Evaluation of Image Quality and Stability of Radiation Output according to Change in Tube Voltage and Sensitivity when Abdomen and Pelvis Examination of Digital Radiography (DR) (디지털 방사선 시스템(DR)의 복부와 골반부 검사 시 관전압과 감도 변화에 따른 영상 화질과 방사선 출력의 안정성 평가)

  • Hwang, Jun-Ho;Yang, Hyung-Jin;Choi, Ji-An;Lee, Kyung-Bae
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.12
    • /
    • pp.517-526
    • /
    • 2019
  • The purpose of this study is to find the optimal method for clinical application by analyzing image quality and radiation output according to parameter combination when using the Automatic Exposure Control (AEC). The experimental method combines 70, 81 kVp with sensitivity S200, S400, S800 and S1000 of the Automatic Exposure Control for Entrance Surface Dose (ESD), current volume, Signal to Noise Ratio (SNR), Contrast to Noise Ratio (CNR), Time-to-Radiation Dose Curve in abdomen and pelvis. And then, image quality and radiation output stability were evaluated. As a results, Entrance Surface Dose, current volume, Signal to Noise Ratio, Contrast to Noise Ratio decreased as the tube voltage and sensitivity were set higher. In addition, the higher tube voltage and sensitivity, the Time-to-Radiation Dose Curve showed a poor output stability. In conclusion, the higher the combination of tube voltage and sensitivity in the use of Automatic Exposure Control, the more problems can be seen in image quality and stability of the radiation output. Therefore, a relatively low combination of tube voltage and sensitivity showed that the image quality and radiation output stability could be optimized by minimizing the error range that would occur when the detector recognized a combination of parameters.

A Study on the Design of Amplifier for Source Driver IC applicable to the large TFT-LCD TV (대형 TFT-LCD TV에 적용 가능한 Source Driver IC 감마보정전압 구동용 앰프설계에 관한 연구)

  • Son, Sang-Hee
    • Journal of IKEEE
    • /
    • v.14 no.2
    • /
    • pp.51-57
    • /
    • 2010
  • A CMOS rail-to-rail high voltage buffer amplifier is proposed to drive the gamma correction reference voltage of large TFT LCD panels. It is operating by a single supply and only shows current consumption of 0.5mA at 18V power supply voltage. The circuit is designed to drive the gamma correction voltage of 8-bit or 10-bit high resolution TFT LCD panels. The buffer has high slew rate, 0.5mA static current and 1k$\Omega$ resistive and capacitive load driving capability. Also, it offers wide supply range, offset voltages below 50mV at 5mA constant output current, and below 2.5mV input referred offset voltage. To achieve wide-swing input and output dynamic range, current mirrored n-channel differential amplifier, p-channel differential amplifier, a class-AB push-pull output stage and a input level detector using hysteresis comparator are applied. The proposed circuit is realized in a high voltage 0.18um 18V CMOS process technology for display driver IC. The circuit operates at supply voltages from 8V to 18V.

Development of Hard-wired Instrumentation and Control for the Neutral Beam Test Facility at KAERI

  • Jung Ki-Sok;Yoon Byung-Joo;Yoon Jae-Sung;Seo Min-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.3
    • /
    • pp.359-365
    • /
    • 2006
  • Since the start of the KSTAR (Korea Superconducting Tokamak Advanced Research) project, Instrumentation and Control (I&C) of the Neutral Beam Test Facility (NB-TF) has been striving to answer diverse requests arising from various facets during the project's development and construction phases. Hard-wired electrical circuits have been designed, tested, fabricated, and finally installed to the relevant parts of the system. In relation to the vacuum system I&C, controlling functions for the rotary pumps, a Roots pump, two turbomolecular pumps, and four cryosorption pumps have been constructed. I&C for the ion source operation are the temperature and flow rate signal monitoring, Langmuir probe signal measurements, gradient grid current measurements, and arc detector circuit. For the huge power system to be monitored or safely operated, many temperature measurement functions have also been implemented for the beam line components like the neutralizer, bending magnet, ion dump, and calorimeter. Nearly all of the control and probe signals between the NB test stand and the control room were made to be transmitted through the optical cables. Failures of coolant flow or beam line vacuum pressure were made to be safely blocked from influencing the system by an appropriate interlock circuit that will shut down the extraction voltage application to the system or prevent damages to the vacuum components. Preliminary estimation of the beam power through the calorimetric measurement shows that 87.9% of the total power of the 60kV/18A beam with 200 seconds duration is absorbed by the calorimeter surface. Most of these I&C results would be highly appropriate for the construction of the main NBI facility for the KSTAR national fusion research project.

