• 제목/요약/키워드: Two parallel-plate

검색결과 202건 처리시간 0.028초

중주파수 대역 해석을 위한 Beam-plate-beam 연성 구조물의 웨이브 모형 연구와 시험적 규명 (Wave Models and Experimental Studies of Beam-plate-beam Coupled Systems for a Mid-frequency Analysis)

  • 유지우
    • 한국소음진동공학회논문집
    • /
    • 제17권2호
    • /
    • pp.121-129
    • /
    • 2007
  • There has been much effort to find suitable methods for structural analysis in the mid-frequency region where traditional low frequency methods have increasing uncertainties whilst statistical energy analysis is not strictly applicable. Systems consisting of relatively stiff beams coupled to flexible plates have a particularly broad mid-frequency region where the beams support only a few modes whilst the plate has a high modal density and modal overlap. A system of two parallel beams coupled to a plate is investigated based on the wave method, which is an approximate method. Muller's method is utilised for obtaining complex roots of a dispersion wave equation, which does not converge in the conventional wave method based on a simple iteration. The wave model is extended from a single-beam-plate system, to a plate with two identical beams which is modelled using a symmetric-antisymmetric technique. The important hypothesis that the coupled beam wavenumber is sufficiently smaller than the plate free wavenumber is experimentally verified. Finally, experimental results such as powers and energy ratios show the validity of the analytical wave models.

스펙트럴유한요소법을 이용한 네 변이 단순지지 된 직사각형평판의 진동해석 (Analysis of Simply Supported Rectangular Plate Using Spectral Finite Element Method)

  • 주경림;홍석윤;송지훈;김동진
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계 학술대회논문집(수송기계편)
    • /
    • pp.85-89
    • /
    • 2005
  • For the analysis of a vibrating two dimensional structure such as the simply supported rectangular plate, Spectral Finite Element Method (SFEM) has been studied. Under the condition that two parallel edges are simply supported at least and the other two edges can be arbitrary, Spectral Finite Element has been developed. Using this element SFEM is applied to the vibrating rectangular plate which all edges are simply supported, and obtain the frequency response function in frequency domain and the dynamic response in time domain. To evaluate these results normal mode method and finite element method (FEM) are also accomplished and compared. It is seen that SFEM is more powerful analysis tool than FEM in high frequency range.

  • PDF

두개의 평행한 축방향 관통균열이 존재하는 증기발생기 세관의 최적 파손예측모델 (Optimum Failure Prediction Model of Steam Generator Tube with Two Parallel Axial Through-Wall Cracks)

  • 이진호;송명호;최영환;김낙철;문성인;김영진
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.1186-1191
    • /
    • 2003
  • The 40% of wall criterion, which is generally used for the plugging of steam generator tubes, may be applied only to a single crack. In the previous study, a total of 9 failure models were introduced to estimate the local failure of the ligament between cracks and the optimum coalescence model of multiple collinear cracks was determined among these models. It is, however, known that parallel axial cracks are more frequently detected during an in-service inspection than collinear axial cracks. The objective of this study is to determine the plastic collapse model which can be applied to the steam generator tube containing two parallel axial through-wall cracks. Nine previously proposed local failure models were selected as the candidates. Subsequently interaction effects between two adjacent cracks were evaluated to screen them. Plastic collapse tests for the plate with two parallel through-wall cracks and finite element analyses were performed for the determination of the optimum plastic collapse model. By comparing the test results with the prediction results obtained from the candidate models, a plastic zone contact model was selected as an optimum model.

  • PDF

Pull-in과 release 전압차 감소용 돌기구조를 갖는 비틀림형 초소형 기계적 스위칭 소자 (Torsional Micromechanical Switching Element Including Bumps for Reducing the Voltage Difference Between Pull-in and Release)

  • 하종민;한승오;박정호
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제50권9호
    • /
    • pp.471-475
    • /
    • 2001
  • ln this paper, a micromachined micromechanical switch is presented. The presented switch is operated in the vertical direction to the substrate by an electrostatic force between two parallel plates. The moving plate is pulled down to connect the bumps of the bias node$(V_{DD}/ or GND)$ to the bumps of the output node when a oltage difference exists between the moving plate and the input plate. The switch was designed to operate at a low switching voltage$(\risingdotseq5V)$ by including a large-area, narrow-gap, parallel plate capacitor A theoretical analysis of the designed switch was performed in order to determine its geometry fitting the desired pull-in voltage and release voltage. The designed switch was fabricated by surface micromachining combined with Ni electroplating. From the experimental results of the fabricated switch, its pull-in voltage came Out to be less than 5V and the measured maximum allowable current was 150mA. The measured average ON-state resistance was about 8$\Omega$, and the OFF-state resistance was too high to be measured with digital multimeter.

  • PDF

Estimation of surface emissivity for conduction-cooled metal plates at cryogenic temperatures

  • Chang, Ho-Myung;Lee, Gyong-Hyon
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제10권2호
    • /
    • pp.38-41
    • /
    • 2008
  • The relation between surface emissivity and temperature distribution is experimentally and analytically investigated for a conduction-cooled metal plate in vacuum. Experimental set-up consists of a rectangular metal plate placed vertically in a cryostat and thermally anchored to the coldhead of a GM cryocooler at the top. Temperature is measured at a number of locations over the plate with platinum resistors mounted on the plate. A parallel analysis on the balance of heat conduction through the plate and thermal radiation on its surface is performed to numerically calculate the temperature distribution having the same boundary conditions as experiment. By comparing the two results, an average emissivity of the plate is roughly estimated for different metal plates and different surface conditions. The estimated emissivity in present study is less than the listed values for highly polished stainless steel, and meets a fairly good agreement for oxidized copper surface.

