• Title/Summary/Keyword: Transient Characteristics

Search Result 1,787, Processing Time 0.031 seconds

A Study of $NH_3$ Adsorption/Desorption Characteristics in the Monolithic $NH_3-SCR$ Reactor (모노리스 $NH_3-SCR$ 반응기 내에서의 $NH_3$ 흡.탈착 특성에 대한 연구)

  • Wang, Tae-Joong;Baek, Seung-Wook;Jung, Myung-Geun;Yeo, Gwon-Koo
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.14 no.3
    • /
    • pp.125-132
    • /
    • 2006
  • Transient kinetics of $NH_3$ adsorption/desorption and of SCR(selective catalytic reduction) of NO with $NH_3$ were studied over vanadium based catalysts, such as $V_2O_5/TiO_2$ and $V_2O_5-WO_3/TiO_2$. In the present catalytic reaction process, NO adsorption is neglected while $NH_3$ is strongly chemisorbed on the catalytic surface. Accordingly, it is ruled out the possibility of a reaction between strongly adsorbed $NH_3$ and NO species in line with the hypothesis of an Eley-Rideal mechanism. The present kinetic model assumes; (1) non-activated $NH_3$ adsorption, (2) Temkin-type $NH_3$ coverage dependence of the desorption energy, (3) non-linear dependence of the SCR reaction rate on the $NH_3$ surface coverage. Thus, the surface heterogeneity for adsorption/desorption of $NH_3$ is taken into account in this model. The present study extends the pure chemical kinetic model based on a powdered-phase catalytic system to the chemico-physical one applicable to a realistic monolith reactor.

Characteristics of Hypoxic Pulmonary Vasoconstriction of the Rat: Study by the Vessel Size and Location in the Lung

  • Lee, Sang-Jin;Kim, Ki-Whan
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.3 no.3
    • /
    • pp.321-328
    • /
    • 1999
  • Pulmonary blood vessels with diameters of $200{\sim}400\;{\mu}m$ produce considerably more force in response to vasoconstrictor drugs than those which are either smaller or larger. We have therefore investigated whether or not hypoxic pulmonary vasoconstriction (HPV) is more powerful in vessels of these diameters. We have also looked at the possibility that vessels from different regions of the lung respond differently. To do this we have grouped vessels according to their location within the lung as well as by size. We used a small vessel myograph (Cambustion AM10, Cambridge, UK) to study 208 preconstricted $(1\;{\mu}M\;PGF_{2{\alpha}})$ small pulmonary arteries $(300{\sim}800\;{\mu}m$ diameter when stretched to a tension equivalent to 25 mmHg transmural pressure) from 39 rats anaesthetized with 2% inspired halothane. A biphasic contraction was observed in response to hypoxia (ca. 25 mmHg $Po_2).$ The magnitudes of both the first, transient, phase (PT, peak tension) and of the second, sustained, phase (SST, steady state tension) were measured. The latter was measured 40 min after the start of hypoxia. The first phase was most pronounced in vessels with an average diameter of 423 ${\mu}m$ while the second phase was most pronounced in larger vessels (mean diameter 505 ${\mu}m).$ These maximal responses were all seen in vessels somewhat larger than reported by others. The responses of smaller vessels $(400{\sim}500\;{\mu}m)$ did not depend upon their location within the lung, but those of larger vessels $(600{\sim}700\;{\mu}m)$ showed regional differences. Those from the right lobe and those from the base of the lung gave the largest responses. It was especially noticeable that large vessels (631 ${\mu}m$ diameter) from the base of the right lung gave the biggest responses. Thus HPV seems to occur not in a uniform manner, dependent solely to the size of vessels, but it also depends to some degree on the region of the lung from which vessels have been taken. Furthermore, our results suggest that larger vessels, as well as smaller ones, may contribute significantly to HPV.

  • PDF

Brain Delivery of $^{99m}Tc$-Diethylene Triamine Pentaacetic Acid and Phenytoin by Transient Osmotic Opening Method in Rats (흰쥐에서 삼투개열법에 의한 $^{99m}Tc$-Diethylene Triamine Pentaacetic Acid 및 페니토인의 뇌로의 송달)

