• Title/Summary/Keyword: Value Curve

Search Result 2,052, Processing Time 0.03 seconds

Prediction of Stress-strain Behavior for Anisotropic Consolidated Compacted Decomposed Granite Soil (비등방 압밀된 다짐화강풍화토의 응력-변형률 거동 예측)

  • 정진섭;양재혁
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.45 no.2
    • /
    • pp.86-95
    • /
    • 2003
  • During this study, constant stress ratio tests with previous compression anisotropic stress history are performed on compacted decomposed granite soil sampled at Iksan, Jeonbuk. Yielding points are determined from stress-strain curves. The shape and characteristics of compression anisotropic yield curves is examined. In addition, the measured value of yielding curve and stress-strain behavior is predicted by Yasufuku's anisotropic constitutive model based on non-associated flow rule. The main results are summarized as follows : 1) Shape of yielding curves shows almost ellipse but asymmetry with respect to stress path during previous consolidation stress. 2) Yasufuku's anisotropic constitutive model is suitable in evaluation of yielding curves on anisotropic consolidated decomposed granite soil. 3) The predicted stress-strain curve shows reasonable agreement to measured behaviours.

Determination of Critical Nitrogen Concentration and Dilution Curve for Rice Growth

  • Lee, Byun-Woo;Cui, Ri-Xian;Kim, Min-Ho;Kim, Jun-Hwan;Nam, Hong-Shik
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.47 no.2
    • /
    • pp.127-131
    • /
    • 2002
  • Critical nitrogen concentration (Nc), which is defined as the minimum % N in shoots required to maintain the maximum growth rate of top dry weight (W) at any time, was determined for rice plant. Using two rice varietal groups, japonica varieties and an indica $\times$ japonica "Dasanbyeo", 18 data points fulfilling the statistical criteria for determining Nc were obtained through eight N-fertilization experiments over two years at Suwon (37$^{\circ}$16'N), Korea. Nc dilution curve for each variety was obtained by fitting the Nc-W relationship to power function. However, The critical nitrogen curves for the two variety groups were not different statistically. Thus, a Nc dilution curve was fitted for the Nc data points pooled over the two variety groups and proposed in rice as: Nc=4.08, where W<1.73 t h $a^{-1}$ , Nc=5.197 $W^{0.425}$3/ ($R^2$=0.964), where 1.73 t h $a^{-1}$ <W<12 t h $a^{-l}$. The Nc for W<1.73 t h $a^{-l}$ were estimated as a constant value of 4.08%, the mean value of the maximum N concentration for N-limiting condition and the minimum N concentration for N non-limiting condition. The model for Nc is applicable to diagnosing the nitrogen nutrition status during the rice growth period from emergence to heading stage. The Nc curve well discriminated the 144 data points between the N limiting and the N non-limiting groups regardless of varieties, cultural methods, and years.-limiting groups regardless of varieties, cultural methods, and years.

Radiologic Analysis of Cervical Lordosis for University Students (대학생들의 경추의 전만 각도에 대한 고찰)

  • Cho, Dong-In;Yoon, Jeong-won;Kim, Soon-Joong;Park, Dong-Su
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.25 no.4
    • /
    • pp.83-92
    • /
    • 2015
  • Objectives To measure and analyze the curvature of the cervical spine for university students. Methods This study carried out on 132 students. The cervical spine curvature was measured by six measuring methods. The type and numeric value of cervical spine curvature was analyzed by Angle of cervical curve (C1~C7), Angle of cervical curve (C2~C7), Jackson's angle, Ishihara Index, Depth of cervical curve and Method of Jochumsen. Cervical spine curvatures between male and female are compared by Mann-Whitney test. Rate of type of cervical curvature between male and female are compared by linear by linear association. Results 1. The average of angle of cervical curve (C1~C7) is $33.78{\pm}9.85^{\circ}$, angle of cervical curve (C2~C7) is $10.28{\pm}8.12^{\circ}$. The average of Jackson's angle is $14.02{\pm}10.01^{\circ}$, average of Ishihara Index is $8.46{\pm}10.58%$. The average of Depth of cervical curve is $5.15{\pm}4.72mm$ and average of Method of Jochumsen is $0.94{\pm}3.83mm$. 2. More than half of student's cervical curvature showed hypolordosis except Ishihara index. 3. There was significant difference in numeric value of cervical curvature between male and female both groups in terms of Ishihara index. 4. There were insignificant differences between male and female in terms of type of cervical curvature. Conclusions According to above results, we found out average of student's cervical curve. And the results suggest that most of the student's cervical curvature decrease.

