• Title/Summary/Keyword: Two electrodes

Search Result 897, Processing Time 0.028 seconds

Particle-motion-tracking Algorithm for the Evaluation of the Multi-physical Properties of Single Nanoparticles (단일 나노입자의 다중 물리량의 평가를 위한 입자 모션 트랙킹 알고리즘)

  • Park, Yeeun;Kang, Geeyoon;Park, Minsu;Noh, Hyowoong;Park, Hongsik
    • Journal of Sensor Science and Technology
    • /
    • v.31 no.3
    • /
    • pp.175-179
    • /
    • 2022
  • The physical properties of biomaterials are important for their isolation and separation from body fluids. In particular, the precise evaluation of the multi-physical properties of single biomolecules is essential in that the correlation between physical and biological properties of specific biomolecule. However, the majority of scientific equipment, can only determine specific-physical properties of single nanoparticles, making the evaluation of the multi-physical properties difficult. The improvement of analytical techniques for the evaluation of multi-physical properties is therefore required in various research fields. In this study, we developed a motion-tracking algorithm to evaluate the multi-physical properties of single-nanoparticles by analyzing their behavior. We observed the Brownian motion and electric-field-induced drift of fluorescent nanoparticles injected in a microfluidic chip with two electrodes using confocal microscopy. The proposed algorithm is able to determine the size of the nanoparticles by i) removing the background noise from images, ii) tracking the motion of nanoparticles using the circular-Hough transform, iii) extracting the mean squared displacement (MSD) of the tracked nanoparticles, and iv) applying the MSD to the Stokes-Einstein equation. We compared the evaluated size of the nanoparticles with the size measured by SEM. We also determined the zeta-potential and surface-charge density of the nanoparticles using the extracted electrophoretic velocity and the Helmholtz-Smoluchowski equation. The proposed motion-tracking algorithm could be employed in various fields related to biomaterial analysis, such as exosome analysis.

Comparison of Trunk Muscles between 3 Different Squats in Normal Adults

  • Aran Choi;Jihye Jung;Seungwon Lee
    • Physical Therapy Rehabilitation Science
    • /
    • v.13 no.1
    • /
    • pp.78-85
    • /
    • 2024
  • Objective: This Study aimed to examine the changes in muscle activity of trunk muscles by performing three squat exercises on normal adults. Design: cross-sectional study Methods: Thirty-two adult subjects participated in this study. General squat, overhead squat, and overhead squat combined with abdominal stabilization were randomly performed for 5 seconds, 3 times, to calculate the average muscle activation. Muscle activation was normalized using electrodes on the rectus abdominis, external oblique, internal oblique, and erector spinae muscles to measure maximum voluntary isometric contraction (MVIC) for 5 seconds, repeated 3 times each. Results: There was a significant difference in the mean and maximal muscle activity of the bilateral erector spinae (ES) when comparing the squat to the overhead squat (p<0.05). There was a significant difference (p<0.05) in the mean and maximal muscle activity of the bilateral external oblique (EO) when comparing the overhead squat to the overhead squat combined with the abdominal stabilization technique. When comparing the squat to the overhead squat with abdominal stabilization, there was a significant difference in the mean and maximum muscle activity of the bilateral RA, EO, and left Internal oblique (IO) (p<0.05), and there was a significant difference in the maximum muscle activity of the bilateral erector spinae (ES) (p<0.05). Post hoc tests showed significant differences between squatting methods for the RA, EO, IO, and ES (p<0.017). Conclusion: The results of this study showed that squats combined with abdominal stabilization were more effective at activating core muscles than squats or overhead squats alone.

Numerical Studies of a Separator for Stack Temperature Control in a Molten Carbonate Fuel Cell (용융탄산염 연료전지 스택 온도 조절을 위한 분리판에 관한 수치 해석 연구)

  • Kim, Do-Hyung;Kim, Beom-Joo;Lim, Hee-Chun
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.22 no.3
    • /
    • pp.305-312
    • /
    • 2011
  • The use of a separator to control stack temperature in a molten carbonate fuel cell was studied by numerical simulation using a computational fluid dynamics code. The stack model assumed steady-state and constant-load operation of a co-flow stack with an external reformer at atmospheric pressure. Representing a conventional cell type, separators with two flow paths, one each for the anode and cathode gas, were simulated under conditions in which the cathode gas was composed of either air and carbon dioxide (case I) or oxygen and carbon dioxide (case II). The results showed that the average cell potential in case II was higher than that in case I due to the higher partial pressures of oxygen and carbon dioxide in the cathode gas. This result indicates that the amount of heat released during the electrochemical reactions was less for case II than for case I under the same load. However, simulated results showed that the maximum stack temperature in case I was lower than that in case II due to a reduction in the total flow rate of the cathode gas. To control the stack temperature and retain a high cell potential, we proposed the use of a separator with three flow paths (case III); two flow paths for the electrodes and a path in the center of the separator for the flow of nitrogen for cooling. The simulated results for case III showed that the average cell potential was similar to that in case II, indicating that the amount of heat released in the stack was similar to that in case II, and that the maximum stack temperature was the lowest of the three cases due to the nitrogen gas flow in the center of the separator. In summary, the simulated results showed that the use of a separator with three flow paths enabled temperature control in a co-flow stack with an external reformer at atmospheric pressure.

