• 제목/요약/키워드: Union Type

검색결과 245건 처리시간 0.027초

전위된 관절 내 종골 골절의 Ollier 접근법을 이용한 치료 (Treatment of Displaced Intra-articular Calcaneal Fracture using Ollier Approach)

  • 김근우;조상기;이동연
    • 대한족부족관절학회지
    • /
    • 제12권2호
    • /
    • pp.174-179
    • /
    • 2008
  • Purpose: We evaluated the clinical results of the intraarticular calcaneal fractures treated using Ollier approach by inexperienced orthopaedic surgeon. Materials and Methods: Between August 2003 and May 2007, Of the total 46 cases, 12 cases (9 patients) of displaced intraarticular calcaneal fracture who underwent open reduction and internal fixation using Ollier approach were evaluated. The means of age was 50.5 years. According to the Sanders classification, there was no type I case and 8 cases of type II, 1 case of type III, and 3 cases of type IV. We evaluated the treatment result by assessing radiologic parameters ($B{\ddot{o}}hler$ angle, Gissane angle, and calcaneal height/width) and clinical outcomes (VAS and AOFAS score). Results: The means of follow-up period was 25.3 months. The means of B.hler angle was improved from $2.4^{\circ}$ to $26.1^{\circ}$. Radiologic and clinical union was achieved in all cases without additional procedures. Excellent result were noted in 2 cases, good in 5 cases, fair in 4 cases, and poor in 1 case. We experienced 2 cases of minor complications; 1 case of mild wound infection and 1 case of hypoesthesia on foot dorsum. Radiologic findings of subtalar arthritis were present in 2 cases. Conclusion: Ollier approach seems to be helpful to inexperienced orthopaedic surgeons for the treatment of intraarticular calcaneal fractures in that it enables them to achieve considerable clinical outcomes without serious complications.

  • PDF

국내 공동브랜드 운영현황과 활성화 전략 (Domestic co-branded operating status and activation strategies)

  • 김구성;유승엽
    • 디지털융복합연구
    • /
    • 제11권3호
    • /
    • pp.189-197
    • /
    • 2013
  • 최근 경쟁력이 약한 중소기업들은 브랜드 파워와 마케팅 능력을 강화시킬 수 있는 공동브랜드에 대한 관심이 높아지고 있다. 이러한 상황에서 본 연구에서는 국내 공동브랜드의 운영현황을 고찰하고 활성화 전략을 제시하고자 하는 목적에서 이루어졌다. 먼저, 공동브랜드 개념을 다양한 측면에서 알아보고, 공동브랜드의 장, 단점을 살펴보았다. 둘째, 공동브랜드의 유형별을 협동조합형, 기업간 연합형, 선도기업 주도형 및 민 관 합작형 공동브랜드로 구분하여 각각의 장단점을 살펴보았다. 셋째, 국내 주요 공동브랜드의 현황을 제시하였다. 넷째, 중소기업청 지원 공동브랜드의 현황을 살펴보았다. 이를 위해 연도별 지원현황을 살펴보고, 공동상표 업종별 분포 현황 및 공동브랜드 중단유형에 대해 세부적으로 살펴보았다. 끝으로 이러한 자료를 근거로 국내 공동브랜드 활성화 전략을 단기적 측면과 중장기적 측면에서 제시하였다. 본 연구결과는 향후 국내 공동브랜드 사업의 개선방안을 모색하는데 토대가 될 것으로 정부의 지원제도를 마련하는데 도움이 될 것으로 기대한다.

종골의 관절 내 골절에서 외측 광범위 도달법을 이용한 F형 금속판 고정술과 잠김 금속판 고정술의 비교 (Comparison of F Calcaneal Plate and Locking Calcaneal Plate Fixation Using an Lateral Extensile Approach to Intra-articular Calcaneal Fractures)

