• Title/Summary/Keyword: Vertical gap

Search Result 292, Processing Time 0.027 seconds

Evaluation of the accuracy of two different surgical guides in dental implantology: stereolithography fabricated vs. positioning device fabricated surgical guides (제작방법에 따른 임플란트 수술 가이드의 정확성비교: stereolithography와 positioning device로 제작한 수술 가이드)

  • Kwon, Chang-Ryeol;Choi, Byung-Ho;Jeong, Seung-Mi;Joo, Sang-Dong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.4
    • /
    • pp.271-278
    • /
    • 2012
  • Purpose: Recently implant surgical guides were used for accurate and atraumatic operation. In this study, the accuracy of two different types of surgical guides, positioning device fabricated and stereolithography fabricated surgical guides, were evaluated in four different types of tooth loss models. Materials and methods: Surgical guides were fabricated with stereolithography and positioning device respectively. Implants were placed on 40 models using the two different types of surgical guides. The fitness of the surgical guides was evaluated by measuring the gap between the surgical guide and the model. The accuracy of surgical guide was evaluated on a pre- and post-surgical CT image fusion. Results: The gap between the surgical guide and the model was $1.4{\pm}0.3mm$ and $0.4{\pm}0.3mm$ for the stereolithography and positioning device surgical guide, respectively. The stereolithography showed mesiodistal angular deviation of $3.9{\pm}1.6^{\circ}$, buccolingual angular deviation of $2.7{\pm}1.5^{\circ}$ and vertical deviation of $1.9{\pm}0.9mm$, whereas the positioning device showed mesiodistal angular deviation of $0.7{\pm}0.3^{\circ}$, buccolingual angular deviation of $0.3{\pm}0.2^{\circ}$ and vertical deviation of $0.4{\pm}0.2mm$. The differences were statistically significant between the two groups (P<.05). Conclusion: The laboratory fabricated surgical guides using a positioning device allow implant placement more accurately than the stereolithography surgical guides in dental clinic.

Comparative accuracy of new implant impression technique using abutments as impression copings with an angulated implant model (경사지게 식립된 임플랜트 모형에서 지대주를 인상용 코핑으로 이용한 새로운 인상법의 정확성 비교 연구)

  • Lee, Hyeok-Jae;Kim, Chang-Whe;Lim, Young-Jun;Kim, Myung-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.2
    • /
    • pp.201-208
    • /
    • 2008
  • Statement of problem: A new implant impression technique which use abutments as impression coping, and use resin cement as a splinting material was described. Accuracy of this technique was compared with conventional closed tray and resin splinted open tray technique for a $15^{\circ}$ angled 3-implant model Material and methods: A dental stone master model with 3 linearly positioned implant analogue and a reference framework which was passively fitted to it were fabricated. The center analogue was perpendicular to the plane of model and the outer analogues had a $15^{\circ}$angulation forward or backward. 10 closed tray impressions, 10 resin splinted open tray impressions, 10 abutment-resin framework cementation impressions and 10 abutment-metal framework cementation impressions were made with additional silicone material and poured with dental stone. A light microscope with image processing was used to record the vertical gap dimension between reference framework and analogue of duplicated cast made with each 4 impression techniques. Statistical analysis used one-way ANOVA with post-hoc tests Tukey test of .05 level of significance Results: Significant difference in the vertical gap dimension was found between closed tray technique; 74.3 (${\pm}33.4$)${\mu}m$ and resin splinted open tray technique, and two other new technique. (P<.05) Abutment-metal framework cementation technique;42.5 (${\pm}11.9$)${\mu}m$ was significantly different from resin splinted open tray technique. (P<.05) Abutmentresin framework cementation technique;51.0 (${\pm}14.1$)${\mu}m$ did not differ significantly from resin splinted open tray technique;50.3 (${\pm}16.9$)${\mu}m$. (P>.05) Conclusion: Within limitations of this study, the accuracy of implant level impressions of resin splinted open tray technique was superior to that of closed tray technique. A new technique using abutment and metal framework cementation was more accurate than resin splinted open tray technique.

