• Title/Summary/Keyword: V/f control

Search Result 397, Processing Time 0.025 seconds

High Speed Non-Inverting SOI Buffer Circuit by Adopting Dynamic Threshold Control (동적 문턱전압 제어 기법을 이용한 고속 비반전 SOI 버퍼 회로)

  • 이종호;박영준
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.35D no.6
    • /
    • pp.28-36
    • /
    • 1998
  • We have proposed a new non-inverting SOI buffer circuit for the high speed operation at low supply voltage. The body biases of main MOS devices in the proposed circuit are controlled dynamically via subsidiary MOS device connected efficiently to the body terminal. We showed current derivability of the body controlled devices obtained by device simulation and compared with that of conventional SOI devices. Delay time characteristics of the buffer circuit were analyzed by SPICE simulation and compared with those of conventional SOI CMOS buffer circuits. Delay time reduction of the SOI buffer over conventional SOI CMOS buffer with same area is about 36 % at $V_{S}$=1.2 V and $C_{L}$=2 pF. pF.

  • PDF

A design of discrete time nonlinear control system with disturbances using model following method

  • Zhang, Yuan-Sheng;Okubo, Shigenori
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10a
    • /
    • pp.239-242
    • /
    • 1996
  • A model following control system(MFCS) can give general output signals following desired ones. In previous studies, a method of nonlinear MFCS was proposed by S.Okubo[1]. In this paper, the method of nonlinear MFCS will be extended to discrete time nonlinear systems. It is easy to extend the method to discrete time systems. But in the case .gamma.=1 discrete time systems, the proof becomes difficult, because the transfer function from f(v(k)) to v(k) can't be a positive real function. In this case, to ensure that internal states are stable, a new criterion is proposed.

  • PDF

Development of the Inverter System with UPS Function for the Air-Conditioning Blower (UPS 기능을 갖는 A/C Blower용 인버터 시스템 개발)

  • Lim, Seung-Beom;Lee, Yun-Ha;Mok, Hyung-Soo;Ji, Jun-Keun
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.3
    • /
    • pp.302-308
    • /
    • 2011
  • The HVAC(Heating Ventilation and Air Conditioning) system is only controlled by turn on/turn off operations with AC 380V input. Therefore, the efficiency of the system is reduced and accoustic noise problem occurs. Also, the blower is shut down at the AC power failure. In this paper, the inverter system with UPS function for the A/C(Air Conditioning) blower is proposed. Proposed inverter system which is powered from the AC and DC voltage can control speed, operation mode, and soft-start time using CAN communication. In case of the CAN communication failure, RS-232 communication could be used to control the hardware directly by the engineer that can solve existing problems. To verify the validity of proposed inverter system, simulations and experiments are carried out.

Low-Cost Single-Phase to Three-Phase AC/DC/AC PWM Converters for Induction Motor Drives (유도전동기 구동을 위한 저가형 단상-3상 AC/DC/AC PWM 컨버터)

  • 김태윤;이지명;석줄기;이동춘
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.7 no.4
    • /
    • pp.322-331
    • /
    • 2002
  • In this paper, a single-phase to three-phase PWM converter topology using a single-phase half-bridge PWM rectifier and a 2-leg inverter for low cost three-phase induction motor drives is proposed. In addition, the source voltage sensor is eliminated with a state observer which controls the deviation between the model current and the system current to be zero. The converter topology is of lower cost than the conventional one, which gives sinusoidal input current, unity power factor, dc output voltage control, bidirectional power flow and VVVF output voltage. The experimental results for V/F control of 3Hp induction motor drives have been shown.

The Control of load Commutated Current Source Inverter for Induction Motor Drive (유도전동기(誘導電動機) 구동(驅動)을 위한 부하전류식(負荷轉流式) 전류형(電流型) 인버터의 제어(制御))

  • Chung, Y.T.;Sim, J.M.;Lee, S.Y.;Soh, Y.C.;Lee, J.W.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.255-257
    • /
    • 1994
  • The V/F slip frequency constant control methods are used for driving induction motor with load commutated current source inverter, that is. constant V/F and slip frequency driving is used to load commutate the inverter below the critical frequency, while constant voltage and variable frequency and slip frequency driving are used in above the critical region. In order to applicate the load commutated current source inverter to the general use, speed control range of induction noter is selected to two times at rated frequency. Therefore, economical application is possible because of the maximum reduction of the condenser of the inverter output port. The use of the proposed force commutated circuit improves the false operation of force commutated circuit and inverter commutation failure which are produced by the influence of the lower-order harmonics of the conventional load commutated current source inverter at starting.

  • PDF

FCXO ; A Fuzzy Compensated Crystal Oscillator

  • de los Mozos, Mario Reyesr;Valderrama, Elena;Arguelles, Javier
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 1993.06a
    • /
    • pp.842-844
    • /
    • 1993
  • We present a F.L.C. (Fuzzy Logic Controller) to control of the oscillation frequency of a V.C.X.O. (Voltage Controled Crystal Oscillator). This F.C.X.O. maintains stable its oscillation frequency inside a range of 1 ppm (one part per millon), with temperature between -55$^{\circ}C$ to+75$^{\circ}C$.

