• Title/Summary/Keyword: VP7

Search Result 275, Processing Time 0.023 seconds

Expression of the VP2 protein of feline panleukopenia virus in insect cells and use thereof in a hemagglutination inhibition assay

  • Yang, Dong-Kun;Park, Yeseul;Park, Yu-Ri;Yoo, Jae Young;An, Sungjun;Park, Jungwon;Hyun, Bang-Hun
    • Korean Journal of Veterinary Research
    • /
    • v.61 no.2
    • /
    • pp.19.1-19.7
    • /
    • 2021
  • Feline panleukopenia virus (FPV) causes leukopenia and severe hemorrhagic diarrhea, killing 50% of naturally infected cats. Although intact FPV can serve as an antigen in the hemagglutination inhibition (HI) test, an accidental laboratory-mediated infection is concern. A non-infectious diagnostic reagent is required for the HI test. Here, we expressed the viral protein 2 (VP2) gene of the FPV strain currently prevalent in South Korea in a baculovirus expression system; VP2 protein was identified by an indirect immunofluorescence assay, electron microscopy (EM), Western blotting (WB), and a hemagglutination assay (HA). EM showed that the recombinant VP2 protein self-assembled to form virus-like particles. WB revealed that the recombinant VP2 was 65 kDa in size. The HA activity of the recombinant VP2 protein was very high at 1:215. A total of 143 cat serum samples were tested using FPV (HI-FPV test) and the recombinant VP2 protein (HI-VP2 test) as HI antigens. The sensitivity, specificity, and accuracy of the HI-VP2 test were 99.3%, 88.9%, and 99.3%, respectively, compared to the HI-FPV test. The HI-VP2 and HI-FPV results correlated significantly (r = 0.978). Thus, recombinant VP2 can substitute for intact FPV as the serological diagnostic reagent of the HI test for FPV.

PSNR Correlation between CR and DR according to Changed KvP (CR과 DR의 kVp 변화에 따른 PSNR 상관관계)

  • Kim, Jisun;Ahn, Byungju
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.7
    • /
    • pp.417-422
    • /
    • 2014
  • In this study, the influence degree of the scattering of the line depending on the incident energy of the radiation objective was to evaluate a new method of quantitative methods of PSNR is provided.Value of MSE and PSNR of the DR and the Target is placed at the left when there was no change in CR Target, the change appeared to ttaran MSE and PSNR value in tube voltage. Both CR and DR seen that there is a variation of the MSE and PSNR depending on the tube voltage change Computon showed that the scattered radiation effects. If the CR and DR 80 The changes in the MSE and PSNR experience the symptoms suddenly occur in areas kVp was found to affect the optoelectronic Computon E, and at the same time, the scattered radiation detector Computon Computon by scattering due to the photoelectric effect. CR and DR of the imaging device in the future on the basis of the energy bands of the photoelectric effect of 60 kVp 70 kVp, 80 kVp, 90 kVp, compares the value of the PSNR and MSE 100 kVp in accordance with the change of the tube voltage of the CR and device DR proposes jigil scattering study of the degradation of the line quality is achieved.

Dose and Image Evaluation according to Changes in Tube Voltage during Chest X-ray Examination according to Automatic Exposure Control (자동노출제어장치 유·무에 따른 흉부 후·전방향 검사 시 관전압 변화에 따른 선량 및 영상평가)

  • Young-Cheol, Joo;Dong-Hee, Hong
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.7
    • /
    • pp.871-877
    • /
    • 2022
  • This study was conducted to improve the problems of exposure dose and image reading applied to patients due to the incorrect use of AEC during chest radiography. Images were acquired by dividing the case where AEC was used as the test condition and the case where AEC was not used. As a result of the study, the dose was reduced by 1.17% in 110 kVp without AEC than with AEC, 17.2% decrease at 100 kVp, 30.19% decrease at 90 kVp, and 46.45% decrease at 80 kVp. There was a significant difference in the statistical values according to the tube voltage change in the lung, trachea, and heart SNR average values with AEC and without AEC 110 kVp, but the difference in image quality was insignificant in actual images. When AEC was not applied at the same tube voltage, the dose could be reduced by 17.2% while maintaining the image quality similar to that of with AEC at 100 kVp without AEC. Therefore, rather than relying on AE conditions during chest radiographic examination, it is considered that the conditions should be considered for the examination while lowering the dose by selecting an appropriate tube voltage.

