• Title/Summary/Keyword: Total Energy Consumption

Search Result 992, Processing Time 0.026 seconds

Thermal Performance of Solar Cooling & Hot-water System According to Control Condition (태양열 냉방 및 급탕 시스템의 제어 조건에 따른 열성능)

  • Lee, Ho;Joo, Hong-Jin;Kim, Sang-Jin;Kwak, Hee-Yeol
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.11a
    • /
    • pp.214-219
    • /
    • 2008
  • This study is describes thermal performance of solar cooling and hot water for demonstration system with ETSC(Evacuated tubular solar collector) installed at Seo-gu culture center of Kwanju. Control condition for solar cooling and hot water system is changed by connection of auxiliary heater. Demonstration system was connected to central air conditioning system. Demonstration system was operated by two types. First type(A) was operated to cooling and hot water supply in that order. Second type(B) was operated to hot water supply and cooling in that order. As a result. it was indicated that the total solar energy consumption of (A) was 799 MJ and the solar energy consumption rate for the cooling and hot water supply was 70% and 30% respectively. Total solar energy consumption of (b) was 898 MJ and the solar energy consumption rate for the cooling and hot water supply was 31% and 69% respectively.

  • PDF

Comparison of Heat Pump Performance and Energy Consumption Patterns according to Heat Sources for Optimal Control of Multi-Source Heat Pumps (복합열원 히트펌프 최적 제어를 위한 열원에 따른 히트펌프 성능 및 에너지 소요량 패턴 비교)

  • Ko, Yujin;Park, Sihun;Min, Joonki
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.16 no.4
    • /
    • pp.31-38
    • /
    • 2020
  • The investment in the technology of using a combined heat source is insufficient, which utilizes the advantages of various heat sources to maximize the potential energy and at the same time increases the performance of the heat pump. In this study, as basic data for the development of a high-efficiency hybrid heat pump system that actively connects and uses various heat sources, simulations were conducted for the heat pumps in two cases where geothermal and hydrothermal heat were applied respectively. In May, COP increased by about 27.3% compared to geothermal heat. In February, the COP percentage decrease of hydrothermal heat compared to geothermal heat is -6.9%. In May, total energy consumption can be reduced by 21.1% when hydrothermal is applied compared to geothermal heat. In February, the total energy consumption increases by 3.4%.

A Case Study on Energy Performance Analysis of Retrofitted Building Using Inverse Model Toolkit (Inverse Model Toolkit을 이용한 리모델링 건축물의 에너지 성능평가 사례)

  • Kwon, Kyung-Woo;Lee, Suk-Joo;Park, Jun-Seok
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.8
    • /
    • pp.394-400
    • /
    • 2014
  • Several models and methods have been developed to verify the improvement of energy performance in retrofit buildings. The verification is important to confirm the effectiveness of new technologies or retrofits. Inverse model toolkit proposed by ASHRAE evaluates the changes of the energy performance of retrofit buildings by using actual energy consumption data. In this study, the inverse model toolkit was used to analyze heating and cooling energy performance of an office building. Analyzed coefficients of correlation of actual energy consumption with estimated energy consumption was above 0.92 and well fitted. It was confirmed that energy consumption of natural gas decreased by 43.4% and also that electricity decreased by 13.8%, after the retrofit of the case building. For the energy usage, cooling energy was increased by 7.4%, heating energy was decreased by 42.3%, hot water and cooking were increased by 3.4%, lighting and electronics were decreased by 19.3%, and the total energy was decreased by 18.9%.

Study on the Field Application of Insulation Performance Improvement Concrete (단열성능 향상 콘크리트의 현장 적용성 평가에 관한 연구)

  • Kang, Sung-Hyuk;Kim, Jung-Ho;Choo, Kyoung-Nam;Park, Young-Shin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.11a
    • /
    • pp.17-18
    • /
    • 2014
  • Recently, climate change have increased consumption of building heating and cooling energy. Therefore, various actions to reduce greenhouse gas and energy consumption have been prepared by world developed countries. The energy consumption by buildings approximately reaches 25% of total korea energy consumption. The greatest part in the buildings of the energy consumption is building facade. Especially the outer covering of the building has been made of concrete more than 70%. But a few research projects on concrete comprising more than 70% of outsider of buildings has been tried. This research is structural insulation concrete what improved insulation performance using Micro Form Admixture and Calcined Diatomite Powder and Lightweight Aggregate.

  • PDF

Empirical Research on Application of ICT for Reduction of Energy Consumption of Hospital Buildings (ICT를 활용한 병원건물의 에너지 절감방안 연구)

  • Lee, Junghwan;Han, Youngdo;Kim, Dongwook
    • The Journal of the Korea Contents Association
    • /
    • v.18 no.1
    • /
    • pp.422-430
    • /
    • 2018
  • Increase in oil prices and building energy consumption has been a great burden for Korea which has significant energy dependence on foreign energy sources. In this context, reduction of building energy consumption, which comprises 40% of total energy consumption, is a very important issue. This research therefore empirically analyzed a hospital "P" that implemented ICT-based energy consumption and cost reduction initiative. The hospital first replaced existing water absorber for heating/cooling air and boiler for heating water with water heat storage heat pump system. This was accompanied by subscribing to different electricity price plans to maximize cost reduction. Secondly, the hospital additionally applied ICT-based optimized control algorithm that considers surrounding factors (external temperature, changes in energy demand). The analysis of these mechanisms indicate that the ICT-based energy consumption and cost reduction initiative for hospitals can reduce energy consumption by 53.6% with replacement of low-efficiency equipment and additionally by 18.2% with optimized control algorithm. The mechanisms will provide energy consumption reduction opportunities for other hospitals and buildings with high energy consumption.

