• Title/Summary/Keyword: Transmission Line Parameter

Search Result 115, Processing Time 0.031 seconds

On a Study of Measurement Method of Utterance Velocity for the Reduction of Transmission Rate in CELP Vocoder. (LSP 파라미터를 이용한 발성측정법)

  • 장경아;배명진
    • Proceedings of the IEEK Conference
    • /
    • 2000.11d
    • /
    • pp.199-202
    • /
    • 2000
  • Speaking Rate has variety depends on the situation and habit of speakers. It has been many studied about speaking rate In speaker recognition. The study of speaking rate in speech recognition is one of considerable matter when It is recognized the speakers and it is measured by many speech data base and complicate estimation for accuracy. In this paper, conventional vocoder process the speech signal when encoding and transmitting without regard to speaking rate so in order to apply the speaking rate for vocoder It should be considered the simpler algorithm and less computation amount than the conventional method of speaking rate used In speech recognition. We proposed the speaking rate algorithm which is used the simple parameter with Line Spectrum Pair (LSP). The proposed peaking rate method is measured by the information of LSP in speech. We measured the variety rate of phenomenon about utterances which have different velocity, respectively. As a result, It has distinct variation rate of phenomenon between utterances uttered fast and slow and the rate is 42.8% higher in case of uttered fast than in case of uttered slow.

  • PDF

Simulation of the Three-phase DC Reactor Type Fault Current Limiter for the Short-circuit Test (삼상형 dc reactor형태 한류기의 단락회로실험을 위한 시뮬레이션)

  • Lee, Eung-Ro;Lee, Seung-Je;Lee, Chan-Joo;Ko, Tae-Kuk;Hyun, Ok-Bae
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.717-719
    • /
    • 2001
  • This paper deals with simulation of the three-phase dc reactor type fault current limiter(FCL). This is a preliminary step to develop the FCL's faculties for an application to high voltage transmission line. A three-phase dc reactor type FCL consists of transformers, diodes, and a superconducting coil. By this simulation for the short-circuit test we can investigate the safety of FCL's elements. And, result of simulation will contribute parameter toward optimal design.

  • PDF

Series and Parallel Sin+Cos PSS (직렬 및 병렬 Sin+Cos 전력계통안정화장치)

  • Lee, Sang-Seung
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.87-89
    • /
    • 2005
  • This paper proposes new series and parallel Sin+Cos PSS(power system stabilizer) for the purpose to improve the existing PSS1A's performance. The purpose of PSS is used to enhance damping of power system oscillations through injection of auxiliary signal for an excitation control terminal. The Proposed series and Parallel Sin+Cos PSS is connected adding the Sin+Cos terms additionally with serial and with parallel connection in a conventional PSS1A. The proposed controller is aim to considering of a damping of oscillation when it changes parameter fluctuations or operational load variations in a power system. The object of electric power system is KEPCO system and the voltage of power transmission line is a 154kV and a 345kV. The PSCAD/EMTDC package is used to authorize the effect of the proposed controller. Simulations were shown by and compared with the waveforms for frequency, voltage and electric power.

  • PDF

Properties of As-casted High Nitrogen Steel for Core of Over-head Transmission Line (가공 송전선 강심용 고질소강 주조재의 제특성)

  • Yoo, Kyung-Jae;Kim, Bong-Seo;Kwon, Hae-Woong;Kim, Byung-Geol;Lee, Hee-Woong
    • Proceedings of the KIEE Conference
    • /
    • 1998.11c
    • /
    • pp.861-863
    • /
    • 1998
  • As-casted high nitrogen alloys (Fe-25%Mn-12%Cr-1%Ni) have been investigated to study core material. Nitrogen concentration in molten alloys was increased with increasing the square root of nitrogen gas pressure in melting chamber. This result can be explained by Sievert's law. Nitrogen that dissolved as a interstital solid solution element in austenite stainless steel increased lattice parameter and hardness. Electric resistivity($\rho$) was increased with increasing nitrogen concentration and was about $80{\mu}{\Omega}cm$ at room temperature. Coefficient of linear thermal expansion of the nitrogen steel was about $22{\times}10^{-6}/^{\circ}C$.

  • PDF

Screen printed contacts formation by rapid thermal annealing in multicrystalline silicon solar cells

  • Kim, Kyung hae;U. Gangopadhyay;Han, Chang-Soo;K. Chakrabarty;J. Yi
    • Journal of Korean Vacuum Science & Technology
    • /
    • v.6 no.3
    • /
    • pp.120-125
    • /
    • 2002
  • The aim of the present work is to optimized the annealing parameter in both front and back screen printed contacts realization on p-type multicrystalline silicon and with phosphorus diffused. The RTA treatments were carried out at various temperatures from 600 to 850$\^{C}$ and annealing time ranging from 3 min to 5 min in air, O$_2$and N$_2$ ambiance. The contacts parameters are obtained according to Transmission Line Model measurements. A good RTA cycle is obtained with a temperature plateau of 700$\^{C}$-750$\^{C}$ and annealing ambiance of air. Several processing parameters required for good cell efficiency are discussed with an emphasis placed on the critical role of the glass frit in the aluminum paste. A anamolus behaviour of Aluminum n-doping on p-type Si wafer, contact at high temperature have also been studied.

