• Title/Summary/Keyword: Under the microscope

Search Result 1,668, Processing Time 0.03 seconds

Axillary Approach for Thyroidectomy under Operating Microscope (수술현미경하 액와접근 갑상선 절제술)

  • Choi, Jong-Ouck;Jun, Byung-Sun;Lee, Jang-Woo;Lee, Dong-Jin;Sohn, Hang-Soo
    • Korean Journal of Head & Neck Oncology
    • /
    • v.23 no.1
    • /
    • pp.32-36
    • /
    • 2007
  • Background and Objective:A post-operative hypertrophic scar of the anterior neck is the leading complaint of the patients who underwent conventional thyroid surgery. In order to minimize the post-operative scar of the anterior neck, we performed thyroidectomy via axillary approach using operating microscope and a specialized retractor to determine technical feasibility. Patients and Methods:From January 2005 to December 2006, we performed thyroidectomy via axillary approach under operating microscope(f=400mm, ${\times}2.5$;OPMI $pico^{(R)}$;Zeiss, Germany) for benign unilateral nodule in 25 cases(all female, average age 34.5yrs). Under general anesthesia less than 7cm of skin incision was made in the axilla of ipsilateral side. A subcutaneous tunnel went over the pectoralis major muscle and the clavicle, and then through the sternocleidomastoid muscle and sternothyroid muscle was excised. The area around the thyroid was sufficiently dissected, and then a retractor designed for exposure via axillary approach was placed within the tunnel and under operating microscope thyroidectomy was performed. Results:There were 17 cases of thyroid nodulectomy and 8 cases of subtotal lobectomy. The mean average operative time was 102.64minutes. Postoperative complications included one case of postoperative bleeding, one case of temporary vocal cord paralysis, two cases of delayed wound healing, two cases of paresthesia of shoulder and arm, and two cases of hypertrophic scar of the axilla. Postoperative histopathology includes 17 cases of adenomatous hyperplasia, six cases of cyst, and two cases of follicular adenoma. For all cases hospitalization period was two days. Conclusion:Thyroidectomy via axillary approach under operating microscope has a good cosmetic advantage without a post-operative scar of the anterior neck. The procedure is simple due to direct vision using operating microscope, easy to identify important structures by magnifying them, and therefore surgical time can be reduced.

Microscope Examination of Attached Biofilm under Anaerobic Conditions (혐기성 조건에서 담체에 부착된 미생물의 관찰)

  • 박성열;김도한;나영수;박영식;송승구
    • Journal of Environmental Health Sciences
    • /
    • v.27 no.1
    • /
    • pp.100-105
    • /
    • 2001
  • Microstructural examinations were performed on the anaerobic biofilm from reactor filled with PE support media. Optical microscope, SEM and fluorescent microscope were used for qualitative and morphological studies on the attached microorganism under anaerobic condition. Microorganisms were attached in crevices where protection from shear forces of surfaces where easy to contact with support media surface. A hypothesis for biofilm accumulation occurs on a surface such as polymer support media is presented schematically : 1st step ; cell-support media attachment, 2nd step ; cell-support media attachment and cell-cell attachment, 3rd step ; attached biofilm from neighboring crevices joins together and growing, 4th step ; mature and irregualar biofilm was formed. In SEM photographs, shape and structures of biofilm were observed, but microorganism species and methanogens were not identified. A large number of methanogenic bacteria were identified on the surface of PE substratum by fluorescence under 480nm of radiation and it was estimated that methanogenic bacteria was related to initial attachment of bacteria under anaerobic condition.

  • PDF

Congenital Constriction Band Syndrome of Hand ; The Correction Under The Microscope (선천성 수부 윤상 수축대 증후군에 대한 미세현미경을 이용한 수술적 교정)

  • Hwang, Ho;Kim, Yong-Kyu;Whang, Jong-Ick
    • Archives of Reconstructive Microsurgery
    • /
    • v.14 no.1
    • /
    • pp.70-76
    • /
    • 2005
  • The Z-plasty has been known as a most common surgical treatment of congenital circumferential constriction band syndrome of the hand. There were thirteen patients of congenital circumferential constriction band syndrome of the hand. All patients underwent Z-plasty under microscope. we did microsurgical dissection to minimize vascular, neural and lymphatic injury, and then considering secondary correction and scar contracture, tried to preserve as much subcutaneous fat and skin flap as possible without any excision. There were less skin necrosis and lymphedema as a result of vascular compromise. Using microscope offers several advantages. First, preventing vascular, neural and lymphatic injury. Second, getting an accurate suture approximation. finally, preserving as much subcutaneous fat and skin flap as possible without any excision. The outcome of digit growth and contour can be excellent than we expected. As a results, we believe that correction of congenital circumferential constriction band syndrome of the hand under the microscope have better results.

