• Title/Summary/Keyword: VP8

Search Result 272, Processing Time 0.032 seconds

A Study on the Fabrication of CsI(T1) Radiation Sensor and its Spectroscopic Characteristics (CsI(T1) 방사선센서의 제작 및 분광특성 연구)

  • 권수일;신동호
    • Progress in Medical Physics
    • /
    • v.13 no.1
    • /
    • pp.44-50
    • /
    • 2002
  • CsI(T1) single crystal was grown in a Bridgman growing apparatus, which has the diameter of 11 mm and the mole ratio of 0.001 mol%. Radiation sensors were made with CsITl)crystal and two photodiodes, and measured spectroscopic characteristics and linearity for gamma-ray and X-ray. The energy resolution of CsI(T1) radiation sensor has been measured with $^{22}$ Na, $^{137}$ Cs and $^{60}$ Co gamma standard sources. Also output linearity of CsITl) sensor was measured for diagnostic radiation region. The energy resolutions of CsI(T1) radiation sensor for 0.511MeV gamma-ray from Na-22 source, 0.662MeV from Cs-137 source, and 1.17MeV and 1.332MeV from Co-60 source were 13.2%, 8.3%, 6.7%, and 5.1% respectively. Also the output linearity up to 80mAs current for 60kVp, 80kvp, 100kVp, 120kVp tube voltages has been studied.

  • PDF

Doses of Coronary Study in 64 Channel Multi-Detector Computed Tomography : Reduced Radiation Dose According to Varity of Examnination Protocols (64 채널 Multi-Detector Computed Tomography를 이용한 관상동맥검사의 선량 : 검사 프로토콜 다변화에 따른 환자선량 감소)

  • Kim, Moon-Chan
    • Journal of radiological science and technology
    • /
    • v.32 no.3
    • /
    • pp.299-306
    • /
    • 2009
  • Purpose : To compare radiation dose for coronary CT angiography (CTA) obtained with 6 examination protocols such as a retrospectively ECG gated helical scan, a prospectively ECG gated sequential scan, low kVp technique, and cardiac dose modulation technique. Materials and Methods : Coronary CTA was performed by using 6 current clinical protocols to evaluate effective dose and organ dose in primary beam area with anthropomorphic female phantom and glass dosimetric system in 64 channel multi-detector CT. After acquiring topograms of frontal and lateral projection with 80 kVp and 10 mA, main coronary scan was done with 0.35 sec tube rotation time, 40 mm collimation ($0.625\;mm{\times}64\;ea$), small scan field of view (32 cm diameter), 105 mm scan length. Heart beat rate of phantom was maintained 60 bpm in ECG gating. In constant mAs technique 120 kVp, 600 mA was used, and 100 kVp for low kVp technique. In a retrospectively ECG gated helical CT technique 0.22 pitch was used, peak mA (600 mA) was adopted in range of $40{\sim}80%$ of R-R interval and 120mA(80% reduction) in others with cardiac dose modulation. And 210 mAs was used without cardiac dose modulation. In a prospectively ECG gated sequential CT technique data were acquired at 75% R-R interval (middle diastolic phase in cardiac cycle), and 120 msec additional padding of the tube-on time was used. For effective dose calculation region specific conversion factor of dose length product in thorax was used, which was recommended by EUR 16262. Results : The mean effective dose for conventional coronary CTA without cardiac dose modulation in a retrospectively ECG gated helical scan was 17.8 mSv, and mean organ dose of heart was 103.8 mGy. With low kVp and cardiac dose modulation the mean effective dose showed 54.5% reduction, and heart dose showed 52.3% reduction, compared with that of conventional coronary CTA. And at the sequential scan(SnapShot pulse mode) under prospective ECG gating the mean effective dose was 4.9 mSv, this represents an 72.5% reduction compared with that of conventional coronary CTA. And heart dose was 33.8 mGy, this represents 67.4% reduction. In the sequential scan technique under prospective ECG gating with low kVp the mean effective dose was 3.0 mSv, this represents an 83.2% reduction compared with that of conventional coronary CTA. And heart dose was 17.7 mGy, this represents an 82.9% reduction. Conclusion : In coronary CTA at retrospectively ECG gated helical scan, cardiac dose modulation technique using low kVp reduced dose to 50% above compared with the conventional helical scan. And the prospectively ECG gated sequential scan offers substantially reduced dose compared with the traditional retrospectively ECG gated helical scan.

