• Title/Summary/Keyword: V/UHF

Search Result 101, Processing Time 0.022 seconds

Analysis of Partial Discharge Characteristics in SF6 Gas Insulation (SF6 가스절연에서 부분방전의 특성분석)

  • Kim, Sun-Jae;Wang, Guoming;Park, Seo-Jun;Kil, Gyung-Suk;An, Chang-Hwan
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.7
    • /
    • pp.429-434
    • /
    • 2016
  • This paper deals with the characteristics of partial discharge (PD) for the purpose of a condition based maintenance (CBM) of gas insulated switchgears (GIS) in power equipment. Four types of electrode systems such as a protrusion on enclosure (POE), a particle on spacer (POS), a free particle (FP) and a Floating were designed and fabricated. PD pulses were measured using UHF sensor with a frequency range of 300 MHz~1.4 GHz and a DAQ with a sampling rate of 250 MS/s. Discharge inception voltage (DIV), discharge extinction voltage (DEV), and phase resolved partial discharge (PRPD) were analyzed depending on electrode systems. The average DIV in the POS was 28.8 kV. It was about 1.7 times higher than that in the FP, which was the lowest value of 17.2 kV. The FP shuffled and jumped at the applied voltage of 23.5 kV. Over 95% of PD pulses in the POE were generated in the negative polarity ($181^{\circ}{\sim}360^{\circ}$) of applied voltage. The results showed the phase (${\Phi}$)-magnitude (dBm) of PD pulses by UHF sensor, a cluster was formed separately depending on electrode systems.

Filter Test for Detecting Partial Discharge in 22.9kV XLPE Cable (22.9kV XLPE 케이블 PD 검출용 필터 시험)

  • Lee, Yong-Sung;Kim, Jung-Yoon;Kim, Seok-Jung;Lee, Kyoung-Yong;Choi, Yong-Sung;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2277-2279
    • /
    • 2005
  • Due to a variable noises in the field underground lines, clear technology of noises is very important in the diagnosis technology of partial discharge. Therefore we progressed filter test to improve the measuring test of partial discharge in a field. We applied to field test after making W-LC filter for partial discharge measurement, and then designed experimental environment such as under-ground distribution lines of field. Measuring sensor for test was UHF sensor. And we analysed those using the Lemke Probe and oscilloscope (TDS-3054, Tektronix). Finally, we obtained excellent data of noise decrement in the joint box of 22.9[kV] distribution lines from above experiment.

  • PDF

RFID Tag recognition rate improvement program from metal environment (금속 환경에서 RFID Tag 인식률 실험 및 개선 방안)

  • Jeon, Eun-Man;Cho, Byung-Lok;Kim, Young-Baig
    • 한국IT서비스학회:학술대회논문집
    • /
    • 2009.05a
    • /
    • pp.513-517
    • /
    • 2009
  • 본 논문에서는 UHF대역의 그동안 문제로 되어왔던 일반 태그들의 금속 환경에서의 인식률 저하문제를 태그 패키징(Packaging)을 통해 개선하고자 한다. 다양한 환경에서 실험을 통해 일반태그와 패키징 태그의 인식률의 차이를 실험을 통해 비교해 보았다. 실험결과를 토대로 금속 환경에서 패키징 태그들을 실험 할 수 있는 최적의 태그 실험환경을 구성하여 태그들을 산업현장에서의 테스트와 같은 결과들을 도출하고자 한다.

  • PDF

UHF Band Multi-layer VCO Design Using RF Simulator (RF 시뮬레이터를 이용한 UHF대역 다층구조 VCO 설계)

  • Rhie, Dong-Hee;Jung, Jin-Hwee
    • Proceedings of the KIEE Conference
    • /
    • 2001.11a
    • /
    • pp.96-99
    • /
    • 2001
  • In this paper, we present the simulation results of the multi-layer VCO(Voltage Controlled Oscillator), which is composed of the resonator, the oscillator and the buffer circuit. using EM simulator and nonlinear RF circuit simulator. EM simulator is used for obtaining the EM(Electromagnetic) characteristics of the conductor pattern as well as designing the multi-layer VCO. Obtained EM characteristics were used as real components in nonlinear RF circuit simulation. Finally the overall VCO was simulated using the nonlinear RF circuit simulator. The material for the circuit pattern was Ag and the dielectric was DuPont 951AT, which will be applied for LTCC process. The structure is constructed with 4 conducting layer. Simulated results showed that the output level was about 4.5[dBm], the phase noise was -104[dBc/Hz] at 30[kHz] offset frequency, the harmonics -8dBc, and the control voltage sensitivity of 30[MHz/V] with a DC current consumption of 9.5[mA]. The size of VCO is $6{\times}9{\times}2mm$(0.11[cc]).

  • PDF

High quality fast growth nano-crystalline Si film synthesized by UHF assisted HF-PECVD

  • Kim, Youn-J.;Choi, Yoon-S.;Choi, In-S.;Han, Jeon-G.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.306-306
    • /
    • 2010
  • A high density (> $10^{11}\;cm^{-3}$) and low electron temperature (< 2 eV) plasma is produced by using a conventional HF (13.56 MHz) plasma enhanced chemical vapor deposition (PECVD) with an additional ultra high frequency (UHF, 314 MHz) plasma source utilizing two parallel antenna assembly. It is applied for the high rate synthesis of high quality nanocrystalline silicon (nc-Si) films. A high deposition rate of 1.8 nm/s is achieved with a high crystallinity (< 70%), a low spin density (< $3{\times}10^{16}\;cm^{-3}$) and a high light soaking stability (< 1.5). Optical emission spectroscopy measurements reveal emission intensity of $Si^*$ and $SiH^*$, intensity ratio of $H{\alpha}/Si^*$ and $H{\alpha}/SiH^*$ which are closely related to film deposition rate and film crystallinity, respectively. A high flux of precursor and atomic hydrogen which are produced by an additional high excitation frequency is effective for the fast deposition of highly crystallized nc-Si films without additional defects.