  • Hwang, Man-Yong;Park, Kyoung-Ho;Lee, Min-Hwa
    • YAKHAK HOEJI
    • /
    • v.42 no.2
    • /
    • pp.196-204
    • /
    • 1998
  • The blood-brain barrier (BBB) of rats was modificated opening reversibly by infusing a hyperosmotic solution of arabinose (1.6 molal) into the right external carotid artery. Pre vious studies demonstrated that permeability was increased maxmmally in the first 15 min and remained slightly elevated at 1 hr. As control reference, saline was used. In the present study, to evaluate the effects of osmotic BBB opening on the BBB trasport according to hydrophilic or hydrophobic characteristics of drugs. And the differences of the uptakes of these compounds to right (treated osmotic opening) and left (untreated) hemispheres in same rats were compared each other following injection of 8 mCi per rat of $^{99m}Tc$-ethylene triamine pentaacetic acid (DTPA) as hydrophilic drug or 5mg/kg of phenytoin as hydrophobic drug mto the right external carotid artery of rats between two groups (1.6 molal arabinose vs saline). The uptakes of $^{99m}Tc$-DTPA and phenytoin in the right cerebral hemispheres were increased to about thirty three times and twice rather than those in the left cerebral heimspheres, respectively. And PAs (permeability X capillary surface area) were also increased from a control mean of 2.11${\times}10^{-4}$ (Untreated) to 6.98${\times}10^{-3}\;sec^{-1}$ (treated osmotic opening for $^{99m}Tc$-DTPA and 0.29 to 0.17 $sec^{-1}$ for phenytoin, respectively. From the results of present study, it is noted that osmotic opening of BBB is more effective in the brain delivery of hydrophilic drugs rather than that of hydrophobic drugs.

  • PDF

Jeju 80kV HVDC Controller Modeling Using PSCAD/EMTDC Program (PSCAD/EMTDC 프로그램을 이용한 제주 80kV HVDC 제어기 모델링)

  • Choi, Soon-Ho;Lee, Seong-Doo;Kim, Chan-Ki
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.6
    • /
    • pp.533-541
    • /
    • 2011
  • This paper studies modeling of Jeju 80kV HVDC system and its controller by using PSCAD/EMTDC program. Reduced ac network is applied to verify interaction between ac network and dc system. Design parameter is applied to the converter transformer, harmonic filter and dc transmisstion line to simulate dc system. HVDC controller is divided into a rectifier controller and a inverter controller according to the converter operating mode. The inverter controller is composed of current control, voltage control and extingtion angle control. The rectifier controller is composed of current control and voltage control. Both controller has VDCOL characteristics so that current order is dependant on voltage variation. Step response, ac network single phase fault, three phase fault is simulated to verify the dynamic performance of controller model in both transient state and steady state.

A Numerical Study on Effects of Displacement of a Variable Area Nozzle on Flow and Thrust in a Jet Engine (가변노즐의 변위가 제트 엔진의 유동 및 추력특성에 미치는 영향에 관한 수치해석)

  • Park, Junho;Sohn, Chae Hoon;Park, Dong Chang
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.17 no.5
    • /
    • pp.1-9
    • /
    • 2013
  • Variable area nozzle, where both throat and exit area vary, is required for optimal expansion and optimal nozzle shape upon operation of after-burner. Steady-state and transient analyses are carried out for each condition with and without afterburner operation and as a function of the location of the nozzle flap. Effects of that nozzle displacement on flow and thrust characteristics are analyzed from numerical results. With variable area nozzle adopted, the combustion field is variable in time, leading to periodically variable thrust. For off-design conditions, flow separation shows up due to over expansion at the flap tips and shock wave does in the nozzle due to under expansion. The undesirable phenomena can be solved by control of variable area nozzle.

A Numerical Simulation of Unsteady Axisymmetric Turbulent Flow in a Reciprocating Engine Including Port/Valve Assembly (축대칭 왕복엔진의 비정상 난류유동에 대한 수치해석)

  • 조진행;유홍선;최영기
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.1
    • /
    • pp.139-149
    • /
    • 1994
  • A numerical simulation of unsteady axisymmetric turbulent flow was performed for a reciprocating engine including port/valve assembly. The governing equations based on a nonorthogonal coordinate formulation with Cartesian velocity components were used and discretised by the finite volume method with non-staggered variable arrangements. The modified $\kappa-\xi$. turbulence model which included the effect of compressibility was used. The results of twodimensional transient calculation for the axisymmetric configuration were compared with the experimental data. Although slightly low rms velocity was predicted compared to the experimental data, predicted velocity distributions at the valve exit and in-cylinder region showed good agreements with the experimental data. The flow at the valve exit was separated at the same valve lift position with the experimental data. Two vortices incylinder region were generated during the initial intake process. The clockwise main vortex became strong and moved upward to the top wall. The counter-clockwise second vortex became weak and stick to the upper left corner of the cylinder. After middle intake process, new vortex adjacent to upper cylinder wall appeared by the piston motion and therefore, the in-cylinder flow was formed into three vortices. The cylinder pressure just before bottom dead center of piston was higher than inlet pressure and then the reverse flow occured at the valve exit. The in-cylinder flow characteristics were strongly dependent on piston motion, but insensitive to valve motion.