  • PDF

A Design of BJT-based ESD Protection Device combining SCR for High Voltage Power Clamps

  • Jung, Jin-Woo;Koo, Yong-Seo
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.14 no.3
    • /
    • pp.339-344
    • /
    • 2014
  • This paper presents a novel bipolar junction transistor (BJT) based electrostatic discharge (ESD) protection device. This protection device was designed for 20V power clamps and fabricated by a process with Bipolar-CMOS-DMOS (BCD) $0.18{\mu}m$. The current-voltage characteristics of this protection device was verified by the transmission line pulse (TLP) system and the DC BV characteristic was verified by using a semiconductor parameter analyzer. From the experimental results, the proposed device has a trigger voltage of 29.1V, holding voltage of 22.4V and low on-resistance of approximately $1.6{\Omega}$. In addition, the test of ESD robustness showed that the ESD successfully passed through human body model (HBM) 8kV. In this paper, the operational mechanism of this protection device was investigated by structural analysis of the proposed device. In addition, the proposed device were obtained as stack structures and verified.

Determination of Design Parameters of Stockbridge Damper (스톡브리지 댐퍼 설계 파라미터 선정)

  • Kim, Chan-Jung
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.26 no.7
    • /
    • pp.814-819
    • /
    • 2016
  • The Stockbridge damper is used to control the aeolian vibration of a overhead transmission line due to the natural wind under a low velocity, between 1 m/s to 7 m/s. The damper model can be simply derived with several design parameters and the location of eigenvalues of design parameters are important to determine the efficiency of energy dissipation by excitation itself with two counterweights. First, the importance of resonance frequencies of Stockbridge damper was reviewed through the analysis of frequency response function of damper system. Then, the best selection of design parameters was investigated with the introduction of objected function that minimize the distance between the calculated eigenvalues and target frequency points. The best choice of design parameters was reviewed using the simulated results from the objective function and the effectiveness of selected design case was discussed at the point view of practical implementation.

High Pass Filter Design Using Folded Coplanar Waveguide CRLH Transmission Line

  • Yang, Lei;Yang, Doo-Yeong
    • International Journal of Contents
    • /
    • v.11 no.3
    • /
    • pp.63-68
    • /
    • 2015
  • A novel unit cell for a high pass filter was designed based on a composite right/left-handed structure that uses a folded coplanar waveguide. The equivalent circuit model for the unit cell was extracted from the geometry of the unit cell, and the effect of each main parameter of the unit cell was analyzed. The equations to calculate the immittance values of the equivalent circuit elements were formulated, and moreover, the dispersion characteristics and energy the distributions of the electromagnetic fields were simulated to determine the characteristics of the composite right/left-handed structure. Finally, the high pass filters were implemented as a series of the proposed unit cells. We show that the experimental results were in good agreement with those obtained from the simulation. Thus, the high pass filter was found to achieve a baseband insertion loss of 3 dB and a stopband attenuation of 70 dB.

Design of An Open-Ended Coaxial Cavity Resonator (한쪽 면이 열린 동축 공동 공진기의 설계에 대한 연구)

  • Lee, Yun-Min;Kim, Jin-Kook;Hur, Jung
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.13 no.4
    • /
    • pp.201-208
    • /
    • 2013
  • This paper is a study of an empirical design of an open-ended coaxial cavity resonator. It can be done by using the radius of the inner conductor, the inner radius and the length of the resonator. However, the basic coaxial transmission -line theory can be seen that the characteristics of the resonant frequency and the Q value are varied by the change of length, regardless of the value of radius of the inner conductor and inner radius of the resonator. We find out the impact of radius of the inner conductor, inner radius of the resonator and the length of the resonator parameter and propose the optimized empirical resonator design method by reducing the error between the theoretical value and the design value. Based on the simulation, several resonators are fabricated by the size of 14 mm for the radius of inner conductor, 2 mm, 5 mm, 10 mm respectively for the inner radius of resonator, and 8.5 mm for the length of the resonator. The resonant frequencies of the produced resonators were measured at 6.1, 5.7, 6.5 GHz respectively. According to the result of simulation and measurement, we know that we can design the relatively exact open-ended coaxial cavity resonator by applying the basic coaxial transmission-line theory directly when the length of the resonator is less than 10 mm, and adding the correction factor of 0.5 GHz to the calculated resonant frequency in case of more than 10 mm of the length of the resonator.

The Effects of Sand Compaction by Watering through Field Compaction Test and Numerical Analysis (현장 및 수치해석을 통한 모래 물다짐지반의 다짐효과 연구)

  • Chun, Byungsik;Jang, Younsoo;Kim, Kwanggyu;Park, Dukhyum;Sung, Hwadon
    • Journal of the Korean GEO-environmental Society
    • /
    • v.8 no.6
    • /
    • pp.13-19
    • /
    • 2007
  • This study examines a cause for damage of synthetic resins straight pipe occurred after pipe construction of underground electric power duct pipelines of ${\bigcirc}$ section work, ${\bigcirc}$ line, ${\bigcirc}{\bigcirc}$ city railroad. For this, we analyzed a parameter used for plan and structural analysis through a literature review. And the site condition was analyzed in detail, and test construction of the pipe line that simulated the site pipe line and test on compaction by watering were performed. In addition, an examination on subsurface settlement influence of foundation ground through a structural safety and a numerical analysis of power transmission pipe line was performed. As a result of the performance, relative density gained by compaction by watering was more than average and relative degree of compaction according to technical specification standard showed the result of about 90% in the case of good compaction by watering.

  • PDF