• 제목/요약/키워드: Uncertainty measurement

검색결과 930건 처리시간 0.033초

Study on Validity and Reliablity of the Cutoff Probe and Langmuir Probe via Comparative Experiment in the Processing Plasma

  • Kim, D.W.;You, S.J.;You, K.H.;Lee, J.W.;Kim, J.H.;Chang, H.Y.;Oh, W.Y.
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제44회 동계 정기학술대회 초록집
    • /
    • pp.576-576
    • /
    • 2013
  • Recently, diagnostics of plasma becomes more important due to requirement of precise control of plasma processing based on measurement of plasma characteristics. The Langmuir probe has been used for the diagnostics but it has an inevitable uncertainty and error sources such as incorrect tip length and RF noise. Instead of the Langmuir probe, various diagnostic methods have been developed and researched. The cutoff probe is promising one for plasma density using microwaves and resonance phenomenon at the plasma frequency. The cutoff probe has various advantages as follows; (i) it is simple and robust, (ii) it uses few assumptions, and (iii) it is free from deposition by reactive gas. However, the cutoff probe also has uncertainty and error sources such as gap between tips, tip length, direction of tip plane, and RF noise. In this study, the uncertainty and error sources in manufacturing both probes and in diagnostics process were analyzed via comparative experiment at various discharge conditions. Furthermore, to reveal the user dependence of both probes, three well trained Ph. D students made the Langmuir probe and the cutoff probe, respectively, and it were analyzed. Thought this study, it is established that reliability and validity of the Langmuir probe and the cutoff probe related with not only the intrinsic characteristics of probes but also probe user.

  • PDF

자외선 영역의 에어로졸 광학 깊이의 계절 분포 및 불확실도의 계산 (Seasonal Variation and Measurement Uncertainty of UV Aerosol Optical Depth Measured at Gwangju, Korea)

  • 김정은;김영준
    • 한국대기환경학회지
    • /
    • 제21권6호
    • /
    • pp.631-637
    • /
    • 2005
  • A UV-MFRSR instrument was used to measure the global and diffuse irradiances in 7 narrowband channels in the UV range 299.4, 304.4, 310.9, 317.3. 324.5, 331.3 and 367.4 nm at Gwangju ($35^{circ}\;13'N\;126^{circ}\;50'E$), Korea. Spectral UV-AOD was retrieved using the Langley plot method for data collected from April 2002 to July 2004. Temporal variation of AOD at 367.4 nm ($AOD_{367nm}$) showed a maximum in June ($0.95\pm0.43$) and a minimum in February ($0.31\pm0.14$). Clear seasonal variation of $AOD_{367nm}$ was observed with average values of $0.68\pm0.29,\;0.82\pm0.41,\;0.48\pm0.22\;and\;0.42\pm0.21$ in spring, summer, fall and winter, respectively, Average Angstrom exponent for the entire monitoring period was $2.03\pm0.75$ in the UV-A ($324.5\∼367.4$ nm) range. Seasonal variation of the Angstrom exponent showed a maximum in spring and a minimum in summer. The lowest Angstrom exponent in summer might be due to hygroscopic growth of particles under conditions of high relative humidity. UV-AOD changes under different atmospheric conditions were also analyzed. Uncertainty in retrieving spectral UV-AOD was also estimated to range between $\pm0.218\;at\;304.4\;nm\;and\;\pm0.135\;at\;367.4\;nm$. Major causes of uncertainty were total column ozone retrieval and extraterrestrial irradiance retrieval at shorter and longer wavelengths, respectively.

일강우 내삽을 이용한 일유량 시뮬레이션 및 앙상블 유량 발생 (Ensemble Daily Streamflow Forecast Using Two-step Daily Precipitation Interpolation)

  • 황연상;허준행;정영훈
    • 한국수자원학회논문집
    • /
    • 제44권3호
    • /
    • pp.209-220
    • /
    • 2011
  • 입력자료의 불확실성은 강우-유출 모의에서 중요한 불확실성 요소 중의 하나이다. 본 연구에서는 먼저 세 가지의 서로 다른 내삽 기법을 통해 계산된 강수 입력 자료 (관측값을 각 소유역의 중심점으로 내삽하여 추정한 입력자료임)들이 강우-유출 모형에 미치는 영향을 분포형 수문모형 (PRMS)을 이용하여 분석하였으며, 내삽오차를 바탕으로 발생한 입력자료를 앙상블 유량 예측에 이용하는 과정을 수문학적으로 서로 다른 두개 하천 유역에 적용하였다. 또한 Monte Carlo기법을 이용하여 수문 모형의 매개변수가 서로 다른 입력자료의 특성에 따라 변화하는 양상을 구분하여 보았다. 본 연구에서 제시된 앙상블 유량 예측방법은 기상 예측 및 기상 모형의 결과물 등의 입력자료를 이용함으로써 중/장기 유량 예측에 활용될 수 있을 것으로 판단된다.

