Study for Fire Examples of LPG Leakage Including Fuel hose, Injector and Pressure Regulator Connector in Vehicle (자동차 연료호스, 인젝터 및 압력조절기 연결부에서 LP 가스 누출에 의한 화재사례 고찰)

  • Lee, Il Kwon;Kook, Chang Hoo;Suh, Moon Won;Jung, Dong Hwa
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.3
    • /
    • pp.8-13
    • /
    • 2013
  • The purpose of this paper is to study for fire example by fuel leakage in LPG Vehicle. At first example, the car was repaired the fuel line that was connected with pressure hose between fuel regulator and injector in engine. But the service man was not very tighten with regular torque. At a result, the gas leaked on hot parts of engine. It verified the production of fire by engine heat. At second example, when the repair man, after replacement the injector, inserted the injector in a assembling part of it, he didn't the transform condition of fixing part. Therefore, the tearing phenomenon of O ring producted the controlled leakage of fuel by the injector deflection. It found the fact that the fuel leaked with gap of O ring. At third example. the fuel-cut solenoid valve was lined with pressure regulator unit. But the service man didn't throughly certify the leaked work of connected parts after repaired it. As a result, it certified the fire by engine heating leaked liquefied petroleum gas. Therefore it have to minimize the fire production that the driver should do no problem to throughly manage the fuel system.

A Study on the Development of IoT Inspection System for Gas Leakage Inspection in Kitchen Gas Range Built-in Method (주방 가스레인지 빌트인 방식에서 가스 누출검사를 위한 IoT 검사 시스템 개발에 관한 연구)

  • Kang, Dae Guk;Choi, Young Gyu
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.15 no.4
    • /
    • pp.283-290
    • /
    • 2022
  • In this study, an IoT inspection system that can be linked with a server was developed using a gas timer and ESP-01 Wi-Fi module installed on a gas valve in the home. The server environment of the gas leak IoT inspection system was installed with APM (Apache, PHP, MySQL) to collect gas pressure data by generation so that leakage checks could be performed. In order to control the gas leak IoT inspection system, the app inventory was used to manage the gas leak check value in real time. In addition, user convenience has been enhanced so that membership management, WiFi settings, and leakage check values can be checked through mobile apps. In order to manage subscribers by region, the user list was checked by logging in in in the administrator mode so that the information on whether or not the leak test was conducted and the results could be provided. In addition, when the user presses the gas leak check button, the pressure is automatically checked, and the measured value is stored in the server, and when a gas leak occurs, the leakage check is performed after alarm and repair so that it can be used if normal. In addition, in order to prevent overlapping membership, membership management can be performed based on MAC addresses.

Study for Failure Cases on Engine Electronic Control Computer in Liquid Petroleum Gas vehicle (액화석유가스 자동차 엔진의 전자제어 컴퓨터의 고장사례 연구)

  • Lee, Il-Kwon;Kim, Young-Gyu;Kook, Chang-Ho
    • Journal of the Korean Institute of Gas
    • /
    • v.15 no.6
    • /
    • pp.28-33
    • /
    • 2011
  • The purpose of this paper analyzes and studies to improve the failure cases on the computer that one of electronic control elements for engine in liquified petroleum gas vehicle. The first case, it certified the non-starting phenomenon of engine that it's electronic control unit didn't control the fuel for idle speed actuator because of no given action signal in slow-cut solenoid valve. The second case, it knew the bad condition phenomenon of engine and back-fire by the wire melting of ignition coil and firing of transistor being inside ECU. The third case, it certified the action stoping phenomenon of engine and malfunctioning signal for engine ECU because of leakage of current and an excess current by moisture inflowing inside ECU curcuit plate. Therefore, it is thought that will elevate the durability and reliability of engine computer throughout procure of quality.

