• 제목/요약/키워드: Vertical Plates

검색결과 257건 처리시간 0.022초

Highly Thermal Conductive Alumina Plate/Epoxy Composite for Electronic Packaging

  • Jeong, Un Seong;Lee, Yoon Joo;Shin, Dong Geun;Lim, Hyung Mi;Mun, So Youn;Kwon, Woo Teck;Kim, Soo Ryong;Kim, Young Hee;Shim, Kwang Bo
    • Transactions on Electrical and Electronic Materials
    • /
    • 제16권6호
    • /
    • pp.351-354
    • /
    • 2015
  • In this study, alumina plates 9~25 μm in size were used as thermal fillers, and epoxy resin was used as a polymer matrix. Oriented alumina plate/epoxy composites were prepared using a rolling method. The effect of ordering alumina plates increased with alumina plate size. The thermal conductivity and flexural strength of the composites were investigated. The horizontal thermal conductivity of the oriented composite was significantly higher than the vertical thermal conductivity. The horizontal thermal conductivity of the 75 wt% alumina content was 8.78 W/mk, although the vertical thermal conductivity was 1.04 W/mk. Ordering of the alumina plate using a rolling method significantly improved the thermal conductivity in the horizontal direction. The flexural strengths of the ordered alumina/epoxy composites prepared at different curing temperatures were measured.

섬유보강 면진베어링의 실험적 특성 해석 (An Experimental Study on Fiber Reinforced Elastomeric Bearing)

  • 문병영;강경주;강범수;김계수
    • 한국지진공학회논문집
    • /
    • 제6권1호
    • /
    • pp.1-6
    • /
    • 2002
  • 면진베어링으로 기존에 사용되고 있는 철판보강 면진베어링에서 철판을 섬유로 대체하여 섬유보강 면진베어링을 설계 및 제작하였다. 섬유면진보강베어링의 특성을 파악하기 위해서 철판보강 면진베어링과 섬유보강 면진베어링에 대해 수평실험과 압축실험을 수행하였다. 시험결과 섬유보강 면진베어링의 유효 감쇠는 천연고무 면진베어링에 비해서 높았다. 이 결과는 지진하중하에서 섬유보강 면진베어링은 에너지 분산능력이 뛰어나다는 것을 의미한다. 이 연구결과로 인해 섬유보강 면진베어링이 저가건물에 널리 사용될 수 있을 것으로 기대된다.

Improvement in uplift capacity of horizontal circular anchor plate in undrained clay by granular column

  • Bhattacharya, Paramita;Roy, Anamitra
    • Geomechanics and Engineering
    • /
    • 제10권5호
    • /
    • pp.617-633
    • /
    • 2016
  • A numerical study has been conducted to examine the improvement achieved in the ultimate pullout capacity of horizontal circular anchor plates embedded in undrained clay, by constructing granular columns of varying diameter over the anchor plates. The analysis has been carried out by using lower bound theorem of limit analysis and finite elements in combination with linear programming. The improvement in uplifting capacity of anchor plate is expressed in terms of an efficiency factor (${\xi}$). The efficiency factor (${\xi}$) has been defined as the ratio of ultimate vertical pullout capacity of anchor plate having diameter D embedded in soft clay reinforced by granular column to the vertical pullout capacity of the anchor plate with same diameter D embedded in soft clay only. The variation of efficiency factor (${\xi}$) for different embedment ratios and different diameter of granular column has been studied considering a wide range of softness of clay and different value of soil internal friction angle (${\phi}$) of the granular material. It is observed that ${\xi}$ increases with an increase in diameter of the granular column ($D_t$) and increase in friction angle of granular material. Also, the effectiveness of the usage of granular column increases with decrease in cohesion of the clay.

전자제어 엔진의 공기유량센서 유동구조 연구 (Flow Mechanism around Air Flow Sensor of Electronic Control Engine)

  • 이종춘;황성만;부정숙
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제24권4호
    • /
    • pp.486-493
    • /
    • 2000
  • Flow mechanism around air flow sensor of electronic control engine, especially Karman vortex type, was investigated experimentally. The two-dimensional flow characteristics in the intermediate wake region behind a triangular vortex-generator respectively apex forward facing, apex backward facing and vertical flat plates following after apex forward facing(i.e vortex-flowmeter) were investigated at Reynolods number of $ReH=1.4\times10^4$; H is the width of a triangular vortex-generator. The vortex shedding frequency for wide Reynolds number from $7\times10^3$ to $2.1\times10^4$ was also surveyed. The velocity component was measured by X-type hot wire anemometer at 8H downstream from the bluff body. The coherent structure of the intermediate wake behind a bluff body was obtained by conditional phase average technique. As a result, it was verified that the vertical flat plates following after apex forward triangular vortex-generator make not only more linear relation between free stream velocity and vortex shedding frequency but also more periodic vortex in the vicinity of the center of wake.

