New Acoustic Imaging Method Development for Localization of an Underground Acoustic Source Using a Passive SONAR System

  • Jarng, Soon-Suck
    • The Journal of the Acoustical Society of Korea
    • /
    • v.18 no.2E
    • /
    • pp.10-17
    • /
    • 1999
  • The aim of the work described in this paper is to develop a complex underground acoustic system which detects and localizes the origin of an underground hammering sound using an array of hydrophones located about 100m underground. Three different methods for the sound localization will be presented, a time-delay method, a power-attenuation method and a hybrid method. In the time-delay method, the cross correlation of the signals received from the array of sensors is used to calculate the time delays between those signals. In the power-attenuation method, the powers of the received signals provide a measure of the distances of the source from the sensors. In the hybrid method, both informations of time-delays and power-ratios are coupled together to produce better performance of position estimation. A new acoustic imaging technique has been developed for improving the hybrid method. This new acoustic imaging method shows the multi-dimensional distribution of the normalized cost function, so as to indicate the trend of the minimizing direction toward the source location. For each method the sound localization is carried out in three dimensions underground. The distance between the true and estimated origins of the source is 28m for a search area of radius 250m.

  • PDF

A Study on the Calculation of Transmission Current-Carrying Capacity by Horizontal Arrangement Type in the Installation Methods of 154kV XLPE 600㎟ Power Cable Buried Ducts in Ground (154kV XLPE 600㎟ 지중관로 수평배열 형태별 허용전류용량 산정에 관한 연구)

  • Kim, Se-Dong;Yoo, Sang-Bong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.30 no.3
    • /
    • pp.53-58
    • /
    • 2016
  • The underground transmission lines which have been built to expand the suppling facilities will be continuously accompanying with high growth of the increase of power demand in the metropolitan area in recent years. So, it is necessary to maximize the ability and reliability of power supply with the current-carrying capability of the underground transmission lines. Design criteria of KEPCO is to be presented and used frequently. But it has to be studied about the installation methods of power cable buried in ground. In this study, we used the program for calculating the current-carrying capability of underground transmission power cables. We estimated the maximum permissible current values by the horizontal arrangement in the installation methods of power cable(154kV XLPE $600mm^2$) buried ducts in ground. To see the general tendency of the analysis, we researched a statistical analysis with such parameters as the maximum permissible current values. Through the regression analysis, we analyze the most highly values of the maximum permissible current on the Ra type duct arrangement.

Crime Prevention Through Environmental Design of Underground Parking in Commercial Facilities - Field survey of Underground Parking Spaces in Department stores, Large Discount Mart and Mixed Used Commercial Facilities - (상업시설 지하주차장의 CPTED계획요소에 관한 연구 - 대형마트와 백화점, 복합상업시설 지하주차장 현장조사 -)

  • Min, Young Hee;Kwon, Ju-Young;Ha, Mi-Kyoung
    • Korean Institute of Interior Design Journal
    • /
    • v.25 no.3
    • /
    • pp.129-137
    • /
    • 2016
  • Dark and desolate underground parking spaces in commercial facilities are optimal spaces for crime. First, this study reviewed 15 precedent CPTED guidelines and related literatures, and as a result extracted 45 CPTED planning criteria for underground parking facilities. Secondly by field survey, we investigated six parking spaces in commercial facilities whether they were planned properly based on 45 checklist items, in six categories of CPTED principles. In result, target facilities showed average 46.8% relevance ratio, which means less than a half of 45 items of CPTED planning factors were not applied. Guidelines suggest desirable illuminance level of more than 100 lux, however the measurement of illuminance levels in some parking spaces showed below 50 lux. Relatively department stores were keeping CPTED guidelines better than large discount mart and mixed used facilities. Definition of territory of loading dock and customer area should be clarified, clear signage and color scheme in different zones should be represented with higher level of territorial responsibilities and surveillance in mixed used facilities for further improvement.

