• 제목/요약/키워드: Voltage deviation

검색결과 315건 처리시간 0.024초

저전압용 CMOS 온-칩 기준 전압 및 전류 회로 (CMOS on-chip voltage and current reference circuits for low-voltage applications)

  • 김민정;이승훈
    • 전자공학회논문지C
    • /
    • 제34C권4호
    • /
    • pp.1-15
    • /
    • 1997
  • This paper proposes CMOS on-chip voltage and current reference circuits that operate at supply voltages between 2.5V and 5.5V without using a vonventional bandgap voltage structure. The proposed reference circuits based on enhancement-type MOS transistors show low cost, compatibility with other on-chip MOS circuits, low-power consumption, and small-chip size. The prototype was implemented in a 0.6 um n-well single-poly double-metal CMOS process and occupies an active die area of $710 um \times 190 um$. The proposed voltage reference realizes a mean value of 0.97 V with a standard deviation of $\pm0.39 mV$, and a temperature coefficient of $8.2 ppm/^{\circ}C$ over an extended temeprature range from TEX>$-25^{\circ}C$ to $75^{\circ}C$. A measured PSRR (power supply rejection ratio) is about -67 dB at 50kHz.

  • PDF

전압, 무효전력의 계산기제어에 관한 연구 1 (A Study on Computer Control of Voltage-Rective Power Part 1-Development of Computer Control Seheme)

  • 송길영
    • 전기의세계
    • /
    • 제25권6호
    • /
    • pp.81-88
    • /
    • 1976
  • The present voltage-reactive power control aims at an overall coordination of reactive power sources and voltage regulation devices to keep the bus voltages within their allowable bounds on one hand and to reduce the transmission losses on the other. This paper presents an efficient computer control scheme for the real-time control of system voltage and reactive power on the basis of a simplified linear equation by using the system characteristic constant. Computational algorithm is used for the minimization of bus voltage deviation in the first phase of optimization and for the reduction of transmission losses under the constraint of vlotage settling condition in the second phase. The numerical example for sample practical system is also given. The present study on the computer control scheme will contribute to the automation of power system operation in the near future.

  • PDF

Distributed Secondary Voltage Control of Islanded Microgrids with Event-Triggered Scheme

  • Guo, Qian;Cai, Hui;Wang, Ying;Chen, Weimin
    • Journal of Power Electronics
    • /
    • 제17권6호
    • /
    • pp.1650-1657
    • /
    • 2017
  • In this study, the distributed secondary voltage control of islanded microgrids with multi-agent consensus algorithm is investigated. As an alternative to a time-triggered approach, an event-triggered scheme is proposed to reduce the communication load among inverter-based distributed generators (DGs). The proposed aperiodic control scheme reduced unnecessary utilization of limited network bandwidth without degrading control performance. By properly establishing a distributed triggering condition in DG local controller, each inverter is only required to send voltage information when its own event occurs. The compensation of voltage amplitude deviation can be realized, and redundant data exchange related to fixed high sampling rate can be avoided. Therefore, an efficient use of communication infrastructure can be realized, particularly when the system is operating in steady state. The effectiveness of the proposed scheme is verified by simulations on a microgrid test system.

상전압 및 선간전압에 대한 불평형율 (Voltage Unbalance Factor for Phase and Line Voltage)

  • 김종겸;박영진;이동주;이종한;이은웅
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2005년도 춘계학술대회논문집
    • /
    • pp.74-77
    • /
    • 2005
  • Most of the loads in industrial power distribution systems are balanced and connected to three power systems. However, voltage unbalance is generated at the user's 3-phase 4-wire distribution systems with single & three phase. Voltage unbalance is mainly affected by load system rather than power system. Unbalanced voltage will draws a highly unbalanced current and results in the temperature rise and the low output characteristics at the machine. It is necessary to analyse correct voltage unbalance factor for reduction of side effects in the industrial sites. Voltage unbalance is usually defined by the maximum percent deviation of voltages from their average value, by the method of symmetrical components or by the expression in a more user-friendly form which requires only the three line voltage readings. If the neutral point is moved at the 3-phase 4-wire system by the unbalanced load, by the conventional analytical method, line and phase voltage unbalance leads to different results due to zero-sequence component. This paper presents a new analytical method for phase and line voltage unbalance factor in 4-wire systems. Two methods indicate exact results.

  • PDF

Coordinated Voltage and Reactive Power Control Strategy with Distributed Generator for Improving the Operational Efficiency

  • Jeong, Ki-Seok;Lee, Hyun-Chul;Baek, Young-Sik;Park, Ji-Ho
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권6호
    • /
    • pp.1261-1268
    • /
    • 2013
  • This study proposes a voltage and reactive coordinative control strategy with distributed generator (DG) in a distribution power system. The aim is to determine the optimum dispatch schedules for an on-load tap changer (OLTC), distributed generator settings and all shunt capacitor switching on the load and DG generation profile in a day. The proposed method minimizes the real power losses and improves the voltage profile using squared deviations of bus voltages. The results indicate that the proposed method reduces the real losses and voltage fluctuations and improve receiving power factor. This paper proposes coordinated voltage and reactive power control methods that adjust optimal control values of capacitor banks, OLTC, and the AVR of DGs by using a voltage sensitivity factor (VSF) and dynamic programming (DP) with branch-and-bound (B&B) method. To avoid the computational burden, we try to limit the possible states to 24 stages by using a flexible searching space at each stage. Finally, we will show the effectiveness of the proposed method by using operational cost of real power losses and voltage deviation factor as evaluation index for a whole day in a power system with distributed generators.