Evaluation of Image Quality in Low Tube-Voltage Chest CT Scan (흉부 CT 검사 시 저 관전압 영상의 화질평가에 관한 연구)

  • Kim, Hyun-Ju;Cho, Jae-Hwan;Park, Cheol-Soo
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.4
    • /
    • pp.135-141
    • /
    • 2010
  • Purpose : The patients who visited this department for pulmonary disease and need CT scans for Follow-up to observe change of CT value, evaluation of image quality and decrease of radiation dose as change of kVp. Subjects and Methods : Subjects were the patients of 20 persons visited this department for pulmonary disease and Somatom Sensation 16(Semens, Enlarge, Germany) was used. Measurement of CT value as change of kVp was done by setting up ROI diameter of 1cm at the height of thyroid, aortic arch, right pulmonary artery in arterial phase image using 100 kVp, measuring 3 times, and recorded the average. CT value of phantom was measured by scanning phantoms which means contrast media diluted by normal saline by various ratio with tube voltage of 80 kVp, 100 kVp, 120 kVp, 140 kVp and recorded the average of 3 CT values of center of phantom image. In analysing radiation dose, CTDIVOL values of the latest arterial phase image of 120 kVp and as this research set that of 100 kVp were analyzed comparatively. 2 observers graded quality of chest images by 5 degrees (Unacceptable, Suboptimal, Adequate, Good, Excellent). Results : CT value of chest image increased at 100 kVp by 14.06%~27.26% in each ROI than 120 kVp. CT value of phantom increased as tube voltage lowered at various concentration of contrast media. CTDIVOL decreased at 100 kVp(5.00 mGy) by 36% than 120 kVp(7.80 mGy) in radiation dose analysis. here were 0 Unacceptable, 1 Suboptimal, 3 Adequate, 10 Good, 6 Excellent in totally 20 persons. Conclusion : Chest CT scanning with low kilo-voltage for patients who need CT scan repeatedly can bring images valuable for diagnose, and decrease radiation dose against patients.

Accurate Measurement of Agatston Score Using kVp-Independent Reconstruction Algorithm for Ultra-High-Pitch Sn150 kVp CT

  • Xi Hu;Xinwei Tao;Yueqiao Zhang;Zhongfeng Niu;Yong Zhang;Thomas Allmendinger;Yu Kuang;Bin Chen
    • Korean Journal of Radiology
    • /
    • v.22 no.11
    • /
    • pp.1777-1785
    • /
    • 2021
  • Objective: To investigate the accuracy of the Agatston score obtained with the ultra-high-pitch (UHP) acquisition mode using tin-filter spectral shaping (Sn150 kVp) and a kVp-independent reconstruction algorithm to reduce the radiation dose. Materials and Methods: This prospective study included 114 patients (mean ± standard deviation, 60.3 ± 9.8 years; 74 male) who underwent a standard 120 kVp scan and an additional UHP Sn150 kVp scan for coronary artery calcification scoring (CACS). These two datasets were reconstructed using a standard reconstruction algorithm (120 kVp + Qr36d, protocol A; Sn150 kVp + Qr36d, protocol B). In addition, the Sn150 kVp dataset was reconstructed using a kVp-independent reconstruction algorithm (Sn150 kVp + Sa36d, protocol C). The Agatston scores for protocols A and B, as well as protocols A and C, were compared. The agreement between the scores was assessed using the intraclass correlation coefficient (ICC) and the Bland-Altman plot. The radiation doses for the 120 kVp and UHP Sn150 kVp acquisition modes were also compared. Results: No significant difference was observed in the Agatston score for protocols A (median, 63.05; interquartile range [IQR], 0-232.28) and C (median, 60.25; IQR, 0-195.20) (p = 0.060). The mean difference in the Agatston score for protocols A and C was relatively small (-7.82) and with the limits of agreement from -65.20 to 49.56 (ICC = 0.997). The Agatston score for protocol B (median, 34.85; IQR, 0-120.73) was significantly underestimated compared with that for protocol A (p < 0.001). The UHP Sn150 kVp mode facilitated an effective radiation dose reduction by approximately 30% (0.58 vs. 0.82 mSv, p < 0.001) from that associated with the standard 120 kVp mode. Conclusion: The Agatston scores for CACS with the UHP Sn150 kVp mode with a kVp-independent reconstruction algorithm and the standard 120 kVp demonstrated excellent agreement with a small mean difference and narrow agreement limits. The UHP Sn150 kVp mode allowed a significant reduction in the radiation dose.