A Study on Air Pollution and Thermal Factors in Underground Shopping Center of Pusan Area (부산시내 지하생활권의 공기오염도와 온열인자에 관한 조사연구)

  • Choi, Sung-Yong;Moon, Deog-Hwan;Lee, Jong-Tae;Song, In-Hyuk;Lee, Cha-Eun;Lee, Sung-Min
    • Journal of Preventive Medicine and Public Health
    • /
    • v.27 no.3 s.47
    • /
    • pp.505-516
    • /
    • 1994
  • For the purpose of preparing the fundamental data on air pollution in underground shopping center and also contributing to the health improvement of residents, the authors measured the level of $SO_2,\;NO_2,\;TSP,\;CO,\;CO_2$ and also some related factors as air temperature, air movement, relative humidity and mean radiation temperature at inside and outside of underground shopping center in Pusan from January to February and from July to August 1994. The results were as follows : 1. The mean concentration of CO within the underground shopping center was $3.1{\pm}1.3ppm$ in winter and $2.1{\pm}0.9ppm$ in summer. There was a negative correlation (p<0.01) between inner CO concentration and temperature in summer and no correlation between inner CO concentration and outer CO concentration in underground shopping center 2. The mean concentration of COE within the underground shopping center was $876{\pm}353ppm$ in winter and $757{\pm}125ppm$ in summer. There was a negative correlation (p<0.01) between inner $CO_2$ concentration and air movement in summer and positive correlation (p<0.05) between inner $CO_2$ concentration and outer $CO_2$ concentration in underground shopping center. 3. The mean concentration of $SO_2$ within a underground shopping center was $0.036{\pm}0.019ppm$ in winter and $0.040{\pm}0.013ppm$ in summer. There was a positive correlation(p<0.01) between inner $SO_2$ concentration and temperature in summer and positive correlation between inner $SO_2$ concentration and outer $SO_2$ concentration in summer and winter in underground shopping center. 4. The mean concentration of $NO_2$ within a underground shopping center was $0.052{\pm}0.038ppm$ in winter and $0.042{\pm}0.016ppm$ in summer. There was a no correlation between inner $SO_2$ concentration and thermal factors in summer and winter and low correlation between inner $SO_2$ concentration and outer $SO_2$ concentration in underground shopping center 5. The mean concentration of TSP within a underground shopping center was $430{\pm}214{\mu}g/m^3$ in winter, $366{\pm}73{\mu}g/m^3$ in summer, and very in excess of the atmospheric environmental quality standards of Korea ($150{\mu}g/m3{\downarrow}$). There was low correlation between inner TSP concentration and temperature in summer and high correlation between inner TSP concentration and outer TSP concentration in underground shopping center.

  • PDF

The Design of Underground Utilities Management System based on Mobile Augmented Reality Technology (모바일 증강현실 기술을 이용한 지하 사회 기반 시설 관리 시스템 설계)

  • Baek, Jang-Mi;Hong, In-Sik
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.13 no.1
    • /
    • pp.41-47
    • /
    • 2013
  • A great number of people all over the world are using smart phones. Researchers develop innovative technology of App. It's make rapid progress now that the country's infrastructure is computerized, we expect IT Technological Convergence. In this paper, designs underground utilities management system based on mobile augmented reality technology, and architecture configuration, interface development. Proposal system minimizes overhead of smart devices belonging to engineer's representative using wireless personal area networks. Center Server technology manages transmitted data from engineer's representative, it monitors client data path. And it provies information processing capacity for event generation module. Such event has connotations of instability and uncertainty.

Respirable Cool Dust Exposure Concentration at Work Sites of Underground Coal Mines in Taebaek Area (태백지역 석탄광산의 작업부서별 호흡성 분진 폭로농도)

  • Yoon, Young No;Chung, Ho Keun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.1 no.1
    • /
    • pp.47-55
    • /
    • 1991
  • Exposure level of respirable coal dust of underground coal mines in Taebaek area was evaluated. Personal air samplers with 10-mm nylone cyclones were attached to the coal workers including drillers, coal cutters, their assistants, haulers, and separators. Log-normality of respirable dust exposure concentration were tested by Kolmogorov-Smirnov one-sample test. Differences of means of respirable dust exposure concentration between work sites were tested by one-way ANOVA test and multiple comparison(Scheffe) test. And differences of respirable dust exposure concentration of principal and assistant workers in drilling sites and in coal faces were tested by paired t-test. Relation of respirable dust exposure concentration for the principal workers and their assistants in drilling sites and in coal faces were tested by regression analysis. The results were as follows : 1. All of the respirable dust concentration were log-normally distributed. 2. There were not only significantly different means of exposure concentration between drillers and coal cutters but between coal cutters and haulers. 3. Means of exposure concentration of drillers and drilling assistants were not significantly different. And means of exposure concentration of coal cutters and coal cutting assistants were not different.

