• 제목/요약/키워드: Useful storage

Search Result 776, Processing Time 0.034 seconds

Genome-Wide Association Study of Bone Mineral Density in Korean Men

  • Bae, Ye Seul;Im, Sun-Wha;Kang, Mi So;Kim, Jin Hee;Lee, Soon Hang;Cho, Be Long;Park, Jin Ho;Nam, You-Seon;Son, Ho-Young;Yang, San Deok;Sung, Joohon;Oh, Kwang Ho;Yun, Jae Moon;Kim, Jong Il
    • Genomics & Informatics
    • /
    • v.14 no.2
    • /
    • pp.62-68
    • /
    • 2016
  • Osteoporosis is a medical condition of global concern, with increasing incidence in both sexes. Bone mineral density (BMD), a highly heritable trait, has been proven a useful diagnostic factor in predicting fracture. Because medical information is lacking about male osteoporotic genetics, we conducted a genome-wide association study of BMD in Korean men. With 1,176 participants, we analyzed 4,414,664 single nucleotide polymorphisms (SNPs) after genomic imputation, and identified five SNPs and three loci correlated with bone density and strength. Multivariate linear regression models were applied to adjust for age and body mass index interference. Rs17124500 ($p=6.42{\times}10^{-7}$), rs34594869 ($p=6.53{\times}10^{-7}$) and rs17124504 ($p=6.53{\times}10^{-7}$) in 14q31.3 and rs140155614 ($p=8.64{\times}10^{-7}$) in 15q25.1 were significantly associated with lumbar spine BMD (LS-BMD), while rs111822233 ($p=6.35{\times}10^{-7}$) was linked with the femur total BMD (FT-BMD). Additionally, we analyzed the relationship between BMD and five genes previously identified in Korean men. Rs61382873 (p = 0.0009) in LRP5, rs9567003 (p = 0.0033) in TNFSF11 and rs9935828 (p = 0.0248) in FOXL1 were observed for LS-BMD. Furthermore, rs33997547 (p = 0.0057) in ZBTB and rs1664496 (p = 0.0012) in MEF2C were found to influence FT-BMD and rs61769193 (p = 0.0114) in ZBTB to influence femur neck BMD. We identified five SNPs and three genomic regions, associated with BMD. The significance of our results lies in the discovery of new loci, while also affirming a previously significant locus, as potential osteoporotic factors in the Korean male population.

Composite Oxidizing Agents Generation Using Electrolysis of Dilute Hydrochloric Acid (묽은 산 전기분해에 의한 복합 산화제 생성)

  • Kang, Shin-Young;Park, Jong-Hun;Kim, Sang-Hyoun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.6
    • /
    • pp.329-333
    • /
    • 2016
  • Disinfection by electrolysis would be useful for small wastewater treatment plant, combined sewer overflow, ballast water, swimming pool, and fish farming, where the transport, storage, and the use of chlorine gas is limited. This study investigated the feasibility of the electrolysis of dilute hydrochloric acid (HCl) for disinfection. The effects of HCl concentration, voltage and reaction time on the generation of oxidizing agents, HOCl, $O_3$, and $H_2O_2$, were examined in a series of batch test. The highest current efficiency was 99.3% which was found at 2.2%, 3 V, and 5 min of HCl concentration, voltage, and reaction time, respectively. Continuous electrolysis at 2.2% HCl, 3 V, and 5 min of the hydraulic retention time showed 97.4% of the current efficiency. Addition of sodium chloride up to 20 g/L linearly increased the oxidizing agents production. 92.2% of total coliforms were removed by the contact with the electrolyzed water.

Current Status and Characterization of CANDU Spent Fuel for Geological Disposal System Design (심지층 처분시스템 설계를 위한 중수로 사용후핵연료 현황 및 선원항 분석)

  • Cho, Dong-Keun;Lee, Seung-Woo;Cha, Jeong-Hun;Choi, Jong-Won;Lee, Yang;Choi, Heui-Joo
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.6 no.2
    • /
    • pp.155-162
    • /
    • 2008
  • Inventories to be disposed of, reference turnup, and source terms for CANDU spent fuel were evaluated for geological disposal system design. The historical and projected inventory by 2040 is expected to be 14,600 MtU under the condition of 30-year lifetime for unit 1 and 40-year lifetime for other units in Wolsong site. As a result of statistical analysis for discharge burnup of the spent fuels generated by 2007, average and stand deviation revealed 6,987 MWD/MtU and 1,167, respectively. From this result, the reference burnup was determined as 8,100 MWD/MtU which covers 84% of spent fuels in total. Source terms such as nuclide concentration for a long-term safety analysis, decay heat, thermo-mechanical analysis, and radiation intenity and spectrum was characterized by using ORIGEN-ARP containing conservativeness in the aspect of decay heat up to several thousand years. The results from this study will be useful for the design of storage and disposal facilities.