존가점성 유체를 이용한 동력전달 장치에 관한 연구 (STUDY ON TORQUE CONVERTER USING ELECTRO-RHEOLOGICAL FLUID)

  • 이은준;박명관;주동우
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1995년도 추계학술대회 논문집
    • /
    • pp.542-545
    • /
    • 1995
  • This paper provides an investigation of torque converter system using ERF (Electro-Rheological Fluid). The torque converter system using ERP is a new concepting device because we can change an apparent viscosity of ERF by adapting an electric field. The device was designed by using the equations which were proposed by Carlson et al. The devices based on ERF generally assume one two possible forms. One is the parallel plate type in which the device elements are facing circular disks separated by a flat layer of ERF, The other is coaxial cylinder or Couette types in which the ERF file the annular apace between a pair of coaxial cylindrical electrode. The discussion on this study is specifically for coaxial cylinder gemetry and experiment results show that the measured torque was rapidly increased with the increase of the eletric field.

  • PDF

손가락 힘측정장치의 3축 힘센서 설계 (Design of a Three-Axis Force Sensor for Finger Force Measuring System)

  • 이경준;김갑순
    • 센서학회지
    • /
    • 제25권2호
    • /
    • pp.110-115
    • /
    • 2016
  • This paper describes the design and fabrication of a three-axis force sensor with three parallel plate structures(PPSs) for measuring force in a finger force measuring system for a spherical object catch. The three-axis force sensor is composed of a Fx force sensor, Fy force sensor and a Fz force sensor, and the elements of Fx force sensor and Fy force sensor are a parallel plate structure(PPS) respectively and Fz force sensor is two PPS. The three-axis force sensor was designed using FEM(Finite Element Method), and manufactured using strain-gages. The characteristics test of the three-axis force sensor was carried out. As a test results, the interference error of the three-axis force sensor was less than 1.32%, the repeatability error of each sensor was less than 0.04%, and the non-linearity was less than 0.04%.

임의 형태의 개구에 의한 평행평판 도파관으로의 전자기적 결합 문제 해석을 위한 적분 방정식 방법 (Integral equation formulation for electromagnetic coupling through an arbitrarily shaped aperture into a parallel-plate waveguide)

  • 이영순;이창원;조영기;손현
    • 전자공학회논문지A
    • /
    • 제32A권12호
    • /
    • pp.25-35
    • /
    • 1995
  • An analysis method of electromagnetic coupling through an arbitrarily shaped aperture on the upper wall of parallel-plate waveguide, when excited by an electromagnetic plane wave from outside, is considered. The mixed-potential integral equation, in which Green's functions are expressed in a computationally efficient closed form by using the Prony's method and the Sommerfeld identity, is formulated. Expanding the unknown equivalent magnetic surface current in terms of two-dimensional rooftop-type basis functions and choosing razor testing, the integral equation is reduced to a linear algebraic equation, which is solved. The results are compared with the previous results. Fairly good agreements between them are observed.

  • PDF

MOCVD 반응로내 GaN 성장에 미치는 입구형상의 영향 (Effect of inlet configuration on the growth rate of GaN layer in a MOCVD reactor)

  • 윤성규;백병준;박복춘
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.67-72
    • /
    • 2003
  • Numerical calculation has been performed to investigate the effect of inlet configuration on the growth rate of GaN layer on the heated susceptor. The conventional single inlet, where the gas is mixed by force in the inlet, is compared with separated flow inlet. Two-parallel gas flow $H_{2}$ and $NH_{3}$ are separated by a plate with finite length which are also parallel to the susceptor. The effect of separated plate length, carrier gas and flow rate of each precursor on the mixing of reactant gases and growth rate were investigated. Furthermore the three dimensional model is employed to predict the transverse variation of growth rate.

  • PDF

Orthogonal versus Parallel Plating for Distal Humeral Fractures

  • Moon, Jun-Gyu;Lee, Ji-Ho
    • Clinics in Shoulder and Elbow
    • /
    • 제18권2호
    • /
    • pp.105-112
    • /
    • 2015
  • In orthopedic trauma surgery, treatment of intraarticular distal humerus fractures is a challenge. With development of implants and biomechanical studies, surgical strategies with recommendations including preoperative computed tomography images, proper approaches and open reduction and internal fixation with dual plates have emerged. In addition, as an effort to provide stable fixation to permit early elbow motion, different methods of internal fixation, particularly plate configuration, have evolved. Using dual plates, either oriented parallel to each other or orthogonal, stable fixation has been achieved and satisfactory clinical outcomes have been reported. With rationales and advantages/disadvantages of each plate configuration, both techniques are selected according to surgeons' preference, and, in specific cases, one could be preferred over another. The key to successful fixation by either technique is obtaining anatomical reduction with restoration of two stable columns of the distal humerus.