• 제목/요약/키워드: Voltage Rising

검색결과 237건 처리시간 0.031초

3상 PWM 정류기의 경부하시 입력전류 THD 저감을 위한 d축 전류리플 저감 PWM 방법 (PWM Method with Low d-axis Current Ripple for reducing Input Current THD at Light Loads in Three Phase PWM Rectifier)

  • 진용신;신희근;김학원;조관열
    • 전력전자학회논문지
    • /
    • 제17권6호
    • /
    • pp.478-485
    • /
    • 2012
  • In this paper, a new PWM method is proposed to reduce the input current harmonics of 3 phase PWM rectifier. In the conventional carrier comparison PWM method, a triangular wave is generally used as the carrier wave. However, the large d-axis current ripple by the triangle carrier wave may be a source of large input current THD(Total Harmonic Distortion). In this paper, a new carrier comparison PWM method with saw tooth wave is proposed. Depending on the sector where the voltage command vector places, one of the rising or falling saw tooth wave is selected. To reduce the switching losses of the saw tooth carrier PWM, the discontinuous PWM is also presented. The proposed PWM method can reduce the d-axis current ripple as well as the switching losses. The performance of the conventional and proposed PWM methods is verified by the simulation and experimental results.

Sputtering Technique of Magnesium Oxide Thin Film for Plasma Display Panel Applications

  • Choi Young-Wook;Kim Jee-Hyun
    • Journal of Electrical Engineering and Technology
    • /
    • 제1권1호
    • /
    • pp.110-113
    • /
    • 2006
  • A high rate deposition sputtering process of magnesium oxide thin film in oxide mode has been developed using a 20 kW unipolar pulsed power supply. The power supply was operated at a maximum constant voltage of 500 V and a constant current of 40 A. The pulse repetition rate and the duty were changed in the ranges of $10\sim50$ kHz and $10\sim60%$, respectively. The deposition rate increased with rising incident power to the target. Maximum incident power to the magnesium target was obtained by the control of frequency, duty and current. The deposition rate of a moving state was 9 nm m/min at the average power of 1.5 kW. This result shows higher deposition rate than any other previous work involving reactive sputtering in oxide mode. The thickness uniformities over the entire substrate area of $982mm{\times}563mm$ were observed at the processing pressure of $2.8\sim9.5$ mTorr. The thickness distribution was improved at lower pressure. This technique is proposed for application to a high through-put sputtering system for plasma display panels.

단상 스위치드 릴럭턴스 모터에 설치된 영구자석 기동장치의 디텐트 토크 (Detent Torque of Parking Magnet Starting Device Installed in the Single-Phase Switched Reluctance Motor)

  • 김준호;이승민
    • 한국전기전자재료학회논문지
    • /
    • 제23권5호
    • /
    • pp.408-412
    • /
    • 2010
  • The single-phase switched reluctance motor(SRM) generates the positive torque in the restricted section. So, it can not started by itself and the torque ripple is heavier than poly-phase. For self-starting and fixing rotating direction, the rotor should be placed at the rising inductance slope when stationary. The parking permanent magnet locates the rotor in the fixed position, which can be started by it-self. It is very simple and cost effective but has some drawbacks. It affects the rotor during the operation, so the characteristics of motor, such as a torque, speed, and ripple are changed to go bad. This paper presents the detent torque of parking magnet starting device through the finite element analysis and experiments. The finite element analysis is performed at incremental rotor positions over one detent torque cycle for any one pole. The prototype, fabricated in the previous research, is used for the experiments. The inductance, instant torque, and detent torque are calculated using the terminal voltage and phase current. Finally, the finite element analysis result and the experiment result are compared for analysis and validity.

정전분무의 유체 물성치와 정전 매개변수 따른 분무특성 (Spray Characteristics according to Fluid Properties and Electric Parameters of Electrospray)

  • 김지엽;홍정구
    • 한국분무공학회지
    • /
    • 제25권2호
    • /
    • pp.81-88
    • /
    • 2020
  • Electrospray is used in various industries because it can produce continuous and uniform droplets. However, it is difficult to find optimal spraying condition due to lack of data in various conditions. In this study, various conditions were divided into electric parameters and fluid property. The electric parameters set Nozzle to Substrate(NTS), nozzle diameters and the fluid property set viscosity and conductivity as conditions. In this study, it observes spray patterns, Sauter Mean Diameter(SMD) according to conditions. As a result, fluid properties had a greater effect on the cone-Jet mode than on the nozzle diameter, NTS, and flowrate. All of solutions have Stable cone-jet mode at voltage of 8.5 kV, NTS of 20 mm and nozzle diameter of 0.2 mm. SMD has 27% different depending on viscosity and conductivity. The increased flowrate and viscosity are rising break-up length and thickening jet also jet is thinned by increased conductivity. Experiments have confirmed that the jet is thickened by increased flowrate and viscosity, and that the jet is thinned by conductivity.

해수오염 된 CSPE의 물리·전기적 상태감시에 관한 연구 (A Study on Physical and Electrical Condition Monitoring of Seawater Soaked CSPE)

  • 신용덕;이정우;전황현;김인용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.1136-1137
    • /
    • 2015
  • The accelerated thermal aging of chlorosulfonated polyethylene (CSPE) was performed for 0 days, 80.82 days, and 161.63 days at $100^{\circ}C$, which is equivalent to 0y, 40y, and 80y of aging, respectively, at $50^{\circ}C$. The volume electrical resistivity of dried CSPE for 570~630 days after seawater and freshwater soaking, are $1.109{\times}10^{14}{\Omega}{\cdot}cm$, $8.546{\times}10^{13}{\Omega}{\cdot}cm$ and $8.466{\times}10^{13}{\Omega}{\cdot}cm$. The applied voltage rising time of 11~12 second and dielectric breakdown time of 9~11 second of the accelerated thermal aged CSPE is shorter than those of 12~13 and 11~13 second of the non-accelerated thermal aged CSPE, respectively. It is shown that oxidation, fragment and crack are formated at hole of dielectric breakdown in CSPE. The apparent density of dried CSPE for 750 days are $1.555g/cm^3$, $1.595g/cm^3$$1.597g/cm^3$ according to accelerated thermal aging year, respectively.