  • PDF

Performance verification and improvement of the frequency analysis unit for GIS Preventive & Diagnostic Monitoring System (GIS 예방진단시스템 주파수 분석장치 성능개선 및 검증)

  • Kim, Won-Gyu;Kim, Min-Soo;Baek, Young-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.3
    • /
    • pp.485-491
    • /
    • 2015
  • This paper shows the design improvement and test model of FAU (Frequency Analysis Unit) in PDD (Partial Discharge Diagnosis system) for 800kV GIS (Gas Insulated Switchgear). We found some problems during operation of previous FAU, such as the aging of fiber-optic converter that can cause communication error, the malfunction of signal analysis circuit etc. And then we solved those problems by design improvement and verified the performance through type test. To monitor partial discharge, the performance of UHF sensor is important but the performance of frequency analysis unit is also very important. So we solved communication error, the malfunction of signal analysis circuit and then increased the operation reliability of FAU by improving fiber-optic converter and signal analysis circuit. Accredited testing laboratory carried out the performance verification test according to performance test criteria and procedure of reliability test standards, IEC-60225, 61000 and 60068 etc. We confirmed the test results which correspond with the performance test criteria.

The Design of Stack Structure Antenna Using the U-Slot patch for 800MHz Multiple Band Applications (U-Slot 패치를 이용한 800MHz 다중대역용 적층구조)

  • Park, Jung-Ah;Yoon, Chi-Moo;Kim, Kab-Ki
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2008.05a
    • /
    • pp.121-124
    • /
    • 2008
  • In this paper, we will design a 800MHz broadband antenna after a problem of the narrow bandwidth is improved. This multiple band antenna unifies the CDMA(Code Division Multiple Access), GSM(Global System for Mobile telecommunication) and TRS(Trunked Radio System) band in the UHF bandwidth, and then it is possible at the shore base station or repeater as the commercial use. It used the duplex resonance effect It had the L-shaped feeding structure which adds the V-slot. And it improved profit using stack structure. It was measured that the frequency bandwidth of the designed antenna which is planed $792{\sim}1040MHz$ with 248MHz(33%). And the antenna gain is 9.4dBi, 3dB beam width $60^{\circ}$ in radiation pattern.

  • PDF

Design of a Wideband Frequency Synthesizer with Low Varactor Control Voltage (낮은 바렉터 제어 전압을 이용한 광대역 주파수 합성기 설계)

  • Won, Duck-Ho;Choi, Kwang-Seok;Yun, Sang-Won
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.1
    • /
    • pp.69-75
    • /
    • 2010
  • In this paper, with using the clapp type VCO(Voltage Controlled Osillator) configuration a wideband frequency synthesizer in UHF band is proposed. In order to design a wideband frequency synthesizer, the variation of phase in the negative resistance circuit as well as the load circuit was analyzed. Based on this result we propose a method to widen the operation range of the VCO. A frequency synthesizer using the proposed wideband VCO was designed and fabricated. It is shown that the synthesizer has the operating frequency range of 740~1,530 MHz by 0~5 V varactor tuning voltage, and it had the output power of 2~-6 dBm. Moreover, the phase noise measured as -77 dBc/Hz at 10 kHz offset, and as -108 dBc/Hz at 100 kHz offset from the oscillation frequency.

Next-Generation Intelligent Radio Monitoring System (차세대 지능형 전파감시 시스템)

  • Yim, Hyun-Seok;Moon, Jin-Ho;Kim, Kyung-Seok
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.8A
    • /
    • pp.846-851
    • /
    • 2008
  • With rapid development of communication industry, the kinds of communication service vary. According to the increasing use of radio waves, the intelligent and effective radio monitoring system needs to be developed, which is replaced for previous radio monitoring system. Next-generation intelligent radio monitoring system based on ITU-R, Rule of wireless facilities, and Radio Waves Act is used, and which can accurately and effectively function as effective radio monitoring system through spectrum analysis of channel power, frequency deviation, offset, and an occupied frequency bandwidth(99% or x-dB), about the analog and digital signal in On-Air of V/UHF bandwidth. Main function of the system has an radio quality measurement, unwanted electromagnetic signals (spurious, harmonic) measurement, high-speed spectrum measurement, frequency usage efficiency investigation, illegal radio exploration, working monitoring, In this paper, we proposes radio quality measurement, high-speed spectrum measurement of next-generation intelligent radio monitoring system.

Comparison of The Attenuation Measurement Methods for Electromagnetic Partial Discharge Signal in 25.8 kV Gas Insulated Switchgear (25.8 kV GIS에서 전자기파 부분방전신호 감쇠특성 측정방법 비교)

  • Goo, Sun-Geun;Han, Ki-Sun;Kwak, Joo-Sik;Joo, Hyung-Jun;Jeong, Moon-Gyu
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.9
    • /
    • pp.1281-1287
    • /
    • 2015
  • We report the characteristics and differences of two types of attenuation measurement methods for electromagnetic partial discharge signal in GIS. The pulse method is to measure the attenuated waveforms in time domain and coverts them into frequency domain to get the attenuation spectra of given GIS section. This method simulates the real partial discharge signal. The frequency swept continuous wave method can obtain attenuation spectra directly so that it gives attenuation with low noise floor and simplicity. We show that both methods are effective and exchangeable because the attenuation results measured by two methods have similar trends