Evaluation of Image Quality and dose with the Change of kVp and BMI in the Liver CT (CT 검사 시 관전압과 BMI 변화에 따른 화질 및 피폭평가)

  • Kim, Dong-Hyun;Ko, Sung-Jin;Kang, Se-Sik;Kim, Jung-Hoon;Choi, Seok-Yoon;Kim, Changsoo
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.6
    • /
    • pp.331-338
    • /
    • 2013
  • CT for follow-up visits because of liver disease, body mass index (BMI) and kVp according to the change of the image quality and radiation dose to evaluate for changes. March 2010 to June 2011 at Pusan P University Hospital, abdominal CT scans a patient BMI (Body Mass Index. Less BMI) index was less than 25 in the treatment of subjects had a 48-person Noise and SNR at 100kVp abdominal image is lager than the 120kVp image. CTDI volume value at by the analysis of the radiation dose is 4.47mGy(100kVp) and 9.01mGy(120kVp). So CTDIvol in 100kVp is smaller than CTDIvol in 120kVp(decrease by 44.1%). And, effective dose is 7.1mSv(100kVp) and 12.51mSv(120kVp). So effective dose in 100kVp is smaller than effective dose in 120kVp(decrease by 43%). Evaluation of image quality is that Unacceptable 0 person, Suboptimal 0 person, Adequate 0 person, Good 1 person, Excellent 47 person. In case of repeatly patient, we examinate abdomianl CT scan by using low kVp and body mass index less than 25. We can has good quality image and benefit of low radiation dose.

Dose and Image Assessment according to Radiologic Factors Variation at Digital Humerus X-ray Examination (디지털 환경에서 Humerus 검사 시 촬영인자 변화에 따른 선량 및 화질 평가)

  • Kim, Seong Min;Hong, Seon Sook;Lee, Kwan Sup;Ha, Dong Yun
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.2
    • /
    • pp.1-8
    • /
    • 2012
  • Purpose : We aim at presenting the optimum radiologic factor through the evaluation of dose variation and of image quality through the use of a grid in Humerus examination and the change of dose because of the change of radiologic factor. Materials and Methods : We divided it in 3 cases: when using a grid or not and when using IP(Image Plate) in a digital system. Also, as fixing kVp to 70kVp it changed mAs, and fixing mAs to 10 it changed kVp, we put up resolution chart and Burger rose phantom on the acrylic phantom of 7cm (the same level of Humerus) to evaluate the dose and image. We used Image J program to evaluate the quantitative resolution of the obtained image, and made the qualitative evaluation and statistical analysis of the image saved in PACS for 20 radiologic technologist with more than 10 years of experience in order of evaluate its contrast. We used SPSS10(SPSS Inc. Chicago, Illinois) for statistical analysis. Results : We observed the analytic result of resolution by the change of kVp that it was $4.539dGycm^2$ in 60kVp and $757.472dGycm^2$ in 75kVp, which increased about 64.6% of dose, while for the resolution it had the pixel value 30.7% better with 851 in 60kVp than 651 in 75kVp. Also, we analyzed the result of resolution by the change of mAs that it was $3.106dGycm^2$ in 5mAs, and $12.470dGycm^2$ in 20mAs, which increased about 400% of dose, while for the resolution DR had 678 in 5mAs, and 724 in 20mAs that increased about 6.8% of resolution. We made the qualitative evaluation of contrast by the change of kVp that DR showed the higher quality than CR, but the contrast by the change of kVp had no special different at the moment of visual evaluation, nor statistically significant difference(P>0.05). We observed the qualitative evaluation of contraste by the change of mAs that the contrast increased as DR increased mAs, and had statistically significant difference(P<0.05). On the other hand, CR had no significant difference for more than 10mAs nor statistically significant difference(P>0.05). Conclusion : In case of some patients with radiographic exposure by the repeated examination such as emergent patient or Follow up patient, they are considered to try to limit the use of a grid, to set kVp under 65kVp in fixed mode, to select less than 10mAs and to reduce the possibility of patient being bombed.

