• Title/Summary/Keyword: Valve Displacement

Search Result 204, Processing Time 0.025 seconds

Advanced Pressure Control of Piezoelectric Valve on Electro-hydraulic Braking (피에조밸브를 적용한 전자유압브레이크의 압력제어)

  • DocKo, Jong-Hun;Park, Gwi-Tae
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1576-1577
    • /
    • 2007
  • As a intelligent valve piezoelectric valve is to applied to various fields of application. Piezoelectric valves have fast response time and good linearity for pressure control but its hysteresis displacement by its stack actuator influences on pressure control in electro-hydraulic braking. Solenoid valves are traditional element to control hydraulic pressure but this paper proposes piezoelectric valve for brake pressure control with hysteresis compensation.

  • PDF

Optimum Cam Profile Design and Experimental Verification on an OHC Type Cam-valve System (OHC형 캠-밸브 기구의 최적 캠 형상설계 및 실험적 검증)

  • 김성훈;김원경;박윤식
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.11
    • /
    • pp.2049-2058
    • /
    • 1992
  • In this work, a 6 degree of freedom lumped mass model is constructed for an OHC-type cam valve train analysis, and the model is verified experimentally. Using the verified model, an optimum cam profile is designed to minimize the maximum contact force between cam and follower under the constraints such as cam lift and cam event angle. The designed cam was carefully machined and tested experimentally. As operating the designed cam shaft on the test rig, the valve motion was precisely measured with laser displacement meter and the contact force was indirectly monitored by measuring strain at a certain point of the finger follower. Judging from the model simulation and experiment results, the maximum contact force can be reduced as much as more than 16.7 percent under maintaining the original valve flow area by adopting the optimum cam profile.

Analysis of the Mechanical Behavior of Bellows for Electromagnetic Control Valve (전자기 제어 밸브를 위한 벨로우즈의 기계적 거동에 관한 연구)

  • Son, In-Seo;Hwang, Seon;Shin, Dong-Kil
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.3
    • /
    • pp.432-437
    • /
    • 2016
  • The behavior of a bellows for an electromagnetic control valve was investigated. The bellows consists of an outer metal bellows, inner spring, and metal caps. The bellows needs to have sensitive and precise motion against external loads and pressure loads in order to control the position of the valve accurately. The spring constant of the inner spring and load-displacement curve of the bellows set were measured using a test machine. The inner spring showed a linear relation between load and displacement. The bellows set showed small stiffness at small displacement, and then the stiffness slightly increased upon subsequent displacement. Based on the measured data, finite element analysis was performed. Axisymmetric conditions were applied, and shell elements were used. The effective material properties of the outer bellows material were extracted. Additional analysis was performed, and the behavior of the bellows was analyzed using the finite element model.

Displacement Control of Pneumatic Actuator Equipped with PLC and Proximity Sensors (PLC와 근접센서를 이용한 공압 실린더의 변위제어)

  • Kim, Gun-Hoi;So, Jung-Duck
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.17 no.2
    • /
    • pp.90-96
    • /
    • 2008
  • A pneumatic system was proposed to evaluate displacement accuracy of the pneumatic actuator without external load and to analyze capability of integration of the proposed valve system. The proposed pneumatic system consisted of a combination of pneumatic valves, two proximity sensors, and a programmable logic controller(PLC). The position controller is based on the PLC controller connected with the proximity sensors. Displacement accuracy of the pneumatic cylinder stroke was tested by varying air pressures of the supply and discharge-side and strokes of the pneumatic cylinder. The displacement accuracy of the pneumatic cylinder stroke increased as the supply and discharge side of air pressure increased at the stroke length of 133mm. Also the displacement accuracy increased as the stroke length increased with a fixed supply and discharge side of air pressure of the pneumatic cylinder as 3.5 and $4.5kg/cm^2$, respectively. The most accurate displacement of the pneumatic cylinder(i.e., standard deviation of 0.01 mm) was obtained at the supply and discharge side of air pressure of 4.0 and $5.0kg/cm^2$, respectively, and strokes of 170 and 190 mm among arbitrarily selected supply and discharge side air pressures and strokes.

Evaluation of Design Safety for Butterfly Valve (버터플라이 밸브의 설계 안전도 평가)

  • Lee, Seung-Pyo;Kim, Kwang-Suk;Koh, Byung-Kab
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.18 no.1
    • /
    • pp.29-35
    • /
    • 2009
  • Butterfly valve is a kind of rotational valve which opens and closes the flow of fluid on rotating the disk 90 degrees in the valve body. In this paper, butterfly valve design safety evaluation which is based on the international valve specifications is investigated. Both body and disk of the butterfly valve are considered under the normal and pressurized operating conditions. A finite element analysis is carried out to compute the distribution of the displacement, stress and safety factor by using ANSYS. On the basis of calculated design safety we offer the design modification and compare with them.

