• Title/Summary/Keyword: Transfer efficiency

Search Result 2,708, Processing Time 0.035 seconds

Heat Transfer Analysis of Energy Pile Considering heat transfer medium (열전달 매질을 고려한 에너지파일의 열전달 거동 분석)

  • Kim, Do-Hyun;Jeong, Sang-Seom;Song, Jin-Young
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.963-970
    • /
    • 2010
  • In this study, a series of thermal numerical analysis was conducted through the ground condition and the length and shape of the energy pile. In order to investigate the effect of the thermal properties of ground condition, grout and pile type on heat transfer efficiency in the U-type heat exchanger in energy pile, thermal numerical analysis was done by using ABAQUS. ABAQUS, a finite element analyzing program, was employed to evaluate the temperature distribution on the cross section of energy pile system incorporating HDPE - grout - pile - Ground condition which consists of clay, sand, rock type soil and ground water.

  • PDF

Parallelized Unstructured-Grid Finite Volume Method for Modeling Radiative Heat Transfer

  • Kim Gunhong;Kim Seokgwon;Kim Yongmo
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.4
    • /
    • pp.1006-1017
    • /
    • 2005
  • In this work, we developed an accurate and efficient radiative finite volume method applicable for the complex 2D planar and 3D geometries using an unstructured-grid finite volume method. The present numerical model has fully been validated by several benchmark cases including the radiative heat transfer in quadrilateral enclosure with isothermal medium, tetrahedral enclosure, a three-dimensional idealized furnace, as well as convection-coupled radiative heat transfer in a square enclosure. The numerical results for all cases are well agreed with the previous results. Special emphasis is given to the parallelization of the unstructured-grid radiative FVM using the domain decomposition approach. Numerical results indicate that the present parallel unstruc­tured-grid FVM has the good performance in terms of accuracy, geometric flexibility, and computational efficiency.

Vibration Analysis of 3-Dimensional Structure by using Mixed Method of Finite Element-Transfer Matrix (유한요소-전달행렬의 혼합물을 이용한 3차원 구조물의 진동해석)

  • 이동명
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.10 no.1
    • /
    • pp.16-22
    • /
    • 2001
  • In this study for reduction degree of freedom of dynamic model, a mixed method to combined finite element method and transfer matrix method is presented. This offers the advantages of an automatic reduction in the size of the eigenvalues problem and of a straightforward means of dynamic substructuring. The analytical procedure in this method for dynamic analysis of 3-dimensional cantilevered box beam are described. the result of numerical example is shown to demonstate the efficiency and accuracy of this method. The result form this example agree well those obtained by ANSYS, By using this technique, the number of nodes required in the regular finite element method is reduced and therefore a smaller com-puter can be used.

  • PDF

A Study on Performance Characteristics of Heat Exchanger for Heat Pump with R410A Refrigerant (R410A 냉매를 사용한 열펌프용 열교환기의 형상에 따른 성능특성 연구)

  • 정규하;박윤철;오상경
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.4
    • /
    • pp.340-348
    • /
    • 2004
  • The air and refrigerant side heat transfer performances are key parameters to improve heat transfer efficiency of the heat exchanger including the fan performance. Design of the fins, treatment of the tube inside, tube diameter and tube array effect heat transfer performance of the heat exchanger. The heat exchanger is used as a condenser at cooling mode and used as an evaporator at heating mode in the heat pump system. The heat pump system uses R410A as the refrigerant. The heat exchangers are consisted with 7 mm diameter tubes with slit-type fins. The study was conducted with variation of arrangement of the refrigerant path and air flow rate and refrigerant pressure drop and heat transfer rate were measured with a code tester. The capacity of the 3 path heat exchanger is more efficient than 2 or 4 path heat exchangers in heating or cooling modes.

An Effective Experimental Optimization Method for Wireless Power Transfer System Design Using Frequency Domain Measurement

  • Jeong, Sangyeong;Kim, Mina;Jung, Jee-Hoon;Kim, Jingook
    • Journal of electromagnetic engineering and science
    • /
    • v.17 no.4
    • /
    • pp.208-220
    • /
    • 2017
  • This paper proposes an experimental optimization method for a wireless power transfer (WPT) system. The power transfer characteristics of a WPT system with arbitrary loads and various types of coupling and compensation networks can be extracted by frequency domain measurements. The various performance parameters of the WPT system, such as input real/imaginary/apparent power, power factor, efficiency, output power and voltage gain, can be accurately extracted in a frequency domain by a single passive measurement. Subsequently, the design parameters can be efficiently tuned by separating the overall design steps into two parts. The extracted performance parameters of the WPT system were validated with time-domain experiments.