  • 이윤태;오현철;윤한국;장재원;장기준
    • 대한족부족관절학회지
    • /
    • 제16권3호
    • /
    • pp.175-180
    • /
    • 2012
  • Purpose: To evaluate the radiological and clinical results after open reduction and internal fixation with calcaneal F plate and locking calcaneal plate using lateral extensile approach in the treatment of intra-articular calcaneal fracture Materials and Methods: This study included 34 cases of 33 patients followed up for at least 6 months postoperatively. F plate was applied in 18 cases (Group 1), locking plate was used in 16 cases (Group 2) and compared radiological and clinical results between two groups. Results: Radiollogically, the mean Bohler angle was improved from $5.5^{\circ}$ preoperatively to $20.1^{\circ}$ postoperatively and $18.8^{\circ}$ at the last follow up in group 1 and $8.6^{\circ}$ preoperatively, $21.4^{\circ}$ postoperatively and $20.3^{\circ}$ at last follow up in group 2. Bone union was observed in all cases and 4 cases of screw loosening were noted in Group 1 with extended fracture to anterior process. At the last follow up, both groups showed clinical results in American orthopedic foot and ankle society ankle hindfoot score, 76(77 in Sanders type II and 75 in type III) in group 1 and 72(73 in type II and 70 in type III) in group 2. Conclusion: F plate and locking plate showed firm fixation and satisfactory clinical results in the treatment of intra-articular calcaneal fracture. We suggest applying locking plate in cases with extended fracture to anterior process, considering screw loosenings in those who were treated with F plate fixation.

Simple and Sensitive Electrochemical Sandwich-type Immunosensing of Human Chorionic Gonadotropin based on b-cyclodextrin Functionalized Graphene

  • Linfen Xu;Ling liu;Xiaoyan Zhao;Jinyu Lin;Shaohan Xu;Jinlian He;Debin Jiang;Yong Xia
    • Journal of Electrochemical Science and Technology
    • /
    • 제14권1호
    • /
    • pp.51-58
    • /
    • 2023
  • The effective detection of human chorionic gonadotropin (HCG) is considerably important for the clinical diagnosis of both of early pregnancy and nonpregnancy-related diseases. In this work, a simple and sensitive electrochemical sandwich-type immunosensing platform was designed by synthesizing b-cyclodextrin (CD) functionalized graphene (CD/GN) hybrid as simultaneously sensing platform and signal transducer coupled with rhodamine b (RhB) as probe. In brief, GN offers large surface area and high conductivity, while CD exhibits superior host-guest recognition capability, thus the primary antibody (Ab1) of HCG can be bound into the cavities of CD/GN to form stable Ab1/CD/GN inclusion complex; meanwhile, the secondary antibody (Ab2) and RhB can also enter into the cavities, producing RhB/Ab2/CD/GN complex. Then, by using Ab1/CD/GN as sensing platform and RhB/Ab2/CD/GN as signal transducer (in which RhB was signal probe), a simple sandwich-type immunosensor was constructed. Under the optimum parameters, the designed immunosensor exhibited a considerable low analytical detection of 1.0 pg mL-1 and a wide linearity of 0.002 to 10.0 ng mL-1 for HCG, revealing the developed sandwich-type electrochemical immunosensing platform offered potential real applications for the determination of HCG.

염화아연에 의해 활성화된 폴리아크릴로나이트릴계 다공성 탄소나노섬유의 제조 및 특성 (Preparation and Characterization of Polyacrylonitrile-based Porous Carbon Nanofibers Activated by Zinc Chloride)

  • 이혜민;배경민;강효랑;안계혁;김홍건;김병주
    • 공업화학
    • /
    • 제24권4호
    • /
    • pp.370-374
    • /
    • 2013
  • 본 연구에서는 염화아연의 첨가에 따른 다공성 탄소나노섬유의 제조 시 기공발달에 미치는 영향을 알아보기 위해 10wt%로 제조된 폴리아크릴로나이트릴/디메틸포름아미드 용액을 전기방사 방법을 통해 나노섬유 부직포로 제조하였다. 염화아연에 의해 활성화된 다공성 탄소나노섬유의 표면구조는 주사전자현미경(Scanning Electron Microscope, SEM)을 이용해 관찰하였으며, $N_2/77$ K 등온 흡착특성은 Brunauer-Emmett-Teller (BET)식과 Horvath-Kawazoe (H-K)식을 이용하여 기공특성 분석을 시도하였다. 실험결과 제조된 다공성 탄소나노섬유의 $N_2$ 등온흡착선들은 International Union of Pore and Applied Chemistry (IUPAC)의 분류에서 Type I으로서 주로 미세공들로 이루어져 있음을 알 수 있었다. 염화아연에 의해 활성화된 다공성 탄소나노섬유의 비표면적은 600~980 $m^2/g$으로 분석되었으며, 세공용적은 0.24~0.40 $cm^3/g$로 각각 분석되었다. 또한 주사전자현미경의 분석 결과 활성화로 인하여 표면에 형성되어 있는 많은 세공과 균열이 관찰되었으며, 이러한 결과로부터 염화아연의 첨가가 다공성 탄소나노섬유의 비표면적 증가에 유효한 역할을 하는 것으로 확인되었다.

