DOI QR코드

DOI QR Code

Preliminary Study on the Elemental Quantification of in Ambient Liquid Samples of Microliter Volume Using the In-air Micro-PIXE Technique

  • Ma, Chang-Jin (Department of Environmental Science, Fukuoka Women's University) ;
  • Lim, Cheol-Soo (Department of Air Quality Research, National Institute of Environmental Research) ;
  • Sakai, Takuro (Advanced radiation technology center, Japan Atomic Energy Research Institute)
  • Received : 2016.11.21
  • Accepted : 2016.12.14
  • Published : 2017.03.31

Abstract

Quantifying the trace elements in infinitesimal ambient liquid samples (e.g., single raindrop, cloud/fog water, and the soluble fraction extracted from the particles collected for a short time) is an important task for understanding formation processes, heating/cooling rates, and their health hazards. The purpose of this study is to employ an in-air micro PIXE system for quantitative analysis of the trace elements in a thimbleful of reference liquid sample. The bag type liquid sample holder originally designed with $10{\mu}m$ thick $Mylar^{(R)}$ film retained the original shape without any film perforation and apparent peaks of film blank by the end of the analysis. As one of tasks to be solved, the homogeneity of the elemental distribution in liquid reference species was verified by the X-ray line profiles for several references. It was possible to resolve the significant peaks for whole target elements corresponding to the channel number of micro-PIXE spectrum. The calibration curves for the six target elements (Si, S, Cl, Fe, Ni, and Zn) in standard solutions were successfully plotted by concentration (ppm) and ROI of interest net counts/dose (nC).

Keywords

References

  1. Garrod, A.N.I., Rimmer, D.A., Robertshaw, L., Jones, T. (1998). Occupational exposure through spraying remedial pesticides. Annals of Occupational Hygiene 42, 159-165. https://doi.org/10.1016/S0003-4878(98)00006-4
  2. Kikuchi, R., Inotume, J., Yoshimura, K., Kajikawa, M., Ogawa, N., Sera, K., Ozeki, T. (2003) Transport course of insoluble and soluble substances of fog water in Akita prefecture in northern Japan. International Journal of PIXE 13, 81-87. https://doi.org/10.1142/S0129083503000129
  3. Lin, T.-L., Luo, C.-S., Chou, J.-C. (1979) Matrix effects in PIXE analysis on liquid samples with an external beam. Nuclear Instruments and Methods 159, 387-393. https://doi.org/10.1016/0029-554X(79)90665-7
  4. Moore, K.F., Sherman, D.E., Reilly, J.E., Collett Jr., J.L. (2002) Development of a multi-stage cloud water collector Part 1: Design and field performance evaluation. Atmospheric Environment 36, 31-44. https://doi.org/10.1016/S1352-2310(01)00476-9
  5. Morrow, P.E. (1992) Dust overloading of the lungs: update and appraisal. Toxicology and Applied Pharmacology 113, 1-12. https://doi.org/10.1016/0041-008X(92)90002-A
  6. Munger, J.W., Jacob, D.J., Waldman, J.M., Hoffmann, M.R. (1983) Fogwater chemistry in an urban atmosphere. Journal of Geophysical Research 88, 5109-5121. https://doi.org/10.1029/JC088iC09p05109
  7. Oberdorster, G. (2000). Pulmonary effects of inhaled ultrafine particles. International Archives of Occupational and Environmental Health 74, 1-8. https://doi.org/10.1007/s004200000185
  8. Poli, V.S., Tabacniks, M.H., Rizzutto, M.A., Added, N., Espinoza-Quinones, F.R., Palacio, S.M. (2004) SRTXRF detection limit reduction using thin polymer film substrates. Brazilian Journal of Physics 34, 970-972. https://doi.org/10.1590/S0103-97332004000500072
  9. Sakai, T., Kamiya, T., Oikawa, M., Sato, T., Tanaka, A., Ishii, K. (2002) JAERI Takasaki in-air micro-PIXE system for various applications. Nuclear Instruments and Methods in Physics Research Section B 190, 271-275. https://doi.org/10.1016/S0168-583X(02)00469-X