Transient Response Analysis of Frame Structures Using the Finite Element-transfer Stiffness Coefficient Method (FE-TSCM) (유한요소-전달강성계수법을 이용한 골조 구조물의 과도응답해석)

  • 최명수;문덕홍;김성진
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.12 no.9
    • /
    • pp.674-684
    • /
    • 2002
  • In order to decrease remarkably the computation time and storage used in the direct integration method without the loss of accuracy, authors suggest a new transient analysis algorithm. This algorithm is derived from the combination of three techniques, that is, the transfer technique of the transfer stiffness coefficient method, the modeling technique of the finite element method, and the numerical integration technique of the Newmark method. In this paper, the transient analysis algorithm of a frame structure is formulated by the proposed method. The accuracy and computation efficiency of the proposed method are demonstrated through the comparing with the computation results by the direct integration method for three computation models under various excitations.

Forced Convection Heat Transfer in a Plate Fin With Transient Heat Conduction (과도열전도를 갖는 평판핀에서의 강제대류 열전달)

  • 조진호;이상균
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.9 no.4
    • /
    • pp.69-76
    • /
    • 1987
  • A conjugate conduction-convection analysis has been made for a plate fin which exchanges heat with its fluid environment by forced convection. The analysis is based on a one- dimensional model for the plate fin whereby the transient heat conduction equation for the fin is solved simultaneously with the conservation equations for mass, momentum, and energy in the fluid boundary layer adjacent to the fin. The forced convection heat transfer coefficient is not specified in advance but is one the results of the numerical solutions. Numerical results of the overall heat transfer rate, the local heat transfer coefficient, the local heat flux, the fin efficiency and the fin surface temperature distribution for Pr=0.7 are presented for a wide range of operating conditions.

  • PDF

Effect of Flux Type on Arc Characteristic of FCA Welding (FCA 용접의 아크현상에 미치는 Flux Type의 영향)

  • 강성원;오은식;유덕상;안영호
    • Journal of Welding and Joining
    • /
    • v.17 no.1
    • /
    • pp.116-123
    • /
    • 1999
  • The $CO_2$ welding with 100% $CO_2$ shielding gas is commonly used because of its cost and efficiency. Arc phenomena of the $CO_2$ welding is influenced by various factors such as chemical compositions of welding wire, shielding gas, welding condition and welding power source etc. In this study, arc phenomena is investigated by using two type of FCW(titania type, semi-metal type). Then, the welding quality and optimum welding condition can be selected. From this study, the following results were obtained; 1) In low current range(140A), FCW up to welding voltage(22V) resulted in a typical short circuit transfer. 2) In high current range(320A), the arc stability in titania FCW of a typical globular transfer is better than that of semi-metal FCW.

  • PDF

An experimental study on the heat transfer of the turbocharged gasoline engine (터보과급 가솔린의 열전달에 관한 실험적 연구)

  • 최영돈;홍진관
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.3
    • /
    • pp.664-675
    • /
    • 1990
  • In this study, the performance test and heat transfer experiment for a 4 cylinder and 4-cycle turbocharged gasoline engine were carried out in order to measure the heat transfer coefficient at the inner wall of the combustion chamber. From the result of heat transfer experiment, the energy balance of the fuel energy and the overall efficiency of the turbocharger were calculated, The variation of them was investigated as well with the engine operation conditions.

A Dynamic Characteristic of the Multi-Inverter Heat Pump with Frosting (착상을 수반한 멀티 가변속 열펌프의 동특성)

  • ;;Shigeru Koyama
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.5
    • /
    • pp.337-345
    • /
    • 2003
  • In the case of heat exchangers operating under frosting condition, the growth of frost layer causes the heat exchanger to increase the thermal resistance and pressure loss of the air flow. In this paper, a transient characteristic prediction model of the heat transfer for multi inverter heat pump with frosting on its surface was presented taking into account the change of the fin efficiency due to the growth of the frost layer. In this dynamic simulation program, which was peformed for a basic air conditioning system model, such as evaporator, condenser, compressor, linear electronic expansion valve (LEV) and bypass circuit. The theoretical model was driven from the obtained heat transfer coefficient and mass transfer coefficient, independently. And we consider heat transfer performance was only affected by a decrease of the wind flow area. The calculated results were compared with some cases of experiments for frosting conditions.