  • PDF

Construction of FMDV VP1 Gene Using Artificial DNA Synthesis and Transformation of Nicotiana tabacum Using Agrobacterium Vector System (유전자 인공합성을 이용한 구제역 유전자 VP1의 제작과 Agrobacterium Vector System을 이용한 담배 형질전환)

  • Lee, Eun-Jung;Lim, Hee-Young;Kim, Sung-Hoon;Kang, Kyung-Sun;Park, Young-Doo;Yun, Choong-Hyo;Yoon, Byoung-Su
    • Journal of Plant Biotechnology
    • /
    • v.31 no.4
    • /
    • pp.285-293
    • /
    • 2004
  • FMDV is a viral pathogen that caused foot-and-mouth disease in animals. VP1 is a major capsid protein of FMDV. It is known as one of best materials for the FMDV diagnosis and for the development of protein vaccine. In this study, 633 bp of VP1 gene was modified for the expression of VP1 in plant, based on the VP1 DNA sequence from FMDV taiwan O type and from FMDV isolated vietnam. The. deduced DNA fragment was artificially synthesized using the multiple fragment extension with long-nucleotides. A new plant transgenic vector system, pCAMBIA139011 was constructed on the basis of pBI12l and pCAMBIA1390. Using this vector system and GFP gene or modified VP1 gene, each target gene was introduced into Nicotiana tabacum. The insertion of whole target gene was successfully confirmed in each transgenic plant named GFP-A7 and VP1-4, respectively. The expression level of each gene was estimated by RT-PCR and Real-Time PCR using VP1, GFP specific primers.

The Ordered Structures of Poly(styrene-b-4vinylpridine)s

  • Pak, Soo-Young;Sul, Woo-Hwan;Chang, Yun-Jeong
    • Proceedings of the Polymer Society of Korea Conference
    • /
    • 2006.10a
    • /
    • pp.191-191
    • /
    • 2006
  • The structures of the mesophases and their subunits of PS-b-P4VP in a toluene solution were studied by using SAXS, TEM and GIFT methods. The hierarchical structures of PS-b-P4VP, such as the individual micelle, the face-centered cubic (fcc) and body-centered cubic (bcc) structures and the lamellar structure, were identified for the first time. The diameter of the micelle core was ${\sim}80\;%$ of the most extended chain length of the core chain, suggesting that the core chains were quite stretched. The stretched chain in the core caused the core of the micelle to be not homogenous with a higher density at the center than at the outer part. As the concentration level increases, the fcc and both fcc and bcc appear for the packing of the micelles of PS(3.3k)-b-P4VP(4.7K) and PS(12K)-b-P4VP(11.8K), respectively. The lamellar structure was also identified, with a further increase in the concentration for PS(3.3k)-b-P4VP(4.7K). These hierarchical structures were also identified via TEM images.

  • PDF

A Study on the Preparation of Carboxylated Polysulfone/MeVpI-DVB Membranes and Its Characteristics (Carboxylated Polysulfon/MeVpl-DVB 막의 제조와 특성에 관한 연구)

  • 김관식;전경용;조영일
    • Membrane Journal
    • /
    • v.5 no.1
    • /
    • pp.26-34
    • /
    • 1995
  • In this study, polysulfone was carboxylated(CPSf), as a method of introducing carboxyl group to polymer main chain using direct lithiation reaction. Then, poly(1-alkyl-4-vinylpyridinium iodide-co-divinylbenzene) (MeVpI-DVB) containing pyridinium cation which has an anion selectivity as a fixed carrier was synthesized. And polymer membranes were prepared by mixing CPSf and MeVpI-DVB. Characteristics and permeation of membranes were investigated. As a result of synthesizing CPSf/MeVpI-DVB, blend was formed, not new copolymer. As the content of CPSf amount increasing, thermal stability of membranes was increasing. Ion exchange capacity was 1.0~1.8(meq/g dry mem.) and water content was 0.16~0.26(g $H_2{O}$)/g dry mem.) and fixed ion concentration was 6.4~7.3(meq/g $H_2{O}$) in synthetic membranes. The $Cl^-$ flux showed an increase due to the increase of CPSf content.

  • PDF