v.8 no.3
    • /
    • pp.313-319
    • /
    • 1995
  • Surface-enhanced Raman scattering(SERS) spectroscopy was employed to analyze the genotoxic nucleobase adducts of benzo[a]pyrene(BP) formed through one-electron oxidation pathway. SERS spectroscopy provided sufficient resolution to distinguish if BP intermediate was bound to different nucleobases(e. g. adenine or guanine). Furthermore, SERS specroscopy was also able to detect the difference in the binding position of the adduct to the various sites of the nucleobase. The linearity of the calibration curve for N7Ade-BP ranged from 20 picogram to 800 nanogram per microliter and the detection limit under the current conditions was determined 20 picogram per microliter in a solution volume of 20 microliter.

  • PDF

A Study on the Application of Phased Array Ultrasonic Testing to Main Steam Line in Nuclear Power Plants (원전 주증기배관 웰더렛 용접부 위상배열초음파검사 적용연구)

  • Lee, Seung-Pyo;Kim, Jin-Hoi
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.7 no.3
    • /
    • pp.40-47
    • /
    • 2011
  • KSNPs(Korea Standard Nuclear Power Plant) have been applied the break exclusion criteria to the high energy lines passing through containment penetration area to ensure that piping failures would not cause the loss of containment isolation function, and to reduce the resulting dynamic effects. Systems with the criteria are the Main Steam system, Feed Water system, Steam Generator Blowdown system, and Chemical & Volume Control system. In accordance with FSAR(Final Safety Analysis Report), a 100% volumetric examination by augmented in-service inspection of all pipe welds appled the break exclusion criteria is required for the break exclusion application piping. However, it is difficult to fully satisfy the requirements of inspection because 12", 8" and 6" weldolet weldments of Main Steam pipe line have complex structural shapes. To resolve the difficulty on the application of conventional UT(Ultrasonic Testing) technique, realistic mock-ups and UT calibration blocks were made. Simulations of conventional UT were performed utilizing CIVA, a commercial NDE(Nondestructive Examination) simulation software. Phased array UT experiments were performed through mock-up including artificial notch type flaws. A phased array UT technique is finally developed to improve the reliability of ultrasonic test at main steam line pipe to 12", 8" and 6" branch connection weld.

Mornitoring of non-steroidal anti-inflammatory drugs in livestock products (축산식품 중 비스테로이드성 항염증 약물의 잔류함량 모니터링)

  • Choi, Yoon-Hwa;Kim, Yoen-Joo;Shin, Bang-Woo;Lee, Jung-Hark
    • Korean Journal of Veterinary Service
    • /
    • v.34 no.3
    • /
    • pp.285-289
    • /
    • 2011
  • This study was conducted to determine the content of non-steroidal anti-inflammatory drugs (NSAIDs) in meats available on the Korean markets. The analysis was carried out using following conditions; C18 column ($100{\times}2.1$ mm, 1.7 ${\mu}m$), mobile phase composed of DW (containing 0.1% formic acid): acetonitrile (containing 0.1% formic acid), binary pump at a flow rate of 0.3 ml/min and 5 ${\mu}l$ of injection volume, MS/MS detector with ESI positive mode. The calibration range of five NSAIDs showed linearity ($r^2{\geq}0.99$) at concentration range of 3.125~200 ${\mu}g$/kg. The recoveries in fortified muscle more than 78.7~100.3%. The detection limits for meloxicam, ketoprofen, flunixin, carprofen and tolfenamic acid were 3.5, 1.6, 1.7, 9.8 and 4.8 ${\mu}g$/kg, respectively. We also monitored NSAIDs residue in cattle muscle 51 samples. The test results, NSAIDs were all not founded.

ANALYSIS BY SYNTHESIS FOR ESTIMATION OF DOSE CALCULATION WITH gMOCREN AND GEANT4 IN MEDICAL IMAGE

  • Lee, Jeong-Ok;Kang, Jeong-Ku;Kim, Jhin-Kee;Kim, Bu-Gil;Jeong, Dong-Hyeok
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.3
    • /
    • pp.146-148
    • /
    • 2012
  • The use of GEANT4 simulation toolkit has increased in the radiation medical field for the design of treatment system and the calibration or validation of treatment plans. Moreover, it is used especially on calculating dose simulation using medical data for radiation therapy. However, using internal visualization tool of GEANT4 detector constructions on expressing dose result has deficiencies because it cannot display isodose line. No one has attempted to use this code to a real patient's data. Therefore, to complement this problem, using the result of gMocren that is a three-dimensional volume-visualizing tool, we tried to display a simulated dose distribution and isodose line on medical image. In addition, we have compared cross-validation on the result of gMocren and GEANT4 simulation with commercial radiation treatment planning system. We have extracted the analyzed data of dose distribution, using real patient's medical image data with a program based on Monte Carlo simulation and visualization tool for radiation isodose mapping.