  • PDF

Performance Analysis of Open Web Video Codec VP8

  • Park, Younghyeon;Lee, Hoyoung;Jeon, Byeungwoo
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.2 no.2
    • /
    • pp.86-96
    • /
    • 2013
  • VP8, an open web media video format, has recently attractedmuch attention, particularly from major web browser companies, as a video codec for HTML5 on internet due to its good coding efficiency and royalty-free policy. Compared to other video compression schemes such as H.264/AVC, it has several distinctive coding tools that help to ensure good coding efficiency and low decoding complexity. In this paper, we investigate its coding techniques and analyze its rate-distortion (R-D) coding performance as compared to that of H.264/AVC.

  • PDF

Selective Chemical Wet Etching of Si0.8Ge0.2/Si Multilayer

  • Kil, Yeon-Ho;Yang, Jong-Han;Kang, Sukil;Jeong, Tae Soo;Kim, Taek Sung;Shim, Kyu-Hwan
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.13 no.6
    • /
    • pp.668-675
    • /
    • 2013
  • We investigate the effect of the ageing time and etching time on the etching rate of SiGe mixed etching solution, namely 1 vp HF (6%), 2 vp $H_2O_2$ (30%) and 3 vp $CH_3COOH$ (99.8%). For this etching solution, we found that the etch rate of SiGe layer is saturated after the ageing time of 72 hours, and the selectivity of $Si_{0.8}Ge_{0.2}$ layer and Si layer is 20:1 at ageing time of 72 hours. The collapse was appeared at the etching time of 9min with etching solution of after saturation ageing time.

Typing and Sequence Analysis of the VP7 Gene of Rotavirus Isolated from Infants in Korea (한국영아에서 분리된 로타바이러스의 VP7 유전자형 및 염기서열 분석)

  • Song, Mi-Ok;Yun, Karyn;Chung, Sang-In;Choi, Chul-Soon;Lim, In-Seok;Kang, Shien-Young;An, Chang-Nam;Kim, Won-Yong
    • The Journal of Korean Society of Virology
    • /
    • v.30 no.2
    • /
    • pp.101-112
    • /
    • 2000
  • Rotaviruses are the most common cause of severe vomiting and diarrhea in children worldwide and classified as a genus in the family Reoviridae. Rotavirus has eleven segmented dsRNAs and the virion consists of three shells. Outer capsid VP7 and VP4 induce neutralizing antibodies and are classified into G types (glycoprotein VP7) and P types (protease-sensitive VP4). Characterization of VP7 gene of Korean isolates of human rotavirus was performed using multiplex PCR and nucleotide sequence analysis. After RT-PCR amplification of full length (1,062 bp) of VP7 genes, the amplified PCR products were G typed by multiplex PCR and the nucleotide sequences were compared with those of reference rotavirus from GenBank. The G type analysis revealed that 25% (2/8) belong to G1, whereas 37.5% (3/8) benong to G2 and G4, respectively. The Korean isolates within the same serotypes showed high homology of nucleotide sequences and could be discriminated from foreign isolates exception with two strains (CAU009 and CAU022). But Korean isolates CAU009 and CAU022 were close related into japanease isolates 417 (99.2%) and indian isolates (97.6%) than Korean isolatese. Our results showed that these two strains were supposed to be originated from abroad. As a results, The G typing and nucleotide sequence analysis of VP7 gene of rotavirus isolated from infants in Korea could be used for identification, serotying and determination of novel or unusual strains of rotaviruses.