  • PDF

Remediation of Petroleum-Contaminated Soil by a Directly-Heated Thermal Desorption Process (직접 가열식 열탈착 공정을 이용한 유류오염토양의 정화)

  • Min, Hyeong-Sik;Yang, In-Ho;Jeon, Sang-Jo;Kim, Han-S.
    • Journal of Soil and Groundwater Environment
    • /
    • v.14 no.5
    • /
    • pp.62-70
    • /
    • 2009
  • A field soil highly contaminated with petroleum hydrocarbons (JP-8 and diesel fuels) was employed for its remediation by a lab-scale thermal desorption process. The soil was collected in the vicinity of an underground storage tank in a closed military base and its contamination level was as high as 4,476 ppm as total petroleum hydrocarbon (TPH). A lab scale directly-heated low temperature thermal desorption (LTTD) system of 10-L capacity was developed and operated for the thermal treatment of TPH contaminated soils in this study. The desired operation temperature was found to be approximately $200-300^{\circ}C$ from the thermal gravimetric analysis of the contaminated field soils. The removal efficiencies higher than 90% were achieved by the LTTD treatment at $200^{\circ}C$ for 10 min as well as at $300^{\circ}C$ for 5 min. As the water content in the soils increased and therefore they were likely to be present as lumps, the removal efficiency noticeably decreased, indicating that a pre-treatment such as field drying should be required. The analysis of physical and chemical properties of soils before and after the LTTD treatment demonstrated that no significant changes occurred during the thermal treatment, supporting no needs for additional post-treatments for the soils treated by LTTD. The results presented in this study are expected to provide useful information for the field application and verification of LTTD for the highly contaminated geo-environment.

Effect of Acupuncture at ST36 on Ischemia-induced Learning and Memory Deficits in Gerbils

  • Chung, Jin-Yong;Park, Hyun-Jung;Shim, Hyun-Soo;Hahm, Dae-Hyun;Kim, Hee-Young;Lee, Hye-Jung;Kim, Kyung-Soo;Shim, In-Sop
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.25 no.2
    • /
    • pp.300-305
    • /
    • 2011
  • The present study was investigated the neuroprotective effects of acupuncture at ST36 on learning and memory deficits after transient cerebral ischemia in a gerbil model. The animals were randomly divided into three groups (n=7 in each group): the sham operation group (SHAM), ischemia-induced and ST36 acupuncture group (ISC + ST36), and the ischemia-induced and Tail-acupuncture group (ISC + TAIL). For the acupuncture stimulation, stainless steel needles, 0.3 mm in diameter, were inserted bilaterally into the ST36 locus or the tail and stimulated for 1 min/day for 14 days. Using the Morris water maze test, the animals were tested on spatial learning and memory. In addition, the effects of acupuncture on memory storage and the choline acetyltransferase (ChAT) activity, in the hippocampal CA1 area, were investigated by ChAT immunohistochemistry. Transient cerebral ischemia produced impaired performance on the MWM test (DAY 5: p<0.01 and retention test: p<0.05) and severely decreased ChAT immunoreactivity in the CA1 hippocampal area compared to the SHAM group (p<0.05). However, improved learning and memory were observed (DAY 5: p<0.05 and retention test: p<0.01) as well as a significantly reduced loss of ChAT immunoactivity in the hippocampal CA1 region (p<0.001) after acupuncture stimulation at ST36 were observed. These results show that acupuncture at ST36 ameliorated the learning and memory deficits at least in part through the cholinergic system. The findings of this study provide potential data that acupuncture is useful for the treatment of some of the behavioral impairs of transient cerebral ischemia.

An experimental study on the operation mode of rapid flooding protection system in tunnel (축소모형실험을 통한 터널 내 급속침수 차폐자동화 시스템 작동형태에 대한 연구)

  • Kim, Yeon-Deok;Kong, Min-Teak;Hwang, Beoung-Hyeon;Kim, Sang-Hwan
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.6
    • /
    • pp.1147-1159
    • /
    • 2018
  • This study focuses on the verification of a rapid protection automation system using an inflatable structure. The inflatable structure is an automatic rapid protection system against human and material damage when the subsea tunnel is flooded. Especially, it is essential for construction and operation of subsea tunnels. In this study, we have experimentally verified the rapid protection automation system using the inflatable structure designed for this problem. In order to verify this, a model tunnel with a 40: 1 reduction ratio was constructed, and air pressure of 0.1 bar and 0.15 bar was injected to divide the tunnel according to the expansion rate at 10 sec and 20 sec. According to the results of the study, the protection efficiency was better at 0.15 bar than 0.1 bar when the expansion structure was expanded, and the protection efficiency and influent control efficiency were different according to the pneumatic injection time of the inflating structure. As a result of this study, it was found that the higher the internal air pressure of the inflated structure and the faster the inflation of rate, the more effectively the inflated structure was inflated. As a result of this study, it is necessary to further study the wedge type structure which is useful for the storage method of expansion structure, shape and expansion derivative, inhibition of expansion structure during protection and control of inflow water.