Mathematical Modeling and Simulation for Steady State of a 75-ton Liquid Propellant Rocket Engine (75톤급 액체로켓엔진 정상상태 과정의 수학적 모델링 및 시뮬레이션)

  • Lee, Kyelim;Cha, Jihyoung;Ko, Sangho;Park, Soon-Young;Jung, Eunhwan
    • Journal of Aerospace System Engineering
    • /
    • v.11 no.5
    • /
    • pp.6-12
    • /
    • 2017
  • This paper deals with mathematical modeling of a 75-ton open-cycle Liquid Propellant Rocket Engine (LPRE) and the steady state simulation based on a nominal operating point. Each component of open-cycle LPRE may be classified into seven major categories using thermodynamics and dynamics characteristics. To simplify the simulation model of LPRE in this paper, we used four govern equations with assuming no heat transfer process. We confirmed the mathematical model of LPRE by using the error ratio and comparing the experiment data and simulation data in steady state, and checked the stability with the linearized model. Finally, we demonstrated the simulation model as compared to the transient response of experimental data.

The Analysis of the LCL Set-up Parameters for Satellite Power Distribution (위성전원분배를 위한 LCL 동작 파라미터 설정분석)

  • Lim, Seong-Bin;Jeon, Hyun-Jin;Kim, Kyung-Soo;Kim, Tae-Youn
    • Aerospace Engineering and Technology
    • /
    • v.10 no.2
    • /
    • pp.56-64
    • /
    • 2011
  • In this paper, the characteristics of LCL set-up parameters for the satellite load distribution are analyzed under the electrical system environment, implemented the LCL circuits and evaluated the performance and its behaviour. Recently, it is implemented the load distribution circuit by latching current limiter(LCL) rather than conventional fuse and relay for the protection of the satellite power system from a fault load. The LCL circuit is composed of the electrical components, not mechanical parts with the fuse and relay. When detected the over current on a fault load, it is activated to maintain the trip-off level for set-up time and then cut-off the load power by the active control. It is more flexible and provided a chance to reuse of the load in case of temporarily event, but the fuse and relay can't be used again after activating due to the physical disconnection. However, for implementation of LCL circuit, it should be carefully considered the behavior of the LCL circuit under the worst electrical system environment and applied it to define the set-up parameters related with over-current inhibition.

Precise Temperature Control of Oil Coolers with Hot-gas Bypass Manner for Machine Tools Based on PI and Feedforward Control (PI와 피드포워드 제어를 이용한 공작기계용 오일쿨러의 핫가스 바이패스 방식 정밀 온도 제어)

  • Jeong, Seok-Kwon;Byun, Jong-Yeong;Kim, Sang-Ho;Yoon, Jung-In
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.2
    • /
    • pp.111-119
    • /
    • 2011
  • Recently, the performances of speed and accuracy are enhanced in machine tools. The high speed of the machine tools usually causes harmful thermal displacements on the objects. To reduce the thermal displacements, machine tools generally adopt oil coolers with precise temperature control function. This study aims at precise control of oil outlet temperature in the oil coolers with hot-gas bypass manner based on PI control logic. The control system was designed for obtaining steady state error within ${\pm}0.1^{\circ}C$ and maximum overshoot with 0.8% even though abrupt disturbances are added to the system. We showed that the PI gains could be easily decided by numerical simulations using practical transfer function which got experiments. Also, transient characteristics could be improved significantly by reflecting the inlet temperature of an evaporator to the output of a controller feedforwardly considering periodic abrupt disturbances. Through some experiments, excellent control performances were established by the suggested control.

Fabrication of New Co-Silicided Si Field Emitter Array with Long Term Stability (Co-실리사이드를 이용한 새로운 고내구성 실리콘 전계방출소자의 제작)

  • Chang, Gee-Keun;Kim, Min-Young;Jeong, Jin-Cheol
    • Korean Journal of Materials Research
    • /
    • v.10 no.4
    • /
    • pp.301-304
    • /
    • 2000
  • A new triode type Co-silicided Si FEA(field emitter array) was realized by Co-silicidation of Co coated Si FEA and its field emission properties were investigated. The field emission properties of the fabricated device through the unit pixel with $45{\times}45$ tip array in the area of $250{\mu\textrm{m}}{\times}250{\mu\textrm{m}}$ under high vacuum condition of $10^{-8}Torr$ were as follows : the turn-on voltage was about 35V and the anode current was about $1.2\mu\textrm{A}(0.6㎁/tip)$ at the bias of $V_A=500V\;and\; V_G=55V$. The fabricated device showed the stable electrical characteristics without degradation of field emission current for the long term operation except for the initial transient state. The low turn-on voltage and the high current stability of the Co-silicided Si FEA were due to the thermal and chemical stability and the low work function of silicide layer formed at the surface of Si tip.

  • PDF