직류-교류 자기장 표준 시스템 제작 및 국제비교 결과 (Construction of AC-DC Magnetic Field Standard Systems and Results of International Key Comparison)

  • 박포규;김영균
    • 한국자기학회지
    • /
    • 제14권6호
    • /
    • pp.201-206
    • /
    • 2004
  • 자기장 측정기 교정 및 자기관련 시험 등에 사용되는 직류 및 교류 자기장 표준시스템을 제작하였다. 자기장 1 mT범위에서, 직류의 경우 확장불확도(expanded uncertainty, 2$\sigma$)는 8${\times}$$10^{-6}$, 교류의 경우, 주파수에 따른 확장불확도는 0.1~1 kHz 범위에서 0.16%, 1~5kHz에서 0.26%, 5~20kHz에서 0.44%이었다. 또한 국가측정표준에 대한 동등성과 수행한 교정 및 측정에 대한 국가간 상호인정을 받기 위하여 이 분야의 핵심측정표준 국제비교(international key comparison)에 참여하였다. 선진국과 대등한 결과를 얻었으며, 자기장 분야의 측정능력이 세계적 수준임을 확인하는 계기가 되었다.

GUM 표준안 기반 이동식 ADCP 유량 측정 불확도 평가 (Uncertainty Assesment for Moving-boat ADCP Discharge Measurements by GUM Framework)

  • 김동수;김종민
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2017년도 학술발표회
    • /
    • pp.71-71
    • /
    • 2017
  • 하천에서 평수기 유량측정은 도섭법을 이용하기 위한 지점식 측정보다는 초음파 도플러 유속계(ADCP, Acoustic Doppler Current Profiler)를 보트에 탑재하여 운용하는 측정 방식이 점차 일반화되고 있다. ADCP는 초음파의 도플러효과를 이용하여 수심이나 횡방향의 유속 분포를 측정할 수 있는 측정 장비로 일반적으로 사용되는 down-looking ADCP는 수심방향의 유속분포와 수심을 측정하여 보트의 이동속도와의 벡터 내적을 이용하여 유량을 산정하게 된다. 그러나, 이동식 ADCP 유량 측정 성과의 불확도는 제공되지 않고 있는 상황인데, 이는 불확도 산정 표준안 미비, 유속 및 수심 등 측정 요소의 관측 환경 별 불확도 정보 부족, 불확도를 산정할 수 있는 툴의 부재 등에 기인한다. 본 연구에서는 이동식 ADCP 불확도 산정 표준안을 개발하고 현장 실험을 통해 불확도 요인에 대한 규명, 불확도를 편리하게 산정할 수 있는 툴을 개발하고자 하였다. 불확도 산정 표준안으로 최근 WMO를 위시한 국제적으로 하천 유량 측정 불확도 표준안으로 채택되고 있는 GUM(Guide to the Expression of Uncertainty Measurement)을 기반으로 이동식 ADCP 유량 산정 알고리즘을 적용하여 불확도 적용 기법을 개발하였다. GUM 표준안을 기반으로 유량 측정불확도를 산정하기 위한 불확도 요인분석은 실규모 하천의 특성을 대부분 모의할 수 있는 한국건설기술연구원의 안동하천실험센터에서 수행된 실험자료를 기반으로 다양한 인자들에 대한 요소 별 불확도 분석을 수행하였다. GUM 표준안에 의하면 불확도 요인들은 오차전파의 법칙에 기반하여 전체 불확도에 전파되며, 이렇게 합성된 불확도는 t-분포의 신뢰수준 95%일 경우의 보정계수 2를 곱하여 최종적으로 확장불확도를 산정하게 된다. 이동측정방식의 ADCP의 경우 GUM 표준안에 적용하여 불확도를 평가하기 위해서 사용되는 수식이 방대하고, 매우 복잡하기 때문에 이를 실무자가 평가하기에는 한계가 있다. 이에 따라 본 연구에서는 ADCP의 유량 측정불확도를 보다 편리하게 평가하기 위하여 ADCP 유량 측정불확도 평가 소프트웨어인 AQUA(ADCP Discharge Uncertainty Assesment)를 개발하였으며, 이를 통해 실무자나 연구자들이 ADCP의 불확도 평가에 보다 편리하게 접근할 수 있을 것이라 판단된다.