A Communicationless PCC Voltage Compensation Using an Improved Droop Control Scheme in Islanding Microgrids

  • Ding, Guangqian;Gao, Feng;Li, Ruisheng;Wu, Bingxin
    • Journal of Power Electronics
    • /
    • 제17권1호
    • /
    • pp.294-304
    • /
    • 2017
  • This paper proposes a point of common coupling (PCC) voltage compensation method for islanding microgrids using an improved power sharing control scheme among distributed generators (DGs) without communication. The PCC voltage compensation algorithm is implemented in the droop control scheme to reduce the PCC voltage deviation produced by the droop controller itself and the voltage drop on the line impedance. The control scheme of each individual DG unit is designed to use only locally measured feedback variables and an obtained line impedance to calculate the PCC voltage. Therefore, traditional voltage measurement devices installed at the PCC as well as communication between the PCC and the DGs are not required. The proposed control scheme can maintain the PCC voltage amplitude within an allowed range even to some extent assuming inaccurate line impedance parameters. In addition, it can achieve proper power sharing in islanding microgrids. Experimental results obtained under accurate and inaccurate line impedances are presented to show the performance of the proposed control scheme in islanding microgrids.

A Resistance Deviation-To-Time Interval Converter Based On Dual-Slope Integration

  • Shang, Zhi-Heng;Chung, Won-Sup;Son, Sang-Hee
    • 전기전자학회논문지
    • /
    • 제19권4호
    • /
    • pp.479-485
    • /
    • 2015
  • A resistance deviation-to-time interval converter based on dual-slope integration using second generation current conveyors (CCIIs) is designed for connecting resistive bridge sensors with a digital system. It consists of a differential integrator using CCIIs, a voltage comparator, and a digital control logic for controlling four analog switches. Experimental results exhibit that a conversion sensitivity amounts to $15.56{\mu}s/{\Omega}$ over the resistance deviation range of $0-200{\Omega}$ and its linearity error is less than ${\pm}0.02%$. Its temperature stability is less than $220ppm/^{\circ}C$ in the temperature range of $-25-85^{\circ}C$. Power dissipation of the converter is 60.2 mW.

온라인 무정전전원장치의 병렬운전 제어기술 (Parallel Operation Control Technique of On-line UPS System)

  • 조준석;강병희;고재석;최규하;김진홍;정석언
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.501-505
    • /
    • 2001
  • The parallel operation system of UPS is used to increase reliability of power source at critical load. But parallel UPS system has a few defects, impedance is different from each other and circulating current occurs between UPSs, due to line impedance and parameter variation, though controlled by the same synchronization signal. According to such characteristic of parallel UPS, balanced load-sharing control is the most important technique in parallel UPS operation. In this paper, a novel power deviation compensation algorithm is proposed. it is composed of voltage controller to compensate power deviation that be calculated by using active and reactive current deviation between inverters on synchronous d-q reference frame.

  • PDF

무정전전원장치의 병렬운전 제어기법에 관한 연구 (A Study on the Parallel Operation Control Technique of On-line UPS System)

  • 곽철훈;최규하
    • 전력전자학회논문지
    • /
    • 제8권6호
    • /
    • pp.585-592
    • /
    • 2003
  • The parallel operation system of UPS is used to increase reliability of power source at critical load. But parallel UPS system has a few defects, impedance is different from each other and circulating current occurs between UPSs, due to line impedance and parameter variation, though controlled by the same synchronization signal. According to such characteristic of parallel UPS, balanced load-sharing control is the most important technique in parallel UPS operation. In this paper, a novel power deviation compensation algorithm is proposed. it is composed of voltage controller to compensate power deviation that be calculated by using active and reactive current deviation between Inverters on synchronous d-q reference frame.

정전분무모드에 관한 액적특성의 실험적 연구 (Experimental Study of Droplet Characteristics Related to Electrospray Mode)

  • 김지엽;이도현;조주형;홍정구
    • 한국분무공학회지
    • /
    • 제27권1호
    • /
    • pp.26-35
    • /
    • 2022
  • Electrospray is a method of atomizing fluid using high voltage supply and capable of generating continuous flow and coherent size of droplets. Electrical system and properties of fluids has enabled electrospray to have various spray modes. However, its studies have been confined only in Cone jet, which is more stable and easier to manipulate droplets' size than other spraying modes. Therefore, it is necessary to investigate and compare other spraying modes based on experimental parameters and physical properties of fluids. This research paper identified nine different spray modes. It was found out that Sauter Mean Diameter (SMD) is proportional to flow rate of fluids and maximum difference among spray modes was 1.7 times. On the other hand, SMD standard deviation had low variations on specific flow rates of fluids. Pulsed jet mode recorded the largest SMD standard deviation, while Spindle recorded the lowest.