Detection of Different Ratios of Gamma-irradiated Turmeric by Photostimulated Luminescence and Thermoluminescence (방사선 조사된 터머릭의 혼합비율에 따른 Photostimulated Luminescence 및 Thermoluminescence 분석 특성)

  • Lee, Ji-Ae;Chung, Hyung-Wook;Kwon, Joong-Ho
    • Korean Journal of Food Science and Technology
    • /
    • v.42 no.6
    • /
    • pp.648-652
    • /
    • 2010
  • This study was performed to investigate PSL and TL characteristics for the detection of different ratios of gamma-irradiated turmeric. It was possible to determine PSL and TL of 1- and 10-kGy irradiated turmeric. The TL ratios ($TL_1/TL_2$) of non-irradiated samples were lower than 0.001, while those of irradiated samples were higher than 0.355. In the PSL results, blended samples containing irradiated ingredients showed intermediate values for a 1% blending rate. Furthermore, TL analysis of blended samples seems to offer a promising method for irradiation identification by TL glow curve form and temperature range. The 1- and 10-kGy irradiated samples were able to be detected above a 4% blending rate. However, the TL ratio appeared as a threshold value below 0.1 for irradiated samples. Overall, TL analysis identified 4% blended samples containing gamma-irradiated turmeric.

Wedge Shape Cage in Posterior Lumbar Interbody Fusion : Focusing on Changes of Lordotic Curve

  • Kim, Joon-Seok;Oh, Seong-Hoon;Kim, Sung-Bum;Yi, Hyeong-Joong;Ko, Yong;Kim, Young-Soo
    • Journal of Korean Neurosurgical Society
    • /
    • v.38 no.4
    • /
    • pp.255-258
    • /
    • 2005
  • Objective : Lumbar lordotic curve on L4 to S1 level is important in maintaining spinal sagittal alignment. Although there has been no definite report in lordotic value, loss of lumbar lordotic curve may lead to pathologic change especially in degenerative lumbar disease. This study examines the changes of lumbar lordotic curve after posterior lumbar interbody fusion with wedge shape cage. Methods : We studied 45patients who had undergone posterior lumbar interbody fusion with wedge shape cage and screw fixation due to degenerative lumbar disease. Preoperative and postoperative lateral radiographs were taken and one independent observer measured the change of lordotic curve and height of intervertebral space where cages were placed. Segmental lordotic curve angle was measured by Cobb method. Height of intervertebral space was measured by averaging the sum of anterior, posterior, and midpoint interbody distance. Clinical outcome was assessed on Prolo scale at 1month of postoperative period. Results : Nineteen paired wedge shape cages were placed on L4-5 level and 6 paired same cages were inserted on L5-S1 level. Among them, 18patients showed increased segmental lordotic curve angle. Mean increased segmental lordotic curve angle after placing the wedge shape cages was $1.96^{\circ}$. Mean increased disc height was 3.21mm. No cases showed retropulsion of cage. The clinical success rate on Prolo's scale was 92.0%. Conclusion : Posterior lumbar interbody fusion with wedge shape cage provides increased lordotic curve, increased height of intervertebral space, and satisfactory clinical outcome in a short-term period.

A Conceptual Framework of IoT Case Study (IoT 사례분석을 위한 개념적 틀 제시)

  • Jeon, Ka Young;Lee, Jang Hyuk;Oh, Jungsuk
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.10 no.3
    • /
    • pp.123-131
    • /
    • 2015
  • With a prospective of rapid deployment of IOT, a systematic approach to derive a business strategy for various possible scenarios of IOT applications is in great demand. In this paper, a conceptual framework that can be utilized for the purpose of assessing the market potential and of setting up an initial business strategy for IOT deployment is suggested. The framework consists of utilization of well-known value curve analysis, ecosystem analysis and house of quality tools. The value curve analysis is utilized to identify value-enhancing components of consumers as well as relative strengths of suppliers. The ecosystem analysis is used to identify relevant players of the supply chain and their mutual relationships. The house of quality is suitable for developing the initial business strategy of the supplier by converting consumer requirements identified by value curve analysis into technical requirements for the supplier. In this paper, we applied our proposed framework to two services that have high potentiality of being benefited by IOT: car-sharing service and telehealth service.

  • PDF

PMP Estimation and Its Application for the Design Flood Determination in River Basin (하천유역의 설계 홍수량 결정을 위한 P.M.P.의 산정 및 적용)

  • 이순탁;박정규
    • Water for future
    • /
    • v.19 no.1
    • /
    • pp.75-86
    • /
    • 1986
  • This study aims at the analysis and application of PMP(Probable Maximum Precipitation)for the determination of design flood in the river basin planning and design of major hydraulic structures. PMP was estimated by hydro-meterological method statistical method and envelope curve method. PMF(Probable Maximum Flood)was then estimated from this PMP by synthetic unit hydrograph method and chow method. From the comparison of three methods for PMP estimation of magnitude of PMP in order of statistical, hydro-metrological, envelope curve method. Among PMP results estimated by each method it is believed that the hydro-meteorological method gave the best proper value in comparison with historical maximum rainfall because of this method reflected upon all meterological factor. From the comparison of PMP with probable rainfall and flood, it was shown that estimated value by statistical method and hydro-metrological method were nearly equivalent to the value of return period 100 years and its value of envelope curve method was equivalent to return period 200 to 500 year. It was found that PMF estimated from would be more safe for the design of major hydraulic structures in the consideration.

