• 제목/요약/키워드: VSC

검색결과 275건 처리시간 0.022초

가변구조제어기와 인공 신경회로망에 의한 BLDC모터의 디지털 전류제어 (Digital current control for BLDC motor using variable structure controller and artificial neural network)

  • 박영배;김대준;최영규
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1997년도 한국자동제어학술회의논문집; 한국전력공사 서울연수원; 17-18 Oct. 1997
    • /
    • pp.504-507
    • /
    • 1997
  • It is well known that Variable Structure Controller(VSC) is robust to parameters variation and disturbance but its performance depends on the design parameters such as switching gain and slope of sliding surface. This paper proposes a more robust VSC that is composed of local VSC's. Each local VSC considers the local system dynamics with narrow parameter variation and disturbance. First we optimize the local VSC's by use of Evolution Strategy, and next we use Artificial Neural Network to generalize the local VSC's and construct the overall VSC in order to cover the whole range of parameter variation and disturbance. Simulation on BLDC motor current control shows that the proposed VSC is superior to the conventional VSC.

  • PDF

가변구조제어기를 이용한 BLDC 모터의 전류제어 (Variable Structure Current Controller for BLDC Motor)

  • 박영배;김대준;전향식;최영규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 B
    • /
    • pp.452-455
    • /
    • 1997
  • It is well known that Variable Structure Controller(VSC) is robust to parameters variation and disturbance but its performance depends on the design parameters such as switching gain and slope of sliding surface. This paper proposes a more robust VSC that is composed of local VSC's. Each local VSC considers the local system dynamics which has narrow parameter variation and disturbance. We optimize the local VSC's by use of Evolution Strategy, and then we use Artificial Neural Network to generalize the local VSC's and construct the overall VSC in order to cover the whole range of parameter variation and disturbance. Simulation on BLDC motor current control has verified the proposed VSC is superior to the conventional VSC.

  • PDF

동적신경망을 이용한 비선형 다변수 시스템의 제어기 설계 (Design of Controller for Nonlinear Multivariable System Using Dynamic Neural Unit)

  • 조현섭
    • 한국산학기술학회논문지
    • /
    • 제9권5호
    • /
    • pp.1178-1183
    • /
    • 2008
  • 슬라이딩 모드를 가진 가변 구조 제어(VSC)는 비선형 시스템의 현대제어에서 중요하고 흥미로운 주제이다. 그러나, VSC에서의 불연속적인 제어 법칙은 실제로 바람직하지 못한 떨림 현상을 발생시킨다. 본 논문에서는 이러한 문제점을 해결하기 위해 신경망 슬라이딩 곡면을 갖는 VSC 구조를 제안한다. 불연속 제어 법칙을 해결하기 위해 경계층을 가진 신경망 슬라이딩 곡면이 도입된다. 제안된 제어기는 보편적인 VSC의 떨림 현상 문제를 해결할 수 있다. 제안된 제어 구조의 효과는 시뮬레이션을 통해 증명하였다.

New design of variable structure control based on lightning search algorithm for nuclear reactor power system considering load-following operation

  • Elsisi, M.;Abdelfattah, H.
    • Nuclear Engineering and Technology
    • /
    • 제52권3호
    • /
    • pp.544-551
    • /
    • 2020
  • Reactor control is a standout amongst the most vital issues in the nuclear power plant. In this paper, the optimal design of variable structure controller (VSC) based on the lightning search algorithm (LSA) is proposed for a nuclear reactor power system. The LSA is a new optimization algorithm. It is used to find the optimal parameters of the VSC instead of the trial and error method or experts of the designer. The proposed algorithm is used for the tuning of the feedback gains and the sliding equation gains of the VSC to prove a good performance. Furthermore, the parameters of the VSC are tuned by the genetic algorithm (GA). Simulation tests are carried out to verify the performance and robustness of the proposed LSA-based VSC compared with GA-based VSC. The results prove the high performance and the superiority of VSC based on LSA compared with VSC based on GA.

VSC 유압유닛의 압력 추정기 및 제어기 설계에 관한 연구 (A Study on Estimator and Controller Design of VSC Hydraulic Unit)

  • 유승진;김범주;이교일
    • 유공압시스템학회논문집
    • /
    • 제2권4호
    • /
    • pp.7-13
    • /
    • 2005
  • This paper presents modeling and ostimator/controller design for the hydraulic system in Vehicle Stability Control(VSC) system. A nonlinear mathematical model of the VSC hydraulic system is proposed and its accuracy is experimentally verified. A brake pressure estimator is then designed based on the derived mathematical model of VSC hydraulic system. And a disturbance observer, which compensates the estimation error between the brake pressure and the computed brake pressure is also designed to enhance the accuracy of the estimator. The proposed controller has the form of a feedback controller and determines explicitly the on/off ratio of valves' driving PWM signals by means of making use of the simplified mathematical model in the VSC hydraulic system. The performance of the designed controller whose feedback signal is generated by the brake pressure estimator is validated through experimental results.

  • PDF

3-Level T-type Inverter Operation Method Using Level Change

  • Kim, Tae-Hun;Lee, Woo-Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권1호
    • /
    • pp.263-269
    • /
    • 2018
  • In this study, a selective inverter operation between a 2-level voltage source converter (VSC) and a 3-level T-type VSC (3LT VSC) is proposed to improve the efficiency of a 3LT VSC. The 3LT VSC topology, except for its neutral-point switches, has similar operations as that of the 2-level VSC. If an operation mode is changed according to efficiency, the efficiency can be improved because efficiencies of each methods are depending on current and MI (Modulation Index). The proposed method calculates the power losses of the two topologies and operates as the having lower losses. To calculate the losses, the switching and conduction losses based on the operation mode of each topology were analyzed. The controller determined the operation mode of the 2- or 3-level VSC based on the power loss calculated during every cycle. The validity of the proposed control scheme was investigated through simulation and experiments. The waveform and average efficiency of each method were compared.