A Numerical Analysis on the Motion of Mechanical Heart Valve(MHV) and Characteristics of Blood Flow in an Elastic Blood Vessel (탄성혈관 내 기계식 인공심장판막(MHV)의 거동 및 혈액 유동 특성에 관한 수치해석적 연구)

  • Bang Jin-Seok;Choi Choeng-Ryul;Kim Chang-Nyung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.3 s.168
    • /
    • pp.154-161
    • /
    • 2005
  • In this study, the leaflet motion of a mechanical heart valve and the characteristics of two-dimensional transient blood flow in an elastic blood vessel have been numerically investigated by using fluid-structure interaction method. Here, blood has been assumed as a Newtonian, incompressible fluid. Pressure profiles have been used as boundary conditions at the ventricle and the aorta. As a result, closing motion of the leaflet is faster than opening one. While opening angles of leaflet grow up, vortex is detected at the sinus and backward of the leaflets. When the leaflet is fully closed, vortex is detected at the ventricle and at that moment maximum displacement of the elastic blood vessel is observed in the vicinity of the sinus region. Maximum displacement is caused in association with the blood flow that is oriented toward the elastic blood vessel.

Study of the Fluid Flow on Proportional Valve in Spool Displacement using CFD

  • Li, Kui-Ming;Choi, Yoon-Hwan;Lee, Ill-Yeong;Lee, Yeon-Won
    • Journal of Power System Engineering
    • /
    • v.19 no.2
    • /
    • pp.22-26
    • /
    • 2015
  • The main objective of this work is to estimate the fluid flow of a proportional valve. The study is based on the classical compressible flow theory and the computations with the help of CFD based commercial software - ANSYS CFX. The fluid flow with the movement of spool along the sleeve is simulated. To change the spool moving from 0.4mm to 2.0mm, the moving mesh method with different condition of orifice is considered here. The results show that it is the highest at the 80 % (1.6mm) opening and at the 20 % (0.4mm) opening, is the lowest.

Dynamic Characteristics of Clutch System for an Automatic Transmission (자동변속기 클러치 시스템의 동특성 해석)

  • Kim, Ju Hwan;Kim, Hyun-Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.1
    • /
    • pp.284-294
    • /
    • 1996
  • In this paper, dynamic characteristics of an AT clutch system were investigated considering the dynamics of check ball and hydraulic control valves. Dynamic model of a pressure control solenoid valve (PCSV) was obtained by Bondgraph and permeance method. Also, the clutch piston and check ball dynamics were modeled by considering the effect of centrifugal force of the oil entrapped in the clutch chamber. In order to validate the dynamic models obtained, plunger displacement of PCSV and pressure response of the clutch supply lines were compared with the available experimental data, which were in good accordance with the numerical results. Using the dynamic model of the clutch system, simulations were performed to investigate the effect of the rotational speed on the response of clutch cylinder pressure, clutch piston and check ball displacement, and oil flow rate into the cylinder and flow rate out of the check valve.

Performance Evaluation of a Semi-active Vehicle Suspension Using Piezostack Actuator Valve (압전작동기 밸브를 이용한 반능동 차량현가장치의 성능 고찰)

  • Han, Chulhee;Yoon, Gun-Ha;Park, Young-Dai;Choi, Seung-Bok
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.26 no.1
    • /
    • pp.82-88
    • /
    • 2016
  • This paper proposes a new type of semi-active direct-drive valve(DDV) car suspension system using piezoelectric actuator associated with displacement amplifier. As a first step, controllable piezoelectric DDV damper is designed and governing equation of a quarter-vehicle suspension system consisting of sprung mass, spring, tire and the piezostack DDV damper is constructed. After deriving the equations of the motion, in order to control spool displacement and damping force the skyhook controller is designed and applied. The performance evaluation of the proposed semi-active suspension system is conducted with different displacement of spool. Then, the ride comfort analysis is undertaken in time domain with bump road profile.

A Study on the Bandwidth Frequency of Directional Control Valves based on the Amplitude of the Metering-Orifice Pressure (미터링 오리피스 압력 진폭을 이용한 방향제어밸브 대역폭 주파수에 관한 연구)

  • Kim, Sungdong;Jeon, Sehyeong;Shin, Daeyoung
    • Journal of Drive and Control
    • /
    • v.14 no.2
    • /
    • pp.1-8
    • /
    • 2017
  • The spool displacement of a directional control valve can be considered as the standard signal for the measurement of its bandwidth frequency. When the spool displacement is not available, the metering-orifice system is suggested in this study as an alternative way to measure the - 3 dB amplitude-ratio bandwidth frequency of the hydraulic directional-control valve. The amplitude ratio of the metering-orifice pressure can be adjusted to equal that of the spool displacement through the controlling of the metering-orifice opening area. A series of experiments were conducted to verify the effectiveness of the metering-orifice system. The metering orifice was confirmed as adequate for the measurement of the - 3 dB amplitude-ratio bandwidth frequency.