  • PDF

Effects of Vth adjustment ion implantation on Switching Characteristics of MCT(MOS Controlled Thyristor) (문턱전압 조절 이온주입에 따른 MCT (MOS Controlled Thyristor)의 스위칭 특성 연구)

  • Park, Kun-Sik;Cho, Doohyung;Won, Jong-Il;Kwak, Changsub
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.5
    • /
    • pp.69-76
    • /
    • 2016
  • Current driving capability of MCT (MOS Controlled Thyristor) is determined by turn-off capability of conducting current, that is off-FET performance of MCT. On the other hand, having a good turn-on characteristics, including high peak anode current ($I_{peak}$) and rate of change of current (di/dt), is essential for pulsed power system which is one of major application field of MCTs. To satisfy above two requirements, careful control of on/off-FET performance is required. However, triple diffusion and several oxidation processes change surface doping profile and make it hard to control threshold voltage ($V_{th}$) of on/off-FET. In this paper, we have demonstrated the effect of $V_{th}$ adjustment ion implantation on the performance of MCT. The fabricated MCTs (active area = $0.465mm^2$) show forward voltage drop ($V_F$) of 1.25 V at $100A/cm^2$ and Ipeak of 290 A and di/dt of $5.8kA/{\mu}s$ at $V_A=800V$. While these characteristics are unaltered by $V_{th}$ adjustment ion implantation, the turn-off gate voltage is reduced from -3.5 V to -1.6 V for conducting current of $100A/cm^2$ when the $V_{th}$ adjustment ion implantation is carried out. This demonstrates that the current driving capability is enhanced without degradation of forward conduction and turn-on switching characteristics.

Analysis on Driving Performance of Linear Induction Motor for Maglev System by Finite Element Method (유한요소법을 이용한 자기부상용 선형유도기의 운전 특성 분석법)

  • Kim, Ki-Chan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.7
    • /
    • pp.4469-4474
    • /
    • 2014
  • This paper proposes a novel analysis method on the driving performance of LIM (linear induction motor) by FEM (finite element method). First, a linear model was converted with a rotation model to perform the dynamic analysis for a long time. Through the FEM model, the slip parameter for the control algorithm could be induced effectively. The LIM for the traction system was performed at a constant V/f in the region of constant torque, and a constant V and variable f in the region of constant power. Several slip characteristic curves according to the voltage and frequency were calculated by FEM in advance. The driving performance was then induced by interpolating the slip characteristic curves according to the load of the vehicle.

A study on the slip frequency control of linear induction motor for magnetic levitation transit (자기 부상 열차용 리니어모터의 슬립 주파수 제어에 관한 연구)

  • Im, Dal-Ho;Kim, Gyu-Tak;Kim, Young-Kwan
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.135-138
    • /
    • 1991
  • In this study, a variety of characteristics is considered when LIM for transit is driven with acceleration and deceleration. From the characteristics of constant voltage, with V/f ratio fixed, slip frequency is derived. With slip frequency of 12[Hz] and objective velocity of 40[km/h], the robust control characteristics which are generated constant thrust and normal force, except for open-loop control interval, are obtained.

  • PDF

Intracellular Expression of CTB in Vibrio cholerae Strains in Laboratory Culture Conditions

  • Hunseok Choi;Seonghyeon Son;Donghyun Lee;Jonghyun Bae;Eunyoung Seo;Dong Wook Kim;Eun Jin Kim
    • Journal of Microbiology and Biotechnology
    • /
    • v.33 no.6
    • /
    • pp.736-744
    • /
    • 2023
  • The introduction of the toxT-139F allele triggers the expression of TCP (toxin co-regulated pilus) and CT (cholera toxin) under simple laboratory culture conditions in most Vibrio cholerae strains. Such V. cholerae strains, especially strains that have been used in OCVs (oral cholera vaccines), can induce antibody responses against TCP in animal models. However, CT produced in these V. cholerae strains is secreted into the culture medium. In this study, V. cholerae strains that can express intracellular CTB under the control of the toxT-139F allele have been constructed for potential application in OCVs. First, we constructed a recombinant plasmid directly linking the ctxAB promoter to ctxB without ctxA and confirmed CTB expression from the plasmid in V. cholerae containing the toxT-139F allele. We constructed another recombinant plasmid to express NtrCTB, from which 14 internal amino acids-from the 7th to the 20th amino acid-of the leader peptide of CTB have been omitted, and we found that NtrCTB remained in the cells. Based on those results, we constructed V. cholerae strains in which chromosomal ctxAB is replaced by ntrctxB or ntrctxB-dimer. Both NtrCTB and NtrCTB-dimer remained in the bacterial cells, and 60% of the NtrCTB-dimer in the bacterial cells was maintained in a soluble form. To develop improved OCVs, these strains could be tested to see whether they induce immune responses against CTB in animal models.