  • PDF

Selective Permeate Transport Characteristics of Iodine ion at Cell Membrane Model of Thyroid which Irradiated by High Energy X-Ray (고에너지 엑스선을 조사한 갑상선의 세포막모델에서 요오드이온의 선택적 투과성 전달 특성)

  • Ko, In-Ho;Yeo, Jin-Dong
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.2
    • /
    • pp.229-238
    • /
    • 2021
  • The selective permeate transport characteristics of iodine ion at follicle cell membrane model in thyroid which irradiated by high energy x-ray(linac 6 MV) was investigated. The follicle cell membrane model used in this experiment was a polysulfonated copolymerized membrane of poly(4-vinylpyridine-co-acrylonitrile:VP-AN). The difference of membrane thickness [2 mole AN%(w/w)], fixed carrier concentration[VP-AN%(w/w)], OH- concentration were occurred at difference of I- concentration and quantity of thyroid hormone, respectively. The tensile strength in fixed carrier concentration[VP-AN% (w/w): 0-62 %] of irradiated membrane was found to be decreased about 1.2-1.8 times than non-irradiated membrane. The I- selective permeate initial flux with increase of membrane thickness [2mole AN%(w/w)], fixed carrier concentration[VP-AN%(w/ w)], OH- concentration in irradiated membrane were found to be decreased about 2.1-4.5 times, about 2.2-2.5 times, about 2.1-2.67 times than non-irradiated membrane, respectively. As a result, the quantity of thyroid hormone was decreased at irradiated membrane than non-irradiated membrane. The decrease of thyroid hormone was occurred at hypothyroidism and hyperthyroidism, thyroid cancer, and so on. As the thyroid hormone in cell membrane model were abnormal, cell damages were appeared at cell.

Tumorigenesis of Transgenic Mice Induced by Mouse Vasopressin-SV40 T Hybrid Oncogene

  • Lee, Eun-Ju;Kim, Myoung-Ok;Kim, Sung-Hyun;Park, Jun-Hong;Park, Jung-Ok;Cho, Kyong-In;Park, Hum-Dai;Ryoo, Zae-Young
    • Proceedings of the KSAR Conference
    • /
    • 2002.06a
    • /
    • pp.92-92
    • /
    • 2002
  • The neuropeptide vasopressin (VP) is a nine- amino acid hormone synthesized as preprohormone in the cell bodies of hypothalamic magnocellular neurons. The tumor in magnocellular neurons of the hypothalamus is associated with disfunctions of the cell bodies, leading to the diabetes insipidus. In order to produce the disease models with a defect in VP synthesis and its secretion, we have produced the transgenic mice regulated by VP constructs containing 3.8 kbp of the 5'flanking region and all the exons and introns in the mouse VP gene, which was fused at the end of exon 3 to a SV40 Tag. The two VP-transgene constructs differed by the lengths of their VP gene 3' flanking regions (2.1 versus 3.6 kbp). (omitted)

  • PDF

cDNA Cloning and Nucleotide Sequence Determination for VP7 Coding RNA Segment of Human Rotavirus Isolated in Korea (한국에서 분리된 사람 로타바이러스의 VP7 코딩 RNA 분절의 cDNA 합성과 염기서열 결정)

  • Kim, Young Bong;Kim, Kyung Hee;Yang Jai Myung
    • Korean Journal of Microbiology
    • /
    • v.30 no.5
    • /
    • pp.397-402
    • /
    • 1992
  • The cDNA of RNA segment coding for VP7 of human rotavirus isolated from patient's stool at Seoul area was synthesized, amplified by polymerase chain reaction, field in with Klenow fragment of DNA polymerase I and cloned into pUC19. The cDNA sequence was determined and compared with that of VP7 coding RNA segments of group A rotaviruses isolates in foreign country. Over 90% sequence homology was found with serotyppe I sepcific WA1 and RE9 strains. Comparative analysis of the deduced amino acid sequences within the two variable regions (amino acid residue 87 through 101 and 208 through 221) with WA1 and RE9 strains also showed high degree of sequence similarity with each other.