KSLV발사에 따른 제작 및 제3자피해 책임에 대한 우주법적 소고 (Legal Study for the KSLV launching - Products & Third Party Liability -)

  • 신성환
    • 항공우주정책ㆍ법학회지
    • /
    • 제21권1호
    • /
    • pp.169-189
    • /
    • 2006
  • 2007년 고흥 우주센타에서 우리가 만든 KSLV(Korea Small Launching Vehicle)이 발사될 예정이며, 우리나라의 우주개발을 체계적으로 진흥하고 우주물체를 효율적으로 이용관리하기 위하여'우주개발진흥법'이 제정되었고 효력을 발휘하고 있다. '우주개발진흥법'제3조 (1)항에서"정부는 다른 국가 및 국제기구와 대한민국이 맺은 우주 관련 조약을 지키며 우주공간의 평화적 이용을 도모한다."라고 규정하고 있는바, 대표적으로 우주조약(1967)과 책임협약(1972)등이 그 대표적인 국제협약들이다. 우주물체로 야기된 손해에 대한 책임협약 제2조에서 발사국은 자국의 우주물체에 대하여"지상(on the surface of the earth) 또는 비행중인 항공기(aircraft in flight)에서 발생된 손해에 대하여 절대적(absolutely liable)으로 배상할 책임이 있다고 규정하고 있다. 우주개발진흥법 제14조 (우주사고에 따른 손해배상책임)에는"우주물체를 발사한 자는 그 우주물체로 인한 우주사고에 따른 손해배상책임을 부담하여야 한다."는 규정은 발사허가의 문제를 넘어, 우주발사자에게 명백하게 책임을 부담하고 있는 것이다. 또한 우주책임협약(1972) 제2조에는 발사국(A launching State)이 배상책임의 주체가 되어 있다. 따라서, 현재 다른 나라의 사례에서 보면, 우주발사자는 제3자 피해 등에 대한 책임보험까지만 배상을 하고 그 보다 많은 배상액이 요구될 때에는 국가가 손해배상을 부담하는 체재로 수행하고 있다. 여기서, 우주발사자에게 제조물책임법을 적용시킬 수 있느냐의 문제가 제기된다. 우리나라는 2002년 7월 1일부터 시행하고 있다. KSLV개발에 있어서 KARl와 러시아제작사간 계약은 공동개발인지 기술이전개발 인지에 대한 명확한 이해가 부족하다. 특히, 러시아 회사들에 대한 책임면책에 대한 규정들이 없는 것으로 알고 있는데, 우주개발의 통념상 상호면책을 한다는 인식만으로 러시아 회사들의 제작 및 개발책임들을 면책할 수 있는 방안은 없다고 판단된다. 따라서, 명백한 책임면책 조항이 없다면, 러시아 회사들에 대하여, 한국의 제조물책임법이 적용될 수 있다고 판단된다. 가장 중요한 법적논점은 KARl와 주요부품업체간에 제조물책임법을 적용할 수 있는가에 대한 문제이다. KARl는 모 주요부품업체간의 물품구매계약특수조건에 대한 합의서 제17조에 제조물책임법에 대한 규정을 하고 있다. 참고로, Appalachian Insurance co. v. McDonnell Douglas 사례를 검토할 필요가 있는데, 본 사건은 Western Union Telegraph사 소유의 원거리 전기통신위성이 본 궤도 진입에 실패한 사례이다. Western Union의 보험회사는 완전한 손실로 간주하여 그 위성에 대해 Western Union 사에 1억 5백만 달러의 보험금을 지급하였다. 5개의 보험회사- Appalachian 보험 회사, Commonwealth 보험회사, Industrial Indemnity, Mutual Marine Office, Northbrook Excess & Surplus 보험회사 - 는 McDonnell Douglas와 Morton Thiokol 그리고 Hitco사를 상대로 과실과 제품에 대한 엄격한 책임을 물어 고소를 했다. Appalachian Insurance co. v. McDonnell Douglas사례를 참고로, KARl는 주요 제작업체의 제조물책임을 면책시켜주는 계약을 맺어야 한다. 주요제작업체가 제조물 책임을 면하기 위하여, 자비로 보험을 들게 되면 곧 KSLV 제작비만 증가하게 되기 때문이다. 따라서, Government Contractor Defense(정부계약자 항변)'의 법적개념을 적용시킬 수 있는지 여부에 대한 연구가 필요하다.