  • PDF

BTEX 분석용 토양 숙련도 표준시료(PTMs) 개발에 관한 연구 (A Study on the Development of Soil-based PTMs for Analysis of BTEX)

  • 이민효;이군택;이법열;이원석;김금희;홍석영
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제18권5호
    • /
    • pp.15-25
    • /
    • 2013
  • In this study, two kinds of soil-based proficiency testing materials (PTMs), NICE-012L and NICE-012R were prepared and certified for Benzen, Toluene, Etylbenzene and Xylene with evaluation of uncertainties. In order to analyse BTEX (Benzen Toluene Etylbenzene Xylene) for the candidate materials, GC/MS was used after pretreatment according to methods of soil analysis by Ministry of Environment. For the homogeneity test among bottles in terms of candidate materials, ISO 13528 and IUPAC Protocol were used and according to the result, both candidate materials showed sufficient homogeneity. Also, the stability test over the candidate materials was accessed according to the ISO Guide 35 by classifying short-term and long-term stability and the result showed that both candidate materials showed decent stability. The reference values of the two candidate materials depending on BTEX components were derived from the average of the 11 samples that were used for verification of the samples' homogeneity. Uncertainty of measurement was combined by uchar that was caused by a characteristic value, $u_{bb}$ that was caused by between-bottle homogeneity, and $u_{stab}$ that was caused by stability, and then combined uncertainty ($u_{PTM}$) was multiplied to the coverage factor (k) derived from the effective degree of freedom from each factor that leads to expanded uncertainty (U) in about 95% of confidence level. The proficiency testing materials developed through this study were supplied to National Institute of Environmental Research (NIER) and utilized as an external proficiency testing materials for evaluating analysis capacity of soil agencies with specialty in terms of soil analysis approved by Minister of Environment.

중성자, 감마선, 엑스선 방사선 측정 및 통합 제어 시스템 개발 (Development of Neutron, Gamma ray, X-ray Radiation Measurement and Integrated Control System)

  • 고태영;이주현;이승호
    • 전기전자학회논문지
    • /
    • 제21권4호
    • /
    • pp.408-411
    • /
    • 2017
  • 본 논문에서는 중성자, 감마선, 엑스선 등의 방사선을 측정하는 통합 제어 시스템을 제안한다. 제안하는 시스템은 원격 또는 네트워크상으로 측정 및 분석한 데이터를 디스플레이를 통해 모니터링 및 제어할 수 있는 장비로서, 현장에 가지 않고도 시스템 각 구성 부분의 상태를 보고 변경하여 원격으로 감시 및 관리할 수 있다. 제안하는 시스템은 감마선/엑스선 센서부, 중성자 센서부, 주제어 임베디드 시스템부, 전용 디스플레이 장치 및 GUI부, 원격 UI부 등으로 구성된다. 감마선/엑스선 센서부는 NaI(Tl) Scintillation Detector를 사용하여 저준위의 감마선 및 엑스선을 측정한다. 중성자 센서부는 Proportional Counter Detector(저준위 중성자)와 Ion Chamber Type Detector(고준위 중성자)를 사용하여 중성자를 측정한다. 주제어 임베디드 시스템부는 방사선을 검출하여 초단위로 샘플링하고 누적된 펄스 및 전류값에 대한 방사선량으로 변환한다. 전용 디스플레이 장치 및 GUI부는 방사선 측정 결과와 변환된 방사선량 및 방사능량 측정 수치를 출력하고, 사용자에게 제어 조건 설정 및 검출부에 대한 캘리브레이션 기능을 제공한다. 원격 UI부는 측정된 값들을 취합, 저장하여 원격 감시 시스템에 전달한다. 제안된 시스템의 성능을 평가하기 위하여 공인시험기관에서 실험한 결과는 중성자 검출부는 ${\pm}8.2%$ 이하의 측정 불확도가 측정되었고, 감마선, 엑스선 검출부는 7.5%이하의 불확도가 측정되어 국제 표준인 ${\pm}15%$ 이하에서 정상동작 됨이 확인되었다.

면류에서 HPLC를 이용한 데옥시니발레놀 분석법의 검증과 불확도 산정 (Single Laboratory Validation and Uncertainty Estimation of a HPLC Analysis Method for Deoxynivalenol in Noodles)

