• Title/Summary/Keyword: Urban Environmental Design

Search Result 905, Processing Time 0.129 seconds

Determination of Optimal Livestock Wastewater Treatment Process for Linked Treatment in Sewage Treatment Plant (하수처리장 연계처리를 위한 가축분뇨 최적 처리공정 선정에 관한 연구)

  • Kim, Choong Gon;Shin, Hyun Gon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.20 no.3
    • /
    • pp.52-59
    • /
    • 2012
  • As the result of reviewing the linked treatment of water quality for treating process at public livestock wastewater treatment facilities for fair selection of the proper linked process in case of linking sewage treatment plant for livestock wastewater, in case of wastewater processed by bio-reactor that is only biologically-treated, the load factor showed relatively high as 1.67%(base on design quality), 2.59%(base on operation quality) regarding COD and 3.69%(base on design quality), 7.67%(base on operation quality) regarding $COD_{Mn}$ but it is judged that there is nearly no influence on the operation of sewage treatment plan. And, in case of oxidized flotation-treated water & biofiltlation-treated water that are the advanced wastewater treatment, the load factor is approximately 1% and there is concern about the installation of excessive facilities in case of installing the advanced wastewater treatment. So, in case of considering the economic efficiency & stable operation of sewage treatment plant S, it is judged to be desirable to link with wastewater processed by bio-reactor that is biologically-treated.

Explicit Equations of Normal Depth for Drainage Pipes (하수관 등류수심 양해법 산정식)

  • Yoo, Dong-Hoon;Rho, Jung-Soo
    • Journal of Korea Water Resources Association
    • /
    • v.38 no.7 s.156
    • /
    • pp.527-535
    • /
    • 2005
  • The computation of normal depth is very important for the design of channel and the analysis of water flow. Drainage pipe generally has the shape of curvature like circular or U-type, which is different from artificial triangular or rectangular channel. In this case, the computation of normal depth or the derivation of equations is very difficult because the change of hydraulic radius and area versus depth is not simple. If the ratio of the area to the diameter, or the hydraulic radius to the diameter of pipe is expressed as the water depth to the diameter of pipe by power law, however, the process of computing normal depth becomes relatively simple, and explicit equations can be obtained. In the present study, developed are the explicit normal depth equations for circular and U-type pipes, and the normal depth equation associated with Hagen (Manning) equation and friction factor equation of smooth turbulent flow by power law is also proposed because of its wide usage in engineering design.

Utilization of Mean Shear Wave Velocity to a Depth Shallower than 30m for Efficient Seismic Site Classification in Korea (우리나라 지진공학적 지반 분류를 위한 30m 미만 심도 평균 전단파 속도의 활용)

  • Sun, Chang-Guk;Chung, Choong-Ki;Kim, Dong-Soo
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.562-571
    • /
    • 2006
  • Mean shear wave velocity of the upper 30m $(V_s30)$ used as the current site classification criterion for determining seismic design ground motions in Korea was established based on the typical depth of site investigations in western US, in which the depth to bedrock is much deeper than that in Korea. In this study, to establish appropriate site classification system for site conditions of Korea, site investigations including in-situ seismic tests to determine shear wave velocity $(V_s)$ were carried out at total 72 sites in Korean peninsula. The mean $V_s's$ to the depths of 5m, 10m, 15m, 20m and 25m together with the $V_s30$ at the testing sites were determined, and the correlation between the mean $V_s$ to a depth shallower than 30m and the $V_s30$ was drawn and suggested for the efficient seismic site classification in Korea. The proposed correlation could be utilized for the seismic design in case of the $V_s$ profiles shallower than 30 m in depth. The correlation in this study, nevertheless, requires further modification by means of the accumulation of various site data in Korea.