A Study on Provision of Real-Time Safety Information Considering Real-Time Vehicular Data and Road Traffic Condition (실시간 차량정보 및 도로교통상황을 고려한 실시간 안전정보 제공에 관한 연구)

  • Ko, Han-Geom;Lee, Jin-Soo;Kim, Ji-Ho
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.4D
    • /
    • pp.291-303
    • /
    • 2012
  • In order to lead safe driving, it is better to provide dynamic and detailed information on how the driver using the relevant road should behave as concerning movements of individual car rather than providing monotone and static information of reducing of speed to unspecified drivers. Assuming road and communication of highway where real-time collection and transfer of information on vehicles and road traffic status is possible, the purpose of this study was to provide real-time safe distance by considering road traffic condition such as road condition and driving condition, travel speed and distance between preceding/following vehicles. We intended to provide basic information about dangerous situation by defining different values of condition based column ($C_{condition}$) in accordance with the road surface condition, based on which Real-time Safety Distance Index(RSDI) is to be calculated comprehensively reflecting speed of preceding and following vehicles, distance between vehicles, vertical alignment and road surface condition on the scope of expression column ($C_n$). We intended to enable the driver to secure safety by providing the calculated Real-time Safety Distance Index (RSDI) so that the driver can intuitively sense and sufficiently cope with a dangerous situation where collision of vehicles may occur. The calculated RSDI value is comprised of 30 unit columns and will be provided to the driver being divided into risk evaluation grades of 3 predetermined steps, 'warning', 'dangerous' and 'normal'.

Optical absorption of $Mg_{0.15}Zn_{0.85}Te$ and $Mg_{0.15}Zn_{0.85}Te:Co^{2+}$ single crystal ($Mg_{0.15}Zn_{0.85}Te$$Mg_{0.15}Zn_{0.85}Te:Co^{2+}$ 단결정의 광흡수 특성)

  • 전용기
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.9 no.2
    • /
    • pp.180-184
    • /
    • 1999
  • The single crystals of $Mg_{0.15}Zn_{0.85}Te$ and $Mg_{0.15}Zn_{0.85}Te:Co^{2+}$(0.001%) were grown by vertical Bridgman method. Optical absorption properties of this compound were studied. As a result of the optical absorption spectra of $Mg_{0.15}Zn_{0.85}Te$, absorption peaks were related to exciton and the exciton level redshifts with increasing temperature, and temperature coefficient given to the value of $-5.8{\times}10^{-4}\;eV/K$ for the temperature range above 100 K. in the $Mg_{0.15}Zn_{0.85}Te:Co^{2+}$(0.001%) single crystal, the intracenter transitions due to $Co^{2+}$ ions were detected for $A-band:^4A_2(^4F) {\to}^4T_1(^4F),\; B-band:\; ^4A_2(^4F){\to}^4T_1(^4P)$, and the charge transfer transition near the absorption edge was observed in the wavelength range of 500 to 800 nm. According to the crystal field theory and Lucovsky formula, the crystal field parameter, Racah parameter and charge transfer energy were determined.

  • PDF

Low-cost Assessment of Canopy Light Interception and Leaf Area in Soybean Canopy Cover using RGB Color Images (RGB 컬러 이미지를 이용한 콩의 군락 피복과 엽면적에 대한 저비용 평가)

  • Lee, Yun-Ho;Sang, Wan-Gyu;Baek, Jae-Kyeong;Kim, Jun-Hwan;Cho, Jung-Il;Seo, Myung-Chul
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.22 no.1
    • /
    • pp.13-19
    • /
    • 2020
  • This study compared RGB color images with canopy light interception (LI) and leaf area index (LAI) measurements for low cost and low labor. LAI and LI were measured from vertical gap fraction derived from top of digital image in soybean canopy cover (cv Daewonkong, Deapongkong and Pungsannamulkong). RGB color images, LAI, and LI were collected from V4.5 stage to R5stage. Image segmentation was based on excess green minus excess red index (ExG-ExR). There was a linear relationship between LAI measured with LI (r2=0.84). There was alinear relation ship between LI measured with canopy cover on image (CCI) (r2=0.94). There was a significant positive relationship(r2=0.74) between LAI and CCI at all grow ingseason. Therefore, it is expected that in the future, the RGB color image could be able to easily measure the LAI and the LI at low cost and low labor.

Design of a Waveguide Band-Pass Filter Using a Modified H-type Resonant Iris (변형된 H-형 공진 아이리스를 이용한 도파관 대역통과 여파기 설계)

  • Park, Kyoung-Je;Choi, Tae-Ho;Lee, Jong-Ig;Kim, Byung-Mun;Cho, Young-Ki
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.2
    • /
    • pp.347-353
    • /
    • 2018
  • In this paper, we studied a design method for a band-pass waveguide filter with a modified H-type resonant iris (RI) placed in a thin transverse wall of a rectangular waveguide. The horizontal straight gap at the center of a conventional H-shaped iris is modified to a U-shaped one to increase the equivalent capacitance, and the equivalent inductance is improved by changing the vertical two straight slots into C-shaped ones. From some simulation results for the frequency response of the proposed RI, it was observed that the proposed iris was advantageous for reducing its size and having better cutoff, compared to typical H-shaped one. Equivalent inductance, capacitance, and quality factor of the proposed RI were extracted to analyze its performance. A third-order band pass filter using the proposed modified H-shaped iris was designed and, it was observed that the filter operated in the frequency range of 9.18-9.84 GHz with its insertion loss of 0.3 dB and return loss of 14 dB.