  • PDF

Shear Induced Homogenization Study of an Immiscible Polymer Blend Solution Using Fluorescence Microscope (형광 현미경을 이용한 비상용 고분자 블렌드 용액의 전단 균질화 연구)

  • 유재웅
    • Polymer(Korea)
    • /
    • v.27 no.5
    • /
    • pp.413-420
    • /
    • 2003
  • Fluorescence microscope technique was employed for the characterization of phase separation behavior of a 4-chloro-7-nitrobenzofurazan labeled polystyrene (PS) / polybutadiene (PB) blend in dioctyl phthalate under steady shear. It was confirmed that the fluorescence microscope images reflect the real phase morphology by comparing with the images of phase contrast microscope. Comparing the fluorescence intensities from the phase separated domain (PS rich) and continuous phase (PB rich), the composition difference between these two phases were deduced. The observed shear dependence of compositional change is then used to confirm that the phase diagram is indeed shifted under the steady shear.

Characteristics of attach of biomass on PE substratum under anaerobic condition (폴리에틸렌 담체에 부착된 혐기성 생물막 부착 특성)

  • 이승란;김도한;나영수;이창한;박영식;윤태경;송승구
    • Journal of Environmental Science International
    • /
    • v.11 no.4
    • /
    • pp.327-332
    • /
    • 2002
  • Optical microscope, SEM (Scanning Electron Microscopy) and fluorescent microscope were used for qualitative and morphological studies of the attached biomass on PE (polyethylene) substratum under anaerobic condition. It was shown by the observation of optical microscope that the initial attachment of biomass began in crevices of the surface of PE. The shape and structure of the attached biofilm could be observed by SEM photographs, but species of bacteria were and methanogens were not classified. A large number of methanogenic bacteria were identified on the surface of PE substratum by fluorescence under 480nm of radiation. It was estimated that methanogenic bacteria was also related to initial attachment of biomass under anaerobic condition.

AN ELECTRON MICROSCOPIC STUDY OF THE IRRADIATION EFFECTS ON THE RAT PAROTID INTERCALATED DUCT CELLS (방사선조사가 타액선 도관세포에 미치는 영향에 관한 전자현미경적 연구)

  • Choi Won Jai;Lee Sang Rae
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.18 no.1
    • /
    • pp.137-147
    • /
    • 1988
  • This study was designed to investigate the effects of irradiation on the salivary ductal cells, especially on the intercalated ductal cells of the rat parotid glands. For this study, 36 Sprague-Dawley strain rats were irradiated on the head and neck region with absorbed dose of 15Gy by Co-60 teletherapy unit, Picker's model 4M60. The conditions irradiated were that field size, SSD, dose rate and depth were 12×5㎝m, 50㎝, 222 Gy/min. and 1㎝. respectively. The experimental animals were sacrificed 1, 2, 3, 6, 12 hours and 1, 3, 7 days after the irradiation and the changes of the irradiated intercalated duct cells of the parotid glands were examined under the light and electron microscope. The results were as follows: 1. Under the light and electron microscope, the nucleus, mitochondria and secretory granules showed severe changes in the early stage after irradiation and the most severe cellular de- generations were observed 2 hours after irradiation, but the repair processes began from 6 hours after irradiation. 2. Under the electron microscope, loss of the nuclear membranes, derrangement of the chromosomes, swelling and destruction of the secretory granules, and widening of the intercellular spaces were observed after irradiation. 3. Under the light microscope, atrophy and irregular proliferation of the ductal cells, cuboidal metaplasia, hyperchromatism, and the construction or obstruction of the lumen were observed after irradiation.

  • PDF

Comparison of Gold Biosensor Combined with Light Microscope Imaging System with ELISA for Detecting Salmonella in Chicken after Exposure to Simulated Chilling Condition

  • Mi-Kyung Park
    • Journal of Microbiology and Biotechnology
    • /
    • v.33 no.2
    • /
    • pp.228-234
    • /
    • 2023
  • In this study, the performance of a gold biosensor combined with light microscope imaging system (GB-LMIS) was comparatively evaluated against enzyme-linked immunosorbent assay (ELISA) for detecting Salmonella under simulated chilling condition. The optimum concentration of antiSalmonella polyclonal antibodies (pAbs) was determined to be 12.5 and 100 ㎍/ml for ELISA and GBLMIS, respectively. GB-LMIS exhibited a sufficient and competitive specificity toward three tested Salmonella among only. To mimic a real-world situation, chicken was inoculated with Salmonella cocktail and stored under chilling condition for 48 h. The overall growth of Salmonella under chilling condition was significantly lower than that under non-exposure to the chilling condition (p < 0.05). No significant differences in bacterial growth were observed between brain heart infusion and brilliant green broth during the enrichment period (p > 0.05). Finally, both GB-LMIS and ELISA were employed to detect Salmonella at every 2-h interval. GB-LMIS detected Salmonella with a competitive specificity by the direct observation of bacteria on the sensor using a charge-coupled device camera within a detection time of ~2.5 h. GB-LMIS is a feasible, novel, and rapid method for detecting Salmonella in poultry facilities.