  • PDF

Evaluation of Structural Performance of Precast Modular Pier Cap (프리캐스트 모듈러 피어캡의 구조성능 평가)

  • Kim, Dong Wook;Shim, Chang Su
    • Journal of the Korea Concrete Institute
    • /
    • v.27 no.1
    • /
    • pp.55-63
    • /
    • 2015
  • Prefabrication technologies are making bridge construction safer and less disruptive to the environment and traveling public, making bridge designs more constructible and, improving the quality and durability by shifting site work to a more controllable environment. Modular bridge substructures with concrete-filled steel tube (CFT) piers and composite pier caps were suggested to realize accelerated bridge construction. The precast segmental pier cap consists of a composite pier table and precast prestressed segments on the table. The pier table has embedded steel section to mitigate stress concentration at the connection by small tubes. Each bridge pier has four or six CFT columns which connect to the pier cap. Shear strength of the pier cap was obtained by extending vertical reinforcing bars from the table to the precast segment. Transverse prestressing was introduced to control tensile stresses by service loadings. Structural performance of the proposed modular system was evaluated by static tests. Design requirements of the composite pier cap were satisfied by continuous reinforcing bars and prestressing tendons. Standardized modular substructures can be effectively utilized for the fast replacement or construction of bridges.

Flooding Risk Assessment Using Flooding Characteristic Values (침수특성치를 이용한 침수위험성 평가)

  • Ahn, Jeonghwan;Kim, Kunwoo;Cho, Woncheol
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.3
    • /
    • pp.957-964
    • /
    • 2013
  • This research is on the methodology of flood risk assessment using flooding characteristic values. Necessity of design magnitude for flood control considering floods was judged by plotting peak flow with respect to frequency and duration, and flooding magnitude was defined with 6 flooding characteristic values which were proposed to be significant factors when assessing flooding magnitude. Precipitation data used in the assessment modeling were applied by combining all the possible precipitation events. After overlapping the simulated results with precipitation matrix by flooding characteristic values, contour map was drawn, and Flooding characteristic contour graph for possible rainfall events were suggested in respect of all possible precipitation. Flooding characteristic contour graph for possible rainfall events was confirmed that reducing of damage magnitude of each flood characteristic value was figured out easily. The flood risk assessment methods suggested in this study would be a good reference for urban drainage system design, which only focuses on pipe conduit.

A Study on Characteristics of Geomorphic Landscape and Its Usage of 'Oreurn' on Jeju-Island (제주 '오름'의 지형경관 특성과 활용방안)

  • Suh, Joo-Hwan;Rho, Jae-Hyun;Kim, Sang-Beom
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.35 no.4
    • /
    • pp.57-70
    • /
    • 2007
  • As a basic element of Jeju landscape, Oreum offers a beautiful and aesthetic view. Considering topographical and geological research achievements, however, an effort to discover implicit value in terms of landscape characteristics and value has been ignored. This paper has investigated the characteristics and value of landscape by Oreum focusing on Jeju landscape characteristics and eco-touristic value and discussed a scheme to maximize the values. Under a theme of 'Sustainable Development' of the RIO Declaration, tour industry has recently changed its focus from eco-tourism to gee-tourism. Fortunately, Jeju Oreum has very distinctive and unique landscape with depressed crater at a crest. Nevertheless, it's very difficult to see a true aspect of Oreum from the street or over the car window. Therefore, it's urgent to begin a research on how to make advantage of and preserve Oreum landscape in order to maximize its landscape values and improve its potential as a tourist attraction. Through diverse programs such as sky leisure sports(ex: light airplane and helicopter riding, paragliding), sky watching, and mountain hiking, in particular, a possibility that Oreum can succeed as LBD(Learning by Doing)-based tour program with volcanic features needs to be examined. Besides, it's also a good idea to develop Oreum tour program or Oreum Museum as an alternative plan. Above all, however, it's most urgent to protect the existing Oreum and restore ecological and landscape beauty of Oreum through proper land use.

Hydraulic model test for corrugated artificial reef stability (수리실험을 통한 요철형 인공어초 안정성 검토)

  • Baek, Seung Hwa;Shin, Bum-Shick;Kim, Kyu-Han
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.8
    • /
    • pp.5327-5332
    • /
    • 2014
  • In Korea, the quantitative growth rate of artificial reef construction is supposed to reach the peak point. Therefore, new approach is needed to the point of artificial reefs business. Functional reefs, such as shellfish reefs, recreational reefs, seaweed reefs, and fish reefs, are beneficial alternatives. This study conducted hydraulic testing to assess the stability of corrugated artificial reefs (ARs) that were constructed to promote the growth of shellfish and seaweed. The results of this study showed that some dimensionless design parameters affected the stability of corrugated artificial reefs under a range of wave and water depth conditions in a fixed bed condition. The findings also highlight the importance of hydraulic experiments in solving the problems that have emerged in the design and construction of artificial reefs.