  • PDF

외식업 종사자들의 근무 형태에 따른 만족도 연구 (The Study of Satisfactory Degree based on the Working Type in Foodservice Industry)

  • 김기영;김종훈
    • 한국조리학회지
    • /
    • 제8권3호
    • /
    • pp.213-230
    • /
    • 2002
  • The meaning of foodservice industry is various but especially its most important one contains a service industry. And so, foodservice industry should provide very impressive service to customers. if workers don't satisfy themselves at the works, they can not give a high qualifying service to the customers. Therefore, this study showed how the worker's satisfactory degree depending on working type effects on the growth of foodservice industry. The conclusions by questionnaires to workers who have worked as both a regular and a contract employment at Special First Degree Hotels in Seoul are followings. Very interestingly, the proportion of satisfying degree for the workers as regular is 34.94% but the degree for workers as contract is 36.8%. The reason is that the average age of regular workers is high and they have their family to support and they have changed their job more often than the others. They can express their problems through a labor union but the part of solution is very small. It must cause to decrease satisfying degree. The workers generally satisfied to their senior employers. It means that the negative image of higher-ups in the past has been changed. It is a serious problem that the proportion of satisfaction degree remains 30%. The managements must perceive the fact that the increase ratio of contract workers does not make low quality of service. They should know that the satisfaction degree of regular workers is lower than contract ones. In order to increase the satisfaction degree, if the managements can find out the way of taking over their authority and giving a motive, they can reduce the ratio of occupation change and nonattendance. And also they can promote the productivity in foodservice industry and in conclusion, the foodservice industry will have glowed very successfully in the near future.

  • PDF

쇄골 외측단 Rockwood 제2형 골절의 치료 (Treatment for the Rockwood type Ⅱ Fractures of Lateral End of Clavicle)

  • 오창욱;경희수;박건욱
    • Clinics in Shoulder and Elbow
    • /
    • 제1권1호
    • /
    • pp.66-71
    • /
    • 1998
  • The fractures of lateral end of clavicle can be treated by conservative or operative treatment, but many authors report the higher rate of non-union with conservative treatment and that the operative treatment is more effective for the type II fractures. The authors reviewed and analysed 15 cases of lateral end fracture of clavicle which had been treated at Department of Orthopedic Surgery, Kyungpook National University Hospital from 1991 to 1996. The results were as follows; 1. Among the 15 patients, male was 6,female 9 and the average age was 46.2 years ranged from 21 to 72 years. 2. According to the classification by Rockwood, type II a was 8 cases and II b was 7 cases. 3. We treated operatively 12 cases, 9 cases with tension band wiring and 3 cases with intramedul-Iary K-wire fixation. And we treated conservatively 3 cases with Velpeau cast, but I case of nonunion was treated with tension band wiring. 4. The average follow-up was 3.2 years ranged from 2.1 to 4.7 years. 5. The functional results were evaluated with Weitzman's classification. 6. In the operatively treated cases, there were 4 cases(30.7%) in excellent, 7 cases(53.8%) in good and 2 cases(15.3%) in fair result. But, in the conservatively treated cases, there were 2 cases in good and I case in poor result, and the poor case did not united and had open reduction and internal fixation. 7. In conclusion, the operative treatment revealed good functional results in most cases (10/12) and early open reduction and internal fixation was better method than conservative treatment.

