• 제목/요약/키워드: Tube conductivity

검색결과 161건 처리시간 0.031초

Platinum and carbon nano tube addition in carbon black counter electrode for dye-sensitized solar cells

  • Lee, Su Young;Kim, Sang Ho
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2012년도 춘계학술발표회 논문집
    • /
    • pp.229-230
    • /
    • 2012
  • Platinum (Pt) has been commonly used as a counter electrode material in dye-sensitized solar cells, because it has high catalytic activity and electric conductivity as well as chemical inertness with iodide electrolyte. However, Pt is too expensive to be commercialized. Therefore, in the present study, carbon black counter electrode with Pt and carbon nano tube (CNT) was investigated. The power conversion efficiency with Pt added carbon black electrode was lower than hat of pure Pt electrode which was 6.47 %. By adding 3 wt% Pt to the carbon black counter electrode, the power conversion efficiency was maximized at 5.88 %. On them, additional adding of 1 wt % CNT, the power conversion efficiency (${\eta}$)wasincreasedupto6.21%. The reason of power conversion efficiency improvement with a proper amount of Pt and CNT was examined by comparing the impedance properties measured using EIS.

  • PDF

Al-황동의 응력부식균열 특성에 미치는 인가전위의 영향 (Effect of Impressed Potential on the SCC of Al-Brass)

  • 정해규;임우조
    • 한국해양공학회지
    • /
    • 제18권1호
    • /
    • pp.69-74
    • /
    • 2004
  • In general, the protection method of Shell and Tube Type heat exchanger for a vessel has been applied as a sacrificial anode, which is attached at the inner side of the shell. However, this is an insufficient protection method for tube. Therefore, a more suitable method, such as the impressed current cathodic protection for tube protection, is required. Al-brass is the raw material of tubes for heat exchanger of a vessel where seawater is used for cooling the water. It has a high level of heat conductivity, excellent mechanical properties, and a high level of corrosion resistance, due to a cuprous oxide (Cu$_2$O) layer against th seawater. However, in actuality, it has been reported that Al-brass tubes for heat exchanger of a vessel can produce local corrosion, such as stress corrosion cracking (SCC). This paper studied the effect of impressed potential on the stress corrosion cracking of Al-brass for impressed current cathodic protection in 3.5% NaCl +0.1% NH$_4$OH solution, under flow by a constant displacement tester. Based on the test results, the latent time of SCC, stress corrosion crack propagation, and the dezincification phase of Al-brass are investigated.

CW $CO_{2}$ 레이저의 온도 특성에 관한 해석 (The theoretical analysis of characteristics for temperatures in cw $CO_{2}$ laser)

  • 강동헌;박득일;이주희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 전기.전자공학 학술대회 논문집
    • /
    • pp.465-468
    • /
    • 1988
  • The output power is dependent of the vibrational level temperatures and wall temperature of the discharge tube in cw $CO_{2}$ lasers. The method postulates the introduction of a vibrational temperatures Ti for each vibrational mode. The vibrational and wall temperature are dertermined by the equations of the vibrational energy balance and thermal conductivity.

  • PDF

Floating Zone법에 의한 Rutile($TiO_2$)단결정 육성 (Growth of Rutile Single Crystal by Floating Zone Method)

  • 신재혁;강승민;오근호
    • 한국세라믹학회지
    • /
    • 제27권8호
    • /
    • pp.1050-1054
    • /
    • 1990
  • Rutile(TiO2) single crystals were grown by FZ method. Feed rod was sintered in the longitudinal tube-shaped furnace at 135$0^{\circ}C$ and optimum growth condition was growth rate 5-8mm/hr, rotation rate 30-40rpm. When crystal was growing, atomosphere was oxidized condition, and grown single crystal was annealed at 110$0^{\circ}C$. The rutile single crystals were oriented to [001] direction and color change of single crystals were related to atmosphere, and difference of electric conductivity and resistance was due to the fact above.

  • PDF

고전압 전기장을 이용한 하수처리장 방류수 중의 대장균군 소독에 관한 연구 (A Study on the Disinfection of Coliform Group in the Effluent of Sewage Plant by High Voltage Electric Field Treatment)