A Study on Sustainable Outdoor Space of Regional Public Hospitals (지역거점공공병원의 지속가능한 외부공간에 대한 연구)

  • Yoon, Eunji;Lim, Yeonghwan
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.23 no.4
    • /
    • pp.17-25
    • /
    • 2017
  • Purpose: Since hospitals have a big impact on the natural and social environment, hospitals' sustainability must be considered in various aspects including environmental, social, and economical aspects. So far, research on sustainable hospitals has mainly been conducted on indoor environment, but outdoor space of hospital is as important as well. The purpose of this research is to study the sustainability of hospital outdoor space and to make proposals for improving sustainable regional public hospitals. Methods: Through preceding research analysis and literature review, the concept of sustainable outdoor space of hospital was defined. Also, the evaluation contents of outdoor space were extracted from domestic and foreign green building certification criteria. With this analytic frame, we visited 4 regional public hospitals in Korea, interviewed the facility managers, and analyzed sustainability of hospital outdoor space. Results: Analysis of 4 regional public hospitals reveals that there is a lack of consideration for sustainability in all 4 categories; urban and network, natural environment, community, and user. In terms of community, sustainability has rarely been applied to all four hospitals. The site selection and terrain of the site were essential to sustainability. Implications: Establishing a master plan considering future expansion is critical. Also more attempt to show regional characteristics is needed. It is necessary to design a comprehensive outdoor space that considers sustainability and also healing environment. Level difference in the site can be used as a design element.

The Effects of Neighborhood Physical Changes caused by CPTED Project on Resident's Fear of Crime, Neighborhood Satisfaction, and Neighborhood Attachment in the Poverty Area - Focused on the Gamcheon 2-dong, Saha-gu, Busan - (CPTED 사업으로 인한 근린의 물리적 환경변화가 빈곤지역 주민들의 범죄두려움과 동네만족도, 동네애착 형성에 미치는 영향 - 부산 사하구 감천2동을 대상으로 -)

  • Park, Ju-Hyeon;Lee, Kyung-Hwan
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.36 no.1
    • /
    • pp.105-111
    • /
    • 2020
  • The purpose of this study was to empirically analyze the effects of physical environment change on the Crime Prevention Through Environmental Design (CPTED) project implemented in Gamcheon 2 Dong on the fear of crime, neighborhood satisfaction, and neighborhood attachment in the poor. In this study, the data collected through field surveys and questionnaires were analyzed using a structural equation model, specifically the SPSS AMOS 25 program. From the results of the analysis, it was found that the neighborhood satisfaction was enhanced by the improvement in the walking environment and the reduction in the neighborhood disorder level of the target area through the installation of major CPTED facilities. The results of the statistical analysis show that the reduction in the neighborhood disorder due to the CPTED project enhanced the neighborhood satisfaction and the level of neighborhood attachment in the local residents. In addition, the changes in the walking environment caused by the CPTED project had a positive effect on the neighborhood satisfaction, and as the degree of neighborhood disorder decreased, the neighborhood satisfaction increased and the local people's attachment level increased.

Evaluation on De-Icing Salts Laden Environment of Road in Seoul (제설제에 노출된 서울시내 도로 시설물의 열화 환경 분석)

  • Yoon, In-Seok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.1
    • /
    • pp.1-9
    • /
    • 2022
  • De -icing salts have been used commonly in areas where snow or ice is a seasonal safety hazard for roadway, however, the salts is one of main causes on serious deterioration of road infrastructures in crowded urban city like Seoul. In order to establish maintenance strategy of road infrastructures under de-icing salts laden environment, it is necessary to examine environmental characteristics and its response to the existing facilities. The purpose of this study is to evaluate the deterioration environment of road infrastructures. Additional purpose is to develop a design model and details for durability design of infrastructures under de-icing salts laden environment, considering mainly a build-up rate of surface chlorides. Concentration of external chloride solution and surface chloride content were calculated at the level of average de-icing salts for 5 years, ratio of auxiliary road of 17.5 to 30%, and effective exposure area to snow 50 to 80%. The chloride build-up rate was 0.073 ~ 0.077% / year and the maximum surface chloride content was calculated to be 2.2 ~ 2.31% by concrete wt. This study is expected to be used for establishing integrated strategy of road infrastructures, such as predicting chloride profiles or degree of chemical corrosion to exposure concrete.