Diagnosis of Diabetes Using Voltage Analysis Based on EIS (Electro Interstitial Scan) (EIS 기반 전압신호 분석을 통한 당뇨병 진단 가능성 평가)

  • Bae, Jang-Han;Kim, Soochan;Kaewkannate, Kanitthika;Jun, Min-Ho;Kim, Jaeuk U.
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.11
    • /
    • pp.114-122
    • /
    • 2016
  • EIS (Electro interstitial scan) is a non-invasive and simple method to find the physio-pathological information inferred by electric current response with respect to low direct current applied between remote sites of the body. Although a few EIS-based devices for diagnosing diabetes were commercialized, they were not successful in offering clinical validity nor in confirming diagnostic principle. In this study, we measured the voltage responses of diabetic patients and normal subjects with a commercialized EIS device to test the usefulness of EIS in screening diabetes. For this purpose, voltage was measured between pairs of electrodes contacted at both palm, both soles of the feet and left and right forehead above both eyes. After feature extraction of voltage signals, the AUC (area under the curve) between the two groups was calculated and we found that seven variables were appropriately shown above 60% of accuracy. In addition, we applied the k-NN (k-nearest neighbors) method and found that the accuracy of classification between the two groups reached the accuracy of 76.2%. This result implies that the voltage response analysis based on EIS has potential as a diabetics screening method.

The Differences of EEG Coherence between Schizophrenia and Bipolar Disorder (정신분열병과 양극성장애에서 뇌파 동시성의 비교분석)

  • Kim, Yong-Kyu;Shin, Jae-Kong;Park, Chong-Won;Hong, Kyung Sue;Lee, Seung-Yeoun;Oh, Hong-Seok;Lee, Yong-Suk;Kwak, Yong-Tae;Chang, Jae Seung;Lee, Yu-Sang
    • Korean Journal of Biological Psychiatry
    • /
    • v.12 no.2
    • /
    • pp.123-135
    • /
    • 2005
  • Objectives:EEG coherence could imply the connectivity between two different areas of the brain, which is known to be important in the pathophysiology of bipolar I disorder(BPD I) and schizophrenia. The authors investigated EEG coherence in patients with BPD I and schizophrenia to examine the connectivity of the neural circuit. Methods:EEGs were recorded in 15 schizophrenia and 14 bipolar disorder patients, and 14 age-matched normal control subjects from 16 electrodes with linked-ear reference. Spectral parameters and coherence were calculated for the alpha bandwidth(8-13Hz) by a multi-channel autoregressive model using 20 artifact-free 2-seconds epochs and the differences were compared among three groups by two different statistical methods;F-test and Kruskal-Wallis test. Furthermore, when there were significant differences among three groups, Scheffe's multiple comparison tests were provided and Jonckheere-Terpstra tests for the ordered alternative were given. Results:In the intra-hemispheric comparison, left frontal coherence was increased in order of control, BPD I and schizophrenia. In the inter-hemispheric comparison, 1) inter-prefrontal coherence in BPD I was signifi- cantly higher than in normal controls, and 2) inter-prefrontal coherence in schizophrenia was significantly lower than in controls. Conclusion:These results suggest that 1) both schizophrenia and BPD I are diseases having the abnormality of neural circuit connectivity in both frontal and prefrontal lobes, and 2) the abnormality is more severe in schizophrenia than in BPD I. Furthermore, the data support that a common pathogenetic process may reside in both schizophrenia and BPD I.

