• Title/Summary/Keyword: Variation Source

Search Result 1,341, Processing Time 0.031 seconds

A new X-ray cross-sectional image system for solder joint inspection of double-sided PCB (양면 PCB의 납땜부 검사를 위한 새로운 X선 단층영상 시스템)

  • 강성택;정재훈;조형석
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.117-120
    • /
    • 1996
  • In this paper, a new approach to acquire the cross-sentional image for automatic solder joint inspection of double-sided PCB using X-ray source is presented. We designed the apparatus with fixed X-ray source to realize the cross-sectional image by tunning object and detector synchronously. The cross-sectional images are captured at several view angle of X-ray source, the geometric image distortions caused by view angle and the shape of image intensifier are compensated. The precision variation of cross-sectional image by the change of view angle was investigated. Also we acquired the cross-sectional image to the solder joint of double-sided PCB and reconstructed the shape of solder joint.

  • PDF

Variation of Radiation Impedance for Piston Source According to Baffle

  • Park, Soon-Jong;Kim, Moo-Joon;Kim, Chun-Duck
    • The Journal of the Acoustical Society of Korea
    • /
    • v.20 no.2E
    • /
    • pp.46-50
    • /
    • 2001
  • The characteristics of radiation impedance are analyzed by algorithms which consists of Finite Element Method (FEM) and Hybrid type Infinite Element Method. The changes of radiation impedance for piston source according to the size and the material properties of baffles are studied. The results of the radiation impedance for rigid finite baffle coincide with other reports. The more the material properties of baffle that comes across the acoustic medium, the more the calculation results of radiation impedance approach the ones without baffle. Therefore, these results can be applied to the design and the radiation characteristics analysis of acoustic transducers.

  • PDF

질소원의 종류 및 초기 당농도가 곰팡이 Thraustochytrium aureum ATCC 34304의 성장 및 발효 특성에 미치는 영향

  • Kim, Won-Ho;Heo, Byeong-Gi
    • 한국생물공학회:학술대회논문집
    • /
    • 2000.11a
    • /
    • pp.313-316
    • /
    • 2000
  • The effects of initial sugar concentration and the various nitrogen sources on the fermentation characteristics of Thraustochytrium aureum were investigated. The sugar conversion ratios decrease with increase in the initial sugar concentration regardless of the kinds of nitrogen sources. The specific growth rate, the biomass yield, and the DHA yield also decreased but approached constant values higher than the concentration of 30g/L. The sugar conversion ratios and the specific growth rate showed the highest values in case of using the yeast extract as nitrogen source. It was difficult to conclude that the variation of nitrogen source had some effects on the biomass yield. However, the initial sugar concentration had a rather effects on the biomass yield for the sugar concentration of 40 g/L showed 0.27. The nitrogen source that showed the greatest yield of DHA was sodium glutamate.

  • PDF

EVALUATION OF THE UNCERTAINTIES IN THE MODELING AND SOURCE DISTRIBUTION FOR PRESSURE VESSEL NEUTRON FLUENCE CALCULATIONS

  • Kim, Yong-Il;Hwang, Hae-Ryong
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.3
    • /
    • pp.237-241
    • /
    • 2001
  • The uncertainties associated with fluence calculation at the pressure vessel have been evaluated for the Korean Next Generation Reactor, APR1400. To obtain uncertainties, sensitivity analyses were performed for each of the parameters important to calculated fast neutron fluence. Among the important parameters to the overall uncertainties, reactor modeling and core neutron source were examined. Mechanical tolerances, composition and density variations in the reactor materials as well as application of $r-{\theta}$ geometry in rectilinear region contribute to uncertainty in the reactor modeling. Depletion and buildup of fissile nuclides, instrument error related to core power level, uncertainty of fuel pin burnup, and variation of long-term axial peaking factors are main contributors to the core neutron source uncertainty. The sensitivity analyses have shown that the uncertainty in the fluence calculation at the reactor pressure vessel is +12%.

  • PDF

Calibration of $^{192}Ir$ HDR Brachytherapy Source in Air and in a Cylindrical Phantom

  • Djarwani S. Soejoko;I, Arief-Riva'
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.23-27
    • /
    • 2002
  • Two $^{192}$ Ir HDR brachytherapy sources were calibrated with a Farmer ionization chamber in air method and in a PMMA cylindrical phantom. The calibration air method used ionization chamber with buildup cap, and 8 variation distances for center-to-center of the source to chamber. In the optimum distance the measured activity, especially for the high activity source, deviation was 0.3% from the activity provided by manufacturer. Calibration with a PMMA cylindrical phantom was less sensitive, and suitable for quick check method with accuracy less than 10%.