Study on the performance improvement of a Main Oxidizer shut-off Valve (CC 산화제 개폐밸브 성능향상에 관한 연구)

  • Bae, Young-Woo;Kim, Do-Hyung;Hong, Moon-Geun;Lee, Soo-Yong;Jang, Ki-Won
    • Aerospace Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.63-72
    • /
    • 2010
  • MOV(Main Oxidizer shut-off Valves) control the combustion of launch vehicle systems by the supply and the isolation of liquid oxygen to a main combustion chamber in launch vehicle systems. Moreover, the MOV should secure a constant flow rate of liquid oxygen for combustion instability in the steady operational state. Although it has been showed that a EM(Engineering Model) with a high discharge coefficient value compared with the TM(Technology Model) fills the overall performance requirements, additional design modifications in some critical parts of the EM were conducted to improve the performance. The configurations of the pressure-control body, the middle flange, and the rips of the inlet body of the EM were modified and the performance tests have been performed with test models. Consequently, the intended improvements have been verified by the performance tests.

Improvement of Oil Seal Geometry to Improve Durability of Lateral Damper of Electric Multiple Unit (전동차 횡댐퍼 내구성 향상을 위한 오일씰 형상 개선)

  • Kim, Yong Wook;Koo, Jeong Seo
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.4
    • /
    • pp.90-97
    • /
    • 2018
  • As the result(also after it's been carried out the damping force test with 800ea lateral dampers of 50ea trainset from entering heavy maintenance workshop to implement heavy maintenance inspection cycle, there were 86.25%(650ea) which were out of $350kg{\pm}15%$ of the standard value of damping force compared to the reference value. After the implementation of heavy maintenance inspection cycle, it's been examined damping force test with total samples 32ea(samples 8ea per a trainset) from actual running EMU 4ea trainset. As the result, percent defective was 84.4%(27ea), which was a very high level. System. The lateral damper's the failure cause of damping force defective was oil leakage caused by tearing crack of oil seal and foreign material in oil iron 473 ~ 1932 times higher than that of new oil, copper 36 ~ 98 times higher than that of new oil reduced oil amount cycling damping valve. It resulted from the change cause of damping force. In the static analysis on the shape of lateral damper oil seal's the existing and improved product, the stress of the improved product was smaller than that of the existing product. In the fatigue analysis, the existing product showed a low life in the upper area. However, in case of the improved product, it could be confirmed that the destruction did not occur up to the specified 1.0e + 006 cycles and the lifetime was further improved in most areas.

Analysis of Ventilation Performance of PCVD Facility for Solar Cell Manufacturing (Explosion Prevention Aspect) (태양전지 제조용 PCVD설비의 환기 성능 분석(폭발 방지 측면))

  • Lee, Seoung-Sam;An, Hyeong-hwan
    • Journal of the Korean Institute of Gas
    • /
    • v.26 no.5
    • /
    • pp.35-40
    • /
    • 2022
  • PCVD (Plasma Chemical Vapor Deposition), a solar cell manufacturing facility, is a facility that deposits plasma generated in a chamber (NH3, SIH4, O2 on a wafer. In the PCVD facility, gas movement and injection is performed in the gas cabinet, and there are many leak points inside because MFC, regulator, valve, pipe, etc. are intricately connected. In order to prevent explosion in case of leakage of NH3 with an upper explosive limit (UEL) of 33.6% and a lower explosive limit (LEL) of 15%, the dilution capacity must be capable of allowing the concentration of NH3 to be out of the explosive range. This study was analyzed using the CFD analysis technique, which can confirm the dilution ability in 3D and numerical values when NH3 gas leaks from the existing PCVD gas cabinet. As a result, it was concluded that it corresponds to medium dilution and that testicular ventilation is possible through facility improvement.

Short Term Clinical Experiences of 52 Sorin Bicarbon Mechanical Valves (Sorin Bicarbon 기계판막의 단기 임상성적)