  • 이민규;정근식;감상규
    • 한국환경과학회지
    • /
    • 제17권7호
    • /
    • pp.817-826
    • /
    • 2008
  • Using high voltage electric fields induced by high voltage AC (10-12 kV/cm, 20 kHz) and pulsed (20-30 kV/cm, 40 Hz) electric field generator as a semipermanent and environment-friendly disinfecting apparatus, the disinfection effect of coliform group in the effluent of sewage plant was investigated. The effects of electric field strength, treatment time, discharge area of a discharge tube, water quality factors (electric conductivity, pH and SS) on its death rate were examined. The death rate of coliform group was increased with increasing electric field strength and treatment time. For AC and pulsed electric field generator, the critical electric field strength was 6 kV/cm and 2 kV/cm, respectively, and the critical treatment time was 5 min and 2 min, respectively, regardless of electric field strength. Comparing the death rate of coliform group by AC and pulsed electric fields used in this study, its death rate was higher for the latter than the former, but did not increase linearly with increasing electric field strength. The results obtained for the effects of discharge area, electric conductivity, pH and SS on the death rate of coliform group using AC electric field (12 kV/cm, 20 kHz) were as follows: its death rate showed the trend to increase linearly with increasing discharge area; for the effect of electric conductivity, its death rate was increased with increasing electric conductivity, regardless of ionic species, increased with increasing cationic valency, but was similar between the same cationic valency; the pH $5{\sim}9$ used in this study did not affect its death rate; its death rate was decreased with increasing SS concentration.

고분자 전해질막 수소 연료 전지 분리판 용 흑연/폴리프로필렌/액정고분자 복합 재료의 특성에 관한 연구 (Study on Graphite/Polypropylene/Liquid Crystalline Polymer Composite for a Bipolar Plate of Polymer Electrolyte Membrane Fuel Cell)

  • 비라즈 둔가나;손영곤
    • 한국산학기술학회논문지
    • /
    • 제16권5호
    • /
    • pp.3627-3632
    • /
    • 2015
  • 고분자 전해질 막 연료전지의 분리판 용 흑연/폴리프로필렌(PP)/액정고분자 (LCP) 복합소재의 기계적, 유변학 특성 및 전기전도도에 관하여 연구하였다. 저분자량 PP를 바인더로 사용하는 경우 다른 열가소성 고분자와 비교하여 상당히 높은 전기 전도도를 보임을 확인하였는데 이는 점도가 낮은 PP에 의해 흑연 입자의 분산이 향상되어 나타난 결과임을 확인할 수 있었다. 또한 탄소나노튜브를 소량 첨가하면 복합재료의 전기전도도가 크게 증가하였고 산처리를 하여 산소 관능기를 포함한 탄소나노튜브를 첨가했을 때에는 전기전도도의 증가가 거의 없었다. 이로부터 탄소나노튜브는 비극성 고분자와 친화도가 높음을 알 수 있었다. 저분자량 PP를 바인더로 사용하였을 때는 복합재료의 점도가 사출성형이 가능할 정도로 낮은 것을 관찰할 수 있었다. 그러나 기계적인 강도는 다른 고분자에 비해 현저히 낮았다. 이를 보강하기 위하여 LCP를 혼합하여 복합재료를 제조한 결과 전반적인 물성 밸런스가 잘 맞는 복합재료를 얻을 수 있었다.

B-stage 레진 필름의 카본나노튜브 분산도 평가 및 제조공정 최적화 (Carbon Nano Tube Dispersion Evaluation in B-stage Resin Films)

  • 오영석;박태훈;변준형;이진우;김병선;조치룡
    • Composites Research
    • /
    • 제29권6호
    • /
    • pp.353-357
    • /
    • 2016
  • B-stage 레진 필름에 탄소나노튜브(CNT) 등을 균일하게 분포시킨 뒤에 기타의 보강섬유 층과 함께 여러 겹으로 적층하여 하이브리드 형태의 복합재료를 만드는 방법은 유용하다. 본 연구에서는 CNT가 포함된 에폭시 레진으로부터 shear mixing 및 Three-roll mill 공정을 이용하여 B-stage 레진 필름을 제작하였다. 두 공정을 통해 형성된 CNT/레진 복합재 필름의분산도를 파단면의 SEM 관찰을통해분석하였다. 보다 효율적인 공정을 위해 Calendering pass 횟수에 따른 분산도를 평가하였다. Pass의 횟수에 따른 샘플을 제조하고 CNT 분산도는 SEM 이미지를 통해 확인하고, 전기 전도도 측정을 통해 분석하였다. 추가적으로 gap mode, force mode를 통해 제작한 각각의 샘플의 전기 전도도를 측정하여 CNT 분산도를 분석하였고 이를 통해 최적공정을 도출하였다.