Articulatory Attributes in Korean Nonassimilating Contexts

  • Son, Minjung
    • Phonetics and Speech Sciences
    • /
    • v.5 no.1
    • /
    • pp.109-121
    • /
    • 2013
  • This study examined several kinematic properties of the primary articulator (the tongue dorsum) and the supplementary articulator (the jaw) in the articulation of the voiceless velar stop (/k/) within nonassimilating contexts. We examined in particular the spatiotemporal properties (constriction duration and constriction maxima) from the constriction onset to the constriction offset by analyzing a velar (/k/) followed by the coronal fricative (/s/), the coronal stop (/t/), and the labial (/p/) in across-word boundary conditions (/k#s/, /k#t/, and /k#p/). Along with these measurements, we investigated intergestural temporal coordination between C1 and C2 and the jaw articulator in relation to its coordination with the articulation of consonant sequences. The articulatory movement data was collected by means of electromagnetic midsagittal articulometry (EMMA). Four native speakers of Seoul Korean participated in the laboratory experiment. The results showed several characteristics. First, a velar (/k/) in C1 was not categorically reduced. Constriction duration and constriction degree of the velar (/k/) were similar within nonassimilating contexts (/k#s/=/k#t/=/k#p/). This might mean that spatiotemporal attributes during constriction duration were stable and consistent across different contexts, which might be subsequently associated with the nontarget status of the velar in place assimilation. Second, the gestural overlap could be represented as the order of /k#s/ (less) < /k#p/ (intermediate) < /k#t/ (more) as we measured the onset-to-onset lag (a longer lag indicated shorter gestural overlap.). This indicates a gestural overlap within nonassimilating contexts may not be constrained by any of the several constraints including the perceptual recoverability constraint (e.g., more overlap in Front-to-Back sequences compared to the reverse order (Back-to-Front) since perceptual cues in C1 can be recovered anytime during C2 articulation), the low-level speech motor constraint (e.g., more overlap in lingual-nonlingual sequences as compared to the lingual-lingual sequences), or phonological contexts effects (e.g., similarity in gestural overlap within nonassimilating contexts). As one possible account for more overlap in /k#t/ sequences as compared to /k#p/, we suspect speakers' knowledge may be receptive to extreme encroachment on C1 by the gestural overlap of the coronal in C2 since it does not obscure the perceptual cue of C1 as much as the labial in C2. Third, actual jaw position during C2 was higher in coronals (/s/, /t/) than in the labial (/p/). However, within the coronals, there was no manner-dependent jaw height difference in C2 (/s/=/t/). Vertical jaw position of C1 and C2 was seen as inter-dependent as higher jaw position in C1 was closely associated with C2. Lastly, a greater gap in jaw height was associated with longer intergestural timing (e.g., less overlap), but was confined to the cluster type (/kp/) with the lingual-nonlingual sequence. This study showed that Korean jaw articulation was independent from coordinating primary articulators in gestural overlap in some cluster types (/k#s/, /k#t/) while not in others (e.g., /k#p/). Overall, the results coherently indicate the velar stop (/k/) in C1 was robust in articulation, which may have subsequently contributed to the nontarget status of the velar (/k/) in place assimilation processes.

High Heat-load Slits for the PLS Multi-pole Wiggler (포항방사광가속기의 다극 위글러용 고 열량부하 슬릿)

  • Gil, K.H.;Kim, C.K.;Chung, C.W.
    • Journal of the Korean Vacuum Society
    • /
    • v.16 no.1
    • /
    • pp.46-51
    • /
    • 2007
  • The HFMX((High Flux Macromolecular X-ray crystallography) beamline at Pohang Accelerator Laboratory uses beams from a multi-pole wiggler. Two horizontal and vertical slits relevant to high heat-load are installed at its front-end. In order to treat high heat-load with reducing beam scattering, the horizontal slit has two Glidcop blocks with a grazing incidence angle of $10^{\circ}$ of a grazing-incidence knife-edge configuration. The blocks adjust the slit gap by being translated along guides by two actuating bars, respectively. Water flowing through holes, drilled along the actuating bars, cools the heat-load of both blocks. The vortical slit has the same structure as the horizontal slit except its installation direction with respect to the vacuum chamber and its grazing incidence angle. By virtue of a pair of blocks translating on guides, no alignment between both blocks is required and the installed slits show stable operating performance. The cooling performance of the two slits has been also shown to be acceptable. In this paper, the detailed explanation for the design of the two slits is presented and their operating performance is discussed.