  • Lee, Cheol-Joo;Choi, Ho;Kim, Jung-Tai;Soh, Dong-Moon;Roh, Hwan-Kyu;Han, Jeong-Seon
    • Journal of Chest Surgery
    • /
    • v.31 no.7
    • /
    • pp.679-683
    • /
    • 1998
  • From June 1995 to May 1997, we have implanted 52 Sorin Bicarbon mechanical valves in 41 patients. They were 16 men and 25 women, and their mean age was 47.4${\pm}$14.8(range; 18∼74 y.o.). 35(27 mm∼31 mm) were in mitral position, 15(19 mm∼25 mm) in aortic position, and 2(31 mm) in tricuspid position. 3 CABGs and a tumor excision were taken concomittantly. 35 patients were primary operation, and 6 were re-do operations. By intraoperative transesophageal doppler echocardiography, transvalvular peak/mean pressure gradient was 6.1${\pm}$2.7/2.4${\pm}$1.4 mmHg in mitral position and 27.6/10.7 mmHg in aortic position. The effective valve opening area in mitral position was 3.2${\pm}$0.6 cm2. Follow-up was total 508.6 patient-months, and mean follw-up was 12.7${\pm}$9.2 months. NYHA class was improved from 2.6${\pm}$0.6 to 1.2${\pm}$0.3 in average postoperatively. During that period, there was no operative death. 2 late non-valve related deaths were occurred. One was died of COPD, and the other was possible acute myocardial infarction. Among 7 postoperative complications, one valve related complication(minimal paravalvular leakage) was noticed. In conclusion, Sorin Bicarbon mechanical valve is believed one of the safe choice in clinical settings. It showed excellent hemodynamic and mechanical functions, and very low postoperative valve related complications in short term clinical experience.

  • PDF

Home Security System Based on IoT (IoT 기반 홈 보안 시스템)

  • Kim, Kang-Chul;Wang, Ding-Hua;Han, Seok-Bung
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.12 no.1
    • /
    • pp.147-154
    • /
    • 2017
  • This paper aims to build a home security system based on IoT to monitor a home on a mobile phone. The system consists of data gathering sensors, camera, gateway and Xively platform. The Raspberry Pi collects data from the three sensors and sends the data to Xively, and sends the video stream of home to a client in a smart phone through a internet. The servers are composed of Xively, socket server in Raspberry Pi and E-mail server in Google. The proposed system transmits e-mail, text message, and video stream when there are motion, fire, and gas leakage, and can control the gas valve through Raspberry Pi. The experimental results show that a user gets 'emergency E-mail' and text message and watches the video stream of the home through WIFI or LTE on a smart phone.

SIS Design for Fuel Gas Supply System of Dual Fuel Engine based on Safety Integrity Level(SIL) (이중연료엔진의 연료가스공급시스템에 대한 안전무결도 기반 안전계장시스템 설계)

  • Kang, Nak-Won;Park, Jae-Hong;Choung, Choung-Ho;Na, Seong
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.49 no.6
    • /
    • pp.447-460
    • /
    • 2012
  • In this study, the shutdown system of the fuel gas supply system is designed based on the Safety Integrity Level of IEC 61508 and IEC 61511. First of all, the individual risk($10^{-4}$/year) and the risk matrix which are the risk acceptance criteria are set up for the qualitative risk assessment such as the HAZOP study. The natural gas leakage at the gas supply pipe is identified as the highest risk among the hazards identified through the HAZOP study and as a safety instrumented function the shutdown function for leakage was defined. SIL 2 and PFD($2.5{\cdot}10^{-3}$) for the shutdown function are determined by the layer of protection analysis(LOPA). The shutdown system(SIS) carrying out the shutdown function(SIF) is verified and designed according to qualitative and quantitative requirements of IEC 61508 and IEC 61511. As a result of SIL verification and SIS conceptual design, the shutdown system is composed of two gas detectors voted 1oo2, one programmable logic solver, and two shutdown valve voted 1oo2.

Validity of solar energy generation at the underused Space of LPG filling station (LPG충전소 유휴공간의 태양광발전설비 설치 유효성)

  • Lee, Minkyung;Kim, Jeonghwan;Lee, Jinhan;Joe, Youngdo;Lee, Yeonjae
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.4
    • /
    • pp.25-32
    • /
    • 2016
  • The purpose of this study is safety evaluation of solar energy generation which is installed on the canopy at the LPG filling station. in case of a gas station, the solar energy generation was become legalization through a related law reform in 2008. Also, in case of a LPG filling station, the solar energy generation was become legalization through a related law reform in 2015. So, the related law that KGS CODE and Safety control of dangerous substances law and the case of installed solar energy generation in gas, LPG filling station was investigated. two scenarios are supposed for the CFD. Release of safety valve pipeline and ruptured dispenser leakage are the scenarios. The FLACS which developed GexCon in Norway was used for simulation. LPG dispersion to the upper side of canopy was very small with safety distance.