  • PDF

A Study on the Design of Functional Clothing for Vital sign Monitoring -Based on ECG Sensing Clothing- (생체신호 측정을 위한 기능성 의류의 디자인 연구 -심전도 센싱 의류를 중심으로-)

  • Cho, Ha-Kyung;Song, Ha-Young;Cho, Hyeon-Seong;Goo, Su-Min;Lee, Joo-Hyeon
    • Science of Emotion and Sensibility
    • /
    • v.13 no.3
    • /
    • pp.467-474
    • /
    • 2010
  • Recently, Study of functional clothing for Vital sensing is focused on reducing artifact by human motions, in order to enhance the electrocardiogram(ECG) sensing accuracy. In this study, considering the factors for each element found from the analysis, a 3-lead electrode inside textile embroidered with silver yarn was developed, and draft designs off our types of vital-signal sensing garments, which are 'chest-belt typed' garment, 'cross-typed' garment 'x-typed' garment and 'curved x-typed' garment, were prepared. The draft designs were implemented on a sleeveless male shirt made of an elastic material so that the garment and the electrodes can remain closely attached along the contour of the human body, and the acquired data was sent to the main computer over a wireless network. In order to evaluate the effects caused by body movements and the ECG-sensing capability for each type in static and dynamic states, displacements were measured from one and two dimensional perspectives. ECG measurement evaluation was also performed for Signal-to-noise ratio(SNR) analysis. Applying the experimental results, the draft garment designs were modified and complemented to produce two types of modular approaches 'continuous-attached' and 'insertion-detached' for the ECG-sensing smart clothing.

  • PDF

Effect of Hippocampectomy on Gastric Ulceration by Predicted Stress (예보된 스트레스에 의한 위궤양 발생에 미치는 뇌 해마 제거의 영향)

  • Kim, Chul;Choi, Hyun;Kim, Chung-Chin;Kim, Jong-Kyu;Kim, Myung-Suk;Park, Hyoung-Jin;Jo, Yang-Hyeok
    • The Korean Journal of Physiology
    • /
    • v.14 no.1
    • /
    • pp.1-5
    • /
    • 1980
  • This study was under taken to investigate the influences of predictable or unpredictable stress upon gastric ulceration, and the hippocampectomy upon the ulceration order the stressful conditions. Sixty male albino rats(Sprague-Dawley strain) were divided equally into 3 groups: One was the hippocampal group(N=20) which received hippocampal ablation by suction, another was the cortical control group(N =20) which received partial cortical ablation over the hippocampus, and a third was the normal control group(N=20). Each group was further divided into two subgroups: One was the predicted subgroup(N=10) in which animals could predict the imminent stressful stimuli by hearing a sound(1,000 Hz, 2 sec in duration) 3 sec before the onset of the stress, and the other was the unpredicted subgroup(N=10). After starvation for 24 hours, but water ad libitum, each rat received the electric stimulation(3 mA, 60 Hz, 2 sec in duration, and once per minute in average) for 6 hours via a pair of electrodes attached on the tale. The electric stimulation served as the stress causing the gastric ulcer. Five hours after completion of stimulation, the stomach filled with the physiological saline was removed under deep anesthesia and spread out on a small glass plate. The numbers of the ulcer in each stomach were counted and the shape was examined under the dissecting microscope. Results obtained were as follows: 1. The mean numbers of the ulcer of the predicted subgroups were significantly larger than those of the unpredicted subgroups in the normal control and the cortical control groups, but there was no difference between the values of the two subgroups in the hippocampal group. 2. The mean numbers of the ulcer of the predicted subgroups in the normal control and the cortical control groups were larger(but not significant) than that in the hippocampal group. It is inferred from the above results that the prediction of the stress strengthens the effect of the stress on the gastric ulceration, and the hippocampus facilitates the effect of the prediction of the stress.

  • PDF

The Efficacy of Repeated Radiofrequency Medial Branch Neurotomy for Lumbar Facet Syndrome

  • Son, Jung-Hee;Kim, Sang-Dae;Kim, Se-Hoon;Lim, Dong-Jun;Park, Jung-Yul
    • Journal of Korean Neurosurgical Society
    • /
    • v.48 no.3
    • /
    • pp.240-243
    • /
    • 2010
  • Objective : Radiofrequency (RF) medial branch neurotomy is an effective management of lumbar facet syndrome. However, pain may recur after period of time. When pain recurs, it can be repeated, but the successful outcome and duration of relief from repeated procedures are not clearly known. The objective of this study was to determine the success rate and duration of pain relief from repeated radiofrequency medial branch neurotomy for lumbar facet syndrome. Methods : A retrospective review of medical records was done on 60 consecutive patients, from March of 2006 to February of 2009, who had an initial successful RF neurotomy but subsequently underwent repeated procedures due to recurrence of pain. All procedures were done in carefully selected patients after at least two responsive medial branch nerve blocks. C-arm fluoroscopic guide, impedance, sensory and motor threshold monitoring tools were used for the precise placement of electrodes. Responses of repeated procedures were compared with initial radiofrequency neurotomy for success rates and duration of pain relief. Results : There were 48 females and 12 males. Mean age was 52.4 years (range, 26-83). RF medial branch neurotomy was done on one side in 38 and both sides in 22 patients, each covering at least three segments. Average visual analog scale at last procedure was 6.8. Twelve patients had previous lumbar operations, including 4 patients with instrumentations. Fifty-five patients had two procedures and five patients had three procedures. Mean duration of successful pain relief (> 50% of previous pain for at least 3 months period) after initial radiofrequency neurotomy was 10.9 months (range, 3-28) in 51 (85%) patients. From repeated procedures, successful pain relief was seen in 50 (91%) patients with average duration of 10.2 months (range, 3-24). Five patients had third procedure, which was successful in 4 (80%) patients with mean duration of 9.8 months (range, 5-16). This was not statistically different from initial results. There were no permanent neurological complications from the procedures. Conclusion : Results of this study indicate that the frequency of success and durations of relief from repeated RF medial branch neurotomy for lumbar facet syndrome are similar to initial results that provided relatively prolonged period of pain relief without major side effects Each procedure seems to provide successful pain relief for about 10 months in more than 85% of carefully selected patients when properly done.