The Accuracy of Master Cast for Implant Prosthesis According to the Types of Impression Tray and Splinting Methods of Impression Copings (인상용 트레이의 종류와 인상용 코핑의 연결고정이 임플랜트 주모형의 정확성에 미치는 영향)

  • Lee, Jee-Hyuk;Choi, Yu-Sung;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.4
    • /
    • pp.433-445
    • /
    • 2010
  • The aim of this study was to evaluate the fixation effect by connecting impression copings and to compare the three types of impression trays which were used in open tray impression technique. Experimental groups used 3 types of impression trays which are custom tray, plastic metal combination tray and polycarbonate stock tray. These three groups were subdivided into splinted and non-splinted impression copings group. The total number of experimental groups was six. 10 specimens were made for each group. We used 1-screw test, observing the specimen on which only one side abutment of reference framework was fixated with 20 Ncm. The gap between implant analogue and abutment of the other side was observed by stereo microscope. It was measured at 6 points in each specimen. Measuring value was selected when same result was revealed 3 times. Recorded data were statistically analyzed. Whether impression copings were splinted or not, there was no significant difference among custom tray group, plastic metal combination tray group, and polycarbonate stock tray group. Significant statistical difference in vertical fit discrepancy was found between splinted and non-splinted impression copings group with custom tray, plastic metal combination tray and polycarbonate stock tray (p<0.05).

Mathematician Taylor's Linear Perspective Theory and Painter Kirby's Handbook (수학자 테일러의 선 원근법과 화가 커비의 해설서)

  • Cho, Eun-Jung
    • The Journal of Art Theory & Practice
    • /
    • no.7
    • /
    • pp.165-188
    • /
    • 2009
  • In the development of linear perspective, Brook Taylor's theory has achieved a special position. With his method described in Linear Perspective(1715) and New Principles of Linear Perspective(1719), the subject of linear perspective became a generalized and abstract theory rather than a practical method for painters. He is known to be the first who used the term 'vanishing point'. Although a similar concept has been used form the early stage of Renaissance linear perspective, he developed a new method of British perspective technique of measure points based on the concept of 'vanishing points'. In the 15th and 16th century linear perspective, pictorial space is considered as independent space detached from the outer world. Albertian method of linear perspective is to construct a pavement on the picture in accordance with the centric point where the centric ray of the visual pyramid strikes the picture plane. Comparison to this traditional method, Taylor established the concent of a vanishing point (and a vanishing line), namely, the point (and the line) where a line (and a plane) through the eye point parallel to the considered line (and the plane) meets the picture plane. In the traditional situation like in Albertian method, the picture plane was assumed to be vertical and the center of the picture usually corresponded with the vanishing point. On the other hand, Taylor emphasized the role of vanishing points, and as a result, his method entered the domain of projective geometry rather than Euclidean geometry. For Taylor's theory was highly abstract and difficult to apply for the practitioners, there appeared many perspective treatises based on his theory in England since 1740s. Joshua Kirby's Dr. Brook Taylor's Method of Perspective Made Easy, Both in Theory and Practice(1754) was one of the most popular treatises among these posterior writings. As a well-known painter of the 18th century English society and perspective professor of the St. Martin's Lane Academy, Kirby tried to bridge the gap between the practice of the artists and the mathematical theory of Taylor. Trying to ease the common readers into Taylor's method, Kirby somehow abbreviated and even omitted several crucial parts of Taylor's ideas, especially concerning to the inverse problems of perspective projection. Taylor's theory and Kirby's handbook reveal us that the development of linear perspective in European society entered a transitional phase in the 18th century. In the European tradition, linear perspective means a representational system to indicated the three-dimensional nature of space and the image of objects on the two-dimensional surface, using the central projection method. However, Taylor and following scholars converted linear perspective as a complete mathematical and abstract theory. Such a development was also due to concern and interest of contemporary artists toward new visions of infinite space and kaleidoscopic phenomena of visual perception.

  • PDF