  • PDF

Underwater Laser Cutting of Thick Stainless Steel in Various Cutting Directions for Application to Nuclear Decommissioning

  • Shin, Jae Sung;Oh, Seong Y.;Park, Seung-Kyu;Kim, Taek-Soo;Park, Hyunmin;Lee, Jonghwan
    • 방사성폐기물학회지
    • /
    • 제19권3호
    • /
    • pp.279-287
    • /
    • 2021
  • For application in nuclear decommissioning, underwater laser cutting studies were conducted on thick stainless-steel plates for various cutting directions using a 6 kW fiber laser. For cutting along the horizontal direction with horizontal laser irradiation, the maximum cutting speed was 110 mm·min-1 for a 48 mm thick stainless-steel plate. For cutting along the vertical direction with horizontal laser irradiation, a maximum speed of 120 mm·min-1 was obtained for the same thickness, which confirmed that the cutting performance was similar but slightly better. Moreover, when cutting with vertically downward laser irradiation, the maximum cutting speed was 120 mm·min-1 for a plate of the same thickness. Thus, the cutting performance for vertical irradiation was nearly identical to that for horizontal irradiation. In conclusion, it was possible to cut thick stainless-steel plates regardless of the laser irradiation and cutting directions, although the assist gas rose up due to buoyancy. These observations are expected to benefit laser cutting procedures during the actual dismantling of nuclear facilities.

3차원 지반-구조물 상호작용해석을 위한 동적 무한요소 (Dynamic Infinite Elements for 3D Soil-Structure Interaction Analysis)

  • 서춘교;윤정방
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.521-528
    • /
    • 2005
  • In this paper, three dimensional dynamic infinite elements are developed for the soil-structure interaction analysis in multi-layered halfspace. For the efficient discretization of 3-D for field regions, five types of dynamic infinite elements are developed. They are the horizontal, vertical, horizontal comer, vertical comer and horizontal/vertical corner infinite elements. The shape functions of the infinite elements are based on approximate expressions of analytical solutions of propagating waves in the infinite region. Numerical example analyses are presented for compliances of rigid circular and square plates to demonstrate the effectiveness of the proposed infinite elements.

  • PDF

수직 휜을 갖는 아래 평판 위에서 등속 운동을 하는 위 평판에 의한 유동 (Flow Induced by the Uniform Motion of Top Plate over the Bottom Plate with Vertical Fin)

  • 박준상
    • 대한기계학회논문집B
    • /
    • 제25권7호
    • /
    • pp.877-884
    • /
    • 2001
  • A theoretical analysis is conducted on the Stokes flow in a narrow channel. A vertical fin is mounted on the bottom plate and the flow is induced by uniformly sliding top plate. The governing harmonic equation was solved in the transformed ζ-plane, which is obtained by applying conformal mappings to the physical plane. By using well-known transformation technique, closed-form expressions for velocity and skin frictional stress on the top and bottom plates were obtained.

수직평판 사이를 흐르는 두 점성유체의 밀도차에 의한 계면의 새로운 불안정성 연구 (A study of a new interfacial instability between two vertical fluid layers of different densities)

  • 이철우;주상우;이상천
    • 대한기계학회논문집B
    • /
    • 제20권12호
    • /
    • pp.3949-3959
    • /
    • 1996
  • A new interfacial instability between two vertical fluid layers of different densities is studied. The two layers are flowing between two parallel vertical plates vertically upward or downward, forming counter- or concurrent flows. In order to extend the study to highly-nonlinear regime in future studies, a nonlinear interface evolution equation is derived, and the stability analysis is performed based on the evolution equation. Among the parameters studies are the ratios of the fluid densities and layer thicknesses and the net flow rate.

The Vertical Corporate Campus: Integrating Modern Workplace Models into the High-Rise Typology

  • Britton, John;Hargis, Steve
    • 국제초고층학회논문집
    • /
    • 제5권2호
    • /
    • pp.127-136
    • /
    • 2016
  • As the great urban migration continues to drive the growth of cities worldwide, global companies are seeking new approaches to the urban workplace and corporate campus. In light of environmental and economic imperatives to develop taller and denser central business districts, a key challenge is merging contemporary workplace concepts, which emphasize large, open floors and high levels of connectivity, with high-rise typologies with smaller floor plates set around center cores. This paper traces the evolution of the corporate campus and emerging design strategies for translating contemporary workplace models into a vertical campus typology that allows companies to realize the benefits of urban locations, while contributing to a more sustainable future.

Horizontal pullout capacity of a group of two vertical plate anchors in clay

  • Bhattacharya, Paramita;Kumar, Jyant
    • Geomechanics and Engineering
    • /
    • 제5권4호
    • /
    • pp.299-312
    • /
    • 2013
  • The horizontal pullout capacity of a group of two vertical strip plate anchors, placed along the same vertical plane, in a fully cohesive soil has been computed by using the lower bound finite element limit analysis. The effect of spacing between the plate anchors on the magnitude of total group failure load ($P_{uT}$) has been evaluated. An increase of soil cohesion with depth has also been incorporated in the analysis. For a weightless medium, the total pullout resistance of the group becomes maximum corresponding to a certain optimum spacing between the anchor plates which has been found to vary generally between 0.5B and B; where B is the width of the anchor plate. As compared to a single plate anchor, the increase in the pullout resistance for a group of two anchors becomes greater at a higher embedment ratio. The effect of soil unit weight has also been analyzed. It is noted that the interference effect on the pullout resistance increases further with an increase in the unit weight of soil mass.