Development of Epoxy Based Stretchable Conductive Adhesive (신축 가능한 에폭시 베이스 전도성 접착제 개발)

  • Nam, Hyun Jin;Lim, Ji Yeon;Lee, Chang Hoon;Park, Se-Hoon
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.27 no.3
    • /
    • pp.49-54
    • /
    • 2020
  • To attach a stretchable/flexible electrode to something or something to on electrode, conductive adhesives must be stretchable/flexible to suit the properties of the electrode. In particular, conductive adhesive require durability and heat resistance, and unlike conventional adhesives, they should also have conductivity. To this end, Epoxy, which has good strength and adhesion, was selected as an adhesive, and a plasticizer and a reinforcement were mixed instead of a two-liquid material consisting of a conventional theme and a hardener, and a four-liquid material was used to give stretchability/flexibility to high molecules. The conductive filler was selected as silver, a material with low resistance, and for high conductivity, three shapes of Ag particles were used to increase packing density. Conductivity was compared with these developed conductive adhesives and two epoxy-based conductive adhesives being sold in practice, and about 10 times better conductivity results were obtained than products being actually sold. In addition, conductivity, mechanical properties, adhesion and strength were evaluated according to the presence of plasticizers and reinforcement agent. There was also no problem with 60% tensile after 5 minutes of curing at 120℃, and pencil hardness was excellently measured at 6H. As a result of checking the adhesion of electrodes through 3M tape test, all of them showed excellent results regardless of the mixing ratio of binders. After attaching the Cu sheet on top of the electrode through conductive adhesive, the contact resistance was checked and showed excellent performance with 0.3 Ω.

The Influence of Electromyographic Activation on Gluteus Medius and Tensor Fascia Lata by Functional Leg Length Discrepancy in Women's University Students During Lunge (여대생의 기능적 다리길이 차이가 런지 자세에서 중간볼기근, 넙다리근막긴장근의 근활성도에 미치는 영향)

  • Kim, Hae-Ree;Song, Ye-Jin;Moon, Sung-Gi;Jang, Hyun-Jeong
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.19 no.2
    • /
    • pp.39-46
    • /
    • 2013
  • Background: The purpose of this study was to realize the relations between gluteus medius, tensor fascia lata of pelvic muscles and functional leg length in women's university students. This study is examined the change of electromyographic activation on gluteus medius and tensor fascia lata according to the leg length discrepancy. Methods: All of the female of freshman and sophomore in 'D'college were gathered and separated fourteen of healthy women in two groups by functional leg length discrepancy. and The subjects divided into two groups that the difference with less than 2cm or more would have structural defects by tapeline. The electromyographic activation on the gluteus medius and tensor fascia lata muscles were recorded by surface electrodes at maximal voluntary isometric contraction (MVIC) during lunge posture. The collected datas were analyzed using Independent t-test with SPSS win19.0. Results: In intergroup comparison of electromyographic activation levels for gluteus medius and tensor fascia lata in short or long leg, the influence of electromyographic activation on tensor fascia lata is shown to be more statically higher than gluteus medius according to functional leg length discrepancy in coeds. Even though both muscles are shown to be statistically higher in comparison of electoromyographic activation levels for tensor fascia lata and gluteus medius between short leg and long leg in Group I, Differences of electoromyographic activation levels for tensor fascia lata is shown to be statistically higher than gluteus medius. Conclusion: Through this study, we realized that tensor fascia lata than the long leg, and also, tensor fascia lata is significantly effective for functional leg length discrepancy than gluteus medius. It leads to pelvic lateral instability. This means that cause tensor fascia lata to have a leg length discrepancy.

  • PDF