  • 옥현이;장현주;강영운;김미혜;전향숙
    • 한국식품위생안전성학회지
    • /
    • 제26권2호
    • /
    • pp.142-149
    • /
    • 2011
  • 본 연구에서는 면류에서 면역친화컬럼을 이용한 데옥시니발레놀의 HPLC분석법을 검증하고, 분석과정에서 발생될 수 있는 불확도를 GUM 지침에 따라 측정하였다. 검출한 계와 정량한계는 7.5 ${\mu}g$/kg과 18.8 ${\mu}g$/kg이었고 검량선은 20~500 ${\mu}g$/kg 농도범위 에서 0.9999의 높은 상관성을 보였다. 대표적인 밀 가공품인 건면과 라면에 데옥시니 발레놀을 200 ${\mu}g$/kg과 500 ${\mu}g$/kg을 첨가하여 회수율과 반복성올 측정한 결과, 건면에서는 $82{\pm}2.7%$$87{\pm}1.3%$의 결과를 얻었고, 라면에서는 $97{\pm}1.6%$$91{\pm}12.0%$로 측정되었다. 한편, 불확도 측정을 위한 첫 단계로, 분석과정에서의 불확도 요인은 시료량 측정, 최종 시료부피, 보관표준용액, 작업표준용액, 표준용액, 기기, 매질, 검량선 작성으로 구분하였다. 불확도 요인의 구성요인은 저울의 안정성, 분해능, 재현성, 표준물질의 순도, 분자량, 농도, 표준용액 희석, 검량선, 회수율 및 분석기기의 재현성 풍이 작용하였다. 건면과 라면에 데옥시니발레놀을 200과 500 ${\mu}g$/kg을 첨가하여 분석한 결과 건면에서는 $163.8{\pm}52.1\;{\mu}g$/kg, $435.2{\pm}91.6\;{\mu}g$/kg으로 측정되었고 라면에서는 $194.3{\pm}33.0\;{\mu}g$/kg, $453.2{\pm}91.1\;{\mu}g$/kg으로 측정되었다. 확장불확도는 합성표준불확도에 포함인자(k=2, 신뢰수준 95%)를 곱하여 산출하였다. 건면과 라면에서 데옥시니발레놀을 분석함에 있어 불확도에 영향을 주는 주요인자는 시료의 회수율과 검량선 작성인 것으로 파악되었다. 따라서 면류 시료에서 데옥시니발레놀 것으로 분석의 정밀성을 높이기 위해서는 회수율과 검량선 작성에 영향을 끼칠 수 있는 분석과정을 확인하고 오차를 최소화 할 수 있는 방안을 모색해야 할 것으로 사료된다.

기체용적계를 이용한 분동식 압력계용 기준분동의 새로운 부피측정 방법 (New Method of Volume Measurement for Reference Weights of a Pressure Balance Using a Gas Pycnometer)

  • 이용재;이우갑;모하메드;박연규;오재윤
    • 한국진공학회지
    • /
    • 제22권5호
    • /
    • pp.231-237
    • /
    • 2013
  • 본 연구에서는 분동식 기준압력계의 기준분동(reference weight)의 부피를 측정하는 새로운 측정방법인 기체용적계(gas pycnometer) 측정방법을 제안하였다. 제안된 측정방법에 의한 측정결과로서 기준분동 1 kg, 2 kg, 5 kg에 대한 부피 측정불확도는 신뢰수준 95%에서 0.2%를 나타내었다. 기체용적계의 주요 장치는 샘플용기와 팽창용기, 정밀압력계, 정밀온도계, 진공펌프로 구성되며, 측정 원리는 일정한 용기 내에 들어 있는 일정한 양의 기체의 압력과 부피는 서로 반비례한다는 보일(boyle's law)의 법칙을 용용하였다. 본 결과는 현재까지 문헌이나 제조사로부터 기준분동 재질에 대한 밀도값을 적용하여 오던 것을 기준분동의 부피를 직접 측정하여 밀도값을 적용함으로서 압력기준기의 압력 기준값에 대한 국가측정표준의 신뢰도 향상에 기여될 것이다.

GM Tube 및 NaI(TI) 검출기를 사용한 Wide-Range 방사선 측정 시스템의 설계 (Design of Wide-Range radiation measurement system using GM Tube and NaI(TI) Detector)

  • 라승탁;이주현;이승호
    • 전기전자학회논문지
    • /
    • 제21권2호
    • /
    • pp.146-149
    • /
    • 2017
  • 본 논문에서는 GM Tube 및 NaI(TI) 검출기를 사용한 Wide-Range 방사선 측정 시스템을 제안한다. 제안하는 시스템은 NaI(Tl) 검출기 및 GM Tube의 검출기 신호를 제어, 계수할 수 있게 최적화한 하나의 소형 모듈로 설계한 다. 방사선량은 2개의 검출기를 연동하여 Wide-range인 0.1uSv/h~10mSv/h 구간에서 측정되고, 측정구간이 중복되는 지점인 10uSv/h~100uSv/h에서는 2개의 검출기가 동시에 동작한다. 방사선량은 중첩된 방사선 측정 가능 구간에 대해 적정한 구간에서 해당 검출기 기능의 On/Off를 제어하는 Wide-Range 방사선 측정 알고리즘을 이용하여 선택 적용하였다. 제안된 시스템의 성능을 평가하기 위하여 공인시험기관에서 실험한 결과, 각 구간별로 측정 불확도가 ${\pm}7.5%$로 측정되어 국제 표준인 ${\pm}15%$ 이하에서 정상동작 됨이 확인되었다.