• 제목/요약/키워드: Vibration Response

검색결과 3,345건 처리시간 0.041초

군용차량 주행 진동응답 분석 (Vibration Response Analysis of the Military Vehicle by Road Test)

  • 신동준;이종학;강영식;최지호;강동석
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.262-266
    • /
    • 2014
  • Military vehicle equipped with an antenna and a shelter for operating radar has a vibration exposure during driving time. This vibration would have influence on structure of military vehicle critically. In this paper, driving stability of the military vehicle is obtained through the vibration response analysis. And, vibration level of the military vehicle satisfied the military vibration specification through analysis and comparing the MIL-STD-810G. PSD and Grms data obtained by road test can be used for vibration test specification of cabinets and electronic equipment in shelter.

  • PDF

일차원구조물에서의 진동응답예측을 위한 진행파기법 (A Modified Travelling Wave Method for the Prediction of Vibration Response in One-dimensional Structures)

  • 채기상;이정권
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.314-318
    • /
    • 2000
  • For one-dimensional structures, a vibration response consists of direct and reflected waves from boundaries. Based on this concept of separable wave components, a modified travelling wave method (MTWM) is proposed in this paper: while all allowable waves are assumed and the boundary conditions are applied on by the conventional travealling wave method (TWM), in the proposed MTWM direct and reflected waves are assumed within the beam element, and the governing relations between direct and reflected waves are described in terms of the reflection or transmission coefficients. It is shown that the vibration response with considerable accuracy can be obtained compared to TWM for single and coupled beams. It is also shown that the band analysis to obtain quadratic response, or power flow response can be carried out by a slight change of the governing equations for one-dimensional structural systems. It is thought that the suggested MTWM can be used as a unified approach for predicting linear spectral response and/or quadratic band response involved in the one-dimensional structural vibration.

  • PDF

Stochastic vibration response of a sandwich beam with nonlinear adjustable visco-elastomer core and supported mass

  • Ying, Z.G.;Ni, Y.Q.;Duan, Y.F.
    • Structural Engineering and Mechanics
    • /
    • 제64권2호
    • /
    • pp.259-270
    • /
    • 2017
  • The stochastic vibration response of the sandwich beam with the nonlinear adjustable visco-elastomer core and supported mass under stochastic support motion excitations is studied. The nonlinear dynamic properties of the visco-elastomer core are considered. The nonlinear partial differential equations for the horizontal and vertical coupling motions of the sandwich beam are derived. An analytical solution method for the stochastic vibration response of the nonlinear sandwich beam is developed. The nonlinear partial differential equations are converted into the nonlinear ordinary differential equations representing the nonlinear stochastic multi-degree-of-freedom system by using the Galerkin method. The nonlinear stochastic system is converted further into the equivalent quasi-linear system by using the statistic linearization method. The frequency-response function, response spectral density and mean square response expressions of the nonlinear sandwich beam are obtained. Numerical results are given to illustrate new stochastic vibration response characteristics and response reduction capability of the sandwich beam with the nonlinear visco-elastomer core and supported mass under stochastic support motion excitations. The influences of geometric and physical parameters on the stochastic response of the nonlinear sandwich beam are discussed, and the numerical results of the nonlinear sandwich beam are compared with those of the sandwich beam with linear visco-elastomer core.

경부고속철도 교량의 과도한 가속도의 저감방안에 대한 연구 (A Study on the Solution of Excessive Accelerations on the Bridge for Gyeongbu High-speed Railway)

  • 곽종원;진원종;최은석;조정래;이정우
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 춘계학술대회 논문집
    • /
    • pp.477-485
    • /
    • 2007
  • When Korean High Speed Train (KTX) runs over a high-speed railway bridge, the high-speed railway bridge gives quite large acceleration response. Local vibration at the large cross section, the impact from equally spaced sleepers, the vibration due to elastomeric bearings, and the vibration from the train itself are the causes of this acceleration response. Maximum peaks of the accelerations measured at the bridges are sometimes going over the limit value. Although it is smaller than 0.35G, the limit from the Korean Bridge Design Manual(BRDM), this acceleration response should be reduced for the safety of running trains with high speed. In this paper, to reduce the acceleration response by controlling excessive local vibration at the large cross section, vibration reduction method is studied. The result shows that the effect of elastomeric bearings on the vibration of the bridge is very large and that the vibration reduction device is effective against wing mode local vibration PSC box girder bridge for the high-speed railway, which usually has very large cross section, although it has little effect on global vibration modes such as flexural and twisting modes. The test of the vibration reduction device on the bridge in service has been performed in this study.

  • PDF

부분방전 전하량에 따른 음향방출 센서의 응답특성 (Response Characteristics of Acoustic Emission Sensor according to Partial Discharge Quantities)

  • 정영호
    • 한국전기전자재료학회논문지
    • /
    • 제23권5호
    • /
    • pp.383-387
    • /
    • 2010
  • The response characteristics of AE (acoustic emission) sensors with a coupled vibration mode and a non-coupled vibration mode were investigated according to PD(partial discharge) quantities in XLPE (cross linked polyethylene) sheets and craft papers immersed in insulating oil. The response voltages of a coupled vibration mode AE sensor were linearly proportional to the PD quantities up to 1,000 pC in XLPE sheets, while a non-coupled vibration mode AE sensor did not show the similar linearity. In case of a test of craft papers immersed in insulating oil, a linearity between response voltages and PD quantities was observed up to 550 pC, but after that, similar linearity between response voltage of any types of AE sensor and PD quantities was not shown.