MMC VSC-HVDC의 경제성평가에 관한 연구 (A Study on the Benefit Estimation of MMC VSC-HVDC System)

  • 선휘일;박성미;유동욱;박성준
    • 한국산업융합학회 논문집
    • /
    • 제23권1호
    • /
    • pp.65-71
    • /
    • 2020
  • Recently, interest in the DC transmission is rapidly increasing worldwide. In many countries and leading companies are prior to the aggressive development of HVDC technology and application. Especially, VSC-HVDC system has been widely applied to transfer power at long distance between power plant and power consumption area. Therefore in this paper, we analyzed the benefit-cost of VSC-HVDC system which has more advantages than existing transmission system. The proposed system is MMC(Modular Multilevel Converter) VSC-HVDC system that have stability of Power Grid, interconnect Large-scale New Power Generation Plants by prevents Blackout. And MMC VSC-HVDC system Reduced the loss importing foreign systems. And the benefits were calculated in four stages, and the costs were applied to the actual project. By evaluating the various avoidance costs compared to the benefit-cost, it was confirmed that MMC VSC-HVDC system was advantageous in system stability and economic and social benefits.

치주질환 치료 후 구취 감소에 대한 연구 (The Study of Malodor Reduction after Periodontal Treatment)

  • 이재명;임성빈;정진형;홍기석
    • Journal of Periodontal and Implant Science
    • /
    • 제34권2호
    • /
    • pp.449-459
    • /
    • 2004
  • Bacterial byproducts and volatile sulfur compounds(VSC) have been found to be the leading intra-oral agents, specifically, the byproducts of gram negative anaerobic bacteria have been implicated as primary factors of halitosis in patients presenting with periodontal disease. The objective of this study was to determine the correlation between periodontal treatment and the subsequent reduction in the level of halitosis. Forty-three subjects presenting with periodontal disease were examined before periodontal treatment, one week after treatment, one month after treatment, and finally, two months after treatment, using a portable sulfide monitoring $Halimeter^{(R)}$ to measure the VSC concentrations at the prescribed intervals. The results of the study were as follows: 1. Significant decreases in the mean VSC concentration were observed at the one week, one month, and two month post-op intervals relative to the pre-op measurement. (p<0.05) 2. Significant decreases in the mean VSC concentration were observed in subjects after completion of flap operations. Significant decreases in the mean VSC concentration were observed at the one and two month post-flap operation measurement relative to the VSC concentration at one week (p<0.05), but no significant differences between the one month and two month VSC concentrations were found. (p<0.05) 3. Significant decreases in the mean VSC concentration were observed in subjects after completion of subgingival curettage (p<0,05). Significant decreases were found between the one week and one month measurements and between the one month and two month measurements, but significant differences were not observed between the one week and two month measurements. (p<0.05) The results of this study show significant decreases in VSC concentration in test subjects after periodontal treatment. It can be inferred from the results above, that periodontal disease is a significant contributing factor of halitosis, and that treatment of periodontal disease can been an effective means of reducing VSC concentration in patients presenting with halitosis concurrent with periodontal disease.

제주 HVDC#3 영향 분석 (The Effect of HVDC#3 on Jeju Power System)

  • 박정수;정홍주;한영성;김래영;정정주
    • 전기학회논문지
    • /
    • 제60권12호
    • /
    • pp.2196-2201
    • /
    • 2011
  • According to the 5th national plan for electric power demand and supply, the 3rd HVDC link will be installed between KEPCO and Jeju Island system and go into operation in June, 2016. However, if it adopt LCC HVDC, Jeju power system could be in voltage instable condition. In order to solve the problem, we propose the application of VSC HVDC to the 3rd HVDC project. In the past, VSC HVDC has many disadvantages such as, inefficiency in conversion, size limit, and expensiveness, compared to LCC HVDC. Recently, the new technologies and the demand for renewable energy interconnection are leading a large growth in VSC HVDC market. In this paper, we will introduce the technical and market trends of VSC HVDC and power system stability analysis results for Jeju power system having LCC and VSC HVDCs.

Hardware-in-the-Loop Simulation을 이용한 3-레벨 NPC 전압형 HVDC 시스템 구현 및 테스트 (Implementation and Test of 3-level NPC VSC-HVDC System using Hardware-in-the-Loop Simulation)

  • 유형준;김남대;김학만
    • 전기학회논문지
    • /
    • 제63권3호
    • /
    • pp.343-348
    • /
    • 2014
  • Recently, applications of VSC-HVDC systems to power systems are growing because of their control ability of reactive power. Meanwhile, the hardware-in-the-loop simulation (HILS) based on the real-time digital simulator has been applying to develop and test imbedded controllers and systems in the power industry to decrease costs and to save time. In this paper, a 3-level neutral point clamped (NPC) VSC-HVDC system is modeled and the embedded controllers of the NPC VSC-HVDC system are designed. The designed controllers are implemented by TMS320F28335. The TMS320F28335-based controllers of the NPC VSC-HVDC system are tested using the HILS.