  • PDF

Production of monoclonal antibodies against VP28 of white spot syndrome virus (WSSV) (White spot syndrome virus (WSSV)의 VP28에 대한 단클론 항체 생산)

  • Bang, Ji-hyeong;Kim, Wi-Sik;Kim, Choon-sup;Kim, Jong-Oh;Oh, Myung-Joo
    • Journal of fish pathology
    • /
    • v.32 no.1
    • /
    • pp.45-48
    • /
    • 2019
  • We developed and subsequently characterized mouse monoclonal antibodies (MAbs) against recombinant VP28 structural protein (rVP28) of white spot syndrome virus (WSSV). We established six hybridoma clones secreting MAbs against rVP28: 15A11, 20G6, 31H2, 34H6, 38D1 and 43A1. All six MAbs recognized the 25 kDa of protein in gill homogenates of WSSV-infected shrimp by western blot analysis, while no reactivity was observed in gill homogenates of normal shrimp. Moreover, high enzyme-linked immunosorbent assay (ELISA) optical density (OD) values (0.8-2.68) were observed in the hemolymphs from WSSV-infected shrimp, while low OD values (less than 0.24) were recorded in the hemolymphs from normal shrimp, by using these six MAbs produced in this study. These results suggest that these six MAbs are useful for the detection of WSSV.

A Study of the Bone Marrow Dose in Chest and Abdomen Radiography (흉부(胸部) 및 복부(腹部)X선촬영시(線撮影時) 환자(患者)의 골수선량(骨髓線量)에 대한 연구(硏究))

  • Choi, Jong-Hak;Huh, Joon
    • Journal of radiological science and technology
    • /
    • v.13 no.2
    • /
    • pp.31-36
    • /
    • 1990
  • We got the following results from the experiment and examination in order to measure the bone-marrow dose of the patients when we did chest or abdomen radiography in the hospitals located in Seoul City from Jan. 1989 until Feb. 1990. 1. In the exposure factors for chest radiography, tube voltage $60{\sim}69\;kVp$ took 48.3%, $80{\sim}89\;or\;90{\sim}99\;kVp$ took 13.8% respectively, $70{\sim}79\;kVp$ 10.3% and $100{\sim}129\;kVp$ 10.3%. In tube current and exposure times, $6{\sim}10\;mAs$ took 41.4%, $16{\sim}20\;mAs$ took 20.7% and $11{\sim}15\;mAs$ 13.8%, measure under 5mAs 10.4% orderly. 2. In chest radiography, the bone-marrow dose came to the minimum 3.48 mrad, to the maximum 35.67 mrad, to the mean 14.46 mrad, to the standard deviation 8.89 mrad. 3. Comparing bone-marrow doses of the patients when we used Bucky technique and non-Bucky technique, that of Bucky technique was very higher than that of non-Bucky technique. Because the result was that Bucky technique had the span of $6.09{\sim}35.67$ mrad, while non-Bucky technique had the span of $3.48{\sim}17.40$ mrad. 4. In the exposure factors for abdomen radiography, tube voltage of $70{\sim}79\;kVp$ was 63.0%, that of $80{\sim}89\;kVp$ was 22.2%, that of $60{\sim}69\;kVp$ was 11.1 %. Tube current and exposure times of $31{\sim}40\;kVp$ was 33.4%, that of $51{\sim}60\;mAs$ was 29.6% and that of $41{\sim}50\;mAs$ was 22.2%. 5. In abdomen radiography, the bone-marrow dose of the patients came to the minimum of 6.96 mrad, to the maximum of 60.90 mrad, to the mean of 35.73mrad, to the standard deviation of 12.65 mrad.

  • PDF