부분구조모델을 이용한 건축물의 국부진동해석에서의 오차원인 분석 (Error Estimate of Local Vibration for Building Structures Using Substructure Models)

  • 안상경;이현수;이동근
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.545-552
    • /
    • 2001
  • Analysis of a structure for vertical vibration requires a lot of computational efforts because large number of degrees of freedom are generally involved in the dynamic response. Especially, when a structure is loaded with local vibration source, it may not be economical to model the whole structure to obtain the responses of specific members located near or far from the sources. In this study, substructure models have been used for analysis of local vibration An analysis of local vibration is performed for the case that the loaded point and the response point are located on the same floor. Other analysis is performed for the case that the loaded point and the response point are located on the different floor. In this case, if only the floors on which loaded and response points are located are modeled, response of substructure model is very different from that of full model. So, there should be a consideration that degrees of freedom of floors in addition to those of loaded and response floors are included to improve results of dynamic analysis. In this study, floors between loaded floor and response floor were modeled so that modeshapes which affect the response are presented well.

  • PDF

정밀장비의 방진 및 과도응답 제어를 위한 하이브리드 방진시스템 (The Hybrid Control System for the Vibration Isolation and the Transient Response Reduction of precision Equipment)

  • 이규섭;손성완;이홍기;한현희;전종균
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2009년도 추계학술대회 논문집
    • /
    • pp.185-189
    • /
    • 2009
  • It is very important to control the vibration transmitted from external utilities and the transient response due to the internal sources for the precision equipment, which is very sensitive to the vibration environment. The anti-vibration tables that use air springs have been widely used due to their excellent isolation performance, but the systems with high flexibility have the critical problem of large transient response by the impulsive force of the moving mass in operation of the equipment. In this paper, the hybrid vibration control system is proposed, which is combined the air springs with the semi-active MR dampers in order to satisfy the performances of isolation and vibration reduction simutaneously.

  • PDF

차량진동에 대한 노출가스관의 방진 시스템 개발을 위한 실험적 연구 (An Experimental Study on Isolation System of Aerial Gas Pipeline for Vehicle Vibration)

  • 박연수;강성후;박선주
    • 한국소음진동공학회논문집
    • /
    • 제11권5호
    • /
    • pp.131-139
    • /
    • 2001
  • In this paper, aerials gas pipeline vibrations due to the passing of vehicles have been measured, and peak values and characteristics of vibration were analyzed. In order to develop isolation system for gas pipeline, six cases with various support condition and hanging method were tested. The hanger used instead of wore rope isolated almost all vibrations transmitted from main beam. In the results of test, we could decrease response of vibration velocity from 49 % to 56 % and response of vertical vibration acceleration from 49 % to 60 %, because hanger instead of wire rope was used and rubber pads instead of wooden shield plates at support positions for Proofing horizontal vibration were used.

  • PDF

Structural Modification for Vehicle Interior Noise Reduction Using Vibration Response Sensitivity Analysis

  • Park, Yong-Hwa;Cheung, Wan-Sup;Park, Youn-Sik
    • The Journal of the Acoustical Society of Korea
    • /
    • 제19권3E호
    • /
    • pp.3-11
    • /
    • 2000
  • A structural modification technique for reducing structure-borne noise of vehicles using a sensitivity analysis is suggested. To estimate the noises generated by the vibration response, a semi structure-acoustic coupling analysis was exploited. As a result of the coupling analysis, severe noise generating positions are identified whose vibrations should be cured through structural modifications. Formulation for the sensitivity analysis of those severe vibration responses with respect to the design changes is derived to enhance the vibration response. Special attention is given in this paper to the use of the experimentally measured vibration responses in the sensitivity analysis. As a result of the proposed method, the structural modifications can be peformed accurately by using experimental data instead of using the finite element method though the higher vibration modes are considered as long as the vibration measurement and acoustic mode calculations are accurate. Effectiveness of this method was examined using an example model by experiments.

  • PDF

점탄성물질 난류댐퍼를 이용한 V형 철골 브레이스 골조의 진동응답해석 (A Vibration Response Analysis of Steel Building Frame with V Shape Brace Vibrationally Controlled by Turbulent Flow Dampers Sealed by Visco-Elastic Material)

  • 이호;이상엽
    • 한국공간구조학회논문집
    • /
    • 제2권3호
    • /
    • pp.103-113
    • /
    • 2002
  • This thesis investigates vibration response characteristics of building frames in which dampers are installed. The frames belong to passively vibration-controlled. Structures which utilizes energy dissipation of mechanical dampers provided in the structure. In this thesis, a turbulent flow damper sealed by visco-elastic material was dealt with as the device of passive vibration control. To investigate the resisting force characteristics of the damper, harmonic vibratration tests were carried out. Based on the test results, a theoretical model of the damper resistance was presented and a method of identifying the model parameters was proposed. Shaking table tests of the frame with and without the dampers were carried out and the effectiveness of the damper was examined. The response of the frame with the dampers was reduced to 1/2 or 1/3 of the cases without the damper.

  • PDF