Challenges in the development of the ultrafast electron microscope (초고속 전자 현미경의 개발과 극복 과제)

  • Park, Doo Jae
    • Vacuum Magazine
    • /
    • v.2 no.1
    • /
    • pp.17-20
    • /
    • 2015
  • In this article, a historical and scientific review on the development of an ultrafast electron microscope is supplied, and the challenges in further improvement of time resolution under sub-picosecond or even sub-femtosecond scale is reviewed. By combining conventional scanning electron microscope and femtosecond laser technique, an ultrafast electron microscope was invented. To overcome its temporal resolution limit which originates from chromatic aberration and Coulomb repulsion between individual electrons, a generation of electron pulse via strong-field photoemission has been investigated thoroughly. Recent studies reveal that the field enhancement and field accumulation associated with the near-field formation at sharply etched metal nanoprobe enabled such field emission by ordinary femtosecond laser irradiation. Moreover, a considerable acceleration reaching 20 eV with near-infrared laser and up to 300 eV acceleration with mid-infrared laser was observed, and the possibility to control the amount of acceleration by varying the incident laser pulse intensity and wavelength. Such findings are noteworthy because of the possibility of realizing a sub-femtosecond, few nanometer imaging of nanostructured sample.in silicon as thermoelectric materials.

A STUDY ON SURFACE ROUGHNESS OF COMPOSITE RESINS AFTER FINISHING AND POLISHING -an Atomic Force Microscope study (연마방법에 따른 복합레진의 활택도에 관한 연군 -Atomic Force Microscope를 이용한 연구)

  • Kim, Hyeong-Seob;Woo, Yi-Hyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.35 no.4
    • /
    • pp.719-741
    • /
    • 1997
  • This study was undertaken to compare by Atomic Force Microscope the effects of various finishing and polishing instruments on surface roughness of filling and veneering composite resins. Seven composite resins were studied : Silux Plus (3M Dental Products, U.S.A.), Charisma (Heraeus Kulzer, Germany), Prisma THP (L.D.Caulk, Dentsply, U.S.A.), Photoclearfil (Kuraray, Japan), Cesead (Kuraray, Japan), Thermoresin LC (GC, Japan), Artglass (Heraeus Kulzer, Germany). Samples were placed and polymerized in holes (2mm thick and 8.5mm in diameter) machined in Teflon mold under glass plate, ensuring excess of material and moulded to shape with polyester matrix strip. Except control group (Polyester matrix strip), all experimental groups were finished and polishied under manufacturer's instructions. The finishing and polishing procedure were : carbide bur (E.T carbide set 4159, Komet, Germany), diamond bur (composite resin polishing bur set, GC, Japan), aluminum-oxide disc (Sof-Lex Pop-On, 3M Dental Products, U.S.A.), diamond-particle disc (Dia-Finish, Renfert Germany), white stone bur & rubber point( composite finishing kit, EDENTA, Swiss), respectively. Each specimens were evaluated for the surface roughness with Atomic Force Microscope (AutoProbe CP, Park Scientific Instruments, U.S.A.) under contact mode and constant height mode. The results as follows : 1. Except Thermoresin LC, all experimental composite resin groups showed more rougher than control group after finishing and polishing(p<0.1). 2. A surface as smooth as control group was obtained by $Al_{2}O_{3}$ disc all filling composite resin groups except Charisma and all veneering composite resin groups except Thermoresin LC(p<0.05). 3. In case of Thermoresin LC, there were no statistically significant differences before and after finishing and polishing(p>0.1). 4. Carbide bur, diamond bur showed rough surfaces in all composite resin groups, so these were inappropriate for the final polishing instruments.

  • PDF

고분자 담체에 부착된 미생물 형상

  • Park, Seong-Yeol;Lee, Seung-Ran;Park, Yeong-Sik;Song, Seung-Gu
    • 한국생물공학회:학술대회논문집
    • /
    • 2000.11a
    • /
    • pp.532-535
    • /
    • 2000
  • Optical microscope, SEM and fluorescent microscope were used for qualitative and morphological studies of the attachment bacteria on PE substratum under anaerobic condition. The observation of optical microscopic has demonstrated that the initial attachment of bacteria began in crevices of surface. In SEM photographs, shape and structure of biofilm could be observed, but bacteria species and methanogens was not identified. A large number of methanogenic bacteria were showed on the surface of PE substratum by fluorescence under 480nm of radiation. It was estimated that methanogenic bacteria was related to initial attachment of bacteria under anaerobic condition.

  • PDF