펄스와전류를 이용한 보온재 비해체식 배관감육 평가기술 (Nondestructive evaluation of wall thinning covered with insulation using pulsed eddy current)

  • 박덕근;;이덕현
    • 한국압력기기공학회 논문집
    • /
    • 제10권1호
    • /
    • pp.90-95
    • /
    • 2014
  • Local wall thinning is a point of concern in almost all steel structures such as pipe lines covered with a thermal insulator made up of materials with low thermal conductivity(fiberglass or mineral wool); hence, Non Destructive Technique(NDT) methods that are capable of detecting the wall thinning and defects without removing the insulation are necessary. In this study we developed a Pulsed Eddy Current(PEC) system to detect the wall thinning of Ferro magnetic steel pipes covered with fiber glass thermal insulator and shielded with Aluminum plate. The developed system is capable of detecting the wall thickness change through an insulation of thickness 10cm and 0.4mm aluminum shielding. In order to confirm the thickness change due to wall thinning, two different sensors, a hall sensor and coil sensor were used as a detecting element. In both cases, the results show a very good change corresponding to the thickness change of the test specimen. During these experiments a carbon steel tube of diameter 210mm and a length of 620mm, which is covered with insulator of 95mm thickness was used. To simulate the wall thinning, the thickness of the tube is changed for a specified length such as 2.5mm, 5mm and 8 mm from the inner surface of the tube. A 0.4mm thick Aluminum plate was covered on the Test specimen to simulate the shielding of the insulated pipelines. For both hall sensor and coil detection methods Fast Fourier transform(FFT) was calculated using window approach and the results for the test specimen without Aluminum shielding were summarized which shows a clear identification of thickness change in the test specimen by comparing the magnitude spectra. The PEC system can detect the wall thinning under the 95 mm thickness insulation and 0.4 mm Al shielding, and the output signal showed linear relation with tube wall thickness.

입구온도 변화가 중공사형 나피온 막가습기의 성능에 미치는 영향에 대한 연구 (Study on Effect of Increase in Inlet Temperature on Nafion Membrane Humidifier)

  • 황준영;장효선;강경태;강희석
    • 대한기계학회논문집B
    • /
    • 제35권4호
    • /
    • pp.361-369
    • /
    • 2011
  • 실험과 수치해석을 이용하여 차량용 PEMFC 시스템의 공기 공급부 운전환경에 따른 막 가습기의 성능 특성에 대한 연구를 수행하였다. Nafion 막을 이용한 Shell-and-Tube 형 막가습기의 입구온도변화에 따른 열 및 물 전달 특성에 알아보기 위한 실험을 수행하였으며, 이로부터 가습기 막을 통한 물전달 성능이 입구 온도에 대하여 비선형적으로 변화하는 특성을 확인하였다. Nafion 막의 물전달 계수를 경계면의 온도와 상대습도의 함수로서 모델링하여 단일 튜브형 막에 대한 수치해석을 수행하였으며, 해석 결과를 실험 결과와 비교하였다. 막을 통한 국소물질량유속 분포가 튜브 내에서 급격하고도 비선형적으로 변화하는 해석 결과를 얻을 수 있었으며, 이로부터 입구 온도가 가습기 성능에 미치는 영향을 논의하였다.

공내수 치환기법을 이용한 연안지역 대수층의 수리특성 평가 (Detection of inflow permeable zones using fluid conductivity logging in coastal aquifer)

  • 황세호;박윤성;신제현;박권규;최선영;이상규
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2005년도 제7회 특별심포지움 논문집
    • /
    • pp.83-92
    • /
    • 2005
  • 연안지역에서 해수침투대의 특성을 파악하기 위하여 전기전도도 검층을 수행하였다. 검층의 목적은 투수성 파쇄대 및 고염분 지하수가 유입되는 구간의 확인이다. 전기전도도 검층은 시추공 내의 지하수를 전기적으로 다른 성질을 갖는 지하수로 치환하고 일정 양수 또는 자연 상태에서 시간에 따른 전기전도도의 변화를 측정한다. 따라서 시추공과 교차하는 투수성 파쇄대 또는 다공성의 대수층에서 시추공내로 유입되는 지층수 전기전도도의 변화 특성을 일정 시간 간격에 따라서 측정하면 지하수가 유입되는 구간의 확인이 가능하다. 현장 시험에 적용한 공내수 치환 시스템은 주입과 양수, 유량측정이 가능하며 내경이 작은 모니터링 PVC 케이싱도 적용이 가능하도록 제작하였다. 전남 영광의 연안지역에 위치하는 3개 시추공에 공내수 치환기법을 적용하여 전기전도도의 변화 특성을 측정한 결과, 연안지역의 고염분지하수는 균열암반을 통한 해수침투는 물론 간척사업으로 인한 잔류염분의 영향을 동시에 받고 있음을 확인할 수 있었다. 공내수 치환기법과 추가적으로 수행될 정량적인 해석 결과는 연안지역에서 수리상수 추정, 최적의 양수설계, 해수침투 특성 평가 등에 활용될 것으로 예상된다.

  • PDF