A Case Study for Energy Consumption Characteristics of High School Facilities in Seoul (서울지역 고등학교 건물의 에너지소비특성에 관한 사례분석)

  • Kim, Sung-Bum;Oh, Byung-Chil;Shin, U-Cheul
    • Journal of the Korean Solar Energy Society
    • /
    • v.36 no.6
    • /
    • pp.61-69
    • /
    • 2016
  • In this study, we analyzed five-year(2011~2015) data for D high school in Seoul area to analyze energy consumption characteristics in high school. The results are summarized as follows. (1) In the result of comparison analysis about 2015 energy consumption by usage, based on primary energy, 18% of energy was consumed in cafeteria, and 82% was consumed in main building. In the case of main building, base and constant load excepting hot water supply in restroom took 40%, heating including freeze protection took 20%, hot water supply in restroom took 14%, and cooling took 8% in order. (2) In the 2015 total energy consumption in D high school based on primary energy, heating energy takes 28%. The range and limit of energy savings coming from the reinforcement of insulation and window performance could be estimated. (3) To introduce new & renewable energy system in high school, electricity-based system is suitable than heat-based system because usage of electric energy is larger than that of heat energy in high school. (4) Five-year energy consumption unit according to heating degree-day showed a linearly increasing trend, and the coefficient of determination(R2) was 0.9763, which means high correlation.

Construction Equipment Fleet Optimization for Saving Fuel Consumption (에너지 절감을 위한 건설장비 조합 최적화 방법 연구)

  • Yi, Chang-Yong;Lee, Hong-Chul;Lee, Dong-Eun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.05a
    • /
    • pp.198-199
    • /
    • 2015
  • Construction equipment is a major energy consumption source in construction projects. If 10% reduction of the diesel fuel usage is achieved in the construction industry, it may reduce 5% of the total energy usage. Energy saving operation is a major issue in equipment-intensive operations (e.g., earthmoving or paving operations). Identifying optimal equipment fleet is important measure to achieve low-energy consumption in those operations. This study presents a system which finds an optimal equipment fleet by computing the low-energy performance of earthmoving operations. It establishes construction operation model and compares numerous combinations using alternative equipment allocation plans. It implements sensitivity analysis that facilitates searching the lowest energy consumption equipment fleet by enumerating all cases.

  • PDF

Modeling and Simulation of Smart Home Energy Consumption

  • Naziha Labiadh;Imen Amdouni;Lilia El Amraoui
    • International Journal of Computer Science & Network Security
    • /
    • v.24 no.6
    • /
    • pp.77-82
    • /
    • 2024
  • The Smart home energy consumption represents much of the total energy consumed in advanced countries. For this reason, the main objectif of this paper is to study the energy consumption profile by day for each home appliances: controllable appliances for example Washing machine, Tumble dryer and Air conditioning and uncontrollable appliances for example TV, PC, Lighting, Refrigerator and Electric heater. In this paper, we start with presentation of a smart home energy management systems. Next, we present the modeling and simulation of controllable appliances and uncontrollable appliances. Finally, concludes this paper with some prospects. The modeling and the simulation of a Smart home appliances is based on MATLAB/Simulink software.

Pattern Analysis of High-caffeine Energy Drink Consumption and Adverse Effects among College Students in a University (대학생들의 고카페인 에너지음료 소비실태 및 부작용 분석)

  • Lee, Jieun;Huh, Wan;Choi, Eun Joo
    • YAKHAK HOEJI
    • /
    • v.57 no.2
    • /
    • pp.110-118
    • /
    • 2013
  • High-caffeine energy drink consumption has been increasing in young adults, frequently causing the most common symptoms such as tremor, insomnia, anxiety, and nervousness and rarely leading to serious adverse effects like seizure, acute mania, and stroke due to caffeine overdose. There have been little current studies regarding analysis of high-caffeine energy drink consumption and its adverse effects in Korea. This study was to examine high-caffeine consumption patterns, associated factors, and adverse effects based on responses from 231 college students in a University through survey. About 88.3% (n=204) of total respondents reported that they had energy drinks. College students mostly consumed energy drinks to keep awake (46%) when studying and to recover fatigue (27%). Approximately 44% respondents mainly reported palpitation (73.9%) and insomnia (72.8%) regarding adverse effect questionnaire. Current reports on the risk of recreational use, co-ingestion of alcohol and energy drink as well as energy drink consumption among children and adolescents are increasing, requiring further long-term research and awareness of these issues.

Energy-Efficient Base Station Operation in Heterogeneous Cellular Networks

  • Nguyen, Hoang-Hiep;Hwang, Won-Joo
    • Journal of Korea Multimedia Society
    • /
    • v.15 no.12
    • /
    • pp.1456-1463
    • /
    • 2012
  • In this paper, we study the ON/OFF control policy of base stations in two-tier heterogeneous cellular networks to minimize the total power consumption of the system. Using heterogeneous cellular networks is a potential approach of providing higher throughput and coverage compared to conventional networks with only macrocell deployment, but in fact heterogeneous cellular networks often operates regardless of total power consumption, which is a very important issue of modern cellular networks. We propose a policy that controls the activation/deactivation of base stations in heterogeneous cellular networks to minimize total power consumption. Under this policy, the total power consumed can be significantly reduced when the traffic is low while the QoS requirement is satisfied.