  • PDF

Detection of Limesilicate Cavities by 3-D Resistivity Survey (3차원 전기비저항탐사에 의한 석회암 공동탐지)

  • Park, Sam-Gyu;Yi, Myeong-Jong;Kim, Chang-Ryol;Son, Jeong-Sul;Kim, Jung-Ho;Cho, Seong-Jun;Seo, Goo-Won
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.147-152
    • /
    • 2006
  • In this study, we examined the applicability of three-dimensional electrical resistivity survey to detect underground cavities of ground subsidence area at the field test site, located at Yongweol-ri, Muan-gun in Korea. Underground cavities are widely present within the limesilicate bedrock overlain by the alluvial deposits in the area of the test site where the ground subsidences have occurred in the past. The limesilicate cavities are mostly filled with groundwater and clays in the test site. Thus, cavities have low electrical resistivity compared to the surrounding host bedrock. The results of the study have shown that the zones of low resistivity correspond to the zones of the cavities identified in the boreholes at the site, and that the three-dimensional electrical resistivity survey used are very effective to detect underground cavities.

  • PDF

A Study on the Distribution Stresses beneath Loaded Ground Surface Area of Double Strata Ground on Soft Clay Layers (연약점토층위 이층지반 지표면 재하시 지중응력 특성연구)

  • Lee, In-Hyung;Lim, Jong-Seok
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.47 no.6
    • /
    • pp.47-57
    • /
    • 2005
  • Stress distribution in soils is the very important element to design and to solve the problems of settlement, safety of foundations and trafficability of constructing vehicle in civil engineering. This research presents the comparative estimation of the actual and theoretical measurement on the underground stress of outer layer for each soil after the observation of each top soil layer fur its vertical and horizontal stresses in (1) homogeneous sand ground (2) weak stratum with the sand soil (3) weak stratum with gravel of the soil model, and it also investigates the effect of subsidence of ground by the repeated load. The underground stresses fumed out to be different in the value of theoretical and actual measurement after the trial examination of model. This study has the purpose of suggesting the better construction method of running equipment on weak stratum by comparing the estimated value of trial experiment and theory on underground stress of the weak ground surface area and of raising up the necessity of the continuous research hereafter.

It is development about search and shopping of underground center for O2O-based marketing (O2O 기반의 마케팅을 위한 지하상가 검색 및 쇼핑 앱 개발)

  • Lee, Hye-bin;Kim, Jun-hwan;Ku, Ye-sol;Lee, Gyeong-yong;Jung, Deok-gil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.304-307
    • /
    • 2015
  • It's a shame one of the famous places of Busan is the underground shopping area on the decline gradually. The reason why we developed this application is to provide information of the desired product and store for other residents as well as Busan residents. As a result, we expect a revival of underground shopping area. The main features of the application are to provide the location of shops and the information of products. In addition, it provides information of shops around me to utilize of location-based-service. We studied the possibility of win-win situation between offline stores and online through this application.

  • PDF

A Study on the Thermal Analysis of Indirect Water Cooled Power Cables Laid within Trough devided into Several Sub-Sections (다수의 부구간으로 나누어지는 트로프간 접수냉 전력케이불의 열해석에 관한 연구)

  • Moon, Young-Hyun;Kim, Baik;Lee, Tae-Shik
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.41 no.7
    • /
    • pp.703-711
    • /
    • 1992
  • As the underground area of the metropolitan becomes denser recently, an introduction of forced cooling system is under study to maximize the carrying capacity of existing cables in tunnels. Indirect water cooling system laid within trough will probably be adopted for the next 345KV class underground power cables in this country. The system covers a distance of 1.5-3.0Km for one water cooling interval and one water cooling interval is composed of several sub-sections that have different thermal analysis conditions. Thus the distribution of temperature in each sub-section is described by different conditions in general. In this paper a method that can accurately match the temperature of the coolant in the boundary between sub-sections has been suggested. An algorithm to find the temperature distributions effectively in the thermal system has also been presented. A computer program using this method has been tested in a smaple system and the results have shown the usefulness of this program.

  • PDF