A Study on Air Pollution and Thermal Factors in Underground Shopping Center of Pusan Area

부산시내 지하생활권의 공기오염도와 온열인자에 관한 조사연구

  • Choi, Sung-Yong (Department of Preventive Medicine College of Medicine, and Institute of Industrial Medicine, Inje University) ;
  • Moon, Deog-Hwan (Department of Preventive Medicine College of Medicine, and Institute of Industrial Medicine, Inje University) ;
  • Lee, Jong-Tae (Department of Preventive Medicine College of Medicine, and Institute of Industrial Medicine, Inje University) ;
  • Song, In-Hyuk (Department of Preventive Medicine College of Medicine, and Institute of Industrial Medicine, Inje University) ;
  • Lee, Cha-Eun (Department of Preventive Medicine College of Medicine, and Institute of Industrial Medicine, Inje University) ;
  • Lee, Sung-Min (Graduate School of Public Health, Inje University)
  • 최성용 (인제대학교 의과대학 예방의학교실 및 산업의학연구소) ;
  • 문덕환 (인제대학교 의과대학 예방의학교실 및 산업의학연구소) ;
  • 이종태 (인제대학교 의과대학 예방의학교실 및 산업의학연구소) ;
  • 송인혁 (인제대학교 의과대학 예방의학교실 및 산업의학연구소) ;
  • 이채언 (인제대학교 의과대학 예방의학교실 및 산업의학연구소) ;
  • 이승민 (인제대학교 보건대학원)
  • Published : 1994.09.01

Abstract

For the purpose of preparing the fundamental data on air pollution in underground shopping center and also contributing to the health improvement of residents, the authors measured the level of $SO_2,\;NO_2,\;TSP,\;CO,\;CO_2$ and also some related factors as air temperature, air movement, relative humidity and mean radiation temperature at inside and outside of underground shopping center in Pusan from January to February and from July to August 1994. The results were as follows : 1. The mean concentration of CO within the underground shopping center was $3.1{\pm}1.3ppm$ in winter and $2.1{\pm}0.9ppm$ in summer. There was a negative correlation (p<0.01) between inner CO concentration and temperature in summer and no correlation between inner CO concentration and outer CO concentration in underground shopping center 2. The mean concentration of COE within the underground shopping center was $876{\pm}353ppm$ in winter and $757{\pm}125ppm$ in summer. There was a negative correlation (p<0.01) between inner $CO_2$ concentration and air movement in summer and positive correlation (p<0.05) between inner $CO_2$ concentration and outer $CO_2$ concentration in underground shopping center. 3. The mean concentration of $SO_2$ within a underground shopping center was $0.036{\pm}0.019ppm$ in winter and $0.040{\pm}0.013ppm$ in summer. There was a positive correlation(p<0.01) between inner $SO_2$ concentration and temperature in summer and positive correlation between inner $SO_2$ concentration and outer $SO_2$ concentration in summer and winter in underground shopping center. 4. The mean concentration of $NO_2$ within a underground shopping center was $0.052{\pm}0.038ppm$ in winter and $0.042{\pm}0.016ppm$ in summer. There was a no correlation between inner $SO_2$ concentration and thermal factors in summer and winter and low correlation between inner $SO_2$ concentration and outer $SO_2$ concentration in underground shopping center 5. The mean concentration of TSP within a underground shopping center was $430{\pm}214{\mu}g/m^3$ in winter, $366{\pm}73{\mu}g/m^3$ in summer, and very in excess of the atmospheric environmental quality standards of Korea ($150{\mu}g/m3{\downarrow}$). There was low correlation between inner TSP concentration and temperature in summer and high correlation between inner TSP concentration and outer TSP concentration in underground shopping center.

Keywords