  • PDF

A Logistic Model Including Risk Factors for Lymph Node Metastasis Can Improve the Accuracy of Magnetic Resonance Imaging Diagnosis of Rectal Cancer

  • Ogawa, Shimpei;Itabashi, Michio;Hirosawa, Tomoichiro;Hashimoto, Takuzo;Bamba, Yoshiko;Kameoka, Shingo
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.2
    • /
    • pp.707-712
    • /
    • 2015
  • Background: To evaluate use of magnetic resonance imaging (MRI) and a logistic model including risk factors for lymph node metastasis for improved diagnosis. Materials and Methods: The subjects were 176 patients with rectal cancer who underwent preoperative MRI. The longest lymph node diameter was measured and a cut-off value for positive lymph node metastasis was established based on a receiver operating characteristic (ROC) curve. A logistic model was constructed based on MRI findings and risk factors for lymph node metastasis extracted from logistic-regression analysis. The diagnostic capabilities of MRI alone and those of the logistic model were compared using the area under the curve (AUC) of the ROC curve. Results: The cut-off value was a diameter of 5.47 mm. Diagnosis using MRI had an accuracy of 65.9%, sensitivity 73.5%, specificity 61.3%, positive predictive value (PPV) 62.9%, and negative predictive value (NPV) 72.2% [AUC: 0.6739 (95%CI: 0.6016-0.7388)]. Age (<59) (p=0.0163), pT (T3+T4) (p=0.0001), and BMI (<23.5) (p=0.0003) were extracted as independent risk factors for lymph node metastasis. Diagnosis using MRI with the logistic model had an accuracy of 75.0%, sensitivity 72.3%, specificity 77.4%, PPV 74.1%, and NPV 75.8% [AUC: 0.7853 (95%CI: 0.7098-0.8454)], showing a significantly improved diagnostic capacity using the logistic model (p=0.0002). Conclusions: A logistic model including risk factors for lymph node metastasis can improve the accuracy of MRI diagnosis of rectal cancer.

The operation properties of DBD reactors in air pressure with varying the capacitance of reactors (정전 용량변화에 따른 대기압 DBD 반응기의 동작 특성 연구)

  • 박봉경;김윤환;장봉철;조정현;김곤호
    • Journal of the Korean Vacuum Society
    • /
    • v.10 no.4
    • /
    • pp.440-448
    • /
    • 2001
  • The operation properties of DBD plasma reactors were observed by using 20 kV square pulse at the cylindrical and planar type of reactors in the condition of air pressure. The optimum operation frequency $f_0$ which optimizes the efficiency of operation was found as such $f_0\proptoexp(-C)$ when the current-voltage curve and charge-voltage curve were observed. Using these properties the dissipated power was evaluated. The dissipated power at the optimum frequency of operation was varied as the value of capacitance which is dependent on the structure and the dielectric material of the reactor, and had the maximum value at the specific value of capacitance. With these value of capacitance, DBD reactors which has a high level of efficiency can be formed.

  • PDF

Evaluating the Validity of the Pediatric Index of Mortality Ⅱ in the Intensive Care Units (소아중환자를 대상으로 한 PIM Ⅱ의 타당도 평가)

  • Kim, Jung-Soon;Boo, Sun-Joo
    • Journal of Korean Academy of Nursing
    • /
    • v.35 no.1
    • /
    • pp.47-55
    • /
    • 2005
  • Purpose: This study was to evaluate the validity of the Pediatric Index of Mortality Ⅱ(PIM Ⅱ). Method: The first values on PIM Ⅱ variables following ICU admission were collected from the patient's charts of 548 admissions retrospectively in three ICUs(medical, surgical, and neurosurgical) at P University Hospital and a cardiac ICU at D University Hospital in Busan from January 1, 2002 to December 31, 2003. Data was analyzed with the SPSSWIN 10.0 program for the descriptive statistics, correlation coefficient, standardized mortality ratio(SMR), validity index(sensitivity, specificity, positive predictive value, negative predictive value), and AUC of ROC curve. Result: The mortality rate was 10.9% (60 cases) and the predicted death rate was 9.5%. The correlation coefficient(r) between observed and expected death rates was .929(p<.01) and SMR was 1.15. Se, Sp, pPv, nPv, and the correct classification rate were .80, .96, .70, .98, and 94.0% respectively. In addition, areas under the curve (AUC) of the receiver operating characteristic(ROC) was 0.954 (95% CI=0.919~0.989). According to demographic characteristics, mortality was underestimated in the medical group and overestimated in the surgical group. In addition, the AUCs of ROC curve were generally high in all subgroups. Conclusion: The PIM Ⅱ showed a good, so it can be utilized for the subject hospital. better.