Implementation of Multiple Frequency Bioelectrical Impedance Analysis System for Body Composition Analysis (신체 성분 분석을 위한 다 주파수 생체전기 임피던스 분석 시스템 구현)

  • Kim, Seong-Cheol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.11
    • /
    • pp.5403-5408
    • /
    • 2012
  • In this paper, we introduce the multiple frequency bio-electrical impedance analysis method for body composition analysis. And then we implement the multiple frequency bio-electrical impedance analysis system. Overall system consists of: multiple frequency alternating current signal generator contained alternating current signal, phase signal detector, voltage signal detector, micro controller, in-out device(key-pad LCD), conductivity electrodes, system power. We explain the architecture of the system and required theory to implement the system. In order to investigate the clinical significance of the body composition data, compare to the data measured by the expert body composition analyzer which provide high reproduction and precision. Finally, experimental results which are the correlation between the measured data show the very high reproduction performance of the body composition analysis in the proposed system.

Design of a W-band Radiometer Simultaneously Operating with a Single-Antenna Configured FMCW Radar (단일 안테나를 사용하는 FMCW 레이더와 동시 운용이 가능한 W-대역 레디오미터 설계)

  • Jung Myung-Suk;Kim Wan-Joo
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.43 no.4 s.346
    • /
    • pp.67-74
    • /
    • 2006
  • We present the design of a radiometer in W-band which operates simultaneously with a single antenna configured FMCW radar. We choose a total power radiometer(TPR) which shares an antenna and a front-end with the radar for miniaturizing the system. We separate the radiometer signal from the radar signal using a diplexer in IF band. Because the radiometer has an unwanted transmitter section due to the common use of the MMW front-end with the radar, some additional noise signals caused by the transmitter degrade the sensitivity of the radiometer system. To compensate the degradation of sensitivity, we use matching circuits and a diode detector configured as the voltage doubler. Through some experiments, we have verified that the designed radiometer system has good performances in detecting metal targets tying at several hundred meters.

Development of Digital Radiography System Using by an One Dimensional MWPC (1차원 MWPC를 이용한 디지탈 X-선 사진촬영장치의 개발)

  • Park, Jung-Byung;Moon, Myung-Kook;Goo, Sung-Mo;Cho, Jin-Ho;Kim, Do-Sung;Kang, Hee-Dong
    • Journal of Sensor Science and Technology
    • /
    • v.4 no.4
    • /
    • pp.62-69
    • /
    • 1995
  • We have developed the digital radiography system applied by the one dimensional multiwire proportional chamber. X-ray position signals were obtained from anode wires which were connected to counters through amplifiers and discriminators. The chamber was made of gas flow type and detector gas was P10. The threshold voltage which gives to the discriminator is independent on the neighboring channels. This improved the uniformity of the detector. Then the differential nonlineality is ${\pm}4%$. Increasing the gas pressure, the spatial resolution is about 1.4-mm at which the pitch of the anode wire is 2-mm. The object is scanned in vertical direction to take an image. The number of pixels in the image is $32{\times}32$.

  • PDF

Design and Evaluation of a High Concentration, High Penetration Unipolar Corona Ionizer for Electrostatic Discharge and Aerosol Charging

  • Intra, Panich;Tippayawong, Nakorn
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.5
    • /
    • pp.1175-1181
    • /
    • 2013
  • The aim of this paper is to design and evaluate a high concentration, high penetration unipolar corona ionizer. The electrostatic characteristics in terms of voltage-current relationships of the present ionizer in the discharge zones for positive and negative coronas were discussed. Using ion current measurement, the concentration and penetration of ions were evaluated at corona voltages across the needle electrodes between 1 and 4 kV, flow rates between 1 and 5 L/min, and an operating pressure of 1 atm. In the discharge zone of the ionizer, the highest ion concentrations were found to be about $1.71{\times}10^{14}$ and $5.09{\times}10^{14}\;ions/m^3$ for positive and negative coronas, respectively. At the outlet of the ionizer, it was found that the highest ion concentration was about $1.95{\times}10^{13}$ and $1.91{\times}10^{13}\;ions/m^3$ for positive and negative coronas, respectively. The highest ion penetration for positive and negative coronas through the ionizer was found to be about 98 % and 33 %, respectively. The $N_it$ product for positive and negative coronas was also found to $1.28{\times}10^{13}$ and $7.43{\times}10^{13}\;ions/m^3s$, respectively. From the findings, this ionizer proved to be particularly useful as an aerosol charger for positive and negative charge before the detector in an electrical aerosol detector.