  • PDF

Analysis of Radiological and Clinical Results in Treatment of Open Segmented Tibia Fractures: A Comparison between Intramedullary Nailing and Minimal Invasive Plate Osteosynthesis

  • Kim, Ji Wan;Song, Hyung Keun
    • Journal of Trauma and Injury
    • /
    • 제29권3호
    • /
    • pp.76-81
    • /
    • 2016
  • Purpose: The purpose of this study was to compare the data comprehensively including not only the clinical and radiographic outcomes but some parameters related to operation between the minimally invasive plate osteosynthesis (MIPO) technique and intramedullary nailing (IMN) for treatment of segmental tibia shaft fractures. Methods: We conducted a retrospective study of 31 patients (mean age, 49.3 years, range, 27-74 years), with a mean follow-up of 14.1 months (range, 12-19 months) with acute segmental tibial fractures (AO 42-C2) who underwent either surgical treatment of MIPO or IMN. In accordance with the Gustilo-Anderson classification, 11 were type I, 5 were type II, and 15 were type III. Initial compartment syndrome was confirmed in 2 cases. Results: There were no statistically significant differences in terms of the patient demographic data between the two groups. The time to definitive fixation was longer in the MIPO group (mean $13.7{\pm}10.9days$; range, 2-27) than in the intramedullary group (mean $5.4{\pm}9.6days$; range, 0-35) with statistically significant difference (p=0.002). Bony union was observed in most of cases but except 5 cases of nonunion were diagnosed (3 in the MIPO vs 2 in IMN, p=0.188). The average bone healing time was 27.1 weeks (10 to 56 weeks) in MIPO group and 23.2 weeks (13 to 66 weeks) in IMN group, respectively (p=0.056). Overall complications were 5 cases in MIPO group and 2 cases in the IMN group. Difference in LEFS was not statistically significant between both groups (p=0.824). Conclusion: This study showed that segmental tibia shaft fractures treated with both MIPO and intramadullary nailing was challenging with relatively high complication rate. A well planned sequential strategy with keeping the soft tissue and personality of fracture in mind is utmost significant as much as the choice of surgical modalities.

Comparison of Test Standards for the Performance and Safety of Agricultural Tractors: A Review

  • Kabir, Md. Shaha Nur;Chung, Sun-Ok;Kim, Yong-Joo;Shin, Sung-Hyun
    • Journal of Biosystems Engineering
    • /
    • 제39권3호
    • /
    • pp.158-165
    • /
    • 2014
  • Purpose: The objective of this paper was to compare test standards regarding the performance and safety of agricultural tractors to identify the differences in test conditions, measurement tolerances, and test procedures. Based on the comparison, some recommendations were proposed for possible revisions or improvements to current tractor test standards. Methods: The test standards and codes of major standards development organizations (SDOs), such as the Organization for Economic Cooperation and Development (OECD), the International Organization for Standardization (ISO), the American Society of Agricultural and Biological Engineers (ASABE), EC type approval, and the board of actions of the Nebraska Tractor Test Laboratories (NTTL), were selected and analyzed. Comparison of the test standards: The ISO provides references for fuel and lubricants for tractor tests, and the OECD provides additional measurements for calculating fuel consumption characteristics during the power take-off (PTO) tests. The ISO, EC type approval, and the ASABE provide PTO protective device and the safety requirements. During drawbar power tests, seven transmission ratios are selected for fully automatic transmissions, according to the OECD. In case of hydraulic lift tests, ISO 789-2 and OECD Code 2 advise the use of a static lift force, while SAE J283 advises the use of additional dynamic lift capacity tests for a better representation of in-field operations. The OECD, the ISO, and EC type approval determine the seat index point (SIP), whereas the ASABE determines the seat reference point (SRP) for roll-over protective structure (ROPS) tests. Diversified measurement tolerances were among the braking performance test standards. The European Union (EU) has developed daily limits for vibration exposures with adaptations from ISO 2631-1. Electromagnetic compatibility evaluations are emerging of high-efficiency tractors due to the long-term conformance to electromagnetic emissions and interferences. Comparisons of tractor test standards discussed in this paper are expected to provide useful information for tractor manufacturers and standards development personnel to improve the performance and safety test standards of tractors.