  • PDF

A Study on the Stabilization Scheme of Optical Source for Precision Measurement (정밀측정을 위한 안정된 광원에 관한 연구)

  • 김지대;서호성;이동주
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2003.04a
    • /
    • pp.265-271
    • /
    • 2003
  • This study is for the stable optical source in order to get the precision measurement, which contributes to help the laser frequency and the output to be settled. The laser optical frequency is changed by the length of resonance cavity. The length variation of the laser resonance amplitude is affected by the thermal expansion of that system. So, we try not only to adjust the temperature of the laser tube using the heater for fine length of resonance cavity, but also to maintain the fixed temperature of the resonance cavity for outputting the safe laser optical frequency. Therefore, we must take materials with the thermal expansion of the supporting system, which is closer to it of the laser resonance cavity. Using the materials, we can promote to stabilize the temperature of it. In advance, we also plan to get the settlement of the laser frequency and the output in the long km, optimizing and stabilizing the system.

  • PDF

Environmental Pollutants Drained From Highway Pavement Road

  • Takemura, Shinsaku;Goto, Naoshige;Mitamura, Osamu
    • Korean Journal of Ecology and Environment
    • /
    • v.38 no.spc
    • /
    • pp.58-61
    • /
    • 2005
  • Environmental polluting materials from road surface drainage are a significant nonpoint source influenced to the eutrophication of lake and ecosystems with a transport development in recent years. To elucidate the discharge characteristics, the changing patterns in concentrations of polluting materials such as suspended solid (SS), chemical oxygen demand (COD), nitrogenous and phosphorus nutrients in drainage waters, were investigated during rainfall. Load variation of COD concentration in drainage water samples was closely related to that of SS concentration. This indicates that SS contained a greater part of organic matter. A quite difference between the past pavement and the new well-drainage pavement system was observed in the concentrations of SS and COD in drainage waters. Appreciable concentrations of nitrite and nitrate were determined in drainage waters. The present results indicate that the drainage water from road surfaces is a significant nonpoint source, and that the well-drainage pavement system introduced to skid prevention has an effect on the decreases of pollutants.

Voltage Source Finite Element Analysis of Electrical Machines Considering Hysteresis Characteristics (히스테리시스를 고려한 전기기기의 전압원 유한요소 해석)

  • Lee, Seok-Hee;Kim, Hong-Kyu;Jung, Hyun-Kyo;Hong, Sun-Ki
    • Proceedings of the KIEE Conference
    • /
    • 1999.07a
    • /
    • pp.203-205
    • /
    • 1999
  • In this paper, voltage source FEA considering magnetic hysteresis characteristics is presented. Magnetization dependent model is used as a hysteresis model. The unknowns in finite element equation are the magnetic vector potential and current. Core model is analyzed and current waveform is compared with the experimental one. It is found that current can be accurately predicted with the voltage variation.

  • PDF

The verification of Luminous flux of Reference illuminant for New light source by the calculated correction factor (보정계수 산출에 의한 신광원용 표준램프 광속의 검증)

  • Hwang, Myung-Keun;Shin, Sang-Wuk;Yi, Chin-Woo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.2
    • /
    • pp.369-372
    • /
    • 2009
  • When measuring the luminous flux of a light source at the integrating sphere photometer, it can know the luminous flux to compare the standard lamp with the specimen lamp at the same location. But in case of PLS(plasma lighting system, microwave discharged lamp), that two lamps are cannot be the same location. If the reference illuminant and specimen lamp are cannot measure identical location, we should measure the variation of the luminous flux. For the outcome we can turn out a correction factor to revise and reflect it. But the better way is calibrate the specimen lamp locate the identical location of reference illuminant measured. In this thesis, we've test to find the correction factor for consider that change the measuring location. And it turns out the correction factor. From this, it presents the result to make a select for the reference illuminant which is against the illuminant type for newly produce.

Electrical and Optical Properties of In-doped CdS Films Prepared by Vacuum Evaporation (진공증착법으로 제조한 CdS:In 박막의 전기 및 광학적 특성)

  • 김시열;임호빈
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1992.05a
    • /
    • pp.101-104
    • /
    • 1992
  • In-doped CdS thin films have been deposited at 150$^{\circ}C$ by simultaneous thermal evaporation of CdS and In. Deposition rate and film thickness were 8A/sec and about 1um, respectively. Indium doping concentration of films varied as Indium source temperature from 500$^{\circ}C$ to 700˚. Properties of In-CdS films have been investigatied by measurements of electrical resistivity, Hall effect, X-ray diffraction and optical trasmission spectra. The conductivity of these films was always n-type. The resistivity, carrier concentration, mobility and optical band gap dependence on Indium source temperature are reported. Carrier concentration and mobility of In-CdS films increased with increasing Indium source temperature: then they decreased. The variation of the optical band gap of In-CdS thin films are related to carrier concentration.

  • PDF