The Study on the Fire Monitoring Dystem for Full-scale Surveillance and Video Tracking (전방위 감시와 영상추적이 가능한 화재감시시스템에 관한 연구)

  • Baek, Dong-hyun
    • Fire Science and Engineering
    • /
    • v.32 no.6
    • /
    • pp.40-45
    • /
    • 2018
  • The omnidirectional surveillance camera uses the object detection algorithm to level the object by unit so that broadband surveillance can be performed using a fisheye lens and then, it was a field experiment with a system composed of an omnidirectional surveillance camera and a tracking (PTZ) camera. The omnidirectional surveillance camera accurately detects the moving object, displays the squarely, and tracks it in close cooperation with the tracking camera. In the field test of flame detection and temperature of the sensing camera, when the flame is detected during the auto scan, the detection camera stops and the temperature is displayed by moving the corresponding spot part to the central part of the screen. It is also possible to measure the distance of the flame from the distance of 1.5 km, which exceeds the standard of calorific value of 1 km 2,340 kcal. In the performance test of detecting the flame along the distance, it is possible to be 1.5 km in width exceeding $56cm{\times}90cm$ at a distance of 1km, and so it is also adaptable to forest fire. The system is expected to be very useful for safety such as prevention of intrinsic or surrounding fire and intrusion monitoring if it is installed in a petroleum gas storage facility or a storing place for oil in the future.

Antioxidant Effect of Anserine Extracted from Salmon (Oncorhynchus keta) (연어(Oncorhynchus keta) 추출 anserine의 항산화 효과)

  • Min, Hye-Ok;Song, Ho-Su
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.4
    • /
    • pp.396-403
    • /
    • 2019
  • Ion-exchange chromatography and ultrafiltration were used to extract anserine from salmon (Oncorhynchus keta). The salmon anserine showed DPPH radical scavenging activity in the range of 7.30% to 31.05% in a dose-dependent manner. This reducing power of salmon anserine also increased as the concentration increased. Metal chelate activity, superoxide dismutase - like activity, and thiobarbituric acid reactive substances assay showed similar results. The anserine also suppressed the increment of the peroxide value and linoleic acid during storage periods. These results suggest that salmon anserine might be useful as a natural antioxidant in various foodstuffs.

Perceptions and Practices of Employees Regarding Email Records Management in Universities: A Case Study of D University (대학의 이메일 기록관리 실태와 조직구성원들의 인식: D대학을 사례로)

  • Park, Yu Jin;Jung, Young Mi
    • Journal of Korean Society of Archives and Records Management
    • /
    • v.19 no.2
    • /
    • pp.193-211
    • /
    • 2019
  • With the increasing number of business email, there is a growing need to manage email records. Before the development of email records management measures, this study aimed to investigate the status of email records management in universities and determine employees' perceptions of email records management. Surveys and interviews were conducted with professors, staff, and assistants who use groupware accounts at D University, and their overall perceptions of email records management and the status of email record management, such as email production, deletion, archival, and backup of university members were gathered. A total of 185 people responded to the survey, and 12 of them were interviewed. According to the analysis, the public utilization of email was frequent, and the management of emails, such as backup and retention, was not performed well compared to deletion and storage. In addition, email is still perceived as private, and users recognize the need for email records management, but they still perceive that they are responsible for records management. The results of this study will be useful in setting the policy for email records management of universities and will help provide email record management awareness.

A Review of In-Situ Characterization and Quality Control of EDZ During Construction of Final Disposal Facility for Spent Nuclear Fuel (사용후핵연료 최종처분장 건설과정에서의 굴착손상영역(EDZ)의 현장평가 방법 및 시공품질관리 체계에 관한 사례검토)

  • Kim, Hyung-Mok;Nam, Myung Jin;Park, Eui-Seob
    • Tunnel and Underground Space
    • /
    • v.32 no.2
    • /
    • pp.107-119
    • /
    • 2022
  • Excavation-Disturbed Zone (EDZ) is an important design factor in constructing final disposal facilities for spent nuclear fuel, since EDZ affects mechanical stability including a spacing between disposal holes, and the hydraulic properties within EDZ plays a significant role in estimating in-flow rate of groundwater as well as a subsequent corrosion rate of a canister. Thus, it is highly required to characterize in-situ EDZ with precision and control the EDZ occurrence while excavating disposal facilities and constructing relevant underground research facilities. In this report, we not only reviewed EDZ-related researches carried out in the ONKALO facility of Finland but also examined appropriate methods for field inspection and quality control of EDZ occurrence. From the review, GPR can be the most efficient method for in-situ characterization of EDZ since it does not demand drilling a borehole that may disturb a surrounding environment of caverns. And the EDZ occurrence was dominant at a cavern floor and it ranged from 0 to 70 cm. These can provide useful information in developing necessary EDZ-related regulations for domestic disposal facilities.