  • PDF

대정전 계통 복구를 위한 시송전 선로에 관한 연구 (A Study on transmission lines energized initially to restore wide black out Power system)

  • 이흥재;김균도;박성민;배주천;황봉환;홍순천;김기동;이남호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.377-379
    • /
    • 2001
  • When a wide area blackout occurres, reenergizing transmission lines should be done at first. The KEPCO(Korea Electric Power Corporation) divides whole power system grid into seven subsystem, and each subsystem has one of two blackstart power plants which are usually hydro or combined-combustion type, one priority power plant which should be first supplied with electric energy, and transmission lines between them. Voltage rising, line charging, and operation stability problem should be considered when these lines are reenergized. In this paper, building-up process for primary transmission system that should be energized at first is analyzed.

  • PDF

저에너지 대면적 전자빔 발생장치 개발(II) (A Development of the Low Energy Large Aperture Electron Beam Generator)

  • 우성훈;이광식;이동인;조주현;최영욱;이홍식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1767-1769
    • /
    • 1998
  • We have established a pulsed electron beam generation system with an energy of 200[keV], pulse repetition rate of 200[Hz], and several tens of [${\mu}s$] pulse width. The system is characterized by a cold cathode that is simpler than the hot cathode. Target object does not need to be scanned because of large aperture electron beam of 300[$cm^2$]. Electron source is secondary electrons that are generated when the ions from the glow discharge collide on the cathode surface. In this paper, the discharge current characteristics are investigated experimentally as a function of He gas pressure in order to obtain stable glow discharge. And computer simulations are carried out as a preliminary study for the development of low energy large aperture electron beam generator. The variation of electon beam current is investigated as a function of rising time of high voltage when 20[kV] potential is applied in 20[mTorr] pressure.

  • PDF

음영효과를 고려한 a-Si PV모듈의 출력 변화 및 최적 설계조건에 관한 연구 (Analysis of Power Variation and Design Optimization of a-Si PV Modules Considering Shading Effect)

  • 신준오;정태희;김태범;강기환;안형근;한득영
    • 한국태양에너지학회 논문집
    • /
    • 제30권6호
    • /
    • pp.102-107
    • /
    • 2010
  • a-Si solar cell has relatively dominant drift current when compared with crystalline solar cell due to the high internal electric field. Such drift current make an impact on the PV module in the local shading. In this paper, the a-Si PV module output characteristics of shading effects was approached in terms of process condition, because of the different deposition layer of thin film lead to rising the resistance. We suggested design condition to ensure the long-term durability of the module with regard to the degradation factors such as hot spot by analyzing the module specification. The result shows a remarkable difference on module uniformity for each shading position. In addition, the unbalanced power loss due to power mismatch of each module could intensify the degradation.

안전소자를 이용한 유도회로의 점화한계 개선에 관한 연구 (A Study on the Improved Ignition Limit for Inductive Circuits with Safety Components)

  • 이춘합;박민영;지승욱;김충년;이광식;심광렬
    • 한국안전학회지
    • /
    • 제19권1호
    • /
    • pp.66-71
    • /
    • 2004
  • This paper describes that the improved effects on the ignition limit are studied by parallel safety components for propane-air 5.25vol.% mixture gas in low voltage inductive circuits. The experimental devices are used in the IEC type spark ignition test apparatus. The improved effects on the ignition limit are respectively obtained as the maximum rising rate of 650%, 1,080% by composing parallel circuits between inductance and safety components (condenser and diode) as compared with disconnecting inductance with the safety components. The more values of inductance the higher improved effects of ignition limit rise. This improving method for the ignition limit is not concerned with the safety components. Diode appears to effect greatly better than condenser. It is considered that the result can be used for not only data for researches and development of intrinsically safe explosion-proof machines which are applied equipment and detectors used in hazardous areas but also for data for its equipment tests.

A Protection Circuit for the Power Supply of a Gas Discharge Lamp

  • Kim, Ho-Sung;Kim, Jong-Hyun;Baek, Ju-Won;Yoo, Dong-Wook;Jung, Hye-Man;Kim, Hee-Je
    • Journal of Power Electronics
    • /
    • 제10권6호
    • /
    • pp.777-783
    • /
    • 2010
  • In order to drive gas discharge lamps, DC-AC converters with a LCC resonant tank, whose output voltage is adjusted by a variable frequency control are frequently used. However, when they are activated by varying the operating frequency, converters are frequently damaged by unstable operation, due to the rising and falling of the operating frequency near the resonant frequency. To solve this problem, a simple protection circuit for the power supply of a gas discharge lamp is proposed in this paper. This circuit senses the primary current of the main transformer. Using this protection circuit, the operating frequency of the lamp driving inverter system is kept close to and on the right side of the resonant frequency and the inverter is always operated in the ZVS condition. The resulting stable variable frequency operation allows various gas discharge lamps to be tested without the risk of damaging the main switches, because the protection circuit can protect the power MOSFETs of bridge converters from abnormal conditions. The validity and effectiveness of the proposed protection circuit are verified through the experimental results.