A readout method using pulse peak-time capture for radiation detectors (펄스의 피크시각 포착을 이용한 방사선 검출기의 신호처리 방법)

  • Kim, Jong-ho;Kwon, Young-mok;Hong, Hyoung-pyo;Che, Gyu-shik
    • Journal of Advanced Navigation Technology
    • /
    • v.21 no.6
    • /
    • pp.651-658
    • /
    • 2017
  • There were many studies on the development of radiation measuring instruments to detect the presence of radiation. In particular, the signal processing method and treatment without loss of the detection signal are very important. The common feature for these studies is the peak-hold method that keeps the peak value of input signal uniform for a short time, readouts its value, discharges electrical value, and then waits for next signal. We propose the new methodology to capture the pulse peak value from the radiation detector and read the value directly other than peak-hold method. This method has merit of accurate reading the input signal pulse peak value without complicate process of holding for a period or initializing of input signal, and then be verified to be adequate through simulation of actual example.

Design of a Timing Error Detector Using Built-In current Sensor (내장형 전류 감지회로를 이용한 타이밍 오류 검출기 설계)

  • Kang, Jang-Hee;Jeong, Han-Chul;Kwak, Chol-Ho;Kim, Jeong-Beom
    • Journal of IKEEE
    • /
    • v.8 no.1 s.14
    • /
    • pp.12-21
    • /
    • 2004
  • Error control is one of major concerns in many electronic systems. Experience shows that most malfunctions during system operation are caused by transient faults, which often mean abnormal signal delays that may result in violations of circuit element timing constraints. This paper presents a novel CMOS-based concurrent timing error detector that makes a flip-flop to sense and then signal whether its data has been potentially corrupted or not by a setup or hold timing violation. Designed circuit performs a quiescent supply current evaluation to determine timing violation from the input changes in relation to a clock edge. If the input is too close to the clock time, the resulting switching transient current in the detection circuit exceeds a reference threshold at the instant of the clock transition and an error is flagged. The circuit is designed with a $0.25{\mu}m$ standard CMOS technology at a 2.5 V supply voltage. The validity and effectiveness are verified through the HSPICE simulation. The simulation results in this paper shows that designed circuit can be used to detect setup and hold time violations effectively in clocked circuit element.

  • PDF

Preliminary Research of CZT Based PET System Development in KAERI

  • Jo, Woo Jin;Jeong, Manhee;Kim, Han Soo;Kim, Sang Yeol;Ha, Jang Ho
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.2
    • /
    • pp.81-86
    • /
    • 2016
  • Background: For positron emission tomography (PET) application, cadmium zinc telluride (CZT) has been investigated by several institutes to replace detectors from a conventional system using photomultipliers or Silicon-photomultipliers (SiPMs). The spatial and energy resolution in using CZT can be superior to current scintillator-based state-of-the-art PET detectors. CZT has been under development for several years at the Korea Atomic Energy Research Institute (KAERI) to provide a high performance gamma ray detection, which needs a single crystallinity, a good uniformity, a high stopping power, and a wide band gap. Materials and Methods: Before applying our own grown CZT detectors in the prototype PET system, we investigated preliminary research with a developed discrete type data acquisition (DAQ) system for coincident events at 128 anode pixels and two common cathodes of two CZT detectors from Redlen. Each detector has a $19.4{\times}19.4{\times}6mm^3$ volume size with a 2.2 mm anode pixel pitch. Discrete amplifiers consist of a preamplifier with a gain of $8mV{\cdot}fC^{-1}$ and noise of 55 equivalent noise charge (ENC), a $CR-RC^4$ shaping amplifier with a $5{\mu}s$ peak time, and an analog-to-digital converter (ADC) driver. The DAQ system has 65 mega-sample per second flash ADC, a self and external trigger, and a USB 3.0 interface. Results and Discussion: Characteristics such as the current-to-voltage curve, energy resolution, and electron mobility life-time products for CZT detectors are investigated. In addition, preliminary results of gamma ray imaging using 511 keV of a $^{22}Na$ gamma ray source were obtained. Conclusion: In this study, the DAQ system with a CZT radiation sensor was successfully developed and a PET image was acquired by two sets of the developed DAQ system.